ICL7136CQH+D 概述

Analog Devices ICL7136CQH+D is a low-power, 3.5-digit dual-slope analog-to-digital converter with an integrated LCD display driver in a 44-pin PLCC package measuring 16.59 mm by 16.59 mm. It is designed for precision measurement systems that need differential input and reference behavior, automatic rejection of periodic interference, and direct LCD output without a separate display interface.

A dual-slope ADC is a voltage-to-digital conversion method that integrates an unknown input over a fixed interval and compares the result with a reference. It belongs to the ADC hierarchy, performs one analog-to-digital conversion function, and provides a multi-digit BCD result intended for digital panel meters. The ICL7136 family improves this architecture with a true differential input, a true differential reference, ratiometric measurement support, and a zero-integrator phase that reduces overrange hangover and hysteresis effects.

The ICL7136CQH+D combines low-power operation with a 3.5-digit readout and integrated LCD drive circuitry. Its differential input and reference arrangement is useful for bridge transducers, resistance measurement, and other ratiometric sensors because the result can depend on the ratio between the measured quantity and the excitation reference. The automatic rejection of periodic interference helps reduce errors from common industrial noise sources. The integrated display driver reduces the need for separate logic in standalone instrumentation.

The zero-integrator phase is a significant implementation detail. Following overrange, the converter returns its integrator toward zero rather than immediately beginning another measurement with residual charge. This feature improves recovery behavior and helps avoid overrange-related hysteresis. The converter also supports dual-slope conversion, which trades conversion speed for noise rejection and is especially useful when the measured signal changes more slowly than the conversion cycle.

Typical uses include digital panel meters, laboratory measurement instruments, process monitoring, weighing systems, temperature bridges, and portable meters with LCD displays. For bridge-based sensors, ratiometric operation can compensate for many excitation-voltage variations. For applications requiring higher throughput, software-controlled switching systems, or electrical isolation, a modern sigma-delta or successive-approximation ADC may be a better architectural choice than the ICL7136CQH+D.

Use the pin-description table in the manufacturer datasheet to assign signals to all 44 PLCC leads, and confirm the required reference, input, bypass, display, and logic connections before layout release. Preserve the specified input and reference grounding strategy because differential measurements can be sensitive to common-mode voltage and leakage. Confirm operating temperature, supply limits, conversion timing, and display-drive levels against the exact suffix ordering before production release.

This page organizes the confirmed product identity, package information, sourcing data, replacement considerations, and application guidance into an engineering-oriented reference. It also distinguishes direct suffix alternatives from functionally similar converters so that designers can focus on true footprint-compatible choices rather than broad, mechanically incompatible substitutes.

直接替换替代料: ICL7136CQH+D ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

本系列中的变体

可与以下型号直接替换的同系列型号: ICL7136CQH+D (相同外形与封装尺寸) ——差异在于 Package Type, Display Output, RoHS Status, Converter Type.

Analog Devices
Package Type: MQFP-44 (10 mm × 10 mm)
Display Output: 3.5-digit, seven-segment display driver
RoHS Status: RoHS compliant
对比 ICL7136CQH+D →
Analog Devices
Package Type: Lead chip carrier with J-leads
RoHS Status: RoHS-compliant variant indicated in comparison data
对比 ICL7136CQH+D →
Maxim Integrated
Package Type: QFP, 10 mm x 10 mm x 2 mm
Display Output: Direct LCD driver
RoHS Status: RoHS compliant
对比 ICL7136CQH+D →

ICL7136CQH+TD

✅ 直接替换
📦 PLCC-44
Same ICL7136 family and PLCC-44 format; ordering suffix differs, with both commercial temperature indications showing 0 C to +70 C

📋 参考替代料(不在目录中)

ICL7136CQH-D

✅ 直接替换
📦 PLCC-44
Same ICL7136CQH base device in PLCC-44; hyphenated commercial ordering form differs from the +D designation

📋 参考替代料(不在目录中)

