Analog Devices

AD582KH - 1.5MHz Sample-and-Hold Amplifier | Analog Devices

MPN: AD582KH ✓ Active
2 mV Vdss TO-100-10 Package
MOQ: 1 |

AD582KH Overview

Analog Devices AD582KH is a single-channel sample-and-hold amplifier with a listed bandwidth of 1.5 MHz, 6 us acquisition time, 2 mV input offset voltage, and 500 ns settling time. The device is packaged in a 10-pin TO-100 package and is intended for precision analog signal acquisition, instrumentation, and control systems.

A sample-and-hold amplifier is an analog integrated circuit that samples an input voltage during a controlled acquisition interval and then stores that voltage on an external holding capacitor. It belongs to the broader sample-and-hold amplifier category, which combines an operational amplifier, a low-leakage analog switch, and a JFET integrating amplifier. The AD582 also provides separate analog and digital ground connections to improve immunity to ground and switching transients.

Key characteristics include one sampling channel, 1.5 MHz bandwidth, 6 us acquisition time, 2 mV input offset voltage, and 500 ns settling time. The external holding capacitor allows the sampled level to remain available after the acquisition interval ends. Separate analog and digital grounds are particularly useful in mixed-signal systems where the input signal path and digital control circuitry can otherwise share switching disturbances.

The AD582 is fabricated as a monolithic sample-and-hold circuit containing a high-performance operational amplifier, a low-leakage analog switch, and a JFET integrating amplifier. Its architecture supports rapid acquisition followed by stable signal holding, while the 10-pin TO-100 package facilitates through-hole assembly and repair. Analog Devices also identifies MIL-STD-883-compliant versions within the AD582 product family, although the exact qualification status of the KH suffix should be confirmed for a regulated program.

Typical applications include precision data-acquisition front ends, laboratory instrumentation, industrial process control, analog measurement systems, pulse sampling, and communications equipment. The AD582KH is particularly appropriate when a sampled analog value must be captured and held for conversion, comparison, control, or further signal processing during a later system cycle.

Circuit design must provide a suitable external holding capacitor, maintain low-leakage routing around the held node, and connect the analog and digital grounds according to the Analog Devices AD582 datasheet. Input and control timing also determine whether the 6 us acquisition specification is sufficient for the signal being sampled. Stable reference and supply arrangements are necessary for repeatable system-level accuracy.

This page combines the manufacturer architecture description, listed electrical characteristics, package information, drop-in family comparisons, and practical application guidance. It is intended to help engineers determine whether the AD582KH fits a sample-and-hold requirement while also identifying the key parameters that should be verified against the manufacturer datasheet before layout or production release.

Drop-in alternatives for AD582KH — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Variants in this series

Same-series models that are drop-in compatible with AD582KH (same form factor and footprint) — differing in Package, Acquisition Time, Holding Capacitor, Product Type, Mounting Type.

Analog Devices
Package: 14-CDIP, 0.300 inch (7.62 mm) body width
Holding Capacitor: External holding capacitor required
Product Type: 1 circuit sample-and-hold amplifier
Compare with AD582KH →
Analog Devices
Package: 14-CDIP, 0.300 in (7.62 mm) body width
Acquisition Time: 25 µs
Holding Capacitor: External holding capacitor
Compare with AD582KH →
Analog Devices
Package: TO-100 (10-pin metal can)
Acquisition Time: 6 µs (max)

AD582KH/+

✅ Drop-In
📦 TO-100-10
Same 10-pin TO-100 package, 1.5 MHz bandwidth, and 25 us family acquisition-time designation; 0% difference in the listed package, channel count, and bandwidth

📋 Reference alternative (not in catalog)

AD582SH/883B

✅ Drop-In
Analog Devices
📦 TO-100-10
Sample and Hold Amplifier · 1 · 6 µs (max) · ±15 V · 4.5 mA · -55°C to +125°C · TO-100 (10-pin metal can) · Wire

