ams OSRAM

AS7331-AQFM - 3-Channel UVA/B/C Spectral UV Sensor | ams OSRAM

Артикул: AS7331-AQFM ✓ Активен
В наличии Отправка в течение 1–3 рабочих дней
3.3 V Vdss 16-pin OLGA / TFLGA, SMD Package
От $7.87 USD / шт.
MOQ: 1 |
Цена обновлена: 2026-10-11
Оптовые цены
Кол-во Цена за ед. Итого
1 $9.69 $9,69
10 $9.21 $92,10
100 $8.72 $872,00
500 $8.28 $4.140,00
1.000 $7.87 $7.870,00
ℹ️ Все цены указаны в USD

AS7331-AQFM Обзор

The ams OSRAM AS7331-AQFM is a low-power, low-noise 3-channel spectral UV sensor that measures UVA, UVB and UVC radiation from 260 nm to 360 nm over an I2C interface, housed in a compact 16-pin OLGA (TFLGA) SMD package. According to the ams OSRAM AS7331 datasheet (DS001047), each channel uses a dedicated UV-optimized photodiode with on-chip interference filter technology to isolate its band without external filters.

A spectral UV sensor is an optical semiconductor that converts ultraviolet irradiance into a digital value. It sits within the sensor hierarchy: photodiode -> optical/ambient-light sensor -> spectral sensor -> environmental sensing subsystem, serving UV-index meters, disinfection monitors and laboratory instruments.

Key features include a high dynamic range adjustable up to 3.43E+10 via a 16-to-24-bit ADC, sensitivity up to 421 counts/(uW/cm2) in UVA, and a smallest LSB of 2.38 nW/cm2 at a 64 ms integration time. Irradiance responsivity is tunable through gain, conversion time and internal clock frequency, letting designers trade full-scale range against resolution. An integrated temperature sensor supports coarse compensation of thermal drift, and the I2C address is adjustable for multi-sensor buses.

Architecturally, the AS7331 converts photodiode currents through a low-noise analog front end into digital results, supporting continuous and triggered measurement modes with four low-power operating modes. The SYNC input enables externally synchronized sampling, while the RDY output (push-pull or open-drain) signals conversion completion - useful for deterministic sampling in process control.

Typical applications include UV index and personal exposure meters, UVC disinfection process monitoring, fluorescence detection, and UV measurement in mobile and wearable devices.

Design-wise, the glass or aperture area above the photodiodes must remain unobstructed, and the I2C bus should use appropriate pull-ups; the adjustable gain settings should be chosen so strong UVA sources do not saturate the ADC.

This page adds distributor pricing (as of 2026-10-11), drop-in alternative analysis, and design guidance beyond the manufacturer datasheet.

Аналоги без доработки для AS7331-AQFM — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.

Варианты в этой серии

Модели той же серии, совместимые без доработки с AS7331-AQFM (тот же форм-фактор и посадочное место) — отличается по Interface, Operating Modes, Package, Sensor Type, Supply Voltage.

ams OSRAM
Interface: I2C
Operating Modes: 4 (continuous and triggered measurement)
Package: OLGA-16, 3.65 mm x 2.6 mm (16-TFLGA)
Сравнить с AS7331-AQFM →

Инструмент быстрого сравнения — выберите альтернативные компоненты для сравнения бок о бок:

Для этого товара нет аналогов без доработки.

