AT90CAN128-15MT - 128KB CAN AVR MCU | Microchip Technology
MPN: AT90CAN128-15MT ✓ 啟用中AT90CAN128-15MT 概覽
An 8-bit microcontroller is a programmable semiconductor that integrates a processor core, nonvolatile program memory, data memory, and peripheral interfaces onto one device. The AT90CAN128 belongs to the AVR family of low-power CMOS embedded controllers. Its enhanced RISC architecture, communication peripherals, and mixed-signal capability make it suitable for embedded control systems where CAN networking, deterministic control, and compact board area are important.
The AT90CAN128-15MT provides 128 KB of flash for application firmware, 4 KB of EEPROM for nonvolatile parameter storage, and 4 KB of SRAM for working data. Its 53 I/O lines support digital interfaces, while 32 working registers support efficient AVR instruction execution. The integrated CAN controller communicates using CAN 2.0A/V2.0B-compatible protocols, and the device also includes a real-time counter and flexible timer/counter resources.
Two USARTs provide serial communication paths, while the byte-oriented Two-Wire Interface supports a compact peripheral bus. The AT90CAN128 family also includes analog and timing resources suited to industrial monitoring, actuator control, and communication gateways. The 15 MHz grade trades some clock speed for potentially simpler timing, power-budget, and clock-tree implementation compared with the 16 MHz grade of the same family.
Typical uses include CAN-connected industrial controllers, vehicle subsystem controllers, building automation nodes, sensor aggregation equipment, and embedded CAN gateways. The 128 KB code space is useful for protocol stacks, diagnostic routines, local control logic, and application firmware. The combination of 53 I/O lines and CAN connectivity allows one device to bridge a local control network to a broader CAN bus.
PCB implementation should account for the exposed thermal pad beneath the 64-QFN package. Use the manufacturer land pattern, provide a continuous ground-plane connection to the exposed pad, and route high-current and sensitive signals away from the pad connection. Confirm external CAN transceiver, termination, clock, decoupling, and programming requirements against the manufacturer datasheet before release.
This product page combines the AT90CAN128-15MT specifications, package details, practical application guidance, and same-footprint replacement considerations into an engineering-focused reference. It also highlights where clock-grade differences matter when evaluating an alternative.
直接替換替代品,適用於 AT90CAN128-15MT — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: AT90CAN128-15MT (相同外形與佔位) — 差異在於 Package, CAN Controller, Flash Memory, Supply Voltage Range, ADC Channels.
AT90CAN128-15MU
✅ 直接替換 ⚠️ 規格未經驗證📋 參考替代品(不在目錄中)
AT90CAN128-15MT1
✅ 直接替換📋 參考替代品(不在目錄中)
AT90CAN128-16MU
✅ 直接替換聯絡詢價
查看資料表 →AT90CAN128-16AU
✅ 直接替換 ⚠️ 規格未經驗證聯絡詢價
查看資料表 →AT90CAN128-16MU
✅ 直接替換聯絡詢價
查看資料表 →AT90CAN128-15MT 最大額定值與電氣特性
| Product Type | 8-bit AVR RISC microcontroller |
| 最大時脈頻率 | 15 MHz |
| Flash Memory | 128 KB |
| EEPROM | 4 KB |
| SRAM | 4 KB |
| General-Purpose I/O Lines | 53 |
| General-Purpose Working Registers | 32 |
| CAN Controller | CAN 2.0A/V2.0B compatible |
| USART Count | 2 |
| Two-Wire Interface | Byte-oriented |
| Real-Time Counter | 1 |
| Supply Voltage Range | 2.7 V to 5.5 V |
| 封裝 | 64-QFN (9 x 9 mm), exposed pad |
| 安裝類型 | Surface mount |
| Core Architecture | AVR enhanced RISC |
| Qualification | AEC-Q100 |
| RoHS 狀態 | Compliant |
| Timer/Counters | 4 flexible timer/counters |
AT90CAN128-15MT 64-qfn (9 x 9 mm), exposed pad 腳位配置指南
AT90CAN128-15MT(64-qfn (9 x 9 mm), exposed pad 封裝)的腳位配置。 此數位 IC 包含 GPIO、通訊介面(UART、SPI、I2C)與電源腳位。替代腳位功能與配置選項請參閱製造商資料表。對嵌入式系統設計與 PCB 佈局至關重要。
無詳細腳位定義資料: AT90CAN128-15MT.
