Analog Devices

AD625CDZ - 25 MHz Instrumentation Amplifier | Analog Devices

MPN: AD625CDZ ✗ اختتامِ زندگی
+5 V Vdss 10 nA Id 16-CDIP, 0.300 inch pitch, 7.62 mm body Package
MOQ: 1 |

AD625CDZ جائزہ

The Analog Devices AD625CDZ is a single-circuit precision instrumentation amplifier in a 16-pin CDIP package, designed for signal conditioning applications that require programmable gain, high common-mode rejection, and low-noise differential measurement. Its listed gain-bandwidth product is 25 MHz, with a -3 dB bandwidth of 650 kHz and a slew rate of 5 V/us. The AD625CDZ operates from a single +5 V supply according to the manufacturer product description.

An instrumentation amplifier is a specialized amplifier category used to amplify small differential sensor signals while rejecting large common-mode voltages. In the broader signal-chain hierarchy, an instrumentation amplifier sits between sensors such as strain gauges, bridge transducers, thermocouples, and high-impedance sensing front ends, and the analog-to-digital converter or downstream measurement circuitry. The AD625 series is intended for applications requiring nonstandard gains, precision gain adjustment, and software-controlled measurement systems.

The AD625CDZ combines a 25 MHz gain-bandwidth product with programmable gain capability and a 650 kHz small-signal bandwidth. Its input bias current is listed at 10 nA, supporting high-impedance sensor interfaces, while the 5 V/us slew rate helps preserve signal fidelity in multiplexed measurement systems. The device is offered in a 16-CDIP through-hole package, which is useful for legacy laboratory, industrial, and instrumentation equipment where through-hole assembly and serviceability are preferred over a surface-mount land pattern.

Compared with ordinary precision op amps, the AD625CDZ provides a matched internal resistor network and integrated gain-setting arrangement, reducing the number of external precision components required in many gain configurations. The low-noise input stage and programmable gain are particularly useful for bridge-based measurement, biomedical instrumentation, current-loop receivers, and laboratory data-acquisition systems. The 650 kHz -3 dB bandwidth makes it suitable for signal bandwidths well below the unity-gain-frequency limit while preserving the flexibility to set different gains in software.

Typical applications include weighing systems using load cells, industrial process monitoring, laboratory measurement equipment, and medical or diagnostic instrumentation. In a bridge or strain-gauge circuit, the amplifier converts a small differential excitation error into a level suitable for an ADC while the internal matched network improves rejection of common-mode pickup. In a software-controlled measurement system, programmable gain allows the same amplifier to handle multiple input ranges without redesigning the analog front end.

When laying out a board around the AD625CDZ, keep the input and feedback-network routing short and symmetrical, provide stable bypass capacitance at the supply pins, and avoid long unprotected traces adjacent to high-current switching nodes. Because the package is a through-hole CDIP rather than a surface-mount package, verify the 16-pin mechanical drawing and pin numbering against the manufacturer datasheet before fabrication. This page combines manufacturer product information, distributor listings, package details, and design guidance for engineers evaluating the AD625CDZ.

کے لیے ڈراپ اِن متبادل AD625CDZ — یکساں پیکیج، پن سے پن مطابقت پذیر۔ مختلف پیکیج والے پرزے جن کے لیے PCB دوبارہ کام درکار ہو، شامل نہیں ہیں۔

اس سیریز میں مختلف ورژن

اسی سیریز کے ماڈلز جو ڈراپ اِن مطابقت رکھتے ہیں AD625CDZ (یکساں فارم فیکٹر اور فٹ پرنٹ) — میں مختلف Package, Number of Circuits, Product Type, Maximum Low Nonlinearity, Maximum Offset Voltage.

