MPVZ5010GW6U - 0-10kPa Pressure Sensor, 5V, SOP-8 | NXP
MPN: MPVZ5010GW6U ✓ 啟用中MPVZ5010GW6U 概覽
Piezoresistive pressure sensors are transducers that convert an applied mechanical pressure into a proportional electrical signal through the piezoresistive effect in doped silicon. The MPVZ5010GW6U belongs to the MPXx5010 family of integrated silicon pressure sensors, sitting within the broader hierarchy of pressure sensor -> MEMS sensor -> transducer -> sensor IC. By integrating the strain-gauge bridge, temperature compensation, and calibration into a single silicon die, this product class eliminates the discrete op-amp and reference circuits required by raw bridge sensors, simplifying host-side firmware.
Key features include a 5 V typical supply, full-scale output of 4.7 V at 10 kPa, accuracy of ±1.5% over 0°C to 85°C, and a vented-gauge reference that compensates for ambient barometric pressure drift. The 8-SMD gull-wing package with a 5.59 mm tube-style port supports pneumatic manifold mounting, while the ratiometric output scales proportionally with supply voltage for ADC-friendly conversion. The calibration and on-chip signal conditioning minimize board space and external part count.
The transducer uses bipolar processing combined with thin-film metallization and advanced micromachining techniques, producing a high-level analog output. The built-in temperature compensation and calibration deliver stable readings across the operating temperature range, making the part suitable for applications where host-side compensation is impractical or where field calibration is difficult.
Typical applications include medical respiratory monitoring, HVAC air-flow sensing, industrial vacuum monitoring, barometric reference, and appliance pressure feedback. Its low-voltage 0.2 V near-zero offset (referenced to vacuum) makes it straightforward to detect blocked filter conditions or vacuum-leak events in pump-driven systems.
When designing with this device, plan the pneumatic interface carefully: the axial port accepts 5.59 mm tubing, and the vented-gauge reference must remain unobstructed for accurate readings. Decouple VDD with a 0.1 µF ceramic capacitor placed within 5 mm of the supply pin, and condition the analog output with a simple RC low-pass filter if the application reads the ADC faster than 1 kHz.
This page synthesizes distributor stock and pricing (DigiKey, Mouser, Octopart), NXP/MPX5010 family cross references, and practical design notes not consolidated in the manufacturer datasheet.
直接替換替代品,適用於 MPVZ5010GW6U — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: MPVZ5010GW6U (相同外形與佔位) — 差異在於 Package, Accuracy, Operating Temperature, Operating Pressure Range, Output Voltage Range.
MPVZ5010G6U
✅ 直接替換聯絡詢價
查看資料表 →MPVZ5010GW7U
✅ 直接替換聯絡詢價
查看資料表 →MPXV5010G
✅ 直接替換📋 參考替代品(不在目錄中)
MPXV5010GC6U
✅ 直接替換聯絡詢價
查看資料表 →MPVZ5010GW6U 最大額定值與電氣特性
| Pressure Type | Vented Gauge |
| Operating Pressure Range | 0 kPa to 10 kPa (0 to 1.45 PSI) |
| 供應電壓 | 5 V typical |
| 輸出電壓範圍 | 0.2 V to 4.7 V |
| 輸出類型 | Analog, ratiometric |
| Accuracy | ±1.5% over 0°C to 85°C |
| Port Style | Top axial, 0.22" (5.59 mm) tube |
| 工作溫度 | 0°C to +85°C |
| 封裝 | 8-SMD, Gull Wing, SOP-8 |
| 安裝類型 | Surface Mount |
| RoHS 狀態 | Compliant |
| Technology | Piezoresistive MEMS |
| Signal Conditioning | On-chip, calibrated and temperature compensated |
| Pressure Reference Side | Vented gauge (atmosphere) |
MPVZ5010GW6U 腳位配置
| 腳位 1 | VCC — 5V supply input |
| 腳位 2 | GND — Ground |
| 腳位 3 | VOUT — Analog ratiometric output (0.2V to 4.7V) |
| 腳位 4 | NC — Not connected |
| 腳位 5 | NC — Not connected |
| 腳位 6 | NC — Not connected |
| 腳位 7 | NC — Not connected |
| 腳位 8 | NC — Not connected |
典型應用
MPVZ5010GW6U 適用於 6 應用s: Medical Respiratory Monitoring, HVAC Air-Flow and Filter Monitoring, Industrial Vacuum and Pump Monitoring, Barometric Reference and Weather Stations, Appliance Pressure Feedback (Vacuum Cleaners, Dishwashers), Portable Gas-Analysis Sample Lines.
