AD625CDZ - 25 MHz Instrumentation Amplifier | Analog Devices
MPN: AD625CDZ ✗ 停產AD625CDZ 概覽
An instrumentation amplifier is a specialized amplifier category used to amplify small differential sensor signals while rejecting large common-mode voltages. In the broader signal-chain hierarchy, an instrumentation amplifier sits between sensors such as strain gauges, bridge transducers, thermocouples, and high-impedance sensing front ends, and the analog-to-digital converter or downstream measurement circuitry. The AD625 series is intended for applications requiring nonstandard gains, precision gain adjustment, and software-controlled measurement systems.
The AD625CDZ combines a 25 MHz gain-bandwidth product with programmable gain capability and a 650 kHz small-signal bandwidth. Its input bias current is listed at 10 nA, supporting high-impedance sensor interfaces, while the 5 V/us slew rate helps preserve signal fidelity in multiplexed measurement systems. The device is offered in a 16-CDIP through-hole package, which is useful for legacy laboratory, industrial, and instrumentation equipment where through-hole assembly and serviceability are preferred over a surface-mount land pattern.
Compared with ordinary precision op amps, the AD625CDZ provides a matched internal resistor network and integrated gain-setting arrangement, reducing the number of external precision components required in many gain configurations. The low-noise input stage and programmable gain are particularly useful for bridge-based measurement, biomedical instrumentation, current-loop receivers, and laboratory data-acquisition systems. The 650 kHz -3 dB bandwidth makes it suitable for signal bandwidths well below the unity-gain-frequency limit while preserving the flexibility to set different gains in software.
Typical applications include weighing systems using load cells, industrial process monitoring, laboratory measurement equipment, and medical or diagnostic instrumentation. In a bridge or strain-gauge circuit, the amplifier converts a small differential excitation error into a level suitable for an ADC while the internal matched network improves rejection of common-mode pickup. In a software-controlled measurement system, programmable gain allows the same amplifier to handle multiple input ranges without redesigning the analog front end.
When laying out a board around the AD625CDZ, keep the input and feedback-network routing short and symmetrical, provide stable bypass capacitance at the supply pins, and avoid long unprotected traces adjacent to high-current switching nodes. Because the package is a through-hole CDIP rather than a surface-mount package, verify the 16-pin mechanical drawing and pin numbering against the manufacturer datasheet before fabrication. This page combines manufacturer product information, distributor listings, package details, and design guidance for engineers evaluating the AD625CDZ.
直接替換替代品,適用於 AD625CDZ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: AD625CDZ (相同外形與佔位) — 差異在於 Package, Number of Circuits, Product Type, Maximum Low Nonlinearity, Maximum Offset Voltage.
AD625BDZ
✅ 直接替換聯絡詢價
查看資料表 →AD625SD
✅ 直接替換聯絡詢價
查看資料表 →AD625BD/+
✅ 直接替換聯絡詢價
查看資料表 →AD625AD
✅ 直接替換聯絡詢價
查看資料表 →AD625BZ
✅ 直接替換📋 參考替代品(不在目錄中)
AD625CDZ 最大額定值與電氣特性
| Device Type | Instrumentation amplifier |
| Number of Circuits | 1 circuit |
| Gain-Bandwidth Product | 25 MHz |
| -3 dB Bandwidth | 650 kHz |
| Slew Rate | 5 V/us |
| Input Bias Current | 10 nA |
| 供應電壓 | +5 V |
| 封裝 | 16-CDIP, 0.300 inch pitch, 7.62 mm body |
| 安裝類型 | Through-hole |
| 腳位數 | 16 |
| Product Type | Programmable gain instrumentation amplifier |
| Product Status | Active |
| RoHS 狀態 | Listed as RoHS on distributor product information |
AD625CDZ 16-cdip, 0.300 inch pitch, 7.62 mm body 腳位配置指南
AD625CDZ(16-cdip, 0.300 inch pitch, 7.62 mm body 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: AD625CDZ.
請參閱 資料表 以查看完整腳位配置。
典型應用
AD625CDZ 適用於 6 應用s: Strain-Gauge and Load-Cell Measurement, Laboratory Data-Acquisition Systems, Industrial Process-Control Front Ends, Medical and Diagnostic Instrumentation, Current-Loop and Low-Level Receiver Circuits, Legacy Instrument Repair and Extension.
Strain-Gauge and Load-Cell Measurement
The AD625CDZ suits bridge-based strain-gauge and load-cell front ends where a small differential signal must be amplified while pickup from the excitation source is rejected. Its 650 kHz -3 dB bandwidth handles relatively fast mechanical or dynamic load events, while the 25 MHz gain-bandwidth product provides headroom for programmable gain settings. The 10 nA input bias current helps limit sensor loading. Use matched routing from the bridge to the input pins and place the amplifier close to the sensor connector to minimize parasitic differential pickup.
