ADM3491AN-1 - 3.3V 20Mbps RS-485/RS-422 Transceiver | Analog Devices
料号: ADM3491AN-1 ✓ 量产中ADM3491AN-1 概述
A differential line transceiver is an interface IC that transmits data across balanced, noise-resistant lines while receiving signals with high common-mode rejection. RS-485 supports robust multipoint communication over relatively long cable runs, whereas RS-422 emphasizes full-duplex point-to-point links. Within the interface hierarchy, the ADM3491AN-1 belongs to the RS-485/RS-422 transceiver class, connects digital controllers to physical communication lines, and operates as part of a broader industrial communications system.
Key features include a single 3.3 V power supply, low-power operation, full-duplex communication, and a shutdown function. The identified low-power figure is 840 uA, while the cited data rate reaches 20 Mbps. Its differential driver and receiver architecture provides a practical balance between communication throughput, power consumption, and system complexity. The separate driver and receiver paths support simultaneous transmission and reception in full-duplex RS-422 networks.
The ADM3491 family is intended for balanced data transmission and supports both Electronic Industries Association RS-485 and RS-422 interfaces. Communication protocols can use the transceiver as the physical-layer interface beneath UART, industrial automation, instrumentation, or industrial Ethernet equipment. The 3.3 V supply also allows direct integration with modern low-voltage controllers, reducing the need for level-shift or separate line-driver circuitry.
Typical uses include industrial control links, factory automation nodes, sensor and instrumentation networks, building-control equipment, and data-acquisition systems. In these applications, the balanced line helps reject common-mode noise encountered near motors, relays, and long cables. The 20 Mbps capability is useful for links that require higher throughput than conventional low-speed RS-485 nodes while retaining the simplicity of a serial differential interface.
PCB design should preserve the differential signal path, use a continuous ground reference, and place termination and protection components near the line interface. The shutdown control should be driven only after the transmitter and receiver signals are placed in a safe state. Operating temperature, enable polarity, receiver fail-safe behavior, and electrical limits should be confirmed against the manufacturer datasheet before production release.
This page combines the device function, verified operating characteristics, package information, interface-design guidance, and comparison criteria for evaluating the ADM3491 family against compatible interface transceivers.
直接替换替代料: ADM3491AN-1 ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: ADM3491AN-1 (相同外形与封装尺寸) ——差异在于 Mounting Type, Package, Supply Voltage, Logic Compatibility, Maximum Data Rate.
ADM3491AN
✅ 直接替换联系询价
查看数据手册 →ADM3491ARZ
✅ 直接替换联系询价
查看数据手册 →ADM3491-1
✅ 直接替换📋 参考替代料(不在目录中)
ADM3491AN-1 规格参数
| Product Type | Low-power differential RS-485/RS-422 line transceiver |
| 电源电压 | 3.3 V |
| Maximum Data Rate | 20 Mbps |
| Low-Power Consumption | 840 uA |
| Supported Standards | EIA RS-485 and RS-422 |
| Communication Mode | Full duplex |
| Driver Architecture | Differential line driver |
| Receiver Architecture | Differential line receiver |
| Power-Down Feature | Yes, shutdown mode |
| 封装 | 14-lead SOIC |
| 安装类型 | Surface mount |
ADM3491AN-1 14-lead soic 引脚配置指南
ADM3491AN-1(14-lead soic 封装)的引脚配置。 引脚编号、功能和连接图在制造商数据手册中定义。请参阅该手册以了解确切的封装尺寸和焊接指南。
暂无详细引脚数据: ADM3491AN-1.
请参阅 数据手册 以查看完整引脚配置。
典型应用
ADM3491AN-1 适用于 6 应用s: Industrial Automation Serial Links, Factory Sensor Networks, Instrumentation and Test Equipment, Building Control Networks, Data Acquisition Systems, Power-Sensitive Communication Modules.
Industrial Automation Serial Links
The ADM3491AN-1 fits industrial automation equipment that needs a balanced, noise-resistant communication interface on a 3.3 V power rail. Its integrated differential driver and receiver support full-duplex RS-422 or RS-485 links, while the cited 20 Mbps capability provides more throughput than required for slow sensor polling. The low-power figure of 840 uA and shutdown mode help control system consumption when a node is inactive. In a controller or remote I/O module, the transceiver can connect a serial processor directly to a field cable, subject to the manufacturer’s enable, termination, and loading requirements.
推荐
Factory Sensor Networks
The ADM3491AN-1 is suitable for factory sensor networks where cables run near relays, motor drives, and switching equipment. Differential signaling rejects common-mode noise better than a single-ended serial interface, while the 3.3 V supply can simplify integration with sensor controllers and gateways. Its full-duplex architecture can support dedicated transmit and receive paths where RS-422 point-to-point wiring is used. The 840 uA cited low-power figure makes the device relevant to distributed nodes, although overall node consumption must include the host processor, isolation, and cable-driver loading.
