Vaillant launched the aroTherm perform monobloc air-to-water heat pump for large residential buildings, renovation projects and small commercial properties.S1 The series is available in 15 kW and 20 kW classes.S1 According to Vaillant, the larger model can supply space heating and domestic hot water for new buildings up to 1,200 m², renovated buildings up to 750 m² and non-renovated properties up to 500 m².S1
The system uses propane refrigerant R290 and can reportedly produce 75 C supply water at an outdoor temperature of -10 C without auxiliary heat.S1 At -15 C ambient temperature, it can deliver supply temperatures up to 70 C.S1 Vaillant documentation lists the VWL 205/8.1 A S2 Q at 11.2 kW heating capacity and 5.66 COP at A7/W35; at A-7/W35, output reaches 19.6 kW with a 2.6 COP.S1
The series carries an A+++ classification at 55 C supply temperature.S1 Reported SCOP values reach 5.44 for the 15 kW model and 5.35 for the 20 kW model at 35 C under average climate conditions.S1 The outdoor unit measures approximately 1,230 mm × 1,890 mm × 788 mm, weighs around 310 kg and requires a 400 V three-phase electrical supply.S1 The 20 kW version has a reported sound power level of 50 dB(A) under ErP rating conditions and a maximum of approximately 63 dB(A); night mode can reduce emissions by up to 10 dB(A).S1
Flexible Space Function is intended to ease outdoor-unit placement near windows and doors while retaining applicable propane safety requirements.S1 The aroTherm perform also includes the iQconnect platform, a 7-inch touchscreen, commissioning assistance, remote monitoring, over-the-air updates, myVaillant app control, energy-management integration and rooftop photovoltaic integration.S1 Up to six heat pumps can reportedly operate in a cascade configuration.S1
| Metric | Reported value | Source |
|---|---|---|
| Capacity classes | 15 kW and 20 kW | S1 |
| A7/W35 heating capacity | 11.2 kW | S1 |
| A7/W35 COP | 5.66 | S1 |
| A-7/W35 heating output | 19.6 kW | S1 |
| A-7/W35 COP | 2.6 | S1 |
| Maximum cascade size | 6 heat pumps | S1 |
| Electrical supply | 400 V three-phase | S1 |
| Maximum sound power | Approximately 63 dB(A) | S1 |
Background timeline
XAIPART take
Technical impact
For engineering teams, the low-temperature performance points are more useful than the nominal class label: the documented 19.6 kW result at A-7/W35 provides a practical starting point for winter heat-load calculations. Projects should request full operating maps rather than infer output from the 20 kW designation, especially where the design temperature differs from -7 C. XAIPART analysis
Market impact
R290 equipment adds propane-handling and placement constraints to procurement scope, while the three-phase supply requirement may affect electrical design and site upgrades. Buyers should treat local installer capability, safety-zone compliance and appliance availability as separate qualification items. Vaillant did not disclose pricing, channel availability or lead times, so buyers cannot use this report to compare supply risk or landed cost. XAIPART analysis
Action
Request the aroTherm perform technical documentation, noise data and cascade controls package before specifying the VWL 205/8.1 A S2 Q. Confirm design heat loads, domestic-hot-water demand, electrical capacity and applicable propane installation rules with the mechanical contractor and authority having jurisdiction. Check whether project schedules require early equipment reservation after receiving a supplier lead-time quote. XAIPART analysis
XAIPART Forecast
XAIPART expects at least one published Vaillant aroTherm perform installation to document a cascade containing at least 2 connected heat pumps within 6 months; if no such configuration is documented, this forecast is wrong. This metric would provide procurement teams with an initial field reference for multi-unit controls, balancing and installation requirements. XAIPART analysis
Facts are as reported by the cited source. The design-in, sourcing and forward-looking statements above are XAIPART's analysis, not the source's claims. The report is a single-source account, and pricing, launch dates by market, installer availability, certification details and lead times were not disclosed.
Corrections: none at publication. This brief will be updated with a timestamp if the source corrects its report.
대체품 및 수명 주기
| 부품 | 관계 | 수명 주기 | 근거 |
|---|---|---|---|
| — | 등록된 대체품 없음 데이터 필요 | — | 요구 사항 match_type 어떤 전임자 라벨이 표시되기 전에 |
"전임자" 및 "대체품" 라벨은 기록된 일치 유형, 수명 주기 상태 또는 출처 텍스트에서만 부여됩니다. 일치가 기록되지 않은 경우 라벨이 표시되지 않습니다. 당사 자체 등록 상품은 시장 기준이 아닙니다.
주시할 사항
| 주장 | 임계값 | 작성: | 상태 |
|---|---|---|---|
| XAIPART expects at least one published Vaillant aroTherm perform installation to document a cascade containing at least 2 connected heat pumps within 6 months | no such configuration is documented | within 6 months | Pending |
잘못된 예측도 계속 표시하고 표시를 남깁니다. 삭제하지 않습니다.
경쟁 구도
- 2 XAIPART의 이 카테고리 활성 등록 상품
- 2 등록된 제조사
- 71 최근 30일간 뉴스 아카이브에 언급된 제조사
수치는 XAIPART 카탈로그만 반영하며 시장 점유율이 아닙니다.
영향받는 부품
카탈로그 일치 없음. 이 보도는 현재 XAIPART에 등록된 어떤 부품과도 매핑되지 않습니다. 일치를 추론하지 않으며 자리 표시자 목록도 표시하지 않습니다.
차원별 비용 압력
| Dimension | FRED series ID | Unit | Lag | As of |
|---|---|---|---|---|
| Input cost | PCOPPUSDM, PALUMUSDM, PNICKUSDM | USD/mt | 52 d | |
| Supply/demand | PCU334413334413, IPG3344S | index(1982=100) / index(2017=100) | 46 d | |
| FX & energy | DEXCHUS, DCOILBRENTEU, DHHNGSP | rate / USD/bbl / USD/MMBtu | 5 d |
No free authoritative interface for: gold · silver · rare earth · polysilicon · lithium carbonate · market share — listed rather than approximated.
이 콘텐츠의 제작 방식
프로세스 증거 — 수집, 출처 온전성, 모델 및 게이트
| Source fetched | PV Magazine · www.pv-magazine.com · 3,325 chars · fetch status success |
|---|---|
| Source sanity (S1) | ok — passed before any model call (no s1_ block recorded) |
| Model / prompt | MiniMax-M3.1-Flash · prompt Blog Agent - News Summary (v2.8-final) · 8,251 tokens · 38.8s · run completed |
| Gate | verdict pass · 6/6 applicable checks passed · spec v2.9 · C10 ratio 0.033696 · C10 rounds 0 |
| Time contract | 3 <time datetime> values in this brief — 0 violations (+08:00 or date-only) |
위의 모든 행은 파이프라인에서 생성되며 수작업으로 작성되지 않습니다.
댓글
첫 번째 댓글을 남겨 보십시오.
🔐 먼저 로그인 댓글을 게시하려면
계정이 없으십니까? 회원가입