Contact for price

View Datasheet →

AD582KD

✅ Drop-In
Analog Devices
📦 TO-100-10
1 circuit sample-and-hold amplifier · 1 circuit · 14-CDIP, 0.300 inch (7.62 mm) body width · 3 V/us · Operational amplifier, low-leakage analog switch, and JFET integrating amplifier on one monolithic chip · Separate analog and digital grounds · External holding capacitor required · Versions available compliant with MIL-STD-883

Contact for price

View Datasheet →

AD582KH Maximum Ratings & Electrical Characteristics

Product Type Sample-and-hold amplifier
Number of Channels 1 channel
Number of Amplifiers 1 amplifier
Bandwidth 1.5 MHz
Acquisition Time 6 us
Product Category Acquisition Time 25 us
Input Offset Voltage 2 mV
Settling Time 500 ns
Internal Elements Operational amplifier, low-leakage analog switch, and JFET integrating amplifier
Holding Capacitor External
Ground Configuration Separate analog and digital grounds
Transient Immunity Immunity to ground and switching transients
Package TO-100-10
Pin Count 10 pins
Mounting Type Through-hole
Military Version Availability MIL-STD-883-compliant versions available within the AD582 family

AD582KH to-100-10 Pin Configuration Guide

Pin configuration for AD582KH (to-100-10 package). This analog component features input, output, and power supply pins. Refer to the manufacturer datasheet for offset null, compensation, and enable pin configurations. Ideal for signal conditioning and amplifier circuits.

to-100-10 package pinout diagram for AD582KH

No detailed pinout data available for AD582KH.

Refer to the datasheet for full pin configuration.

Typical Applications

AD582KH is suitable for 6 applications: Precision Data-Acquisition Front End, Laboratory Instrumentation, Industrial Process Control, Analog Measurement and Control Loops, Pulse and Transient Sampling, Communications Signal Conditioning.

📡

Precision Data-Acquisition Front End

The AD582KH fits a precision data-acquisition front end that must capture a changing analog input and present a stable held value to a converter or control system. Its listed 6 us acquisition time supports comparatively fast sampling intervals, while 1.5 MHz bandwidth accommodates higher-frequency input components. The 2 mV input offset and 500 ns settling characteristics should be included in the system error budget. Route the held node carefully, select the external holding capacitor according to the Analog Devices guidance, and keep leakage-producing traces away from the sample node.

🔧

Laboratory Instrumentation

The AD582KH can form the sampling stage of laboratory instrumentation that measures a rapidly varying signal and then holds it for display, calibration, or digitization. Its 1.5 MHz bandwidth provides useful signal-path bandwidth, and the 500 ns settling specification helps define how quickly the output can be considered settled after acquisition. The separate analog and digital ground terminals are valuable in instruments containing switching displays or digital control circuitry. Keep sensitive grounding paths isolated from those return currents and verify capacitor leakage against the required measurement accuracy.

🏭

Industrial Process Control

The AD582KH is applicable to industrial process-control loops where a pressure, temperature, or other analog sensor signal must be sampled at a controlled instant and held during controller processing. The 6 us acquisition time allows the sampling system to respond within a relatively short acquisition interval, while the 1.5 MHz bandwidth can pass faster sensor transients. Separate analog and digital grounds improve transient immunity in systems with relays, motor drives, or switching power stages. Provide filtering appropriate to the sensor bandwidth and maintain strict leakage control around the external holding capacitor.

🎛️

Analog Measurement and Control Loops

The AD582KH can capture an analog measurement and hold it for comparison, threshold evaluation, or closed-loop control. Its 2 mV listed input offset must be included in the achievable measurement accuracy, while the 500 ns settling time helps establish the interval available to the following measurement or control stage. The 10-pin TO-100-10 package supports through-hole construction and repairable laboratory or industrial equipment. Design the analog input path to avoid overload, verify common-mode and supply limits from the manufacturer datasheet, and use separate analog and digital ground routing.

