The Texas Instruments INA110KU/1K is a monolithic fast-settling, FET-input instrumentation amplifier with one amplifier circuit in a 16-pin SOIC package. The device provides internally selectable gains of 1, 10, 100, 200, and 500 V/V and settles to 0.01% in 4 microseconds, making it suitable for high-speed and multiplexed data-acquisition systems where rapid input selection must be followed by accurate signal acquisition.

An instrumentation amplifier is a precision analog signal-conditioning IC that combines a differential input stage, input amplifiers, and an output difference amplifier into one package. This integrated approach provides higher common-mode rejection and gain accuracy than a discrete op-amp network. The INA110 belongs to the broader hierarchy of operational amplifiers, instrumentation amplifiers, analog signal-conditioning ICs, and semiconductor devices used to convert low-level sensor outputs into measurable voltages.

The INA110 uses a current-feedback circuit topology with a laser-trimmed input stage. Its FET inputs support high input impedance and low bias current, while the internal gain-set resistors reduce the number of external precision components required. Internal gain selections of 1, 10, 100, 200, and 500 V/V cover common sensor ranges spanning millivolts to several volts. The 4-microsecond settling specification is particularly important when several sensors are scanned through a multiplexer and each channel must be measured quickly.

The device is intended for bridge, strain-gauge, pressure-transducer, current-shunt, biomedical, and general-purpose differential-signal measurement. Its input-stage architecture is suited to systems where signal common-mode voltage varies and accurate rejection of common-mode disturbance is required. Designers must also account for the finite gain-bandwidth product, input and output voltage limits, supply range, input bias current, and the settling behavior of the selected gain when operating at high acquisition rates.

The INA110KU/1K is appropriate for precision data acquisition, industrial measurement, portable instrumentation, sensor-interface modules, and laboratory signal conditioning. In multiplexed systems, its fast settling can reduce the dead time between sensor channels. In low-frequency measurement systems, the same integrated gain network can simplify calibration while preserving repeatable gain settings. The manufacturer identifies the INA110 as a high-speed gain block suitable for both dedicated analog front ends and multiplexed acquisition systems.

For PCB implementation, use the manufacturer pin-description table when assigning tracks and keep the input and output routing short to reduce parasitic pickup of high-impedance sensor signals. Place the power-supply bypass capacitor close to the supply pins, maintain a quiet return path, and avoid routing sensitive input nodes beside switching-converter traces or digital clock lines. Check the selected gain against the datasheet bandwidth and settling requirements rather than relying on small-signal bandwidth alone.

This product page consolidates the INA110 device function, gain options, settling behavior, package information, drop-in replacement assessment, comparison parameters, and practical layout guidance into a design-focused reference. The comparison also distinguishes exact family options from devices whose electrical functions are similar but whose pin compatibility requires separate verification.

Bộ thay thế dễ dàng lắp đặt cho INA110KU/1K — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.

Các biến thể trong loạt này

Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với INA110KU/1K (cùng hình factor và footprint) — khác nhau ở Package, Product Type, RoHS Status, Architecture, Gain-Bandwidth Product.

Texas Instruments
Package: 16-pin SOIC (SOL-16)
Product Type: Monolithic FET-input instrumentation amplifier
Architecture: Current-feedback circuit topology
Texas Instruments
Product Type: Instrumentation Amplifier
RoHS Status: RoHS
Gain-Bandwidth Product: 2.5 MHz
Texas Instruments
Package: 16-pin SOIC
Product Type: Instrumentation amplifier
Gain-Bandwidth Product: 2 MHz
Texas Instruments
Package: 16-pin SOIC
Product Type: Low-cost, general-purpose precision instrumentation amplifier
Architecture: Three-op-amp design
Texas Instruments
Package: 8-SOIC (surface mount)
RoHS Status: Compliant
Architecture: Precision op amp + integrated thin-film resistor network

INA110KU

✅ Drop-In
Texas Instruments
📦 16-SOIC
Monolithic FET-input instrumentation amplifier · 1 circuit · 1, 10, 100, 200, and 500 V/V · 2.5 MHz · 4 us to 0.01% · 17 V/us · 1 mV · 12 V to 36 V

Liên hệ để biết giá

Xem tài liệu →

INA110KUG4

✅ Drop-In
Texas Instruments
📦 16-SOIC
Instrumentation Amplifier · 1 circuit · 2.5 MHz · 16-SOIC · Gull wing · 7.50 mm · Military · ±15 V

