AD629ARZ - ±270V Difference Amplifier | Analog Devices
料号: AD629ARZ ✓ 量产中AD629ARZ 概述
A difference amplifier measures the voltage difference between two inputs while rejecting their common-mode component. In the power-management hierarchy, the AD629 belongs to the amplifier family, specifically the difference-amplifier and instrumentation-amplifier application class. This distinction is important because the input stage must tolerate a high common-mode voltage without compromising the accuracy of the much smaller differential signal being measured.
Key features include an input common-mode range of up to ±270 V, a factory-set gain of 1, low differential input offset voltage of 1 mV, a gain bandwidth of 500 kHz, and an operating-temperature range from −40°C to +85°C. These characteristics suit power-supply monitoring, high-side current sensing, battery management, and industrial instrumentation where the signal of interest is smaller than the switching or supply voltage around it.
The AD629ARZ uses an internal resistor arrangement to establish its nominal gain, so applications do not require an external feedback network for normal operation. Applying a voltage between REF(+) and REF(−) shifts the output relationship and enables unipolar or bipolar output operation. The manufacturer cautions that the usable input common-mode range changes when a single-supply configuration or reference voltage restricts the internal amplifier nodes.
Typical uses include measuring shunt voltage in high-voltage power rails, monitoring isolated bus systems, detecting current in motor-control systems, and conditioning sensor signals in industrial equipment. The 8-pin SOIC package supports conventional surface-mount assembly but requires careful attention to high-voltage clearance, creepage, input protection, grounding, and leakage around the measurement network.
For a new design, verify absolute maximum input voltage, supply range, gain accuracy, common-mode rejection, and thermal limits against the operating conditions before committing the PCB. Keep sensitive input traces short, maintain the required spacing for high-voltage nodes, and use the pin-description table in the manufacturer datasheet when assigning tracks and isolation boundaries.
This page consolidates manufacturer specifications, sourcing guidance, verified drop-in comparisons, and application-specific design guidance for engineers evaluating the AD629ARZ in high-common-mode measurement circuits.
直接替换替代料: AD629ARZ ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: AD629ARZ (相同外形与封装尺寸) ——差异在于 Package, Product Type, Operating Temperature Range, Gain, RoHS Status.
AD629ARZ-R7
✅ 直接替换联系询价
查看数据手册 →AD629BR
✅ 直接替换联系询价
查看数据手册 →AD629ARZ-RL
✅ 直接替换联系询价
查看数据手册 →INA117KU/2K5
✅ 直接替换联系询价
查看数据手册 →AD629ARZ 最大额定值与电气特性
| Product Type | High common-mode-voltage difference amplifier |
| Number of Amplifiers | 1 amplifier |
| Input Common-Mode Voltage Range | Up to ±270 V |
| Nominal Gain | 1 V/V |
| Differential Input Offset Voltage | 1 mV |
| Gain Bandwidth | 500 kHz |
| 工作温度范围 | −40°C to +85°C |
| 封装 | 8-lead SOIC |
| 安装类型 | Surface mount |
| Reference Input | REF(+) and REF(−) inputs |
| Product Status | Production |
| Manufacturer Order Quantity | 1,000 units |
AD629ARZ 8-lead soic 引脚配置指南
AD629ARZ(8-lead soic 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: AD629ARZ.
请参阅 数据手册 以查看完整引脚配置。
典型应用
AD629ARZ 适用于 6 应用s: High-Side Power-Rail Current Sensing, Battery Management and Pack Monitoring, Motor Drive and Industrial Control, Power-Supply Telemetry and Fault Detection, Instrumentation and Sensor Signal Conditioning, High-Voltage Feedback and Reference Systems.
High-Side Power-Rail Current Sensing
The AD629ARZ fits high-side current sensing because it can measure a small differential shunt voltage while the two inputs experience a common-mode voltage of up to ±270 V. Its fixed gain of 1 V/V simplifies signal-chain scaling when the shunt resistance and full-scale current are already selected. Place the amplifier across the shunt and keep the differential loop compact so PCB leakage and parasitic inductance do not dominate the measurement. The designer must still verify the actual common-mode voltage, supply limits, input bias error, and thermal condition against the manufacturer’s operating specifications. This arrangement is useful in industrial power supplies, motor controllers, and battery systems where fault detection depends on measuring current rather than the full supply waveform.
推荐
Battery Management and Pack Monitoring
The AD629ARZ can monitor small voltage differences in battery systems where the pack voltage is much larger than the signal being measured. Its input common-mode range of up to ±270 V provides margin for high-energy industrial battery architectures, while the 1 V/V gain preserves a straightforward relationship between shunt voltage and output. The amplifier is placed across the sensing element, with the supply and reference arrangement selected to prevent output saturation. Engineers should account for cell imbalance, transient voltage, shunt power, and the device’s 500 kHz bandwidth when designing the protection path. This application is especially relevant to battery packs, industrial energy storage, and backup-power systems requiring accurate current information for balancing and fault detection.