Analog Devices
Package: 16-CDIP
Product Type: Programmable-gain instrumentation amplifier
Maximum Low Nonlinearity: 0.001% max
موازنہ کریں AD625CDZ →
Analog Devices
Package: 16-CDIP, 0.300-inch (7.62 mm) width
Number of Circuits: 1
Maximum Low Nonlinearity: 0.001%
موازنہ کریں AD625CDZ →
Analog Devices
Package: 16-CDIP
Analog Devices
Package: 16-CDIP (0.300 inch, 7.62 mm)
Maximum Low Nonlinearity: 0.001%
موازنہ کریں AD625CDZ →
Analog Devices
Package: 16-lead ceramic dual-in-line package (16-CDIP)
Product Type: Programmable-gain instrumentation amplifier
Maximum Offset Voltage: 25 µV
موازنہ کریں AD625CDZ →

AD625BDZ

✅ ڈراپ-اِن
Analog Devices
📦 16-CDIP
Instrumentation · 1 circuit · Up to 10,000 · 0.02% · 5 ppm/°C · 0.001% · 25 MHz · 5 V/µs

قیمت کے لیے رابطہ کریں

ڈیٹا شیٹ دیکھیں →

AD625SD

✅ ڈراپ-اِن
Analog Devices
📦 16-CDIP
Programmable-gain instrumentation amplifier · 1 channel · 16-lead CDIP · 16 pins · 650 kHz · 5 V/us · 3.5 mA · 70 dB

قیمت کے لیے رابطہ کریں

ڈیٹا شیٹ دیکھیں →

AD625BD/+

✅ ڈراپ-اِن
Analog Devices
📦 16-CDIP
Programmable Gain Instrumentation Amplifier · 1 circuit · 16-CDIP · Programmable gain · Differential input

قیمت کے لیے رابطہ کریں

ڈیٹا شیٹ دیکھیں →

AD625AD

✅ ڈراپ-اِن
Analog Devices
📦 16-CDIP
Programmable-gain instrumentation amplifier · 1 circuit · 1 to 10,000 · 0.02% max · 5 ppm/°C max · 0.001% max · 200 µV · 4 nV/√Hz at 1 kHz

قیمت کے لیے رابطہ کریں

ڈیٹا شیٹ دیکھیں →

AD625BZ

✅ ڈراپ-اِن
📦 16-CDIP
AD625 family ordering variant in the same 16-CDIP format; gain and temperature details require comparison with the AD625CDZ datasheet

📋 حوالہ جاتی متبادل (کیٹلاگ میں نہیں)

AD625CDZ زیادہ سے زیادہ ریٹنگز اور برقی خصوصیات

Device Type Instrumentation amplifier
Number of Circuits 1 circuit
Gain-Bandwidth Product 25 MHz
-3 dB Bandwidth 650 kHz
Slew Rate 5 V/us
Input Bias Current 10 nA
سپلائی وولٹیج +5 V
پیکیج 16-CDIP, 0.300 inch pitch, 7.62 mm body
ماؤنٹنگ ٹائپ Through-hole
پنز کی تعداد 16
Product Type Programmable gain instrumentation amplifier
Product Status Active
RoHS اسٹیٹس Listed as RoHS on distributor product information

AD625CDZ 16-cdip, 0.300 inch pitch, 7.62 mm body پن کنفیگریشن گائیڈ

AD625CDZ (16-cdip, 0.300 inch pitch, 7.62 mm body پیکیج) کے لیے پن کنفیگریشن۔ اس اینالاگ کمپوننٹ میں اِن پٹ، آؤٹ پٹ اور پاور سپلائی پنز شامل ہیں۔ آفسیٹ نل، کمپنسیشن اور اِن ایبل پن کنفیگریشنز کے لیے مینوفیکچرر کے ڈیٹا شیٹ سے رجوع کریں۔ سگنل کنڈیشننگ اور ایمپلیفائر سرکٹس کے لیے مثالی۔

AD625CDZ کے لیے 16-cdip, 0.300 inch pitch, 7.62 mm body پیکیج پن آؤٹ ڈایاگرام

کے لیے تفصیلی پن آؤٹ ڈیٹا دستیاب نہیں AD625CDZ.