⚡

Pulse and Transient Sampling

The AD582KH is suitable for capturing short-lived analog events that would be difficult to observe reliably with a continuously displaying measurement system. The 1.5 MHz bandwidth supports signal content around that range, and the 6 us acquisition figure provides the timing basis for capturing the event before the hold interval begins. Holding the selected level on an external capacitor allows downstream circuitry to process the event after the source has changed. Check input amplitude, sampling aperture, switch leakage, and capacitor dielectric behavior because these parameters determine whether the captured value retains the required amplitude.

🌐

Communications Signal Conditioning

The AD582KH can serve as a sampling element in communications equipment that needs to capture an analog level for later demodulation, thresholding, or feedback. Its 1.5 MHz bandwidth is suitable for many baseband signal-conditioning tasks, while separate analog and digital grounds help reduce susceptibility to switching transients in mixed-signal equipment. The sample-and-hold output must remain stable during downstream processing, making holding-capacitor selection and board contamination control especially important. Validate acquisition timing against the modulation waveform and confirm that the signal bandwidth does not exceed the device's operating limits.

Recommended Products Summary

What is the AD582KH?
The AD582KH is a single-channel sample-and-hold amplifier from Analog Devices with 1.5 MHz bandwidth, 6 us acquisition time, and a 10-pin TO-100 package. According to the Analog Devices AD582 product page, it combines a high-performance operational amplifier, a low-leakage analog switch, and a JFET integrating amplifier on one monolithic chip. It captures an input voltage during the acquisition interval and holds it on an external capacitor for subsequent measurement or processing.
What are the key specifications of AD582KH that engineers should know?
The AD582KH provides one channel, 1.5 MHz bandwidth, 6 us acquisition time, 2 mV input offset voltage, and 500 ns settling time in a TO-100-10 package. According to the listed AD582KH specifications, its architecture also includes a low-leakage analog switch and JFET integrating amplifier. These characteristics make the device relevant to precision data acquisition, analog measurement, industrial control, and instrumentation systems.
What is the AD582KH acquisition time?
The listed AD582KH acquisition time is 6 us. A separate product categorization also identifies the AD582 family with a 25 us acquisition-time figure, so engineers should confirm the exact timing condition and package suffix in the Analog Devices datasheet for their operating mode. The direct answer for the catalogued AD582KH entry is 6 us, while system timing should allow margin for capacitor selection and control-signal delay.
Where can I download the AD582KH datasheet PDF?
The official Analog Devices AD582 product page is the primary document location for AD582KH technical information and links to manufacturer documentation. It describes the monolithic sample-and-hold architecture, external holding capacitor, separate analog and digital grounds, and available MIL-STD-883-compliant family versions. Use the Analog Devices page rather than a distributor summary when validating pin functions, timing conditions, recommended capacitors, and electrical limits for production design.
Where can I find the AD582KH pinout?
The AD582KH uses a 10-pin TO-100 package, and its complete pin assignment should be taken from the Analog Devices AD582 datasheet. The product information confirms the package and pin count but does not reproduce the numbered pin table on this page. Use the manufacturer pin-description table and package drawing to assign power, ground, analog input, hold capacitor, and logic-control connections before laying out a replacement PCB.
What is the difference between AD582KH and AD582KH/+?
The AD582KH and AD582KH/+ are presented as having consistent terminals, packages, and principal performance characteristics, making AD582KH/+ a drop-in option in the same TO-100-10 format. The listed comparison identifies 1.5 MHz bandwidth, one channel, and 10 pins for the matched family entry. Confirm the manufacturer ordering code and full operating specifications before substitution because an identical footprint does not by itself establish every grade or qualification requirement.
Can AD582SH replace AD582KH?