請參閱 資料表 以查看完整腳位配置。
典型應用
AT90CAN128-15MT 適用於 6 應用s: CAN-Connected Industrial Controller, Vehicle Subsystem Controller, Building Automation Gateway, Sensor Aggregation Equipment, CAN Network Diagnostic Tool, Actuator and Motor-Control Node.
CAN-Connected Industrial Controller
The AT90CAN128-15MT fits industrial equipment that must exchange diagnostic or command data over a CAN bus while executing local control logic. Its 128 KB flash can hold communication handlers, diagnostics, state machines, and application firmware, while 4 KB of SRAM supports runtime buffering and 4 KB of EEPROM preserves configuration values. The 15 MHz AVR core and four timer/counters support periodic sampling and actuator timing. A separate CAN transceiver, correct 120-ohm bus termination, and carefully routed differential traces remain required for a production CAN interface.
推薦
Vehicle Subsystem Controller
The AT90CAN128-15MT is appropriate for a distributed vehicle module that receives commands over CAN and controls sensors, relays, or actuators locally. Its 53 general-purpose I/O lines provide substantial digital connectivity, and the integrated CAN 2.0A/V2.0B-compatible controller supports networked vehicle functions. Four flexible timer/counters are useful for periodic control tasks. Because automotive designs require exact qualification and temperature-range control, engineers must verify the selected order code against the Microchip automotive data sheet and system-level EMC, load-dump, and transient requirements before production use.
推薦
Building Automation Gateway
The AT90CAN128-15MT can serve as a building-automation gateway that collects sensor information and distributes control commands across a CAN-based network. Its two USARTs provide paths for local serial devices, while the byte-oriented Two-Wire Interface supports compatible peripheral sensors or actuators. The 128 KB program space is useful for protocol handling, diagnostics, logging, and application logic. Designers should isolate CAN and serial routing from sensitive inputs, provide local decoupling according to the manufacturer guidance, and verify that the 15 MHz timing budget remains adequate for the gateway protocol and update workload.
推薦
Sensor Aggregation Equipment
The AT90CAN128-15MT is well suited to industrial sensing equipment that combines multiple inputs, performs local calculations, and publishes measurements through CAN. Its 53 I/O lines can support discrete sensors and digital signaling, while 4 KB of EEPROM can retain calibration or configuration records. Four timer/counters provide periodic sampling and timing functions, and the 15 MHz grade supports deterministic control without requiring the 16 MHz clock grade. Input conditioning, analog measurement circuitry, sensor isolation, and grounding should be designed separately because the MCU provides the digital control and communication foundation rather than complete sensor front ends.
推薦
CAN Network Diagnostic Tool
The AT90CAN128-15MT can implement a compact CAN diagnostic device for bench testing, service access, or network monitoring. Its 128 KB flash can accommodate protocol firmware, fault logging, identification tables, and communication diagnostics, while the integrated CAN controller handles bus frame processing. The two USARTs can support a host computer or configuration terminal, and the 53 I/O lines allow status indicators, control inputs, and test outputs. Use an isolated transceiver arrangement where the device connects to an external vehicle or machine bus, and verify termination, common-mode protection, and EMC behavior in the final enclosure.
推薦
Actuator and Motor-Control Node
The AT90CAN128-15MT can act as a distributed actuator node that receives commands over CAN and operates local outputs using its timer and counter resources. Its 53 I/O lines allow connection to control inputs, status signals, and driver-enable circuitry, while four flexible timer/counters support pulse generation and timing functions. The 4 KB SRAM is adequate for compact command and state management, and EEPROM can preserve node identity or calibration parameters. Power-stage design, protection, thermal management, and electromagnetic compatibility remain the responsibility of the surrounding circuitry rather than the MCU itself.