Liên hệ để biết giá

Xem tài liệu →

INA114BU

✅ Drop-In
Texas Instruments
📦 16-SOIC
Precision instrumentation amplifier · Three-op-amp design · 1 circuit · 1 MHz · 50 uV · 11 nV/√Hz · 3 mA · 1 to 10,000

Liên hệ để biết giá

Xem tài liệu →

INA111BU

✅ Drop-In
Texas Instruments
📦 16-SOIC
Instrumentation amplifier · 1 circuit · FET-input · 2 MHz · 17 V/us · 106 dB · Less than 20 pA · 6 V to 18 V

Liên hệ để biết giá

Xem tài liệu →

INA117KU

✅ Drop-In
Texas Instruments
📦 16-SOIC
Precision unity-gain difference amplifier · ±200 V (VS = ±15 V) · ±500 V · ±500 V · 1 V/V (unity) · 0.02% max · 0.001% max · 86 dB min

Liên hệ để biết giá

Xem tài liệu →

AD524ARZ-16

✅ Drop-In
📦 16-SOIC
Cross-brand 16-SOIC instrumentation amplifier; gain implementation and performance ratings differ from the INA110, so functional verification is required

📋 Tham chiếu thay thế (không có trong danh mục)

INA110KU/1K Tỷ lệ tối đa & tính chất điện

Amplifier Type Instrumentation amplifier
Number of Circuits 1 circuit
Input Type FET input
Cấu trúc Current-feedback circuit topology
Internal Gain Settings 1, 10, 100, 200, and 500 V/V
Settling Time to 0.01% 4 us
Hộp 16-SOIC
Terminal Count 16 terminals
Kiểu lắp đặt Surface mount
Trạng thái RoHS unknown
REACH Status unknown
AEC-Q100 Qualification unknown

Hướng dẫn cấu hình chân INA110KU/1K 16-soic

Cấu hình chân cho INA110KU/1K (16-soic gói). Thành phần số hiệu này có chân đầu vào, đầu ra và nguồn cung cấp. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết cấu hình chân bù, bù trừ và chân kích hoạt. Hoàn hảo cho điều kiện tín hiệu và mạch khuếch đại.

Bảng cấu hình chân 16-soic cho INA110KU/1K

Không có dữ liệu chân cụ thể sẵn có cho INA110KU/1K.

Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.

Ứng dụng tiêu biểu

INA110KU/1K phù hợp cho 6 Áp dụngs: Multiplexed Sensor Data Acquisition, Strain-Gauge Bridge Measurement, Pressure Transducer Interface, Portable Biomedical Instrumentation, Industrial Current-Shunt Monitoring, Laboratory Signal Conditioning.

🖥️

Multiplexed Sensor Data Acquisition

The INA110KU/1K fits multiplexed sensor acquisition because its 4-microsecond settling to 0.01% shortens the interval needed after each input is selected. The amplifier can process the resulting differential sensor voltage while internal gains of 1, 10, 100, 200, or 500 V/V adapt the signal range for an ADC. Designers should include mux settling, source impedance, amplifier settling, and the converter acquisition window when calculating the complete cycle time. Keeping sensor traces short and bypassing the supply at the device also reduces errors that could otherwise be mistaken for slow channel settling.

🏭

Strain-Gauge Bridge Measurement

The INA110KU/1K is appropriate for differential bridge measurements where excitation produces a small millivolt-level signal and the common-mode voltage is much larger. Its FET-input architecture supports high input impedance, while internal gain settings up to 500 V/V can amplify the bridge difference without a discrete precision gain network. Gain selection must account for the corresponding bandwidth and settling behavior. Place the amplifier close to the bridge, maintain symmetrical input routing, and use a quiet ground reference to limit offset and common-mode errors in the measured strain signal.

🏭

Pressure Transducer Interface

The INA110KU/1K can condition the differential output of a resistive pressure bridge while rejecting excitation-related common-mode voltage. The internal gain choices allow a designer to select 10, 100, 200, or 500 V/V according to the transducer's full-scale output and required ADC range. Its fast 4-microsecond settling to 0.01% is useful in systems that scan several pressure channels. For reliable measurements, verify input and output swing limits, avoid clipping, and reference the ADC range to the selected gain so the full bridge output remains within the linear region.