رجوع کریں ڈیٹا شیٹ مکمل پن کنفیگریشن کے لیے۔

عام استعمالات

AD625CDZ کے لیے موزوں ہے 6 ایپلیکیشنs: Strain-Gauge and Load-Cell Measurement, Laboratory Data-Acquisition Systems, Industrial Process-Control Front Ends, Medical and Diagnostic Instrumentation, Current-Loop and Low-Level Receiver Circuits, Legacy Instrument Repair and Extension.

⚖️

Strain-Gauge and Load-Cell Measurement

The AD625CDZ suits bridge-based strain-gauge and load-cell front ends where a small differential signal must be amplified while pickup from the excitation source is rejected. Its 650 kHz -3 dB bandwidth handles relatively fast mechanical or dynamic load events, while the 25 MHz gain-bandwidth product provides headroom for programmable gain settings. The 10 nA input bias current helps limit sensor loading. Use matched routing from the bridge to the input pins and place the amplifier close to the sensor connector to minimize parasitic differential pickup.

🧪

Laboratory Data-Acquisition Systems

The AD625CDZ is appropriate for laboratory instrumentation that measures low-level differential signals across several programmable input ranges. Programmable gain allows a single analog front end to cover signals that would otherwise require separate amplifier selections, and the 25 MHz gain-bandwidth product supports gain configurations below the device's 650 kHz -3 dB bandwidth. The single +5 V supply simplifies laboratory supply design, while the 16-CDIP package supports through-hole prototyping, repair, and modular instrument construction.

🏭

Industrial Process-Control Front Ends

The AD625CDZ can condition small differential process signals in industrial measurement equipment where a 5 V analog supply is available. Its instrumentation-amplifier architecture is preferable to a general-purpose op amp when the source includes substantial common-mode voltage or requires matched internal gain resistors. The 650 kHz bandwidth accommodates many process-control signals without entering the high-frequency region where board layout becomes more difficult. Add input protection and isolation as required by the field wiring environment.

💊

Medical and Diagnostic Instrumentation

The AD625CDZ can serve as the analog front end in low-level biomedical measurement systems where differential sensing, programmable gain, and low input bias current are important. Its 10 nA input bias current reduces disturbance of high-impedance transducers, while the 650 kHz bandwidth is suitable for many physiological and laboratory signals. The device's through-hole CDIP construction is also useful for legacy medical instruments and serviceable laboratory equipment. Confirm the applicable medical-grade qualification and isolation requirements for the final system.

📡

Current-Loop and Low-Level Receiver Circuits

The AD625CDZ is suitable for current receivers that must preserve small differential information while rejecting voltage common to both input terminals. Its low 10 nA input bias current is beneficial when the source impedance is high, and the 25 MHz gain-bandwidth product gives design flexibility across moderate gain settings. Connect the receiver input pair with equal trace lengths and avoid routing them beneath digital or switching circuitry. The 5 V supply architecture keeps the analog rail straightforward in compact measurement modules.

🔧

Legacy Instrument Repair and Extension

The AD625CDZ is a practical choice for repairing or extending legacy laboratory and industrial instruments that use the AD625 family in a 16-CDIP through-hole footprint. Its listed 650 kHz bandwidth, 5 V/us slew rate, and 10 nA input bias current align with the original AD625 instrumentation-amplifier role. Because the manufacturer marks the AD625 as not recommended for new designs, this application is best treated as a maintenance or installed-base decision. Confirm pin functions, gain configuration, and the required temperature grade before substitution.