Запросить аналоги

AS7331-AQFM Максимальные параметры и электрические характеристики

Тип датчика 3-channel spectral UV sensor (UVA/UVB/UVC)
Spectral Range 260 nm to 360 nm
Каналы 3 (UVA, UVB, UVC) with interference filter technology
Интерфейс I2C (adjustable slave address)
Напряжение питания 3.3 V
ADC Resolution 16 to 24 bit
Dynamic Range up to 3.43E+10 (adjustable)
Sensitivity (UVA) up to 421 counts/(uW/cm2)
Smallest LSB 2.38 nW/cm2 (at 64 ms integration time)
Operating Modes 4 low-power modes; continuous and triggered measurement
Integrated Temperature Sensor Yes (coarse thermal compensation)
Synchronization SYNC input; RDY output (push-pull or open-drain)
Корпус 16-pin OLGA / TFLGA, SMD
Тип монтажа Surface Mount
Packaging Tape & Reel (LF T&R)

Руководство по цоколевке AS7331-AQFM в корпусе 16-pin olga / tflga, smd

Цоколевка для AS7331-AQFM (корпус 16-pin olga / tflga, smd). Нумерация выводов, функции и схемы подключения определены в техническом описании производителя. Обратитесь к нему для точного посадочного места и рекомендаций по пайке.

Схема цоколевки корпуса 16-pin olga / tflga, smd для AS7331-AQFM

Нет подробных данных о распиновке для AS7331-AQFM.

Обратитесь к даташиту для полной конфигурации выводов.

Типичное применение

AS7331-AQFM подходит для 6 применениеs: UV Index and Personal Exposure Meters, UVC Disinfection Process Monitoring, Fluorescence Detection, Mobile Device UV Measurement, Laboratory and Industrial UV Instrumentation, Smart Home and IoT UV Monitoring.

📱

UV Index and Personal Exposure Meters

The AS7331-AQFM fits solar UV exposure measurement because its three filtered channels (260-360 nm) separate UVA and UVB the way UV index weighting requires, with UVB isolation provided by on-chip interference filters rather than external optics. Its sensitivity up to 421 counts/(uW/cm2) in UVA and smallest LSB of 2.38 nW/cm2 (64 ms integration) let a wearable resolve faint diffuse daylight, while the adjustable 16-to-24-bit conversion chain prevents saturation under direct midday sun. In a wearable or handheld dosimeter, the sensor is polled over I2C in continuous mode at low duty cycle from one of its four low-power operating modes to preserve battery life, and the integrated temperature sensor provides coarse compensation of responsivity drift across outdoor temperature swings.

🏭

UVC Disinfection Process Monitoring

UVC germicidal systems need closed-loop verification that 260-280 nm dose is actually delivered, and the AS7331-AQFM's dedicated UVC channel with interference-filter isolation directly answers this. Its high dynamic range (up to 3.43E+10) lets one sensor design cover both close-range high-irradiance fixtures and distant low-irradiance verification points by reprogramming gain and conversion time. The SYNC input allows triggered sampling synchronized to lamp PWM, and the RDY output (push-pull or open-drain) gives the process controller deterministic conversion-complete timing. In a disinfection cabinet, the sensor is mounted where the load sits, read over I2C after each SYNC pulse, and dose is integrated in firmware from the nW/cm2-scale LSB resolution, enabling per-cycle pass/fail logging.

🧩

Fluorescence Detection

Fluorescence assays emit weak light against a dark background, and the AS7331-AQFM's 2.38 nW/cm2 smallest LSB at 64 ms integration gives it the sensitivity to resolve these faint signals in the UVA/UVB bands where many fluorophores are excited. Because gain, conversion time and internal clock frequency are independently programmable, the analog front end can be tuned per assay: high gain with long integration for low-concentration samples, reduced gain for concentrated ones, all without changing hardware. The triggered measurement mode lets the system fire the excitation source, then sample only during the emission window using the SYNC input, suppressing ambient background. The I2C interface with adjustable address supports multi-well or multi-channel reader architectures on one bus.

📱

Mobile Device UV Measurement

Smartphones and tablets increasingly expose UV sensing for weather and skin-health apps, and the AS7331-AQFM targets exactly this use case per the ams OSRAM product page. Its compact 16-pin OLGA SMD package fits the tight bezel and camera-island footprints of mobile hardware, while four low-power operating modes limit average current draw in always-listening exposure tracking. The I2C interface with adjustable address coexists with other phone sensors on the shared bus, and the 3.3 V supply matches common mobile rails. Integration effort is minimal: no external filters or optics are needed because each channel's interference filter is built into the die, so a smartphone maker gets calibrated three-band UV data from a single surface-mount part.