💊

Portable Biomedical Instrumentation

The INA110KU/1K is suitable for portable biomedical instrumentation when a low-level differential physiological signal must be amplified before digitization. FET inputs reduce loading on high-impedance sensors, and the internal gain network supports several signal ranges without a large external resistor array. The device's 4-microsecond settling also supports responsive acquisition of repeated or multiplexed channels. The circuit must still satisfy applicable medical-product safety and electromagnetic-compatibility requirements, and the sensor excitation, isolation strategy, leakage current, and electrode protection must be validated as a complete system.

⚡

Industrial Current-Shunt Monitoring

The INA110KU/1K can amplify the differential voltage generated across a current-shunt resistor when the shunt output lies within the amplifier's input range. Internal gain options let a single design cover signals from millivolts to substantially larger values, and fast settling supports rapid current measurements. Designers should choose the gain to keep the shunt voltage within the amplifier's linear input range while avoiding output saturation. A Kelvin connection from the shunt, short copper paths, and separation from high-current switching nodes are important for preserving measurement accuracy.

🔧

Laboratory Signal Conditioning

The INA110KU/1K is useful in laboratory instruments that must amplify a differential source while rejecting common-mode voltage and presenting a scaled signal to a converter or measurement instrument. The internal 1, 10, 100, 200, and 500 V/V gains provide repeatable range selection, while the fast settling response reduces dead time in automated test systems. For broadband laboratory signals, verify the gain-bandwidth product and output-drive limits for the selected gain. Use a shielded enclosure and guarded input routing when low-level signals would otherwise be affected by leakage, capacitance, or ambient interference.