Medical Respiratory Monitoring
The MPVZ5010GW6U is well suited for respiratory monitoring and ventilator pressure feedback due to its 0 to 10 kPa calibrated range and integrated temperature compensation. With 0.2 V at zero and 4.7 V at 10 kPa on a 5 V ratiometric output, it maps directly into an MCU ADC with no external amplification, supporting pediatric to adult airway pressure. The vented-gauge reference automatically compensates for ambient barometric variation, which is critical in portable and home-care devices. Its ±1.5% accuracy over 0°C to 85°C meets typical respiratory equipment drift budgets. Compared with raw bridge sensors, the integrated calibration reduces firmware overhead and BOM cost, while the SOP-8 SMD form factor suits compact handheld enclosures.
推薦
HVAC Air-Flow and Filter Monitoring
The MPVZ5010GW6U measures pressure drop across HVAC filters and air-handling ducts in the 0 to 10 kPa band, enabling blockage detection and fan-speed control loops. The 5 V ratiometric output drives a 10-bit ADC at full transfer-function resolution, while the integrated calibration eliminates per-unit offset adjustment during manufacture. The vented-gauge reference ignores barometric drift between indoor and outdoor installation sites, a key advantage over sealed-gauge parts. The 5.59 mm axial port accepts standard pneumatic tubing, simplifying field retrofit. Its 0°C to 85°C range covers commercial rooftop and indoor unit environments, and the SOP-8 SMD package is friendly to automated pick-and-place assembly.
推薦
Industrial Vacuum and Pump Monitoring
Industrial vacuum systems rely on the MPVZ5010GW6U's ability to read sub-atmospheric pressures down to 0 kPa with high linearity, providing direct feedback for vacuum-pump leak-down tests and process control. The 0.2 V near-zero offset allows the MCU to flag a fully blocked vacuum port as a stuck sensor or system fault, while the 4.7 V full-scale output represents the rated 10 kPa working point. The integrated calibration removes manual trim during production, and the rugged SOP-8 SMD package survives industrial vibration and temperature swing. Compared with MPX5010DP higher-range parts, the MPVZ5010GW6U's 0 to 10 kPa span offers finer 10-bit ADC resolution per kPa, useful for low-pressure process control.
推薦
Barometric Reference and Weather Stations
The MPVZ5010GW6U serves as a vented-gauge barometric reference when paired with an absolute-pressure sensor in weather stations, providing the atmospheric baseline needed to compute altitude-corrected readings. The ratiometric 0.2 V to 4.7 V output over 0 to 10 kPa spans typical barometric variation (~100 kPa +/- the local differential) when used in a stack-up configuration. The factory calibration and temperature compensation prevent long-term drift across outdoor 0°C to 85°C swings, and the small SOP-8 SMD footprint fits compact weatherproof enclosures. According to NXP application briefs, vented-gauge integration simplifies host software versus manual atmospheric compensation.
推薦
Appliance Pressure Feedback (Vacuum Cleaners, Dishwashers)
The MPVZ5010GW6U enables suction-level and water-pressure feedback in consumer appliances, replacing costly discrete pressure switches with a continuous analog signal. The 0.2 V to 4.7 V output feeds directly into an appliance MCU ADC, supporting variable-speed motor control, filter-life indication, and leak detection without external amplification. The SOP-8 SMD package withstands typical reflow profiles, lowering production cost versus legacy through-hole pressure switches. The 0°C to 85°C range covers indoor appliance environments, and the integrated temperature compensation prevents calibration drift across seasonal temperature changes. Compared with mechanical pressure switches, the MPVZ5010GW6U enables closed-loop control algorithms that improve energy efficiency.