推薦
推薦產品摘要
工程參考資料,適用於 AT90CAN128-15MT — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | AT90CAN128-15MU | AT90CAN128-15MT1 | AT90CAN128-16MU | AT90CAN128-16AU |
|---|---|---|---|---|---|
| Brand | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology |
| Package | 64-QFN (9 x 9 mm), exposed pad | 64-QFN (9 x 9 mm), exposed pad | 64-QFN (9 x 9 mm), exposed pad | 64-QFN (9 x 9 mm), exposed pad | 64-QFN (9 x 9 mm), exposed pad |
| Maximum Clock Frequency | 15 MHz | 15 MHz | 15 MHz | 16 MHz | 16 MHz |
| Flash Memory | 128 KB | 128 KB | 128 KB | 128 KB | 128 KB |
| EEPROM | 4 KB | 4 KB | 4 KB | 4 KB | 4 KB |
| SRAM | 4 KB | 4 KB | 4 KB | 4 KB | 4 KB |
| General-Purpose I/O Lines | 53 | 53 | 53 | 53 | 53 |
| CAN Controller | CAN 2.0A/V2.0B compatible | CAN 2.0A/V2.0B compatible | CAN 2.0A/V2.0B compatible | CAN 2.0A/V2.0B compatible | CAN 2.0A/V2.0B compatible |
| Supply Voltage Range | 2.7 V to 5.5 V | 2.7 V to 5.5 V | 2.7 V to 5.5 V | 2.7 V to 5.5 V | 2.7 V to 5.5 V |
| USART Count | 2 | 2 | 2 | 2 | 2 |
主要差異化特點
- Matches the established 15 MHz AT90CAN128 timing grade (對比AT90CAN128-16MU)
- Combines 128 KB flash with CAN connectivity in one MCU (對比AT90CAN128-16MU)
- Provides substantial local digital I/O for distributed nodes (對比AT90CAN128-16AU)
- SAME-speed family option is available for second-source review (對比AT90CAN128-15MU)
設計說明
Treat the 64-QFN exposed pad as a mandatory thermal and electrical connection. Follow the Microchip recommended land pattern and place a low-inductance via array within the pad footprint, then connect that region to the ground plane. Avoid splitting the ground plane beneath the package, and keep high-current return paths outside the pad area. The pad provides vertical heat conduction into the PCB, but it cannot replace copper area, via stitching, or airflow needed at elevated ambient temperature.
Implement the PCB from the complete manufacturer pin-description table rather than from the family-level block diagram. Verify power, ground, reset, clock, programming, and CAN-controller assignments directly against the 64-QFN drawing. Keep the exposed-pad via field unobstructed, place decoupling capacitance close to the corresponding supply pins, and preserve the recommended return-current path. A complete pin audit before routing is especially important because exposed-pad packages combine perimeter pins with a large central thermal connection.
Route CAN TX and RX from the MCU to the transceiver as short, referenced traces with continuous return paths, and connect the transceiver to the physical bus through a layout that meets its isolation and termination requirements. Place the bus termination only at the appropriate ends of the network. Keep switching regulators, high-current drivers, clock sources, and long parallel digital routes away from the differential CAN path to reduce radiated noise and susceptibility to common-mode interference.
Do not treat a 16 MHz family member as an automatic substitute for a design validated at 15 MHz. The 6.7% clock increase can change baud-rate error, timer periods, interrupt latency, and communication timing. Preserve the original oscillator and fuse configuration when possible, recalculate all timing-dependent behavior, and run CAN stress tests before releasing the higher-clock alternative. Likewise, verify the exact temperature grade and ordering-code meaning for each MT, MU, and AU suffix.
合規資訊
The Microchip AT90CAN32/64/128 automotive data sheet states that product quality and reliability were verified through regular product qualification under AEC-Q100. RoHS status is compliant; other environmental declarations are not established by the cited documentation.