What is the INA110KU/1K?
The INA110KU/1K is a Texas Instruments monolithic, fast-settling, FET-input instrumentation amplifier packaged in a 16-SOIC. It uses current-feedback circuitry and a laser-trimmed input stage, provides internal gains of 1, 10, 100, 200, and 500 V/V, and settles to 0.01% in 4 microseconds according to the TI product page.
What are the key specifications of INA110KU/1K that engineers should know?
The INA110KU/1K is a one-circuit, FET-input instrumentation amplifier with five internal gain settings: 1, 10, 100, 200, and 500 V/V. Its most important dynamic specification is 4-microsecond settling to 0.01%. The device uses a current-feedback topology and laser-trimmed input stage and is offered in a 16-SOIC package. According to the Texas Instruments INA110 product page, these characteristics target high-speed gain blocks and multiplexed-input data-acquisition systems.
Where can I download the INA110KU/1K datasheet PDF?
The official INA110KU/1K datasheet is available through the Texas Instruments INA110 product page at https://www.ti.com/product/INA110. The product page provides the manufacturer datasheet, ordering information, technical parameters, and support resources. Use the manufacturer document for the definitive pin-description table, absolute maximum ratings, recommended operating conditions, and electrical characteristics.
Where can I find the INA110KU/1K pinout?
The INA110KU/1K pinout is found in the pin-configuration and pin-description sections of the Texas Instruments INA110 datasheet. The component is a 16-SOIC with gull-wing leads. Because individual pin names are not printed in the accessible product listing, use the manufacturer datasheet when assigning each PCB land and keep the exposed connection assignments exactly as specified.
How fast does the INA110KU/1K settle?
The INA110KU/1K settles to within 0.01% of its final value in 4 microseconds. Texas Instruments identifies this fast-settling performance as suitable for high-speed gain blocks and multiplexed-input data-acquisition systems. In a multiplexed design, the settling time limits how quickly the converter may acquire the next sensor channel, so include amplifier settling, channel-switching time, and anti-alias filtering in the complete acquisition timing.
What gain settings are available in the INA110KU/1K?
The INA110KU/1K provides internal gain settings of 1, 10, 100, 200, and 500 V/V. These resistor-programmed gains allow the same device to handle low-level bridge outputs, strain-gauge signals, and larger differential inputs without requiring a complete external gain network. Confirm the gain-control logic and the usable bandwidth at each gain using the pin and electrical-characteristics tables in the Texas Instruments INA110 datasheet.
Is the INA110KU/1K suitable for multiplexed sensor inputs?
Yes, the INA110KU/1K is specifically suited to multiplexed-input data acquisition because it settles to 0.01% in 4 microseconds. This permits faster channel acquisition than an amplifier with a longer settling interval, provided the multiplexer, source impedance, protection network, and selected gain do not introduce additional accuracy limits. The manufacturer positions the INA110 as a high-speed gain block for multiplexed measurement systems.
What can replace the INA110KU/1K?
A valid drop-in replacement must match the 16-SOIC footprint, pin assignments, supply arrangement, gain-control interface, and critical electrical ratings. INA110 family devices with the same device and package option are the closest choices, while AD524ARZ-16, INA111BU, INA114BU, and INA117KU are related instrumentation-amplifier candidates requiring pinout verification. Confirm the manufacturer pin tables and gain logic before approving any substitution.
Is the INA110KU/1K the same as INA110KU?
The INA110KU/1K and INA110KU identify the same underlying INA110 device in 16-SOIC form, with the /1K ordering notation identifying the supplier packaging option. Cross-reference information distinguishes INA110KU from INA110KU/1K as separate orderable representations. Confirm reel orientation, tape orientation, and quantity in the manufacturer ordering table before treating them as identical purchasing codes.
When should I choose the INA110KU/1K over another instrumentation amplifier?
Choose the INA110KU/1K when the design needs a low-level differential measurement amplifier with internal gains from 1 to 500 V/V and 4-microsecond settling to 0.01%. It is especially useful when multiplexing sensors requires short acquisition intervals. Choose a precision, low-offset alternative only when its slower settling time remains acceptable and its input, gain-control, and pin arrangements can be matched.
What is the difference between INA110KU/1K and INA114BU?
The INA110KU/1K emphasizes fast settling to 0.01% in 4 microseconds and provides internal gains of 1, 10, 100, 200, and 500 V/V. The INA114BU is a precision instrumentation-amplifier family with a different construction and gain-selection approach. Both use 16-pin packages in relevant ordering configurations, but the pin functions and external component requirements must be checked before treating INA114BU as a drop-in replacement.
What is the difference between INA110KU/1K and INA117KU?
The INA110KU/1K is built around a current-feedback topology with laser-trimmed input circuitry, internal gains of 1 to 500 V/V, and 4-microsecond settling to 0.01%. The INA117KU is a related precision instrumentation amplifier that may offer different offset, noise, gain, and pin-control characteristics. Both appear in 16-pin SOIC configurations, but pin and gain-control verification is mandatory before replacement.
Where can I request a quote for INA110KU/1K?
Use the Request a Quote form on this page to request current pricing, stock, manufacturer lead time, and minimum order quantity for INA110KU/1K. The structured offer information is refreshed by the platform, while quote requests allow the exact 16-SOIC ordering code and required quantity to be confirmed before procurement.
Is INA110KU/1K in stock and what is its lead time?
Current stock and lead time should be confirmed through the Request a Quote form on this page using the exact INA110KU/1K ordering code. Distributor and manufacturer availability can vary by package quantity and date, so an inventory indication without a requested quantity is not a reliable production commitment. Specify the reel quantity, delivery location, and target schedule when requesting the quotation.
What is the price of INA110KU/1K?
The current INA110KU/1K quotation is obtained through the Request a Quote form on this page. The form can confirm the exact quantity tier, currency, availability, and packaging required for the 16-SOIC device. Request a quote using the full INA110KU/1K ordering code so that the response corresponds to the intended manufacturer part rather than a related INA110 ordering option.
Does the INA110KU/1K meet RoHS and REACH requirements?
RoHS and REACH status must be confirmed for the exact orderable INA110KU/1K through the Texas Instruments product and material-compliance documentation. The accessible manufacturer product page identifies the part as an INA110 device but does not provide a complete material-compliance declaration in its search summary. Use the current manufacturer compliance records for production qualification and procurement documentation.

Dữ liệu tham khảo kỹ thuật cho INA110KU/1K — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.

Hướng dẫn chọn lựa

Choose the INA110KU/1K when the design requires a 16-SOIC instrumentation amplifier with 1, 10, 100, 200, or 500 V/V internal gain and fast 4-microsecond settling to 0.01%. It is a strong fit for multiplexed sensor acquisition, bridge measurement, pressure-transducer interfaces, and current-shunt monitoring where acquisition speed and integrated gain selection matter. INA110KU and INA110KUG4 are the closest family options, but verify grade and tape-and-reel ordering details. Consider INA114BU when precision-oriented performance is more important than fast settling and its pin and gain interface match the design. INA111BU, INA117KU, and AD524ARZ-16 should be treated as engineering-review candidates rather than automatic substitutions: all appear in 16-SOIC-related cross-reference listings, but their gain programming, input characteristics, external components, and absolute ratings must be compared with the INA110 before release.