What is the AD625CDZ?
The AD625CDZ is a single-circuit programmable-gain instrumentation amplifier from Analog Devices. It is specified for a 25 MHz gain-bandwidth product, 650 kHz -3 dB bandwidth, 5 V/us slew rate, and 10 nA input bias current. The device uses a 16-CDIP through-hole package and is intended for precision differential signal conditioning, including bridge, sensor, laboratory, and industrial measurement systems.
What is the operating voltage of the AD625CDZ?
The AD625CDZ operates from a single +5 V supply according to the manufacturer product information. The distributor technical listing identifies it as a 1-circuit instrumentation amplifier with a 25 MHz gain-bandwidth product and 650 kHz -3 dB bandwidth. Confirm the complete supply-voltage limits, decoupling requirements, and rail-to-rail operating margins in the manufacturer datasheet before finalizing the power-supply design.
Where can I download the AD625CDZ datasheet?
The official AD625 product page provides the manufacturer datasheet and supporting product documentation at https://www.analog.com/en/products/ad625.html. The page identifies the AD625 as a programmable-gain precision instrumentation amplifier and also provides product-selection information. Use the AD625CDZ ordering suffix to confirm the 16-CDIP package and temperature-grade variant in the datasheet ordering table.
Where can I find the AD625CDZ pinout?
The AD625CDZ pinout is published in the manufacturer datasheet for the AD625 family, while the package is identified as a 16-CDIP in the manufacturer product listing. Use the pin-description table and package drawing in the AD625 datasheet when assigning PCB tracks, because the pin names and electrical functions are authoritative for the specific ordering suffix. The AD625CDZ has 16 through-hole pins in the CDIP package.
Is the AD625CDZ still available for new designs?
The Analog Devices product page states that the AD625 is not recommended for new designs. Distributor listings identify AD625CDZ as an active product with inventory available, so the distinction is important: existing production, repair, and extension programs can still source the device, but new designs should evaluate a currently recommended instrumentation amplifier. The manufacturer page is the controlling lifecycle reference.
What is the bandwidth of the AD625CDZ?
The AD625CDZ has a listed -3 dB bandwidth of 650 kHz and a gain-bandwidth product of 25 MHz. The two figures describe different operating conditions, with the -3 dB value representing the measured bandwidth under the specified test conditions and the gain-bandwidth product describing the internal gain and bandwidth relationship. The AD625CDZ is therefore most suitable for measurement signals whose required bandwidth remains below 650 kHz.
What is the input bias current of the AD625CDZ?
The AD625CDZ has a listed input bias current of 10 nA. This low bias current helps limit loading of high-impedance sensors such as strain gauges, electrochemical cells, and other measurement bridges. The exact bias-current behavior should be checked against the AD625 datasheet for the selected gain and supply conditions, since bias current and input impedance vary with operating configuration.
Can the AD625CDZ be used for strain-gauge measurements?
Yes, the AD625CDZ is well suited to strain-gauge and bridge-measurement front ends because it is a programmable-gain instrumentation amplifier with a 25 MHz gain-bandwidth product and 650 kHz -3 dB bandwidth. Its differential-input architecture and 10 nA input bias current support low-level bridge signals, while the through-hole CDIP package remains practical for laboratory and industrial equipment.
How does the AD625CDZ compare with a precision op amp?
The AD625CDZ differs from a discrete precision op-amp circuit by integrating the matched gain-setting network and differential amplification function in one package. The AD625CDZ provides programmable gain for measurement systems, whereas a discrete op-amp design requires external resistors and additional matching or trimming. This integration simplifies firmware-controlled gain ranges, but the complete external support network and package requirements still depend on the AD625 datasheet.
What is the AD625CDZ slew rate?
The AD625CDZ has a listed slew rate of 5 V/us. This specification controls how quickly the output can follow a large input step and is useful when estimating settling behavior in gain-switched measurement systems. The AD625CDZ also has a 650 kHz -3 dB bandwidth, so a design with very high-frequency components should be checked against both bandwidth and slew-rate limits.
Is the AD625CDZ suitable for a 24 V industrial control system?
The AD625CDZ is identified as a single +5 V device, so it should not be connected directly to a 24 V industrial supply. Use a regulated 5 V rail and add appropriate protection, isolation, and signal-conditioning stages for field inputs. The AD625CDZ is appropriate for 5 V laboratory and instrumentation systems, but its exact supply limits and absolute maximum ratings must be confirmed in the manufacturer datasheet.
What is the best drop-in replacement for the AD625CDZ?
The closest documented same-family alternatives are AD625BDZ and AD625SD, both compared against the AD625CDZ in the cross-reference results. AD625BDZ is listed as an ADI 16-CDIP device with the same 650 kHz bandwidth and 5 V/us slew rate, while AD625SD is also an ADI 16-CDIP instrumentation amplifier with the same listed bandwidth. Confirm temperature grade, gain settings, and supply details before substituting.
Can AD625BDZ replace the AD625CDZ?
AD625BDZ is a strong candidate for replacement because the comparison data identifies it as an ADI 16-CDIP instrumentation amplifier with the same 650 kHz -3 dB bandwidth and 5 V/us slew rate as the AD625CDZ. The CDIP pin count and package family also match. The AD625BD/ comparison result further confirms the family relationship, but the exact gain-control and temperature-grade details should be checked before production use.
What is the difference between AD625CDZ and AD625SD?
The AD625SD and AD625CDZ are both ADI instrumentation amplifiers in 16-CDIP packages, and the comparison data lists identical 650 kHz bandwidth and 5 V/us slew-rate figures. The meaningful differences are likely in the ordering suffix and associated temperature or qualification details, which must be read from the AD625 datasheet. For a drop-in decision, verify every pin function and the exact gain-setting configuration rather than relying on the family name alone.
How should I design the PCB around the AD625CDZ?
Route the differential input and gain-control connections symmetrically and keep them short to reduce parasitic pickup and imbalance. Place supply bypass capacitors close to the device pins, provide a clean analog ground return, and keep switching or high-current traces away from the input path. Because the AD625CDZ is a 16-CDIP through-hole device, verify the mechanical footprint and pin numbering against the CDIP drawing in the AD625 datasheet before releasing the layout.
How do I buy AD625CDZ and check current lead time?
Use the Request a Quote form on this page to request AD625CDZ availability, current pricing, and a delivery commitment for your required quantity. The manufacturer page states that the AD625 is not recommended for new designs, while distributor listings show inventory for the exact AD625CDZ ordering suffix. Because stock and lead time change continuously, confirm the quantity, package, and date code through the quotation request.

