INA116UAG4 - 3 fA Input Bias Instrumentation Amplifier | Texas Instruments
料号: INA116UAG4 ✗ 停产INA116UAG4 概述
An instrumentation amplifier is a precision analog signal-conditioning IC that amplifies the voltage difference between two inputs while rejecting common-mode signals. It belongs to the amplifier hierarchy as an instrumentation amplifier, a differential amplifier, and ultimately an analog integrated circuit. The INA116 uses a three-op-amp topology and differential inputs protected by special guarding techniques, making it suitable for high-impedance sensors where even picoamp-level input current could create unacceptable measurement error.
The primary features of the INA116UAG4 include extremely low input bias current, gains from 1 to 1000 established with one external resistor, and a bandwidth of 800 kHz. Its 0.8 V/µs slew rate supports accurate reproduction of moderate-frequency signals. The guarded input structure reduces leakage through PCB contamination and helps preserve accuracy in high-impedance measurement circuits.
Technically, the monolithic FET-input architecture separates the input stage from the gain-setting network and allows operation with extremely low input currents. Differential inputs reduce sensitivity to common-mode voltage, while the internal three-op-amp topology provides accurate gain control without requiring matched external resistors. This combination is especially useful when source impedance is high and the sensor output is much smaller than environmental offsets or interference.
Typical uses include precision current measurement, pH and electrochemical sensor interfaces, photodiode signal chains, biomedical instrumentation, and low-current sensor amplification. The 800 kHz bandwidth is suitable for sensor systems requiring signal amplification without the complexity of a high-speed voltage-feedback amplifier. The 16-pin SOIC package allows conventional surface-mount assembly and PCB routing.
The primary design consideration is guarding and board cleanliness. Keep input traces short, isolate them from high-impedance leakage paths, remove contamination, and place the gain resistor close to the gain-setting pins. Confirm the actual input bias current, common-mode range, supply limits, output swing, and operating temperature limits against the manufacturer datasheet before finalizing a production design.
This page combines manufacturer specifications, ordering information, drop-in family options, application guidance, and design cautions for engineers evaluating the INA116UAG4 as a low-bias precision analog front end.
直接替换替代料: INA116UAG4 ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: INA116UAG4 (相同外形与封装尺寸) ——差异在于 Amplifier Type, Gain Range, Package, Bandwidth, Input Offset Voltage.
INA116UAG4 最大额定值与电气特性
| Product Type | Ultra-low-input-bias-current instrumentation amplifier |
| Input Bias Current at 25°C | 3 fA typical |
| Input Bias Current at 85°C | 25 fA typical |
| Gain Range | 1 to 1000 |
| Gain Setting Method | 1 external resistor |
| Internal Topology | 3-op-amp instrumentation amplifier |
| Input Stage | Monolithic FET input |
| Bandwidth | 800 kHz -3 dB |
| Slew Rate | 0.8 V/µs |
| Number of Circuits | 1 circuit |
| Differential Input | Yes |
| Input Guarding | Special input guarding techniques |
| 封装 | 16-pin SOIC |
| Package Code | UA |
| 安装类型 | Surface mount |
| Temperature Grade | Industrial |
| Amplifier Type | Standard general-purpose instrumentation amplifier |
INA116UAG4 ua 引脚配置指南
INA116UAG4(ua 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: INA116UAG4.
请参阅 数据手册 以查看完整引脚配置。
典型应用
INA116UAG4 适用于 6 应用s: Electrochemical Sensor Interface, Photodiode Signal Acquisition, Precision Current Measurement, Medical and Biomedical Instrumentation, Industrial Sensor Conditioning, Precision Bridge Measurement.
Electrochemical Sensor Interface
The INA116UAG4 fits electrochemical and pH-style sensors because its input bias current is only 3 fA at 25°C and 25 fA at 85°C. A high-impedance sensor can present source resistance in the gigohm range, where amplifier input current produces meaningful voltage error even when the sensor voltage is only millivolts. The differential three-op-amp architecture also helps reject common-mode voltage present on both sensor electrodes. Place the device close to the sensor connector, keep input traces short, and apply guarding according to the manufacturer datasheet. Its resistor-programmed gain from 1 to 1000 allows weak sensor outputs to be amplified close to the source, improving signal integrity before downstream filtering and digitization.
推荐
Photodiode Signal Acquisition
The INA116UAG4 is appropriate for photodiode and optical-detector front ends where source leakage and amplifier bias current establish the noise floor. Its 3 fA typical input bias current at 25°C minimizes the voltage generated across very high photodiode or transimpedance-network resistance. The 800 kHz -3 dB bandwidth and 0.8 V/µs slew rate provide useful response beyond slow photodiode systems while preserving the low-input-current architecture. Keep the photodiode input route compact and away from switching circuitry, and evaluate the gain resistor and compensation network in the application circuit rather than increasing gain indiscriminately.
推荐
Precision Current Measurement
The INA116UAG4 can amplify the output of a low-current transducer where the measurement target approaches the picoamp range. Its 3 fA typical input bias current at 25°C prevents the amplifier from loading the sensing element, while differential input helps reject supply and ground disturbances common to both sides of the sensor. The programmable gain range of 1 to 1000 allows the signal chain to use the full ADC range without excessive post-amplification noise. For a complete measurement system, account for transducer sensitivity, burden resistance, offset, and bandwidth when choosing the external gain resistor and subsequent filter.