So sánh với các sản phẩm thay thế

Tham số Sản phẩm này INA110KU INA110KUG4 INA114BU INA111BU INA117KU AD524ARZ-16
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments Analog Devices
Package 16-SOIC 16-SOIC 16-SOIC 16-SOIC 16-SOIC 16-SOIC 16-SOIC
Function Instrumentation amplifier Instrumentation amplifier Instrumentation amplifier Instrumentation amplifier Instrumentation amplifier Instrumentation amplifier Instrumentation amplifier
Circuit Count 1 1 1 1 1 1 1

Bảo phân biệt quan trọng

  • Fast 0.01% settling supports high-speed acquisition (vsINA114BU)
  • Five integrated gain settings simplify range selection (vsAD524ARZ-16)
  • FET-input architecture supports high-impedance sensing (vsINA111BU)
  • Exact-family options simplify procurement continuity (vsINA117KU)

Ghi chú thiết kế

Route the two differential inputs as a closely matched pair and keep them short, because unequal capacitance can create settling differences when a multiplexer or switched sensor is connected. Connect the instrumentation amplifier close to the source to minimize parasitic capacitance and pickup. Keep the input nodes away from power-switching traces, relay contacts, display circuitry, and digital clock lines. Use the manufacturer pin-description table when identifying the gain-control and feedback connections.

Place the required bypass capacitor immediately beside the INA110KU/1K supply pins and connect it to a low-impedance ground plane. Follow the datasheet capacitor value and voltage-rating requirements exactly. Check supply current under the selected gain and output-load condition, and confirm that the source can start and remain within its operating range during input-channel switching. Adequate local bypassing helps prevent supply disturbance from appearing as input-referred measurement error.

Validate acquisition timing with amplifier settling included rather than relying only on nominal bandwidth. The INA110KU/1K settles to 0.01% in 4 microseconds, but multiplexer transitions, source impedance, filter capacitors, and ADC sampling add their own settling requirements. Use the complete timing budget to define the sample-and-hold interval, and verify the selected gain against the gain-bandwidth product before promising accurate high-rate measurements.

Do not assume that two 16-SOIC instrumentation amplifiers are interchangeable solely because their packages match. Compare pin functions, gain-control logic, common-mode range, output swing, supply requirements, and external compensation components before substituting INA114BU, INA111BU, INA117KU, or AD524ARZ-16. For the exact INA110KU and INA110KUG4 ordering variants, verify grade and reel-packing details rather than relying only on the abbreviated MPN.

Thông tin tuân thủ

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Không chì
Unknown
Không halogen
Unknown
Khoáng vật xung đột
Unknown

The accessible manufacturer product page identifies the INA110 family but does not state the exact material-compliance status of INA110KU/1K in the provided summary. Confirm current compliance records for the exact orderable part.

Tìm kiếm liên quan

INA110KU/1K datasheet INA110KU/1K specifications INA110KU/1K pinout INA110KU/1K datasheet pdf INA110KU/1K equivalent INA110KU/1K replacement INA110KU/1K price INA110KU/1K stock Texas Instruments INA110KU/1K INA110KU/1K instrumentation amplifier INA110KU/1K SOIC-16 pinout INA110KU/1K sensor interface INA110KU/1K vs INA114BU INA110KU/1K gain settings

Các bộ phận và thuật ngữ liên quan

Texas Instruments INA110KU/1K INA110 INA110KU INA110KUG4 INA114BU INA111BU INA117KU AD524ARZ-16 instrumentation amplifier signal-conditioning IC operational amplifier semiconductor FET input current-feedback topology laser-trimmed input stage gain-bandwidth product input bias current common-mode rejection settling time 16-SOIC SOIC package family surface-mount package multiplexed data acquisition strain-gauge bridge pressure transducer current-shunt monitor
Báo giá nhanh RFQ
Hãy điền đầy đủ thông tin — đội ngũ bán hàng của chúng tôi sẽ phản hồi trong vòng 24 giờ
Mã sản phẩm Nhà sản xuất Kiểu đóng gói QTY Giá mục tiêu Phụ
✓
Báo giá đã gửi!

Chúng tôi sẽ trả lời email của bạn trong vòng 24 giờ

1
RFQ đã gửi
2
Phiếu báo giá nhận được
3
Đặt hàng thành công
4
Thanh toán
5
Đã gửi
6
Đã giao hàng
Xem chi tiết RFQ