推荐
Motor Drive and Industrial Control
The AD629ARZ is appropriate for motor-control and industrial automation circuits that must reject a large switching common-mode voltage while extracting a low-level control signal. The ±270 V common-mode capability allows measurement near high-side power stages, and the 500 kHz gain bandwidth supports signal content beyond static DC measurement. The output can be routed to an analog-to-digital converter or comparator for current limiting and diagnostics. Layout must separate the high-voltage input node from sensitive control traces, while the reference network must preserve the available common-mode range. The 8-lead SOIC package is practical for industrial control boards, but its isolation and creepage requirements are determined by the actual working voltage and environmental contamination level.
推荐
Power-Supply Telemetry and Fault Detection
The AD629ARZ can produce a low-voltage indication of current or rail condition by differentiating two high-side potentials. Its fixed 1 V/V gain means the shunt differential voltage is reproduced at the output without an external feedback network, reducing the number of precision resistors in the signal path. This is useful in power-supply telemetry where the controller must monitor overload, short-circuit, or load changes without directly exposing sensitive circuitry to the full bus voltage. Check the amplifier’s output range against the ADC input, account for saturation during a fault, and place the shunt and amplifier to minimize loop area. The result is a compact analog monitoring channel for laboratory, telecom, and industrial power modules.
推荐
Instrumentation and Sensor Signal Conditioning
The AD629ARZ can condition a differential sensor signal when both sensing nodes ride on a high common-mode potential. Its fixed 1 V/V gain avoids the external gain-setting network normally required by a general-purpose difference amplifier, while the 1 mV offset specification supports precision measurement. The result can drive a higher-level instrumentation or ADC stage without recovering a large common-mode voltage at the output. Designers should verify the sensor source impedance because input bias current and imbalance can create offset, and they should confirm that the output remains within its swing limits. The device is suitable for industrial sensor interfaces, test equipment, and high-side sensing arrangements where accuracy and simplicity of gain configuration are priorities.
推荐
High-Voltage Feedback and Reference Systems
The AD629ARZ can be used in feedback systems that measure a small correction signal across a high-voltage network. With a nominal gain of 1 V/V, it presents a direct differential-voltage output and can be combined with a reference input to establish the desired output offset. Because applying a reference changes the internal operating conditions and potentially narrows the usable input common-mode range, the reference voltage and supply rails must be calculated before layout release. Keep the high-voltage loop short and place the output connection away from sensitive analog nodes. This approach supports laboratory feedback fixtures, regulated high-voltage supplies, and precision control loops where conventional low-voltage amplifiers cannot tolerate the instantaneous common-mode voltage.
推荐
推荐产品汇总
工程参考数据: AD629ARZ ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | AD629AR | AD629BR | AD629ARZ-RL | INA117 | INA117KU |
|---|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Texas Instruments | Texas Instruments |
| Package | 8-lead SOIC | 8-lead SOIC | 8-lead SOIC | 8-lead SOIC | 8-lead SOIC | 8-lead SOIC |
| Product Type | High common-mode-voltage difference amplifier | High common-mode-voltage difference amplifier | High common-mode-voltage difference amplifier | High common-mode-voltage difference amplifier | High common-mode current-sense amplifier | High common-mode current-sense amplifier |
| Nominal Gain | 1 V/V | 1 V/V | 1 V/V | 1 V/V | 1 V/V | 1 V/V |
关键差异点
- Very high common-mode input capability (对比 INA117)
- Fixed, resistor-free nominal gain configuration (对比 INA117)
- Precision-grade family option for tighter DC accuracy (对比 AD629ARZ)
设计说明
Treat the input network as a high-voltage differential measurement structure. Keep the AD629ARZ input pins, shunt connections, and sensitive traces short, route the two inputs as a close differential pair where practical, and place input protection outside the measurement loop. Maintain the creepage and clearance required by the maximum working voltage and environmental contamination level. The common-mode capability of up to ±270 V does not remove PCB isolation requirements.
Do not assume the full ±270 V input common-mode range remains available in every reference configuration. Analog Devices states that applying a voltage between REF(+) and REF(−) changes the internal operating conditions and can reduce the usable input range. Calculate the supply and reference arrangement at the highest and lowest expected input voltages, including fault transients, and verify the output remains inside its valid range.
Account for source-imbalance effects rather than relying only on the 1 mV offset specification. Differences between the two source impedances convert input bias current into differential error, and parasitic resistance from long traces adds directly to the sensed voltage. Use symmetric input routing, suitable source impedances, and local filtering that does not disturb the intended measurement bandwidth. Confirm the final error budget at the device’s 500 kHz gain-bandwidth limit.
合规信息
Individual material-compliance declarations are not exposed in the available product information. Confirm current RoHS, REACH, lead-free, halogen-free, and conflict-minerals documentation with Analog Devices before a regulated production release.