کے لیے انجینئرنگ ریفرنس ڈیٹا AD625CDZ — موازنہ، ڈیزائن رہنمائی، اور تعمیل کی معلومات۔

انتخاب کی گائیڈ

Choose the AD625CDZ for a 5 V instrumentation design that needs a programmable-gain differential amplifier in a 16-CDIP through-hole package, especially when servicing or extending legacy laboratory or industrial equipment. AD625BDZ is the closest documented same-family service alternative because it is also an ADI 16-CDIP device with a 650 kHz -3 dB bandwidth and 5 V/us slew rate; verify the temperature grade and gain configuration before substitution. AD625SD offers the same documented package and key AC figures but should be checked against the ordering table for application-specific qualification. For new designs, however, Analog Devices states that the AD625 is not recommended for new designs, so a currently recommended instrumentation amplifier is normally the better platform choice. The AD625CDZ remains most defensible when maintaining an installed base, replicating an approved design, or using a verified component revision within the same footprint.

متبادلات کے ساتھ موازنہ

پیرامیٹر یہ پروڈکٹ AD625BDZ AD625SD AD625BD AD625 AD625BZ
Brand Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices
Package 16-CDIP 16-CDIP 16-CDIP 16-CDIP 16-CDIP 16-CDIP
Amplifier Type Programmable gain instrumentation amplifier Instrumentation amplifier Instrumentation amplifier Instrumentation amplifier Instrumentation amplifier Instrumentation amplifier
Number of Circuits 1 1 1 1 1 1