The AD582SH can be considered a drop-in candidate for the AD582KH because the cross-reference description identifies consistent terminals, a 10-pin TO-100 package, and the same 25 us family acquisition-time designation. Before replacing the device, verify the detailed acquisition, bandwidth, offset, supply, and qualification requirements against the specific AD582SH datasheet. The shared footprint permits PCB reuse, but functional equivalence must still be confirmed for the target signal range and timing.
When should I choose AD582KH over AD582SH?
Choose the AD582KH when your system requires the catalogued 6 us acquisition-time entry, 1.5 MHz bandwidth, 2 mV input offset voltage, and 500 ns settling performance while retaining a TO-100-10 through-hole footprint. The AD582SH is a relevant same-package family alternative for designs whose complete timing and operating requirements are confirmed against its datasheet. The decision should be based on circuit timing, signal bandwidth, supply conditions, qualification, and procurement requirements rather than package appearance alone.
What can replace AD582KH on the same PCB?
The identified same-footprint choices are AD582KH/+, AD582SH, and AD582KD, all associated with the AD582 family and a 10-pin TO-100 format. AD582KH/+ is the closest listed match, with consistent terminals, package, and principal characteristics. The family alternatives can be evaluated for pin-compatible replacement, but each candidate must be checked for acquisition time, bandwidth, supply voltage, timing, and qualification requirements before production use.
Is AD582KH suitable for precision data acquisition?
The AD582KH is suitable for precision sample-and-hold stages that benefit from 1.5 MHz bandwidth, 6 us acquisition time, and separate analog and digital grounds. Its separate grounding architecture improves immunity to ground and switching transients, while the low-leakage analog switch and JFET integrating amplifier support accurate charge retention. Actual accuracy also depends on the external holding capacitor, leakage paths, input source impedance, grounding, and reference quality.
Where can I buy AD582KH and check its current lead time?
Use the Request a Quote form on this page to request AD582KH availability, current lead time, and order quantities from XAIPART. The listing identifies the exact AD582KH order code in a 10-pin TO-100-10 package, allowing the quote request to be matched without accepting a different suffix or package variant. Current stock status should be confirmed through the form because availability and production timing can change.
What is the price of AD582KH?
Use the Request a Quote form on this page for the current AD582KH price and quantity schedule. The structured pricing system separates quote requests from technical specifications and avoids presenting a potentially stale standalone amount. For comparison purposes, the part is specifically identified as the AD582KH suffix in a TO-100-10 package; do not substitute AD582KH/+, AD582SH, AD582KD, or another package code without reviewing the ordering requirements.
Is AD582KH in stock?
Current AD582KH inventory should be requested through the Request a Quote form on this page. The product is listed by Analog Devices and its exact order code is visible in distributor catalog records, but live stock, allocated inventory, and production lead time require a current quotation. Specify the required quantity, date code, packaging expectations, and target delivery schedule in the request.
Is AD582KH available for MIL-STD-883 applications?
Analog Devices states that MIL-STD-883-compliant versions are available within the AD582 family, but the KH suffix itself is not identified as a compliant ordering code in the product-page excerpt. Treat MIL-STD-883 qualification as unconfirmed for AD582KH unless the manufacturer documentation or part marking explicitly states it. Request the relevant qualification document and inspect the device markings before using the part in a screened or controlled program.
How does the AD582KH improve ground and transient immunity?
The AD582KH provides separate analog and digital ground connections, allowing sensitive analog paths to be referenced independently from control and switching-return currents. According to the Analog Devices AD582 product description, this arrangement improves immunity to ground and switching transients. In layout, route the two grounds deliberately to their specified points and avoid allowing high-current return paths to share the sensitive analog-ground region.

Engineering reference data for AD582KH — comparison, design guidance, and compliance information.

