AT90CAN128-ESAZ - 128KB AVR CAN Microcontroller | Microchip
MPN: AT90CAN128-ESAZ ✓ 啟用中AT90CAN128-ESAZ 概覽
An 8-bit microcontroller is a programmable semiconductor that executes firmware from embedded flash memory while using I/O pins to interface with sensors, actuators, communication transceivers, and human-machine interfaces. The AT90CAN128 belongs to the AVR enhanced RISC family and combines single-cycle instruction execution with integrated CAN networking. Its architecture is intended to provide efficient deterministic control for industrial, transportation, communications, and embedded automation systems.
Principal features include 128 KB of in-system-programmable flash with read-while-write operation, 4 KB of EEPROM for nonvolatile configuration data, and 4 KB of SRAM for working memory. The device provides 53 general-purpose I/O lines and 32 general-purpose working registers. Two USARTs, one Two-wire Serial Interface, four timer/counters, PWM channels, and a CAN controller reduce the need for external peripheral devices in connected embedded systems.
The enhanced AVR RISC architecture executes powerful instructions within a single clock cycle, allowing the AT90CAN128 family to approach 1 MIPS of throughput per megahertz under appropriate operating conditions. In-System Programming supports programming and configuration through the device interface. The CAN block supports both CAN 2.0A and CAN 2.0B frame formats, while the real-time counter provides a dedicated timing resource independent of the main timer/counter workload.
Typical applications include industrial CAN gateways, vehicle and transportation modules, building-automation controllers, remote monitoring equipment, CAN-connected sensors, motor-control systems, and industrial data-acquisition equipment. The integrated communication peripherals allow a compact design to connect a microcontroller node to a CAN physical-layer transceiver while retaining substantial local processing capability.
Designers should match the external CAN transceiver to the bus voltage and termination requirements, isolate transceiver supply as appropriate, and account for the package's exposed thermal-pad layout during PCB assembly. Firmware development should also validate clock startup, interrupt priorities, watchdog behavior, and CAN error handling before deployment in a safety-relevant or high-availability network.
This page combines the AT90CAN128-ESAZ memory, communication, interface, and package characteristics with drop-in alternatives, application guidance, and practical hardware-design considerations. It supports faster engineering evaluation by separating the MCU's onboard resources from the external transceiver, clock, memory, and power-supply requirements of a complete CAN node.
直接替換替代品,適用於 AT90CAN128-ESAZ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: AT90CAN128-ESAZ (相同外形與佔位) — 差異在於 CAN Controller, Package, Real-Time Counter.
AT90CAN128-16AZ
✅ 直接替換📋 參考替代品(不在目錄中)
AT90CAN128-16AU
✅ 直接替換聯絡詢價
查看資料表 →AT90CAN128-16MU
✅ 直接替換聯絡詢價
查看資料表 →AT90CAN128-ESAZ 最大額定值與電氣特性
| Product Type | 8-bit AVR RISC microcontroller |
| Flash Memory | 128 KB ISP flash |
| EEPROM | 4 KB |
| SRAM | 4 KB |
| General-Purpose I/O Lines | 53 lines |
| General-Purpose Working Registers | 32 registers |
| CAN Controller | CAN 2.0A and CAN 2.0B compliant |
| USART Count | 2 serial ports |
| Two-wire Serial Interface | 1 byte-oriented TWI interface |
| Timer/Counters | 4 timer/counters with compare modes and PWM |
| Real-Time Counter | 1 real-time counter |
| 封裝 | 64-QFN |
| 安裝類型 | Surface mount |
| In-System Programming | Supported |
| Read-While-Write | Supported for ISP flash |
AT90CAN128-ESAZ 64-qfn 腳位配置指南
AT90CAN128-ESAZ(64-qfn 封裝)的腳位配置。 此數位 IC 包含 GPIO、通訊介面(UART、SPI、I2C)與電源腳位。替代腳位功能與配置選項請參閱製造商資料表。對嵌入式系統設計與 PCB 佈局至關重要。
無詳細腳位定義資料: AT90CAN128-ESAZ.
請參閱 資料表 以查看完整腳位配置。
典型應用
AT90CAN128-ESAZ 適用於 6 應用s: Industrial CAN Gateway, Vehicle CAN Control Module, Building Automation Controller, Remote Environmental Monitoring, Motor Control and PWM Module, Industrial Data Acquisition Unit.
Industrial CAN Gateway
The AT90CAN128-ESAZ fits an industrial CAN gateway because it combines a compliant CAN 2.0A/2.0B controller with 128 KB of ISP flash and 53 I/O lines. The MCU can process local telemetry, enforce protocol conversion, and manage digital inputs while communicating through an external CAN transceiver. Its 4 KB SRAM supports message buffering and gateway state, while 4 KB EEPROM retains configuration such as node addresses and filter parameters. Designers should isolate the transceiver from logic where required and implement watchdog, bus-off recovery, and fault-state behavior in firmware.
推薦
Vehicle CAN Control Module
The AT90CAN128-ESAZ is suited to vehicle electronics requiring embedded logic, CAN communication, and multiple peripheral interfaces. Its CAN controller can exchange diagnostic and control frames, while two USARTs and the TWI interface support sensors, actuators, and service equipment. The 128 KB flash provides room for protocol stacks and application logic, and four timer/counters support timing or PWM tasks. Automotive deployment requires confirmation of the exact temperature range, qualification status, transceiver selection, transient protection, and failure-mode requirements for the vehicle platform.
