MAX232EWE+T - 120kbps 5V RS-232 Transceiver | Maxim
MPN: MAX232EWE+T ✓ 啟用中MAX232EWE+T 概覽
An RS-232 transceiver is an interface IC that converts low-voltage CMOS or TTL logic signals into RS-232 levels and converts incoming RS-232 signals back into logic-compatible levels. It belongs to the interface IC hierarchy and is commonly placed between a host controller, microcontroller, or data-processing equipment and an external RS-232 port. Unlike a direct TTL connection, the MAX232EWE+T adds voltage-level translation, noise tolerance, and standard-compliant line signaling.
The device supports a 4.5 V to 5.5 V supply range and data rates up to 120 kbps. Its two drivers and two receivers are intended for EIA/TIA-232E, V.28, and V.24 interfaces. The integrated charge-pump circuitry eliminates the need for an external positive supply, while external capacitors provide the voltage multiplication and supply filtering required by the device.
The MAX232 family uses bipolar charge-pump circuitry to translate a 5 V input into approximately positive and negative RS-232 output levels. Receiver inputs are designed to detect the corresponding negative-going RS-232 signals, while the drivers provide the required level shifting and signal conditioning. Because the interface operates through voltage conversion rather than differential signaling, it is intended for point-to-point RS-232 connections rather than long multidrop networks.
Typical uses include serial service ports, industrial control links, configuration interfaces, test equipment, and legacy peripheral connections. Two transmit and two receive channels can support one hardware handshake flow or two independent unidirectional links. The 120 kbps capability also makes the device suitable for moderate-rate data links where legacy RS-232 equipment must interoperate with newer control electronics.
PCB design should place the charge-pump capacitors close to their associated pins and keep the RS-232 connector interface path away from sensitive analog or high-speed digital traces. Protection components may be added at exposed connector pins, but their capacitance and clamping voltage must be checked so they do not impair receiver detection or driver operation.
This product page combines the manufacturer interface specifications with practical PCB guidance, application-oriented design context, and a package-focused comparison. It helps engineers distinguish the wide-SOIC MAX232EWE+T from temperature-grade, packing-code, narrow-SOIC, and functionally similar interface devices that may not be drop-in replacements for an existing layout.
直接替換替代品,適用於 MAX232EWE+T — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: MAX232EWE+T (相同外形與佔位) — 差異在於 Product Type, Interface Standard, Package.
MAX232CWE+T
✅ 直接替換聯絡詢價
查看資料表 →MAX232EWE-T
✅ 直接替換📋 參考替代品(不在目錄中)
MAX232CWE+
✅ 直接替換聯絡詢價
查看資料表 →MAX232EWE+T 規格
| Product Type | RS-232 transceiver interface IC |
| Transmit Channels | 2 drivers |
| Receive Channels | 2 receivers |
| Supply Voltage Range | 4.5 V to 5.5 V |
| Maximum Data Rate | 120 kbps |
| Interface Standard | EIA/TIA-232E |
| Additional Standards | CCITT V.28 and V.24 |
| Logic Supply | +5 V |
| 封裝 | 16-pin wide SOIC |
| Package Width | 7.50 mm |
| Package Length | 0.295 inch |
| 腳位數 | 16 pins |
| 安裝類型 | Surface mount |
MAX232EWE+T 0.295 inch 腳位配置指南
MAX232EWE+T(0.295 inch 封裝)的腳位配置。 腳位編號、功能與連接圖定義於製造商資料手冊中。請參閱該手冊以取得確切的封裝尺寸與焊接指引。
無詳細腳位定義資料: MAX232EWE+T.
請參閱 資料表 以查看完整腳位配置。
典型應用
MAX232EWE+T 適用於 6 應用s: Industrial Controller Serial Port, Legacy Peripheral Configuration, Test and Measurement Equipment, Serial Service and Diagnostics, Embedded Data Acquisition Module, Networking and Router Management Port.
Industrial Controller Serial Port
The MAX232EWE+T is appropriate for an industrial controller that must communicate with legacy RS-232 equipment over a point-to-point cable. Its two driver channels and two receive channels support a full-duplex data path plus hardware handshaking, while operation up to 120 kbps covers typical service-port traffic. The 4.5 V to 5.5 V supply range also matches conventional 5 V logic systems. Place the charge-pump capacitors near the IC and route connector-side traces away from sensitive digital circuitry to reduce coupling. The 16-pin wide-SOIC package provides a practical surface-mount implementation for control boards where connector protection and grounding are handled separately.