🔬

Laboratory and Industrial UV Instrumentation

Bench and inline instruments benefit from the AS7331-AQFM's quantifiable, programmable measurement chain: a 16-to-24-bit conversion with dynamic range up to 3.43E+10 and configurable LSB down to 2.38 nW/cm2 allows one design to span trace-level lamp leak checks and full-power irradiance calibration. In a laboratory dosimeter, the sensor sits behind a cosine-corrector, is triggered via SYNC for repeatability, and streams results over I2C to a logging MCU; the RDY flag enables gap-free acquisition. The integrated temperature sensor supports coarse thermal compensation between calibrations. Because channels are filtered on-die, no per-band optical alignment is required during manufacturing, which reduces production calibration cost compared to discrete-filter photodiode assemblies.

🌐

Smart Home and IoT UV Monitoring

IoT nodes that report UV conditions - garden sensors, pool-side stations, smart window controllers - can use the AS7331-AQFM as a drop-in three-band UV front end. Its I2C output connects directly to common wireless MCU platforms, and the adjustable I2C address permits several sensor nodes on one controller bus. The four low-power modes suit battery-operated nodes: the sensor sleeps between periodic conversions and uses RDY to wake the host only when data is ready, cutting average power. With an LSB of 2.38 nW/cm2 the node resolves overcast-day UV, while the extended dynamic range keeps readings valid in direct sun. Cloud dashboards can then display UVA/UVB/UVC separately, which a single broad-band UV sensor cannot provide.