推薦
Portable Gas-Analysis Sample Lines
The MPVZ5010GW6U monitors sample-line pressure in portable gas analyzers and breathalyzers, where the 0 to 10 kPa range matches draw-pressure setpoints of internal micro-pumps. The ratiometric analog output integrates directly with low-power MCU ADCs, drawing no measurable current from the host side; the 5 V supply decouples with a simple 0.1 µF capacitor. The vented-gauge reference compensates for environmental altitude variation, critical for handheld instruments operating outdoors. Its on-chip calibration and temperature compensation eliminate host-side lookup tables, reducing firmware complexity. According to NXP MPVZ5010 datasheet notes, the low-voltage 0.2 V near-zero reference simplifies fault detection of clogged inlet filters.
推薦
推薦產品摘要
工程參考資料,適用於 MPVZ5010GW6U — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | MPVZ5010G6U | MPVZ5010GW7U | MPXV5010G | MPXV5010GC6U | MPX5010GP |
|---|---|---|---|---|---|---|
| Package | 8-SMD, Gull Wing (SOP-8) | 8-SMD, Gull Wing (SOP-8) | 7-pin through-hole (DIP) | 8-SMD, Gull Wing (SOP-8) | 8-SMD, Gull Wing (SOP-8) | 6-SIP port-side integrated |
| Brand | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors |
| Pressure Range | 0 to 10 kPa | 0 to 10 kPa | 0 to 10 kPa | 0 to 10 kPa | 0 to 10 kPa | 0 to 100 kPa |
| Supply Voltage | 5 V | 5 V | 5 V | 5 V | 5 V | 5 V |
| Output Voltage Range | 0.2 V to 4.7 V | 0.2 V to 4.7 V | 0.2 V to 4.7 V | 0.2 V to 4.7 V | 0.2 V to 4.7 V | 0.2 V to 4.7 V |
| Output Type | Analog ratiometric | Analog ratiometric | Analog ratiometric | Analog ratiometric | Analog ratiometric | Analog ratiometric |
| Port Style | Top axial 5.59 mm | Single axial (variant) | Top axial (DIP variant) | Side mount | Case 98ASA18417D | Port-side integrated SIP |
| Operating Temperature | 0°C to 85°C | 0°C to 85°C | 0°C to 85°C | 0°C to 85°C | 0°C to 85°C | 0°C to 85°C |
主要差異化特點
- Integrated calibration and temperature compensation in SOP-8 SMD (對比MPVZ5010GW7U)
- Vented-gauge reference for atmospheric compensation (對比MPX5010GS)
- 0 to 10 kPa optimized for low-pressure medical and HVAC use (對比MPX5010GP)
設計說明
Decouple the MPVZ5010GW6U supply pin (Pin 1) with a 0.1 µF X7R ceramic capacitor placed within 5 mm of the device, with a 10 µF bulk capacitor for higher-load transients. Keep analog output traces away from switching DC-DC converter noise; route the VOUT trace over a continuous ground plane and add a small RC low-pass filter (e.g., 100 Ω + 0.01 µF) if the host ADC samples faster than 1 kHz to attenuate above-bandwidth noise.
The vented-gauge reference requires the rear vent (case-side reference hole) to remain unobstructed - avoid sealing the package underside with epoxy or solder mask. Place the device on a layout that exposes the vent to ambient air, and route signal traces on the opposite side from the port to minimize mechanical stress on the package.
Do not apply pressure exceeding the 10 kPa rated range, as the on-chip strain gauge can permanently offset. Avoid exposing the port to liquids or condensation; the SOP-8 SMD package is not water-sealed, so for medical/wet environments pair the device with a manifold barrier or hydrophobic membrane. According to NXP notes, ESD precautions (grounding straps and conductive foam) should be observed during pick-and-place to prevent damage to the MEMS die.
Estimated: at 5V supply with 5 mA typical quiescent draw, internal dissipation is ~25 mW. Thermal rise is negligible under normal conditions, but in enclosed high-temperature appliances (e.g., dishwasher or boiler) keep ambient below 85°C by mounting the device on a copper pour or thermal relief pattern. Solder joint reliability improves with a 1.27 mm pitch SOP-8 land pattern per IPC-7351.
合規資訊
RoHS compliant per NXP product page; not AEC-Q100 qualified as this is a medical/industrial-grade sensor rather than automotive-grade.