推荐
Instrumentation and Test Equipment
The ADM3491AN-1 supports balanced serial connections in instrumentation and test equipment where a compact, low-voltage physical-layer interface is required. The differential receiver and driver are appropriate for communicating between a controller and external measurement equipment over RS-422, while the transceiver also supports RS-485 networks. Its listed 20 Mbps rate accommodates data-intensive instrument links and provides margin for shorter, well-controlled connections. The shutdown function can disable the interface during idle periods, and the 14-lead SOIC package simplifies assembly on conventional mixed-signal boards.
推荐
Building Control Networks
The ADM3491AN-1 can serve as the balanced line interface in building-control equipment connected to distributed sensors, actuators, or access-control nodes. A single 3.3 V supply is convenient for low-power controllers, while differential signaling improves robustness against common-mode disturbances found in building wiring. The device supports RS-485 and RS-422, allowing designers to match the topology to cable length and communication architecture. Its full-duplex operation supports simultaneous command and status traffic when separate balanced pairs are used, and shutdown mode can reduce consumption during inactive periods.
推荐
Data Acquisition Systems
The ADM3491AN-1 is appropriate for distributed data-acquisition systems that transfer sensor, status, or configuration data over balanced copper links. Its differential driver and receiver reduce susceptibility to common-mode noise, and the 3.3 V operation can interface directly with modern embedded controllers. The cited 20 Mbps capability is useful where acquisition nodes transmit compact data bursts or where short laboratory and industrial cables support higher rates. Designers should use the datasheet timing limits to preserve adequate rise and fall time at the selected baud rate.
推荐
Power-Sensitive Communication Modules
The ADM3491AN-1 fits compact communication modules that prioritize low power and a single 3.3 V supply. Its low-power figure of 840 uA, differential communication paths, and shutdown mode allow the physical interface to remain efficient while inactive. The device can bridge a low-voltage controller to an RS-485 or RS-422 network without adding a separate line-driver package. Because the 20 Mbps maximum is a headline capability rather than a universal cable-rate guarantee, designers should select baud rate and cable length together and apply the appropriate termination and protection network.
推荐
推荐产品汇总
工程参考数据: ADM3491AN-1 ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | ADM3491AN | ADM3491ARZ | ADM3491-1 |
|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | 14-lead SOIC | 14-lead SOIC | 14-lead SOIC | 14-lead SOIC |
| Supply Voltage | 3.3 V | 3.3 V | 3.3 V | 3.3 V |
| Communication Mode | Full duplex | Full duplex | Full duplex | Full duplex |
| Supported Standards | EIA RS-485 and RS-422 | EIA RS-485 and RS-422 | EIA RS-485 and RS-422 | EIA RS-485 and RS-422 |
| Driver and Receiver Architecture | Differential driver and differential receiver | Differential driver and differential receiver | Differential driver and differential receiver | Differential driver and differential receiver |
| Shutdown Function | Yes | Yes | Yes | Yes |
| Lifecycle Status | Active | Active | Active | Active |
关键差异点
- Higher cited throughput within the ADM3491 family ordering options (对比 ADM3491ARZ)
- Single low-voltage supply simplifies controller integration (对比 ADM3491-1)
- Full-duplex balanced interface with integrated shutdown (对比 ADM3491AN)
设计说明
Route the differential bus as a tightly matched pair with continuous ground beneath it, and keep the transceiver interface section away from switching nodes and high-current return paths. Place termination, biasing, and protection components near the bus connector or transceiver pins, whichever is electrically appropriate for the topology. Maintain a low-impedance ground return beneath the pair and avoid long stubs because they can degrade signal integrity and alter the usable bus rate.
Decouple the 3.3 V supply close to the transceiver supply pins with the capacitance and voltage rating specified by the manufacturer. Keep the shutdown control in a defined state during reset so the transmitter cannot drive the bus unexpectedly. Before enabling the driver, apply the required bus-idle condition so that multiple nodes do not conflict during startup. Account for the transceiver’s load current, supply noise, and line-driver dissipation in the rail and thermal design.
Do not select RS-485 and RS-422 termination and biasing as if the interfaces were electrically identical. RS-485 commonly uses termination at both cable ends and may require fail-safe biasing, while a full-duplex RS-422 point-to-point link normally uses termination only at the receiver end. Confirm enable polarity, receiver output state during shutdown, and cable-length-versus-baud-rate limits in the ADM3491 manufacturer datasheet before releasing the PCB.
The cited 20 Mbps capability should be treated as a device-level maximum rather than a guarantee for every cable, topology, or protection network. Use controlled-impedance wiring, minimize stub lengths, and evaluate rise and fall time at the receiver when operating near the upper rate limit. If the application requires longer cables or lower power, reduce the baud rate and validate the complete bus with representative cable lengths and grounding conditions.
合规信息
The ADM3491 product materials identify the family as a 3.3 V RS-485/RS-422 transceiver, but no specific RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declaration was confirmed for the exact ADM3491AN-1 ordering code.