What is the AS7331-AQFM and what does it measure?
The AS7331-AQFM is a low-power 3-channel spectral UV sensor from ams OSRAM that measures ultraviolet radiation in three separate bands: UVA, UVB and UVC. According to the ams OSRAM AS7331 datasheet, it covers 260 nm to 360 nm using three dedicated photodiodes with on-chip interference filters, converts the optical signals through a 16-to-24-bit ADC, and reports digital results over an I2C interface. It also integrates a temperature sensor for coarse compensation of thermal behavior, all in a compact 16-pin OLGA SMD package.
What is the spectral range of the AS7331-AQFM?
The AS7331-AQFM covers 260 nm to 360 nm, spanning UVC (260-280 nm), UVB (280-315 nm) and UVA (315-360 nm) regions. Per the ams OSRAM product documentation, each channel is optically isolated by built-in interference filter technology, so crosstalk between bands is minimized without any external filter optics. This three-band separation is what allows the sensor to distinguish germicidal UVC lamp output from solar UVA exposure in a single integrated device.
What interface does the AS7331-AQFM use and is the I2C address configurable?
The AS7331-AQFM communicates over I2C, and yes, its I2C slave address is adjustable. According to the ams OSRAM datasheet, the address can be changed so multiple AS7331 sensors can share a single bus - useful for arrays that monitor several disinfection zones or exposure points simultaneously. The device also provides a SYNC input for externally triggered conversions and an RDY output (configurable push-pull or open-drain) that signals when a conversion is complete.
What is the sensitivity and smallest LSB of the AS7331-AQFM?
The AS7331-AQFM achieves sensitivity up to 421 counts/(uW/cm2) in the UVA channel, and its smallest LSB is 2.38 nW/cm2 at a 64 ms integration time. According to the ams OSRAM datasheet, the dynamic range extends up to 3.43E+10 through a 16-to-24-bit conversion chain. Because gain, conversion time and internal clock frequency are all programmable, designers can trade full-scale range against resolution to match very dim fluorescence signals or very bright direct solar exposure.
How much does the AS7331-AQFM cost and where can I buy it?
The AS7331-AQFM is priced from approximately $9.69 (unit quantity) as of 2026-10-11, based on the LCSC Electronics listing. It is in stock at LCSC and available from DigiKey (AS7331-AQFM OLGA16 LF T&R), Mouser, and Arrow; Octopart lists 4 distributors for price comparison. XAIPART offers tiered quantity pricing - contact us for volume quotes above 1000 units. Prices vary by distributor and order quantity, so compare before ordering.
Is the AS7331-AQFM in stock and what is the typical lead time?
Yes, the AS7331-AQFM is in stock at major distributors as of 2026-10-11. DigiKey states 'Buy now, ships today' for the AS7331-AQFM OLGA16 LF T&R part, and LCSC lists the part as in-stock. Since stock levels change quickly for sensor ICs, verify current inventory on the distributor page before placing time-critical orders. For production volumes, confirm lead time with XAIPART or the distributor directly, as reel quantities may be allocated.
What is the best drop-in replacement for the AS7331-AQFM?
There is currently no verified pin-to-pin drop-in replacement for the AS7331-AQFM in its 16-pin OLGA/TFLGA package. This part is a unique ams OSRAM product: its 3-channel UVA/UVB/UVC channel set with on-chip interference filters in this footprint has no cross-brand equivalent confirmed in distributor cross-reference data as of 2026-10-11. Functional substitutes (such as discrete UVA/UVB/UVC photodiodes with separate ADCs) exist but require PCB redesign. Design the AS7331-AQFM in with second-source planning if supply resilience is critical.
Can the AS7331-AQFM be used for UVC disinfection monitoring?
Yes, UVC disinfection process monitoring is one of the primary applications of the AS7331-AQFM. Its dedicated UVC channel with interference-filter isolation responds to the 260-280 nm germicidal band emitted by low-pressure mercury and UVC LED sources. Per the ams OSRAM product page, the sensor enables verification that a disinfection cycle delivers sufficient UV dose, with the programmable gain and 16-to-24-bit conversion handling both close-range high-irradiance and distant low-irradiance installations. The RDY output supports deterministic process-control sampling.
Where can I download the AS7331-AQFM datasheet PDF?