推薦
Legacy Peripheral Configuration
The MAX232EWE+T can connect a modern controller to a legacy peripheral that retains an RS-232 configuration port. The receiver translates incoming negative-going RS-232 levels into logic signals, while the driver converts the controller's logic output into the required line voltage. Two drivers allow separate control and status paths when the peripheral uses RTS and CTS handshaking. The 120 kbps maximum data rate is more than adequate for configuration and diagnostic traffic. Designers should verify logic levels, provide connector-side protection, and observe the manufacturer's recommended capacitor layout to maintain signal timing and charge-pump behavior.
推薦
Test and Measurement Equipment
The MAX232EWE+T is useful in test equipment that needs to exchange commands and results with a RS-232-controlled instrument. The two receive channels can collect separate status signals, and the two transmit channels can support command output plus flow control. With operation up to 120 kbps, the interface handles short command frames and moderate diagnostic data streams without requiring a higher-speed transceiver. A careful layout should keep the RS-232 traces away from analog inputs and reference circuitry. Grounding and cable transients remain system-level concerns, so connector protection should be selected with suitable capacitance and standoff characteristics.
推薦
Serial Service and Diagnostics
The MAX232EWE+T supports service consoles, maintenance ports, and diagnostic interfaces that rely on RS-232 rather than USB or Ethernet. The single +5 V supply simplifies implementation in equipment where negative RS-232 voltage generation is otherwise inconvenient. Two drivers and two receivers permit full-duplex messaging and optional hardware handshaking, while the 120 kbps limit suits command-oriented service protocols. Use short, properly referenced connections and place the external charge-pump capacitors directly beside the associated pins. The surface-mount wide-SOIC package also supports automated assembly in production equipment without requiring through-hole interconnects.
推薦
Embedded Data Acquisition Module
The MAX232EWE+T can provide a robust wired interface between an embedded data-acquisition controller and an external instrument. Its two receive channels support separate data and status lines, and its two driver channels can carry commands and acknowledgments. The 120 kbps rate is suitable for many sensor, laboratory, and process-control links that transfer compact records rather than continuous high-bandwidth streams. Because RS-232 is point-to-point and uses voltage levels referenced to ground, the module should implement suitable cable grounding and connector protection. Decouple the 5 V rail locally and preserve the recommended charge-pump capacitor placement to avoid timing distortion.
推薦
Networking and Router Management Port
The MAX232EWE+T is applicable to management ports on routers, switches, and network appliances that expose an RS-232 console for configuration or diagnostics. The device supplies the required electrical translation between internal 5 V logic and the RS-232 console connector while supporting two receive paths for console data and hardware flow control. Its 120 kbps capability comfortably covers terminal interaction rates. Board-level implementation should reserve space for connector protection, maintain separation between the port and sensitive Ethernet or power sections, and verify the exact MAX232EWE+T suffix against environmental requirements. This arrangement preserves a conventional administrative interface without requiring a negative external supply.
推薦
推薦產品摘要
工程參考資料,適用於 MAX232EWE+T — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | MAX232CWE+T | MAX232EWE-T | MAX232CWE |
|---|---|---|---|---|
| Package | 16-pin wide SOIC | 16-pin wide SOIC | 16-pin wide SOIC | 16-pin wide SOIC |
| Brand | Maxim Integrated | Maxim Integrated | Maxim Integrated | Maxim Integrated |
| Product Type | RS-232 transceiver | RS-232 transceiver | RS-232 transceiver | RS-232 transceiver |
主要差異化特點
- Two-driver, two-receiver interface in one package (對比MAX232CWE+T)
- 120 kbps maximum signaling rate (對比MAX232EWE-T)
- Single 5 V supply with integrated level translation (對比MAX232CWE)
設計說明
Place the MAX232EWE+T charge-pump capacitors and 5 V bypass capacitor close to their associated package pins. Keep the charge-pump capacitor loop compact to reduce radiated noise and maintain clean internal supply generation. Route connector-side RS-232 traces away from clocks, ADC inputs, and precision analog nodes; when separation is impossible, use a grounded guard structure and verify the completed layout with signal-integrity measurements.
Do not assume that a shared SOIC designation guarantees interchangeability. Verify the package width, pin functions, temperature grade, supply limits, and external capacitor requirements for every suffix. In particular, a wide-SOIC MAX232EWE+T must not be placed on a footprint intended for a narrow-SOIC device. Confirm the manufacturer ordering table before approving a substitute in a new or revised PCB layout.
RS-232 is a point-to-point, single-ended interface, so cable routing, grounding, and connector protection influence reliability more than trace geometry at 120 kbps. Select protection devices with capacitance compatible with the receiver and driver timing requirements. Avoid long unterminated stub branches, maintain a consistent ground reference, and test the completed cable assembly for startup glitches and ground-loop-induced noise.
合規資訊
Compliance declarations were not present in the accessible product information. The +T ordering suffix identifies the tape-and-reel delivery configuration and does not by itself establish environmental qualification.