اہم امتیازی خصوصیات

  • Integrated programmable-gain instrumentation-amplifier function (بمقابلہAD625BDZ)
  • Through-hole 16-CDIP construction for serviceable legacy equipment (بمقابلہAD625SD)
  • High gain-bandwidth product for programmable measurement gain (بمقابلہAD625)

ڈیزائن نوٹس

Keep the differential input path short and symmetric. Route the two input conductors as a closely matched pair, terminate unused inputs according to the datasheet recommendations, and avoid placing the pair beside switching-node copper. The 10 nA input bias current is favorable for high-impedance sources, but board leakage and contamination can still be significant, so clean boards and guarded input structures are valuable in precision measurement systems.

The AD625CDZ uses a single +5 V supply. Place the required bypass capacitors immediately adjacent to the supply pins and keep the return path continuous and low impedance. Because the CDIP package has long through-hole leads, excessive bypass capacitance can create undesirable lead inductance; follow the manufacturer datasheet's recommended capacitance and placement rather than adding large capacitors at the device without accounting for stability.

Do not assume that every AD625 ordering suffix is interchangeable. AD625BDZ and AD625SD are documented as 16-CDIP alternatives with the same listed bandwidth and slew rate, but temperature grade, gain configuration, and qualification details must be checked against the exact ordering table. For new designs, note that Analog Devices marks the AD625 as not recommended for new designs and evaluate a currently recommended instrumentation amplifier instead.

The AD625CDZ's 650 kHz -3 dB bandwidth is the practical signal-bandwidth limit, while the 25 MHz gain-bandwidth product describes the internal gain-bandwidth relationship. Avoid treating the higher figure as usable closed-loop measurement bandwidth. Check settling time, slew rate, and gain-dependent bandwidth together when designing multiplexed acquisition paths or driving an ADC.

تعمیل کی معلومات

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Applicable
لیڈ فری
Unknown
ہیلوجن فری
Unknown
کنفلیکٹ منرلز
Unknown

A distributor product listing identifies AD625CDZ as RoHS. The Analog Devices product page identifies the AD625 as not recommended for new designs. No additional REACH, halogen-free, or conflict-minerals statement was found for the exact ordering suffix.

ڈیٹا کی تصدیق کی تاریخ: 2026-11-18 — ڈیٹا XAIPART کی کمپوننٹ انجینئرنگ ٹیم کے ذریعے تصدیق شدہ اور ترتیب شدہ

متعلقہ تلاشیں

AD625CDZ datasheet AD625CDZ datasheet pdf AD625CDZ pinout AD625CDZ specifications AD625CDZ 16-CDIP Analog Devices AD625CDZ AD625CDZ instrumentation amplifier AD625CDZ replacement AD625CDZ vs AD625BDZ AD625CDZ vs AD625SD AD625CDZ drop-in substitute AD625CDZ strain gauge amplifier AD625CDZ laboratory instrument AD625CDZ buy AD625CDZ price and stock

متعلقہ اجزاء اور اصطلاحات

Analog Devices AD625CDZ AD625BDZ AD625SD AD625 programmable gain instrumentation amplifier instrumentation amplifier precision analog signal conditioner differential amplifier common-mode rejection gain-bandwidth product input bias current slew rate 16-CDIP through-hole package single +5 V supply strain gauge load cell laboratory data acquisition bridge measurement RoHS
فوری کوٹ RFQ
مکمل تفصیلات بھریں — ہماری سیلز ٹیم 24 گھنٹوں میں جواب دے گی
پارٹ نمبر مینوفیکچرر پیکج QTY ہدف قیمت کل رقم
✓
کوٹ جمع ہو گیا!

ہم 24 گھنٹوں کے اندر آپ کے ای میل کا جواب دیں گے

1
RFQ جمع ہو گیا
2
کوٹ موصول ہو گیا
3
آرڈر دے دیا گیا
4
ادائیگی
5
بھیج دیا گیا
6
ڈیلیور شدہ
RFQ تفصیلات دیکھیں