ADM3491ARZ - 3.3V Full-Duplex RS-485/RS-422 | Analog Devices
料号: ADM3491ARZ ✓ 量产中ADM3491ARZ 概述
A differential line transceiver is an interface integrated circuit that combines a transmitter and receiver to communicate over balanced, differential pairs. RS-422 is commonly used for point-to-point links, while RS-485 supports multipoint buses. These standards belong to the broader wired-data-interface hierarchy, where transceivers connect low-voltage digital logic to external cables carrying larger-amplitude differential signals.
Key features include a 3.3 V operating supply, 10 Mbps maximum signaling rate, 19 kΩ receiver input impedance, and support for up to 50 transceivers on a bus. The receiver remains compatible with 5 V logic, which simplifies interfaces between newer 3.3 V systems and older digital controllers. A shutdown mode reduces supply current to 2 nA, making the device suitable for power-sensitive systems that are intermittently active.
The ADM3491 family provides EIA RS-422 and RS-485 compliance across the full common-mode range. Its 8 ns transmit skew supports balanced timing between differential outputs, while reduced slew rates on related family members address electromagnetic-interference requirements. Short-circuit protection and thermal shutdown improve robustness when a driver encounters an abnormal bus condition.
Typical uses include industrial automation links, data acquisition equipment, building-control systems, instrumentation, and communications equipment requiring a full-duplex balanced interface. The 10 Mbps capability is appropriate for factory-floor links, while the 19 kΩ input impedance permits multiple receivers on a bus without excessive loading.
PCB design should preserve the differential signal path and provide a controlled return route. Place input and output bypassing capacitors close to their associated supply pins, and keep connector and protection-device return currents from crossing the differential pair. Confirm the exact pin names and exposed connections in the manufacturer datasheet before assigning PCB nets.
This page combines application guidance, engineering design notes, and structured cross-reference information to support faster transceiver selection and board bring-up. The ADM3491ARZ is suited to engineers who need a compact, low-power, 3.3 V full-duplex RS-422 or RS-485 interface with 10 Mbps operation.
直接替换替代料: ADM3491ARZ ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: ADM3491ARZ (相同外形与封装尺寸) ——差异在于 Product Type, Package, Maximum Data Rate, Logic Compatibility, Receiver Input Impedance.
ADM3491AR-1
✅ 直接替换📋 参考替代料(不在目录中)
ADM3491ARZ-1
✅ 直接替换📋 参考替代料(不在目录中)
ADM3491-1
✅ 直接替换📋 参考替代料(不在目录中)
ADM3491ARZ-REEL7
✅ 直接替换📋 参考替代料(不在目录中)
ADM3491ARZ 规格参数
| Product Type | Full-duplex differential line transceiver |
| Supported Standards | EIA RS-422 and EIA RS-485 |
| 电源电压 | 3.3 V |
| Maximum Data Rate | 10 Mbps |
| Receiver Input Impedance | 19 kΩ |
| Maximum Transceivers per Bus | 50 transceivers |
| 电源电流 | 840 µA |
| 关断电流 | 2 nA |
| Logic Compatibility | 5 V logic interoperable |
| Transmit Skew | 8 ns |
| Common-Mode Range | Full common-mode range |
| Short-Circuit Protection | Yes |
| 热关断 | Yes |
| 工作温度 | -40 °C to +85 °C |
| 封装 | 14-lead SOIC |
| 安装类型 | Surface mount |
| EIA RS-485 Transient Immunity | IEC 1000-4-4 above 1 kV |
ADM3491ARZ 14-lead soic 引脚配置指南
ADM3491ARZ(14-lead soic 封装)的引脚配置。 引脚编号、功能和连接图在制造商数据手册中定义。请参阅该手册以了解确切的封装尺寸和焊接指南。
暂无详细引脚数据: ADM3491ARZ.
请参阅 数据手册 以查看完整引脚配置。
典型应用
ADM3491ARZ 适用于 6 应用s: Industrial Automation Bus Interface, Factory Data Acquisition, Building Control Network, Instrumentation Communication, Point-to-Point Data Link, Power-Sensitive Sensor Node.
Industrial Automation Bus Interface
The ADM3491ARZ fits industrial automation equipment that connects a 3.3 V controller to a balanced RS-485 or RS-422 field link. Its 10 Mbps maximum data rate supports high-speed command and telemetry traffic, while the 19 kΩ receiver input impedance permits up to 50 transceivers on a bus. The full-duplex arrangement provides separate transmit and receive paths, avoiding half-duplex turnaround delays. Its 840 µA operating current also suits compact controller boards. Deployment should include verified termination, common-mode protection, and an isolated or non-isolated grounding strategy matched to the installation.
推荐
Factory Data Acquisition
The ADM3491ARZ is appropriate for factory data-acquisition modules that must exchange measurements over a long balanced cable while operating from a 3.3 V system rail. Its 10 Mbps capability allows the interface to carry time-stamped sensor data and control updates without the low-speed constraints of common RS-485 transceivers. Short-circuit protection and thermal shutdown improve robustness against accidental bus faults. For installation, use twisted-pair routing, controlled terminations, surge protection, and a ground reference compatible with the transceiver’s full common-mode operating range.
