INA116UAG4 - 3 fA Input Bias Instrumentation Amplifier | Texas Instruments
MPN: INA116UAG4 ✗ 停產INA116UAG4 概覽
An instrumentation amplifier is a precision analog signal-conditioning IC that amplifies the voltage difference between two inputs while rejecting common-mode signals. It belongs to the amplifier hierarchy as an instrumentation amplifier, a differential amplifier, and ultimately an analog integrated circuit. The INA116 uses a three-op-amp topology and differential inputs protected by special guarding techniques, making it suitable for high-impedance sensors where even picoamp-level input current could create unacceptable measurement error.
The primary features of the INA116UAG4 include extremely low input bias current, gains from 1 to 1000 established with one external resistor, and a bandwidth of 800 kHz. Its 0.8 V/µs slew rate supports accurate reproduction of moderate-frequency signals. The guarded input structure reduces leakage through PCB contamination and helps preserve accuracy in high-impedance measurement circuits.
Technically, the monolithic FET-input architecture separates the input stage from the gain-setting network and allows operation with extremely low input currents. Differential inputs reduce sensitivity to common-mode voltage, while the internal three-op-amp topology provides accurate gain control without requiring matched external resistors. This combination is especially useful when source impedance is high and the sensor output is much smaller than environmental offsets or interference.
Typical uses include precision current measurement, pH and electrochemical sensor interfaces, photodiode signal chains, biomedical instrumentation, and low-current sensor amplification. The 800 kHz bandwidth is suitable for sensor systems requiring signal amplification without the complexity of a high-speed voltage-feedback amplifier. The 16-pin SOIC package allows conventional surface-mount assembly and PCB routing.
The primary design consideration is guarding and board cleanliness. Keep input traces short, isolate them from high-impedance leakage paths, remove contamination, and place the gain resistor close to the gain-setting pins. Confirm the actual input bias current, common-mode range, supply limits, output swing, and operating temperature limits against the manufacturer datasheet before finalizing a production design.
This page combines manufacturer specifications, ordering information, drop-in family options, application guidance, and design cautions for engineers evaluating the INA116UAG4 as a low-bias precision analog front end.
直接替換替代品,適用於 INA116UAG4 — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: INA116UAG4 (相同外形與佔位) — 差異在於 Amplifier Type, Gain Range, Package, Bandwidth, Input Offset Voltage.
INA116UAG4 最大額定值與電氣特性
| Product Type | Ultra-low-input-bias-current instrumentation amplifier |
| Input Bias Current at 25°C | 3 fA typical |
| Input Bias Current at 85°C | 25 fA typical |
| Gain Range | 1 to 1000 |
| Gain Setting Method | 1 external resistor |
| Internal Topology | 3-op-amp instrumentation amplifier |
| Input Stage | Monolithic FET input |
| Bandwidth | 800 kHz -3 dB |
| Slew Rate | 0.8 V/µs |
| Number of Circuits | 1 circuit |
| Differential Input | Yes |
| Input Guarding | Special input guarding techniques |
| 封裝 | 16-pin SOIC |
| Package Code | UA |
| 安裝類型 | Surface mount |
| Temperature Grade | Industrial |
| Amplifier Type | Standard general-purpose instrumentation amplifier |
INA116UAG4 ua 腳位配置指南
INA116UAG4(ua 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: INA116UAG4.
請參閱 資料表 以查看完整腳位配置。
典型應用
INA116UAG4 適用於 6 應用s: Electrochemical Sensor Interface, Photodiode Signal Acquisition, Precision Current Measurement, Medical and Biomedical Instrumentation, Industrial Sensor Conditioning, Precision Bridge Measurement.
Electrochemical Sensor Interface
The INA116UAG4 fits electrochemical and pH-style sensors because its input bias current is only 3 fA at 25°C and 25 fA at 85°C. A high-impedance sensor can present source resistance in the gigohm range, where amplifier input current produces meaningful voltage error even when the sensor voltage is only millivolts. The differential three-op-amp architecture also helps reject common-mode voltage present on both sensor electrodes. Place the device close to the sensor connector, keep input traces short, and apply guarding according to the manufacturer datasheet. Its resistor-programmed gain from 1 to 1000 allows weak sensor outputs to be amplified close to the source, improving signal integrity before downstream filtering and digitization.
推薦
Photodiode Signal Acquisition
The INA116UAG4 is appropriate for photodiode and optical-detector front ends where source leakage and amplifier bias current establish the noise floor. Its 3 fA typical input bias current at 25°C minimizes the voltage generated across very high photodiode or transimpedance-network resistance. The 800 kHz -3 dB bandwidth and 0.8 V/µs slew rate provide useful response beyond slow photodiode systems while preserving the low-input-current architecture. Keep the photodiode input route compact and away from switching circuitry, and evaluate the gain resistor and compensation network in the application circuit rather than increasing gain indiscriminately.
推薦
Precision Current Measurement
The INA116UAG4 can amplify the output of a low-current transducer where the measurement target approaches the picoamp range. Its 3 fA typical input bias current at 25°C prevents the amplifier from loading the sensing element, while differential input helps reject supply and ground disturbances common to both sides of the sensor. The programmable gain range of 1 to 1000 allows the signal chain to use the full ADC range without excessive post-amplification noise. For a complete measurement system, account for transducer sensitivity, burden resistance, offset, and bandwidth when choosing the external gain resistor and subsequent filter.