Selection Guide

Choose the AD582KH when the design requires a one-channel sample-and-hold amplifier with a listed 6 us acquisition time, 1.5 MHz bandwidth, 2 mV input offset, and a repairable 10-pin TO-100-10 through-hole package. AD582KH/+ is the closest listed same-footprint choice because the comparison identifies matching bandwidth, channel count, package, terminals, and principal characteristics. Consider AD582SH when its 25 us acquisition timing satisfies the control cycle and the full device requirements have been verified. AD582KD is another family candidate with the same TO-100-10 format, but it should be selected only after checking its electrical and qualification details. Because the identified alternatives are all Analog Devices family variants and no cross-brand drop-in part was confirmed, PCB reuse should be based on a complete manufacturer comparison rather than footprint similarity alone.

Comparison with Alternatives

Parameter This Product AD582KH/+ AD582SH AD582KD
Brand Analog Devices Analog Devices Analog Devices Analog Devices
Package TO-100-10 TO-100-10 - same TO-100-10 - same TO-100-10 - same
Number of Pins 10 pins 10 pins 10 pins 10 pins
Number of Channels 1 channel 1 channel 1 channel 1 channel
Acquisition Time 6 us 25 us family designation 25 us 25 us
Primary Architecture Operational amplifier, low-leakage analog switch, and JFET integrating amplifier AD582 family sample-and-hold architecture AD582 family sample-and-hold architecture AD582 family sample-and-hold architecture

Key Differentiators

  • Catalogued fast acquisition specification (vs AD582SH)
  • Closeest listed same-footprint family match (vs AD582SH)
  • Separate analog and digital grounding (vs AD582KD)

Design Notes

Assign the AD582KH pins strictly from the Analog Devices package drawing and pin-description table. The TO-100-10 package is not represented by a dedicated package-diagram asset on this page, so do not infer connections from physical pin order or another AD582 suffix. Before fabrication, verify every power, ground, analog-input, holding-capacitor, and logic-control connection against the manufacturer documentation and check the PCB pad pattern against the actual TO-100 outline.

Keep the external holding-capacitor connection extremely short and protect it from contamination, flux residue, and nearby high-impedance leakage paths. The low-leakage analog switch is intended to retain charge, but PCB leakage and capacitor dielectric characteristics can still determine practical accuracy. Route the held node away from switching nodes and digital return paths, and consider guarding where long traces or humid operating conditions increase leakage.

Use the separate analog and digital ground connections to prevent control or switching return currents from flowing through the sensitive analog-ground region. Connect each ground to the intended system reference point according to the Analog Devices application guidance. Place input and holding-capacitor components close to the device, minimize loop area, and keep switching-regulator and high-current traces spatially separated from the sample-and-hold signal path.

Do not treat the 6 us acquisition specification and the 25 us family designation as interchangeable without checking the exact datasheet timing conditions. Also validate input range, supply requirements, common-mode limits, and the external holding-capacitor recommendation before applying the circuit. These checks are especially important when substituting AD582KH/+, AD582SH, or AD582KD because a shared TO-100 footprint does not guarantee identical timing under every test condition.

Compliance Information

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Lead Free
Unknown
Halogen Free
Unknown
Conflict Minerals
Unknown

Analog Devices states that MIL-STD-883-compliant versions are available within the AD582 family. The exact AD582KH suffix is not identified as a compliant ordering code, so its individual qualification and environmental declarations require confirmation.

Data verified on: 2026-11-14 — data verified and curated by XAIPART's component engineering team

Related Searches

ad582 nsdl AD582KH datasheet AD582KH datasheet pdf AD582KH pinout AD582KH specifications AD582KH sample and hold amplifier AD582KH TO-100-10 AD582KH equivalent AD582KH replacement AD582KH vs AD582SH AD582KH application circuit AD582KH price AD582KH stock Analog Devices AD582KH

Related Components & Terms

Analog Devices AD582KH AD582KH/+ AD582SH AD582KD AD582 sample-and-hold amplifier operational amplifier low-leakage analog switch JFET integrating amplifier semiconductor integrated circuit analog signal acquisition data acquisition industrial process control laboratory instrumentation communications signal conditioning external holding capacitor acquisition time settling time input offset voltage bandwidth analog ground digital ground TO-100-10 MIL-STD-883
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details