推薦
Laboratory Data-Acquisition Systems
The AD625CDZ is appropriate for laboratory instrumentation that measures low-level differential signals across several programmable input ranges. Programmable gain allows a single analog front end to cover signals that would otherwise require separate amplifier selections, and the 25 MHz gain-bandwidth product supports gain configurations below the device's 650 kHz -3 dB bandwidth. The single +5 V supply simplifies laboratory supply design, while the 16-CDIP package supports through-hole prototyping, repair, and modular instrument construction.
推薦
Industrial Process-Control Front Ends
The AD625CDZ can condition small differential process signals in industrial measurement equipment where a 5 V analog supply is available. Its instrumentation-amplifier architecture is preferable to a general-purpose op amp when the source includes substantial common-mode voltage or requires matched internal gain resistors. The 650 kHz bandwidth accommodates many process-control signals without entering the high-frequency region where board layout becomes more difficult. Add input protection and isolation as required by the field wiring environment.
推薦
Medical and Diagnostic Instrumentation
The AD625CDZ can serve as the analog front end in low-level biomedical measurement systems where differential sensing, programmable gain, and low input bias current are important. Its 10 nA input bias current reduces disturbance of high-impedance transducers, while the 650 kHz bandwidth is suitable for many physiological and laboratory signals. The device's through-hole CDIP construction is also useful for legacy medical instruments and serviceable laboratory equipment. Confirm the applicable medical-grade qualification and isolation requirements for the final system.
推薦
Current-Loop and Low-Level Receiver Circuits
The AD625CDZ is suitable for current receivers that must preserve small differential information while rejecting voltage common to both input terminals. Its low 10 nA input bias current is beneficial when the source impedance is high, and the 25 MHz gain-bandwidth product gives design flexibility across moderate gain settings. Connect the receiver input pair with equal trace lengths and avoid routing them beneath digital or switching circuitry. The 5 V supply architecture keeps the analog rail straightforward in compact measurement modules.
推薦
Legacy Instrument Repair and Extension
The AD625CDZ is a practical choice for repairing or extending legacy laboratory and industrial instruments that use the AD625 family in a 16-CDIP through-hole footprint. Its listed 650 kHz bandwidth, 5 V/us slew rate, and 10 nA input bias current align with the original AD625 instrumentation-amplifier role. Because the manufacturer marks the AD625 as not recommended for new designs, this application is best treated as a maintenance or installed-base decision. Confirm pin functions, gain configuration, and the required temperature grade before substitution.
推薦
推薦產品摘要
工程參考資料,適用於 AD625CDZ — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | AD625BDZ | AD625SD | AD625BD | AD625 | AD625BZ |
|---|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | 16-CDIP | 16-CDIP | 16-CDIP | 16-CDIP | 16-CDIP | 16-CDIP |
| Amplifier Type | Programmable gain instrumentation amplifier | Instrumentation amplifier | Instrumentation amplifier | Instrumentation amplifier | Instrumentation amplifier | Instrumentation amplifier |
| Number of Circuits | 1 | 1 | 1 | 1 | 1 | 1 |
主要差異化特點
- Integrated programmable-gain instrumentation-amplifier function (對比AD625BDZ)
- Through-hole 16-CDIP construction for serviceable legacy equipment (對比AD625SD)
- High gain-bandwidth product for programmable measurement gain (對比AD625)
設計說明
Keep the differential input path short and symmetric. Route the two input conductors as a closely matched pair, terminate unused inputs according to the datasheet recommendations, and avoid placing the pair beside switching-node copper. The 10 nA input bias current is favorable for high-impedance sources, but board leakage and contamination can still be significant, so clean boards and guarded input structures are valuable in precision measurement systems.
The AD625CDZ uses a single +5 V supply. Place the required bypass capacitors immediately adjacent to the supply pins and keep the return path continuous and low impedance. Because the CDIP package has long through-hole leads, excessive bypass capacitance can create undesirable lead inductance; follow the manufacturer datasheet's recommended capacitance and placement rather than adding large capacitors at the device without accounting for stability.
Do not assume that every AD625 ordering suffix is interchangeable. AD625BDZ and AD625SD are documented as 16-CDIP alternatives with the same listed bandwidth and slew rate, but temperature grade, gain configuration, and qualification details must be checked against the exact ordering table. For new designs, note that Analog Devices marks the AD625 as not recommended for new designs and evaluate a currently recommended instrumentation amplifier instead.
The AD625CDZ's 650 kHz -3 dB bandwidth is the practical signal-bandwidth limit, while the 25 MHz gain-bandwidth product describes the internal gain-bandwidth relationship. Avoid treating the higher figure as usable closed-loop measurement bandwidth. Check settling time, slew rate, and gain-dependent bandwidth together when designing multiplexed acquisition paths or driving an ADC.
合規資訊
A distributor product listing identifies AD625CDZ as RoHS. The Analog Devices product page identifies the AD625 as not recommended for new designs. No additional REACH, halogen-free, or conflict-minerals statement was found for the exact ordering suffix.