ICL7107CQH+D - 3.5-Digit LED Display ADC | Analog Devices
料号: ICL7107CQH+D ✓ 量产中ICL7107CQH+D 概述
An ADC converts an analog input voltage into a numeric representation for measurement, display, or control. This device belongs to the display-driver ADC hierarchy: ADC → dual-slope ADC → LED display-driver ADC → integrated analog-to-digital conversion and display interface. Unlike a general-purpose ADC that requires an external display driver, the ICL7107 integrates the circuitry needed to operate a common-anode LED display directly. Its very high input impedance helps isolate the measured source from the conversion network.
The primary feature of the ICL7107CQH+D is its 3.5-digit measurement resolution. This resolution supports applications that require more indication precision than a simple one- or two-digit meter while retaining the simplicity of a dedicated panel-meter converter. Integrated display control reduces the number of external driver ICs and board-level connections. The converter architecture and display functions are provided on one monolithic device, reducing the component count of an integrated instrument panel.
The ICL7106 and ICL7107 share the same fundamental monolithic ADC concept and are specified in the same manufacturer family documentation. The key distinction is the display interface: the ICL7106 directly drives a nonmultiplexed liquid-crystal display, while the ICL7107 directly drives LED displays. This distinction is essential during component selection because exchanging these devices without reconciling the external display configuration can prevent correct operation even when the underlying conversion function is similar.
Typical uses include digital panel meters, laboratory readouts, temperature indicators, laboratory instruments, and other systems that combine a slowly varying analog measurement with a local seven-segment LED readout. The PLCC package provides 44 leads and is suited to through-hole assembly rather than compact surface-mount designs. The ceramic PLCC construction is particularly relevant when equipment uses a rugged through-hole panel-meter module or a design platform standardized around leaded display-driver ICs.
The most important design step is to implement the manufacturer’s typical application circuit, including the specified input, reference, clock, display, and bypass components. Review the pin-description table and display-drive guidance in the Analog Devices data sheet before assigning PCB connections. Because this page consolidates pricing, lifecycle information, application guidance, and related-family distinctions, it helps engineers assess fit before committing the 44-pin PLCC footprint to a new design.
Analog Devices lists the ICL7107 in production on its product page. The ICL7107CQH+D ordering code identifies the 44-pin PLCC version, while the + suffix denotes the manufacturer's lead-free ordering option. For purchasing decisions, use the exact ordering code and request a formal quote through the Request a Quote form on this page.
直接替换替代料: ICL7107CQH+D ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: ICL7107CQH+D (相同外形与封装尺寸) ——差异在于 Package, Mounting Type, Display Output, Function, Terminal Form.
该产品暂无直接替换替代料。
请求替代料ICL7107CQH+D 最大额定值与电气特性
| Converter Type | Dual-slope analog-to-digital converter |
| 分辨率 | 3.5 digits |
| Display Output | Direct LED display drive |
| Input Channels | 1 channel |
| Integrated Functions | Polarity driver, digit drivers, segment decoders, voltage reference, and clock circuit |
| 封装 | 44-pin PLCC, 16.59 mm × 16.59 mm |
| 引脚数量 | 44 pins |
| 安装类型 | Through-hole |
| Package Family | PLCC |
| Lead-Free Ordering | Yes, indicated by + suffix |
ICL7107CQH+D plcc 引脚配置指南
ICL7107CQH+D(plcc 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: ICL7107CQH+D.
请参阅 数据手册 以查看完整引脚配置。
典型应用
ICL7107CQH+D 适用于 6 应用s: Digital Panel Meters, Laboratory Measurement Instruments, Temperature Indicator Readouts, Industrial Process Readouts, Bench Power-Supply Monitoring, Digital Thermometers and Portable Indicators.
Digital Panel Meters
The ICL7107CQH+D is suitable for a digital panel meter that measures an analog voltage and presents the result on a seven-segment LED. Its 3.5-digit conversion format provides more displayed resolution than a basic one- or two-digit indicator, while the integrated digit drivers, segment decoders, and polarity driver reduce the external display-driver count. The converter is installed in a 44-pin PLCC footprint measuring 16.59 mm by 16.59 mm. Implement the input network, reference, clock, bypass, and display connections according to the manufacturer’s typical application circuit so that accuracy and display-drive timing remain consistent.
推荐
Laboratory Measurement Instruments
The ICL7107CQH+D can serve as the central measurement and display device in a laboratory instrument with a local numerical readout. The 3.5-digit dual-slope ADC converts the conditioned input, while the integrated clock and voltage-reference circuitry support a self-contained measurement channel. Direct LED drive simplifies the instrument front panel compared with a design that uses a standalone ADC and separate display driver. Because the converter has very high input impedance, it can help reduce loading of the measured source. Validate the complete analog front end and reference network against the manufacturer data sheet before claiming laboratory-grade accuracy.