推荐
Medical and Biomedical Instrumentation
The INA116UAG4 supports low-level biomedical instrumentation because its extremely low input bias current reduces loading on skin-electrode, bioimpedance, and ion-sensor interfaces. The 3 fA typical input current at 25°C is especially relevant when electrode impedance is high and patient signals are small. Differential input helps reject common-mode interference, and the gain range of 1 to 1000 provides flexibility for signal levels ranging from millivolts to sub-volt instrumentation signals. Medical designs still require separate consideration of patient protection, isolation, leakage current, electromagnetic immunity, and application-specific qualification; those safety functions are not established by the amplifier specifications alone.
推荐
Industrial Sensor Conditioning
The INA116UAG4 can condition outputs from high-impedance industrial sensors when leakage current is a meaningful error source. Its 3 fA typical input bias current at 25°C reduces interaction with long sensor cables and high-impedance transducers, while the differential topology supports common-mode rejection in industrial environments. The 800 kHz bandwidth is suitable for many process and condition-monitoring signals, and the 0.8 V/µs slew rate avoids excessive delay on moderate transients. PCB cleanliness, guard routing, isolation from high-voltage switching nodes, and suitable surge protection remain critical because environmental contamination and coupling paths can dominate errors below the amplifier's intrinsic input-current level.
推荐
Precision Bridge Measurement
The INA116UAG4 is useful in bridge-based pressure, strain, and resistance measurements when the bridge output is small and the complete circuit is referenced near ground. The three-op-amp differential architecture is intended to amplify a small voltage between bridge nodes while rejecting common-mode excitation and ground differences. Its 3 fA typical input bias current at 25°C minimizes errors in high-impedance branches, and the gain range of 1 to 1000 supports excitation levels that vary across sensors. Use the manufacturer application guidance to select the gain resistor and output filter, and verify bridge excitation, input common-mode range, and output swing against the final sensor and mechanical tolerances.
推荐
推荐产品汇总
工程参考数据: INA116UAG4 ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | INA116UA | INA116U |
|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 16-pin SOIC (UA) | 16-pin SOIC (UA) | 16-pin SOIC (UA) |
| Input Bias Current at 25°C | 3 fA typical | 3 fA typical | 3 fA typical |
| Input Bias Current at 85°C | 25 fA typical | 25 fA typical | 25 fA typical |
| Gain Range | 1 to 1000 | 1 to 1000 | 1 to 1000 |
| Gain-Setting Method | 1 external resistor | 1 external resistor | 1 external resistor |
| Bandwidth | 800 kHz -3 dB | 800 kHz -3 dB | 800 kHz -3 dB |
| Slew Rate | 0.8 V/µs | 0.8 V/µs | 0.8 V/µs |
| Internal Topology | 3-op-amp instrumentation amplifier | 3-op-amp instrumentation amplifier | 3-op-amp instrumentation amplifier |
| Input Stage | Monolithic FET input | Monolithic FET input | Monolithic FET input |
| Number of Circuits | 1 circuit | 1 circuit | 1 circuit |
关键差异点
- Extremely low input bias current supports high-impedance sensing (对比 INA117)
- Single-resistor gain programming covers a wide measurement range (对比 INA114)
- Input guarding supports leakage-sensitive PCB layouts (对比 General-purpose precision operational amplifiers)
设计说明
Treat the INA116UAG4 inputs as leakage-sensitive nodes. Keep the input traces short, avoid parallel copper runs beneath the inputs, and remove flux and ionic contamination after assembly. The amplifier's 3 fA typical input bias current at 25°C is exceptionally small, so PCB leakage can become comparable to the device input current. Follow the guard-pin guidance in the manufacturer datasheet and avoid placing the input loop beside switching nodes or power inductors.
Place the external gain-setting resistor close to the gain terminals to minimize susceptibility to leakage and parasitic capacitance. Maintain a symmetrical, compact differential-input route where practical, and connect the sensor or bridge directly to the input pins rather than extending sensitive traces through a connector. Grounding and guarding should be designed together so leakage currents are directed away from the input node instead of through the source impedance.
Do not select the INA116 solely by its 800 kHz bandwidth. Verify the complete operating envelope in the manufacturer datasheet, including supply voltage, common-mode input range, output swing, gain accuracy, and temperature limits. Also avoid assuming that every INA-family amplifier is pin-compatible: INA117 and INA114 comparison results identify related functions but do not establish the same 16-pin footprint or lead mapping as the INA116UAG4.
Match the bandwidth and slew rate to the sensor bandwidth rather than using the maximum gain indiscriminately. The INA116UAG4 provides 1-to-1000 gain with an 800 kHz -3 dB bandwidth and 0.8 V/µs slew rate. At high closed-loop gain, bandwidth becomes more restrictive, while excessive gain can amplify offset, noise, and leakage. Establish the usable frequency range from the complete gain equation and filter design before allocating ADC resolution.
合规信息
The product is identified as an industrial-grade instrumentation amplifier. Specific RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations were not established by the retrieved content.