推薦
Building Automation Controller
The AT90CAN128-ESAZ can serve as a building-automation controller that coordinates sensors, actuators, and network gateways over CAN. Its 53 I/O lines provide direct digital interfaces, while the real-time counter and flexible timers support periodic measurement and control functions. Two USARTs can connect display or service modules, and TWI can accommodate sensors requiring a short two-wire bus. The 128 KB flash is sufficient for structured application code, while EEPROM preserves calibration values and device settings. Power-supply design should account for long idle periods, supervised startup, and the load presented by attached CAN transceivers.
推薦
Remote Environmental Monitoring
The AT90CAN128-ESAZ is useful in remote environmental-monitoring nodes that combine local sensing with shared CAN connectivity. The integrated controller supports efficient polling, event reporting, and diagnostic frames, while the 53 I/O lines can operate digital sensors, status indicators, and local alarms. Four timer/counters allow periodic sampling and PWM generation, and the real-time counter supports timekeeping functions. The 4 KB EEPROM can retain calibration coefficients and counters across resets. For battery-powered installations, use the MCU's low-power operating modes selectively, account for transceiver sleep current, and validate the regulator's efficiency across the complete battery-voltage range.
推薦
Motor Control and PWM Module
The AT90CAN128-ESAZ can coordinate a CAN-connected motor-control module because it combines four timer/counters with compare modes, PWM support, and a real-time counter. The MCU can generate control signals, process position or current feedback, and report operating states over CAN. Its 128 KB flash allows room for motion-control logic and diagnostics, while 53 I/O lines simplify interfacing with gates, sensors, and protection circuits. The MCU does not replace a dedicated gate driver or power stage, so those external components must be selected for the motor voltage, current, isolation, and switching requirements.
推薦
Industrial Data Acquisition Unit
The AT90CAN128-ESAZ fits a data-acquisition unit that gathers digital measurements and forwards processed results over a CAN network. Its 53 I/O lines support sensors, switches, counters, and front-panel signals, while two USARTs accept external instruments or service connections. The 4 KB SRAM can hold acquisition buffers, and 128 KB flash supports drivers, calibration, and communications software. The two USARTs and TWI allow serial devices to be managed concurrently, while timers support uniform sampling intervals. Firmware should include watchdog recovery, input debouncing, sensor diagnostics, and data-integrity checks before acquisition results are used for control decisions.
推薦
推薦產品摘要
工程參考資料,適用於 AT90CAN128-ESAZ — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | AT90CAN128-16AZ | AT90CAN128-16AU | AT90CAN128-16MU |
|---|---|---|---|---|
| Brand | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology |
| Package | 64-QFN | 64-QFN | 64-QFN | 64-QFN |
| Architecture | 8-bit AVR enhanced RISC | 8-bit AVR enhanced RISC | 8-bit AVR enhanced RISC | 8-bit AVR enhanced RISC |
| ISP Flash Memory | 128 KB | 128 KB | 128 KB | 128 KB |
| EEPROM | 4 KB | 4 KB | 4 KB | 4 KB |
| SRAM | 4 KB | 4 KB | 4 KB | 4 KB |
| General-Purpose I/O | 53 lines | 53 lines | 53 lines | 53 lines |
| CAN Controller | CAN 2.0A/2.0B compliant | CAN 2.0A/2.0B compliant | CAN 2.0A/2.0B compliant | CAN 2.0A/2.0B compliant |
| Serial Interfaces | 2 USART and 1 byte-oriented TWI | 2 USART and 1 byte-oriented TWI | 2 USART and 1 byte-oriented TWI | 2 USART and 1 byte-oriented TWI |
| Timer/Counters | 4 with compare modes and PWM | 4 with compare modes and PWM | 4 with compare modes and PWM | 4 with compare modes and PWM |
| Real-Time Counter | 1 | 1 | 1 | 1 |
| Exact Ordering Attributes | ESAZ suffix | 16AZ suffix | 16AU suffix | 16MU suffix |
主要差異化特點
- Integrated network and general-purpose control resources (對比AT90CAN128-16MU)
- Substantial embedded program and configuration memory (對比AT90CAN128-16AZ)
- Multiple serial interfaces reduce external peripheral count (對比AT90CAN128-16AU)
設計說明
Route the AT90CAN128-ESAZ power, decoupling, ground, and exposed-pad lands exactly as specified in the Microchip package drawing and board-layout guidance. Place high-frequency decoupling capacitors close to the associated supply pins, connect the exposed thermal pad to the intended copper plane, and maintain uninterrupted return paths beneath the device. Use the package pin-description table to assign the 64-QFN pads and verify the pin-one orientation before fabrication.
The MCU CAN controller requires an external physical-layer transceiver; CAN TXD and RXD are not direct differential-bus pins. Keep the digital connection between the AT90CAN128-ESAZ and transceiver short, route it away from switching nodes and high-current paths, and provide the bus with the termination and protection required by the network. Verify signal levels and timing against both the MCU datasheet and the selected transceiver documentation.
Budget the regulator for the MCU, external transceiver, pull resistors, and attached peripherals rather than the AT90CAN128-ESAZ alone. Check the minimum operating voltage at the highest bus traffic rate and worst-case transceiver load, and account for voltage drop across supply traces. Use local decoupling to isolate CAN-transceiver switching current from the MCU supply and confirm that power-up and brownout behavior satisfy the node's restart requirements.
Do not assume that all AT90CAN128 order codes are interchangeable. The family shares a core and major peripheral set, but the suffix can change clock rating, temperature grade, package configuration, or qualification. Before substitution, compare the complete ordering table, clock characteristics, electrical limits, package drawing, and pin descriptions. Firmware should also include CAN bus-off recovery and watchdog behavior so a communication or firmware fault does not leave the node indefinitely unavailable.
合規資訊
Compliance declarations for the exact AT90CAN128-ESAZ ordering code were not identified in the manufacturer or distributor material. Confirm current environmental and qualification documentation with Microchip Technology before production release.