ICL7137CQH

✅ 直接替换
Maxim Integrated
📦 PLCC-44
Dual-slope analog-to-digital converter · 3.5 digits · Low-power device · Direct LCD driver · QFP, 10 mm x 10 mm x 2 mm · MS-022AB · QCCJ · 44 terminals

联系询价

查看数据手册 →

ICL7136CQH+D 最大额定值与电气特性

Converter Type Dual-slope A/D converter
分辨率 3.5 digits
Architecture 1-channel, 1-function ADC
Input Configuration True differential input
Reference Configuration True differential reference
Output Format BCD, 4-bit, parallel output
Display Output Integrated LCD driver
Power Class Low-power A/D converter
Periodic Interference Rejection Automatic dual-slope rejection
Overrange Recovery Zero-integrator phase
Ratiometric Measurement Supported
Package Type 44-pin PLCC
Package Dimensions 16.59 mm x 16.59 mm
Package Code QCCJ
Terminal Form J-bend
Number of Terminals 44

ICL7136CQH+D qccj 引脚配置指南

ICL7136CQH+D(qccj 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。

ICL7136CQH+D 的 qccj 封装引脚图

暂无详细引脚数据: ICL7136CQH+D.

请参阅 数据手册 以查看完整引脚配置。

典型应用

ICL7136CQH+D 适用于 6 应用s: Digital Panel Meters, Precision Weighing Systems, Temperature and Process Monitoring, Laboratory Measurement Instruments, Portable Meter and Tester, Resistance and Bridge Test Equipment.

📺

Digital Panel Meters

The ICL7136CQH+D fits digital panel meters because it combines a 3.5-digit dual-slope conversion function with an integrated LCD driver in one 44-pin PLCC device. The converter evaluates a differential input against a differential reference, while the display outputs drive the measured value directly. This architecture can reduce the number of separate display-driver components required by standalone instrumentation. Its dual-slope conversion method also provides automatic rejection of periodic interference, which is valuable when the panel is connected to industrial sensors through long cables. The main design tradeoff is conversion speed: this is appropriate for slowly changing temperature, pressure, or process readings rather than rapidly changing waveforms.

⚖️

Precision Weighing Systems

The ICL7136CQH+D is suitable for precision weighing platforms using strain-gauge bridges because its true differential input and true differential reference support ratiometric measurement. In a bridge system, the analog signal is proportional to excitation and mechanical deflection, while the reference can track the excitation voltage. The dual-slope ADC automatically rejects periodic interference common around motors, relays, and industrial equipment, helping preserve a stable panel reading. The integrated LCD driver simplifies the display path. Designers should still verify input impedance, excitation requirements, balance, input common-mode range, and conversion timing in the manufacturer electrical tables before finalizing the bridge and analog front end.

🏭

Temperature and Process Monitoring

The ICL7136CQH+D can measure slowly changing temperature, pressure, and level signals where a stable digital indication is more important than rapid sampling. Its dual-slope conversion technique automatically rejects periodic interference, making it useful near industrial switching equipment, while the zero-integrator phase improves recovery after an overrange event. The integrated LCD driver allows a standalone panel-meter design without a separate display controller. Use the differential input and reference paths carefully because sensor-ground noise and reference leakage can affect accuracy. Confirm the device's operating temperature, input limits, supply voltage, and reference specifications before using it in an extended-range industrial enclosure.

🔧

Laboratory Measurement Instruments

The ICL7136CQH+D is appropriate for laboratory meters that display slow analog quantities with a compact panel interface. A true differential measurement path can reduce sensitivity to ground offsets in bench systems, while the reference arrangement supports calibrated and ratiometric measurements. The low-power 3.5-digit architecture avoids the need for a high-resolution flash converter when the required display resolution is 1999 counts. The integrated LCD drive outputs reduce external logic and make the device appropriate for dedicated instruments rather than general-purpose data acquisition. Key constraints are conversion latency and input bandwidth: the dual-slope architecture should be paired with signals that remain stable during the measurement cycle.

