Reported by PV Magazine on . Summarized and analyzed by XAIPART Editorial.
What happened
Vaillant launched the aroTherm perform monobloc air-to-water heat pump for large residential buildings, renovation projects and small commercial properties.S1 The series is available in 15 kW and 20 kW classes.S1 According to Vaillant, the larger model can supply space heating and domestic hot water for new buildings up to 1,200 m², renovated buildings up to 750 m² and non-renovated properties up to 500 m².S1
The system uses propane refrigerant R290 and can reportedly produce 75 C supply water at an outdoor temperature of -10 C without auxiliary heat.S1 At -15 C ambient temperature, it can deliver supply temperatures up to 70 C.S1 Vaillant documentation lists the VWL 205/8.1 A S2 Q at 11.2 kW heating capacity and 5.66 COP at A7/W35; at A-7/W35, output reaches 19.6 kW with a 2.6 COP.S1
The series carries an A+++ classification at 55 C supply temperature.S1 Reported SCOP values reach 5.44 for the 15 kW model and 5.35 for the 20 kW model at 35 C under average climate conditions.S1 The outdoor unit measures approximately 1,230 mm × 1,890 mm × 788 mm, weighs around 310 kg and requires a 400 V three-phase electrical supply.S1 The 20 kW version has a reported sound power level of 50 dB(A) under ErP rating conditions and a maximum of approximately 63 dB(A); night mode can reduce emissions by up to 10 dB(A).S1
Flexible Space Function is intended to ease outdoor-unit placement near windows and doors while retaining applicable propane safety requirements.S1 The aroTherm perform also includes the iQconnect platform, a 7-inch touchscreen, commissioning assistance, remote monitoring, over-the-air updates, myVaillant app control, energy-management integration and rooftop photovoltaic integration.S1 Up to six heat pumps can reportedly operate in a cascade configuration.S1
| Metric | Reported value | Source |
|---|---|---|
| Capacity classes | 15 kW and 20 kW | S1 |
| A7/W35 heating capacity | 11.2 kW | S1 |
| A7/W35 COP | 5.66 | S1 |
| A-7/W35 heating output | 19.6 kW | S1 |
| A-7/W35 COP | 2.6 | S1 |
| Maximum cascade size | 6 heat pumps | S1 |
| Electrical supply | 400 V three-phase | S1 |
| Maximum sound power | Approximately 63 dB(A) | S1 |
Background timeline
XAIPART take
Technical impact
For engineering teams, the low-temperature performance points are more useful than the nominal class label: the documented 19.6 kW result at A-7/W35 provides a practical starting point for winter heat-load calculations. Projects should request full operating maps rather than infer output from the 20 kW designation, especially where the design temperature differs from -7 C. XAIPART analysis
Market impact
R290 equipment adds propane-handling and placement constraints to procurement scope, while the three-phase supply requirement may affect electrical design and site upgrades. Buyers should treat local installer capability, safety-zone compliance and appliance availability as separate qualification items. Vaillant did not disclose pricing, channel availability or lead times, so buyers cannot use this report to compare supply risk or landed cost. XAIPART analysis
Action
Request the aroTherm perform technical documentation, noise data and cascade controls package before specifying the VWL 205/8.1 A S2 Q. Confirm design heat loads, domestic-hot-water demand, electrical capacity and applicable propane installation rules with the mechanical contractor and authority having jurisdiction. Check whether project schedules require early equipment reservation after receiving a supplier lead-time quote. XAIPART analysis
XAIPART Forecast
XAIPART expects at least one published Vaillant aroTherm perform installation to document a cascade containing at least 2 connected heat pumps within 6 months; if no such configuration is documented, this forecast is wrong. This metric would provide procurement teams with an initial field reference for multi-unit controls, balancing and installation requirements. XAIPART analysis
Facts are as reported by the cited source. The design-in, sourcing and forward-looking statements above are XAIPART's analysis, not the source's claims. The report is a single-source account, and pricing, launch dates by market, installer availability, certification details and lead times were not disclosed.
Corrections: none at publication. This brief will be updated with a timestamp if the source corrects its report.
替代料与生命周期
| 料号 | 关系 | 生命周期 | 依据 |
|---|---|---|---|
| — | 暂无收录替代料 待补充数据 | — | 需 match_type 后才可显示任何前代标签 |
“前代”和“替代”标签仅来自已记录的匹配类型、生命周期状态或来源文本。没有记录匹配时,不显示任何标签。我们自己的商品列表不构成市场参考。
关注要点
| 论断 | 阈值 | 发布方 | 状态 |
|---|---|---|---|
| XAIPART expects at least one published Vaillant aroTherm perform installation to document a cascade containing at least 2 connected heat pumps within 6 months | no such configuration is documented | within 6 months | Pending |
被证明错误的预测仍保留可见并加以标注。我们不会删除它们。
竞争格局
- 2 个在售商品(XAIPART 此分类)
- 2 收录制造商
- 71 家制造商(过去 30 天内出现在我们的新闻存档中)
统计数据仅反映 XAIPART 目录,不代表市场份额。
受影响的料号
目录中无匹配。 此事件未映射到 XAIPART 当前上架的任何料号。我们不推断匹配,也不显示占位列表。
各维度成本压力
| Dimension | FRED series ID | Unit | Lag | As of |
|---|---|---|---|---|
| 投入成本 | PCOPPUSDM, PALUMUSDM, PNICKUSDM | USD/mt | 52 d | |
| 供需 | PCU334413334413, IPG3344S | index(1982=100) / index(2017=100) | 46 d | |
| 汇率与能源 | DEXCHUS, DCOILBRENTEU, DHHNGSP | rate / USD/bbl / USD/MMBtu | 5 d |
No free authoritative interface for: gold · silver · rare earth · polysilicon · lithium carbonate · market share — listed rather than approximated.
本文如何生成
过程证据——抓取、来源可靠性检查、模型与校验
| Source fetched | PV Magazine · www.pv-magazine.com · 3,325 chars · fetch status success |
|---|---|
| Source sanity (S1) | ok — passed before any model call (no s1_ block recorded) |
| Model / prompt | MiniMax-M3.1-Flash · prompt Blog Agent - News Summary (v2.8-final) · 8,251 tokens · 38.8s · run completed |
| Gate | verdict pass · 6/6 applicable checks passed · spec v2.9 · C10 ratio 0.033696 · C10 rounds 0 |
| Time contract | 3 <time datetime> values in this brief — 0 violations (+08:00 or date-only) |
上述每一行均由流水线生成,而非人工撰写。
评论
成为第一个评论的人。
🔐 请 登录 即可发表评论。
还没有账户? 注册