推荐
Temperature Indicator Readouts
A temperature indicator can use the ICL7107CQH+D to convert a conditioned temperature-probe signal into a 3.5-digit LED display. The integrated display functions reduce the number of components between the analog measurement stage and the visible readout, while the dual-slope architecture is appropriate for a slowly changing temperature measurement. The 44-pin PLCC package provides ample connections for the converter, display, reference, and timing functions in a through-hole meter design. Select the display’s common-anode or common-cathode configuration correctly and preserve the manufacturer’s recommended bypass and reference layout to achieve stable readings.
推荐
Industrial Process Readouts
The ICL7107CQH+D fits industrial equipment that must show a process variable locally, such as pressure, load, or supply measurements. A 3.5-digit readout is more informative than a coarse indicator, and integrating the LED drivers within the converter simplifies the display subsystem. The through-hole 44-pin PLCC package is appropriate for equipment platforms designed around leaded components and serviceable meter modules. The analog input must remain within the converter’s specified range, and the display and reference networks must follow the manufacturer’s circuit. Confirm environmental and qualification requirements separately for each finished industrial product.
推荐
Bench Power-Supply Monitoring
The ICL7107CQH+D can provide the local numeric display in a bench power-supply or power-monitor instrument. A conditioned output-voltage or current signal can be converted into a 3.5-digit result, while integrated LED drive eliminates a separate display-driver IC. This arrangement keeps the instrument readout close to the measurement electronics and provides a clear operator display. Use appropriate scaling and input protection so the converter receives only the permitted voltage range. Follow the manufacturer’s reference and bypass recommendations to reduce output instability, and verify the selected LED display polarity and segment connections on the production schematic.
推荐
Digital Thermometers and Portable Indicators
The ICL7107CQH+D is appropriate for a standalone digital thermometer or portable indicator that uses an LED readout and a slowly changing sensor signal. Its 3.5-digit result provides useful display resolution, and the integrated digit and segment drivers reduce assembly complexity. The device’s very high input impedance helps when the sensor signal must pass through a high-value or high-impedance network. The 44-pin PLCC package is larger than a modern surface-mount solution, so this choice is most appropriate for through-hole products, educational instruments, or legacy meter platforms where a leaded display converter is already part of the mechanical design.
推荐
推荐产品汇总
工程参考数据: ICL7107CQH+D ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 |
|---|---|
| Package | 44-pin PLCC (16.59 mm × 16.59 mm) |
| Brand | Analog Devices |
| Converter Architecture | Dual-slope ADC |
| Resolution | 3.5 digits |
| Display Type | Direct LED display drive |
| Input Channels | 1 channel |
| Integrated Clock | Yes |
| Integrated Voltage Reference | Yes |
| Mounting Style | Through-hole PLCC |
| Lifecycle Status | Production |
| Ordering Suffix | + lead-free |
关键差异点
- Integrated LED display control (对比 ICL7106CQH-D)
- Measurement resolution in a display-driver converter (对比 ICL7106CQH-D)
- Production status from the original manufacturer (对比 ICL7116CQH+D)
设计说明
Implement the ICL7107CQH+D around the manufacturer’s typical application circuit and assign every one of the 44 PLCC terminals from the official pin-description table. Place the input, reference, clock, and bypass components at the locations shown in the application circuit, and route the seven-segment display outputs away from sensitive analog inputs. The 16.59 mm × 16.59 mm ceramic PLCC footprint requires adequate spacing around the leads for soldering, inspection, and through-hole assembly.
Keep the analog input and reference routing short, with a continuous ground reference beneath the sensitive section where the package and board construction permit. Decouple supply pins at the IC rather than sharing long supply traces among several display-related loads. Because the ICL7107CQH+D combines an analog conversion channel with digital display outputs, route display-driver currents away from the input and reference nodes to reduce coupling into the measured signal.
Do not substitute the ICL7106CQH-D for the ICL7107CQH+D without changing the display interface. The ICL7106 directly drives a nonmultiplexed LCD, while the ICL7107 directly drives an LED display, even though related family members can use the same 44-pin PLCC package. Also verify the display’s common-anode or common-cathode arrangement, segment mapping, and digit-driver polarity against the manufacturer documentation before releasing PCB artwork.
Use the manufacturer’s specified supply range and bypass network for the converter and display subsystem. The ICL7107’s integrated voltage reference and clock simplify the architecture, but they do not remove the need for clean local supply decoupling. Confirm the display current, converter supply requirement, and reference configuration independently, then validate startup and display readability at the minimum and maximum expected supply conditions.
合规信息
The + suffix indicates the lead-free ordering option. No explicit RoHS, REACH, AEC-Q100, halogen-free, or conflict-minerals statement was identified for this exact ordering code.