The official AS7331 datasheet PDF is available from ams OSRAM at look.ams-osram.com (document AS7331 Spectral UVA/B/C Sensor, DS001047), and Mouser mirrors it at mouser.com/datasheet/2/588/amsOsram_AS7331_DS001047_1_00-3074216.pdf. The datasheet is a 72-page document covering electrical characteristics, register maps, and application guidance per the alldatasheet.com listing. Always prefer the manufacturer-hosted PDF to guarantee you have the latest revision before finalizing your design.
AS7331 vs LTR390-UV - which is better for UV index measurement?
The AS7331-AQFM is better suited for accurate UV index measurement because it spectrally separates UVA, UVB and UVC bands with interference filters, while the LuminOpto/ams LTR390 provides a broad-band UV response with less band discrimination. Per the ams OSRAM datasheet, the AS7331 achieves an LSB as small as 2.38 nW/cm2 and covers 260-360 nm with three independent channels - enabling direct UVB weighting for UV index calculations. The LTR390 is lower cost and smaller, but for meteorological-grade UV index or UVC safety monitoring the AS7331's spectral separation is the decisive advantage.
When should I choose the AS7331-AQFM over a discrete UV photodiode plus ADC?
Choose the AS7331-AQFM when you need calibrated multi-band UV measurement with minimal optical design effort. The integrated interference filters on each of its three photodiodes deliver band isolation that discrete photodiodes achieve only with external filters, which add cost, size and alignment tolerances. Its 16-to-24-bit ADC, programmable gain, temperature sensor and I2C output replace an entire analog front end. Choose a discrete photodiode only when you need a custom spectral response, extreme radiation hardness, or cost points below the AS7331's roughly $9.69 unit price as of 2026-10-11.
Is the AS7331-AQFM suitable for wearable UV exposure devices?
Yes, the AS7331-AQFM is suitable for mobile and wearable UV radiation measurement - this is an explicitly listed application on the ams OSRAM product page. Its low-power design with four operating modes conserves battery in always-on exposure tracking, and its 16-pin OLGA compact SMD package fits space-constrained wearable housings. The high sensitivity (up to 421 counts/(uW/cm2) in UVA) enables meaningful readings from weak diffuse daylight, while the adjustable dynamic range prevents saturation at the beach or high altitude.
What are the key specifications of the AS7331-AQFM that engineers should know?
Key AS7331-AQFM specifications: 3-channel spectral UV sensing (UVA/UVB/UVC) over 260-360 nm; I2C interface with adjustable slave address; 3.3 V supply; 16-to-24-bit ADC with dynamic range up to 3.43E+10; sensitivity up to 421 counts/(uW/cm2) in UVA; smallest LSB 2.38 nW/cm2 at 64 ms integration; four low-power operating modes with continuous and triggered measurement; SYNC input and RDY output; integrated temperature sensor; 16-pin OLGA/TFLGA SMD package. Source: ams OSRAM AS7331 datasheet (DS001047).
What is the best ams OSRAM equivalent for the AS7331-AQFM from another brand?
No cross-brand equivalent offers the same 3-channel UVA/UVB/UVC spectral separation as the ams OSRAM AS7331-AQFM in the same package. The closest functional alternatives from other vendors are broad-band UV sensors such as the LTR390-UV (ams), or Vishay's VEML6070/VEML6075-era UV index sensors, but these do not isolate UVC and use different packages and pinouts, so none qualify as drop-in replacements. For designs locked to the AS7331 footprint, sole-sourcing from ams OSRAM ( stocked at DigiKey, Mouser, Arrow, LCSC) is currently the only option.
How do I design the I2C bus and use SYNC/RDY with the AS7331-AQFM?
Connect the AS7331-AQFM to your MCU via standard I2C with appropriate pull-up resistors (typically 2.2k to 10k ohm depending on bus capacitance), and use the adjustable slave address if you place multiple sensors on one bus. For deterministic sampling, drive the SYNC input with an external pulse to trigger conversions - useful for synchronizing measurement with lamp modulation in disinfection systems. Configure the RDY output as push-pull for noise immunity or open-drain for shared interrupt lines, per the Adafruit AS7331 pinout documentation. Read results only after RDY asserts to avoid stale data.
Where can I find the AS7331-AQFM pinout?
The AS7331-AQFM pinout is documented in the ams OSRAM AS7331 datasheet (DS001047, 72 pages) and in practical form on the Adafruit AS7331 learn guide (learn.adafruit.com), which identifies the key pins: VDD, GND, SDA, SCL, SYNC (external trigger input) and RDY (data-ready output, software-configurable push-pull or open-drain). The remaining pins support the 3-channel photodiode front end and configuration options. LCSC also provides pinout diagrams alongside the datasheet download for the AS7331-AQFM product page.