推薦
Medical and Biomedical Instrumentation
The INA116UAG4 supports low-level biomedical instrumentation because its extremely low input bias current reduces loading on skin-electrode, bioimpedance, and ion-sensor interfaces. The 3 fA typical input current at 25°C is especially relevant when electrode impedance is high and patient signals are small. Differential input helps reject common-mode interference, and the gain range of 1 to 1000 provides flexibility for signal levels ranging from millivolts to sub-volt instrumentation signals. Medical designs still require separate consideration of patient protection, isolation, leakage current, electromagnetic immunity, and application-specific qualification; those safety functions are not established by the amplifier specifications alone.
推薦
Industrial Sensor Conditioning
The INA116UAG4 can condition outputs from high-impedance industrial sensors when leakage current is a meaningful error source. Its 3 fA typical input bias current at 25°C reduces interaction with long sensor cables and high-impedance transducers, while the differential topology supports common-mode rejection in industrial environments. The 800 kHz bandwidth is suitable for many process and condition-monitoring signals, and the 0.8 V/µs slew rate avoids excessive delay on moderate transients. PCB cleanliness, guard routing, isolation from high-voltage switching nodes, and suitable surge protection remain critical because environmental contamination and coupling paths can dominate errors below the amplifier's intrinsic input-current level.
推薦
Precision Bridge Measurement
The INA116UAG4 is useful in bridge-based pressure, strain, and resistance measurements when the bridge output is small and the complete circuit is referenced near ground. The three-op-amp differential architecture is intended to amplify a small voltage between bridge nodes while rejecting common-mode excitation and ground differences. Its 3 fA typical input bias current at 25°C minimizes errors in high-impedance branches, and the gain range of 1 to 1000 supports excitation levels that vary across sensors. Use the manufacturer application guidance to select the gain resistor and output filter, and verify bridge excitation, input common-mode range, and output swing against the final sensor and mechanical tolerances.
推薦
推薦產品摘要
工程參考資料,適用於 INA116UAG4 — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | INA116UA | INA116U |
|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 16-pin SOIC (UA) | 16-pin SOIC (UA) | 16-pin SOIC (UA) |
| Input Bias Current at 25°C | 3 fA typical | 3 fA typical | 3 fA typical |
| Input Bias Current at 85°C | 25 fA typical | 25 fA typical | 25 fA typical |
| Gain Range | 1 to 1000 | 1 to 1000 | 1 to 1000 |
| Gain-Setting Method | 1 external resistor | 1 external resistor | 1 external resistor |
| Bandwidth | 800 kHz -3 dB | 800 kHz -3 dB | 800 kHz -3 dB |
| Slew Rate | 0.8 V/µs | 0.8 V/µs | 0.8 V/µs |
| Internal Topology | 3-op-amp instrumentation amplifier | 3-op-amp instrumentation amplifier | 3-op-amp instrumentation amplifier |
| Input Stage | Monolithic FET input | Monolithic FET input | Monolithic FET input |
| Number of Circuits | 1 circuit | 1 circuit | 1 circuit |
主要差異化特點
- Extremely low input bias current supports high-impedance sensing (對比INA117)
- Single-resistor gain programming covers a wide measurement range (對比INA114)
- Input guarding supports leakage-sensitive PCB layouts (對比General-purpose precision operational amplifiers)
設計說明
Treat the INA116UAG4 inputs as leakage-sensitive nodes. Keep the input traces short, avoid parallel copper runs beneath the inputs, and remove flux and ionic contamination after assembly. The amplifier's 3 fA typical input bias current at 25°C is exceptionally small, so PCB leakage can become comparable to the device input current. Follow the guard-pin guidance in the manufacturer datasheet and avoid placing the input loop beside switching nodes or power inductors.
Place the external gain-setting resistor close to the gain terminals to minimize susceptibility to leakage and parasitic capacitance. Maintain a symmetrical, compact differential-input route where practical, and connect the sensor or bridge directly to the input pins rather than extending sensitive traces through a connector. Grounding and guarding should be designed together so leakage currents are directed away from the input node instead of through the source impedance.
Do not select the INA116 solely by its 800 kHz bandwidth. Verify the complete operating envelope in the manufacturer datasheet, including supply voltage, common-mode input range, output swing, gain accuracy, and temperature limits. Also avoid assuming that every INA-family amplifier is pin-compatible: INA117 and INA114 comparison results identify related functions but do not establish the same 16-pin footprint or lead mapping as the INA116UAG4.
Match the bandwidth and slew rate to the sensor bandwidth rather than using the maximum gain indiscriminately. The INA116UAG4 provides 1-to-1000 gain with an 800 kHz -3 dB bandwidth and 0.8 V/µs slew rate. At high closed-loop gain, bandwidth becomes more restrictive, while excessive gain can amplify offset, noise, and leakage. Establish the usable frequency range from the complete gain equation and filter design before allocating ADC resolution.
合規資訊
The product is identified as an industrial-grade instrumentation amplifier. Specific RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations were not established by the retrieved content.