推荐
Building Control Network
The ADM3491ARZ can connect building-control controllers, sensors, and gateways over RS-485 or RS-422. Its low 840 µA supply consumption benefits compact wall-mounted controllers, and the 2 nA shutdown current helps maintain low standby demand. The 10 Mbps rate is more than sufficient for typical HVAC, access, lighting, and environmental-control traffic while also accommodating higher-speed local diagnostics. Maintain a consistent reference ground and separate surge currents from the differential pair to prevent transient energy from perturbing the receiver.
推荐
Instrumentation Communication
The ADM3491ARZ is useful in laboratory and industrial instruments that expose a balanced communications port to a host controller. Its 3.3 V operation suits modern mixed-signal systems, and interoperability with 5 V logic helps connect the interface to established digital circuitry. The full-duplex topology allows command transmission and response reception to occur simultaneously, shortening instrument-control cycles. Designers should use the manufacturer pin definitions for the exact package and should validate cable length, baud rate, termination, and common-mode limits as a complete channel.
推荐
Point-to-Point Data Link
The ADM3491ARZ supports point-to-point balanced links where full-duplex operation is valuable, including equipment-to-controller and board-to-board communications. Separate differential transmit and receive channels eliminate the need to share a bus pair, while the 10 Mbps rate supports rapid file transfer, configuration updates, and real-time control traffic. The 3.3 V supply and 840 µA operating current simplify integration with embedded systems. For long cable runs or electrically noisy environments, add appropriate transient protection and verify that the complete channel remains inside the supported common-mode range.
推荐
Power-Sensitive Sensor Node
The ADM3491ARZ fits low-power sensor nodes that communicate over a wired differential bus when wireless communication is unsuitable. Its 840 µA operating consumption and 2 nA shutdown current reduce demand when the node spends substantial time idle. The 19 kΩ receiver input impedance allows multiple nodes to share a bus, and the 10 Mbps rate supports aggregated telemetry. Keep the transceiver supply rail clean, bypass it close to the device, and use a shutdown strategy that avoids disrupting required bus-fail-safe behavior during low-power transitions.
推荐
推荐产品汇总
工程参考数据: ADM3491ARZ ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | ADM3491AR-1 | ADM3491ARZ-1 | ADM3491-1 | ADM3491ARZ-REEL7 |
|---|---|---|---|---|---|
| Package | 14-lead SOIC | 14-lead SOIC | 14-lead SOIC | 14-lead SOIC | 14-lead SOIC |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Product Type | Full-duplex differential transceiver | Differential transceiver | Differential transceiver | Differential transceiver | Full-duplex differential transceiver |
| Supply Voltage | 3.3 V | 3.3 V | 3.3 V | 3.3 V | 3.3 V |
| Supported Standards | EIA RS-422 and EIA RS-485 | EIA RS-422 and EIA RS-485 | EIA RS-422 and EIA RS-485 | EIA RS-422 and EIA RS-485 | EIA RS-422 and EIA RS-485 |
| Maximum Data Rate | 10 Mbps | 10 Mbps | 10 Mbps | 10 Mbps | 10 Mbps |
| Receiver Input Impedance | 19 kΩ | 19 kΩ | 19 kΩ | 19 kΩ | 19 kΩ |
| Supply Current | 840 µA | 840 µA | 840 µA | 840 µA | 840 µA |
| Shutdown Current | 2 nA | 2 nA | 2 nA | 2 nA | 2 nA |
关键差异点
- Full-duplex operation in a 14-lead package (对比 ADM3483EARZ-REEL7)
- Higher supported signaling rate within the ADM3491 family (对比 ADM3483EARZ-REEL7)
- Low-power operation with shutdown support (对比 ADM3491AR-1)
设计说明
Route the differential pair as a tightly coupled pair over a continuous reference plane, keeping both conductors over the same plane and avoiding splits, vias, and test pads that create impedance discontinuities. Connect the receiver and transmitter grounds consistently with the cable shield or chassis strategy used by the installation. High-current switching nodes and transient-protection return paths should remain outside the signal area so their current does not cross the differential traces.
Place the device bypass capacitor immediately adjacent to its supply and ground pins, with a short, low-impedance connection to the quiet ground plane. Keep the 3.3 V supply free of switching-converter ripple because receiver and transmit performance depend on a stable reference even though the specified supply current is only 840 µA. If the transceiver shares a board with switching circuitry, verify supply ripple and ground bounce at the device rather than relying only on the average current requirement.
Do not treat an 8-lead half-duplex transceiver as an automatic replacement for the ADM3491ARZ. The exact ADM3491ARZ is identified as a 14-lead, full-duplex device, and the physical signal paths differ from half-duplex implementations that share one bus pair. Also distinguish the -1 grade suffix from reel-orientation suffixes in the ordering code, and verify the operating-temperature range before approving a substitution.
Use twisted-pair cabling and proper bus termination to control reflections and radiated emissions. Where the installation exposes the bus to industrial surges, add a protection network selected for the required common-mode voltage and transient severity. The manufacturer datasheet identifies IEC 1000-4-4 compatibility above 1 kV for the family, but this does not remove the need to analyze the complete system and provide an appropriate energy-dissipation path.
合规信息
The family datasheet identifies IEC 1000-4-4 compatibility above 1 kV. RoHS, REACH, lead-free, halogen-free, conflict-minerals, and automotive-qualification status require confirmation for the exact ordering code.