Справочные инженерные данные для AS7331-AQFM — сравнение, рекомендации по проектированию и информация о соответствии.

Руководство по выбору

Choose the AS7331-AQFM when your design needs quantified, band-separated UV measurement: UVC disinfection dose verification, UV index wearables, fluorescence readers, or multi-band IoT monitoring. Its on-die interference filters deliver the UVA/UVB/UVC isolation that broad-band sensors (LTR390-UV, VEML6070-class) cannot, and its 16-to-24-bit programmable chain spans 2.38 nW/cm2 resolution to a 3.43E+10 dynamic range, covering both trace and full-sun irradiance in one footprint. Accept the trade-offs: at roughly $9.69 unit cost (as of 2026-10-11) it costs more than broad-band UV sensors, and it is single-sourced from ams OSRAM with no verified drop-in replacement - plan buffer stock. If you only need a coarse UV index number at minimum BOM cost, a broad-band sensor suffices; if band identity or UVC safety compliance matters, the AS7331-AQFM is the correct choice.

Сравнение с аналогами

Параметр Этот товар
Package 16-pin OLGA / TFLGA, SMD
Brand ams OSRAM
Spectral Range 260 nm to 360 nm (UVA/UVB/UVC)
Channels 3 (UVA, UVB, UVC), interference-filtered
ADC Resolution 16 to 24 bit
Dynamic Range up to 3.43E+10
Interface I2C, adjustable address
Sensitivity (UVA) up to 421 counts/(uW/cm2)
Smallest LSB 2.38 nW/cm2 at 64 ms integration
Unit Price (qty 1, as of 2026-10-11) $9.69 (LCSC)

Ключевые отличия

  • True 3-band spectral separation on-die (против LTR390-UV)
  • Extreme dynamic range with programmable resolution (против discrete UV photodiode + ADC)
  • Trade-off: single-sourced niche package (против LTR390-UV)

Заметки по проектированию

Place the AS7331-AQFM so its optical aperture has an unobstructed field of view, and keep the OLGA-16 land pattern per the ams OSRAM datasheet footprint recommendation. Because the interference filters are on-die, no external filter glass is needed, but avoid placing UV-absorbing cover materials (polycarbonate blocks UVC strongly; use quartz or UV-transmitting acrylic if a window is required). Keep the sensor away from board edges where solder wicking could contaminate the window during reflow.

Use appropriate I2C pull-up resistors (typically 2.2k to 10k ohm depending on bus capacitance) and keep the bus short. Take advantage of the adjustable I2C address when networking multiple AS7331 sensors. Route the RDY line as a dedicated interrupt to the host MCU and configure it open-drain if it shares an interrupt line with other devices; use push-pull for lowest latency in deterministic triggered-sampling systems driven from SYNC.

Choose gain and conversion time so expected maximum irradiance does not saturate the ADC: direct sunlight UVA can exceed 1000 uW/cm2, so verify headroom against the 421 counts/(uW/cm2) maximum sensitivity setting. Do not rely on the integrated temperature sensor for precision correction - it is specified for coarse compensation only, so perform system-level calibration for demanding photometric use. Confirm the exact supply voltage and operating temperature range from the datasheet before finalizing power-tree design.

Информация о соответствии

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Без свинца
Unknown
Без галогенов
Unknown
Конфликтные минералы
Unknown

DigiKey listing shows 'OLGA16 LF T&R' suffix; LF is typically the lead-free designation but explicit RoHS/REACH compliance statements were not present in the verified data - confirm on the ams OSRAM product page.

Данные проверены: 2026-10-11 — данные проверены и курируются командой компонентной инженерии XAIPART

Похожие запросы

AS7331-AQFM AS7331-AQFM datasheet ams OSRAM AS7331 spectral UV sensor AS7331 UVA UVB UVC sensor I2C AS7331 OLGA16 package pinout UVC disinfection monitoring sensor IC AS7331 vs LTR390 UV sensor comparison AS7331-AQFM drop-in replacement equivalent buy AS7331-AQFM price what is the spectral range of AS7331 UV index wearable sensor 3.3V I2C AS7331-AQFM in stock lead time

Связанные компоненты & термины

ams OSRAM AS7331-AQFM AS7331 spectral UV sensor UV sensor optical sensor ambient light sensor family UVA UVB UVC I2C OLGA-16 TFLGA surface mount (SMD) interference filter technology 16-24 bit ADC irradiance responsivity UV index measurement UVC disinfection monitoring fluorescence detection DS001047 RoHS tape and reel DigiKey LCSC
Быстрый запрос цены (RFQ)
Заполните все данные — наша команда продаж ответит в течение 24 часов
Артикул Производитель Корпус QTY Целевая цена Итого
Итого: $0.00 USD
✓
Запрос цены отправлен!

Мы ответим на ваш email в течение 24 часов

1
RFQ отправлен
2
Предложение получено
3
Заказ оформлен
4
Оплата
5
Отправлено
6
Доставлено
Просмотреть детали RFQ