🔋

Portable Meter and Tester

The ICL7136CQH+D supports portable meters because it integrates low-power conversion and LCD drive functions in a single 44-pin PLCC package. This consolidation can reduce the number of active components compared with a separate ADC and display driver, while the dual-slope method rejects periodic interference encountered in field-service equipment. The 3.5-digit output is well matched to displays that show resistance, voltage, current, or temperature without requiring high-resolution graphical presentation. Battery-powered designs must account for the complete analog and display power budget, and the LCD should be checked for compatible segment drive, bias, and contrast requirements. Package height and thermal performance should also be reviewed for handheld enclosures.

🌐

Resistance and Bridge Test Equipment

The ICL7136CQH+D is specifically relevant to ohms and bridge-transducer measurement because the manufacturer identifies true differential input and reference as key family features. Ratiometric operation allows a displayed result to depend on the ratio between the unknown quantity and the excitation reference, which can compensate for many reference changes. This behavior is useful in resistance testers and force-sensitive bridge systems where the sensor output is small and closely tied to excitation voltage. The circuit must still satisfy the ADC input impedance, common-mode, leakage, and reference requirements. Designers should follow the manufacturer application guidance for guarding and grounding to prevent board contamination from degrading the differential measurement.

What is the ICL7136CQH+D?
The ICL7136CQH+D is a low-power, 3.5-digit, one-channel dual-slope analog-to-digital converter with an integrated LCD display driver, supplied in a 44-pin PLCC package. According to the Analog Devices ICL7136 product page, the family provides true differential input and reference arrangements, automatic rejection of periodic interference, ratiometric measurement support, and a zero-integrator phase that reduces overrange hangover and hysteresis.
Where can I download the ICL7136CQH+D datasheet?
The official ICL7136 datasheet and product documentation are available through the Analog Devices product page at https://www.analog.com/en/products/icl7136.html. The page identifies the ICL7136 as a production low-power, 3.5-digit A/D converter and provides the manufacturer Data Sheet, product models, and ordering information. Use the pin-description table and electrical-characteristics tables there before assigning signals or releasing a PCB layout.
Where can I find the ICL7136CQH+D pinout?
The ICL7136CQH+D pin assignments are found in the manufacturer datasheet associated with the Analog Devices ICL7136 product page, not in distributor search snippets. The device uses a 44-pin PLCC with J-bend terminals and a 16.59 mm by 16.59 mm body. The package-drawing library does not contain a matching PLCC-44 diagram, so use the datasheet pin-description and package drawings when defining the footprint.
What are the key specifications of ICL7136CQH+D that engineers should know?
The ICL7136CQH+D is a one-channel, 3.5-digit dual-slope ADC with BCD parallel output, true differential input and reference, an integrated LCD driver, and a 44-pin PLCC package. The Analog Devices product page identifies it as a production low-power converter designed for measurement systems. Its dual-slope architecture automatically rejects periodic interference, while true differential reference and input support improve ratiometric and bridge-based measurements.
How does the dual-slope architecture benefit ICL7136CQH+D measurements?
The dual-slope architecture improves rejection of periodic interference by measuring an unknown input relative to a reference over controlled integration intervals. According to the Analog Devices ICL7136 product page, this technique automatically rejects interference signals common in industrial environments. The trade-off is measurement speed: dual-slope conversion is generally suited to slowly changing quantities rather than high-rate waveform acquisition or fast event detection.
Can ICL7136CQH+D measure bridge transducers and resistance?
Yes, the ICL7136CQH+D is suited to ratiometric measurements involving ohms or bridge transducers because it provides true differential input and reference arrangements. In a ratiometric system, the displayed result can depend on the ratio of the measured signal to its excitation reference, helping compensate for many reference-voltage changes. The exact input and reference limits should be confirmed in the manufacturer electrical-characteristics tables.
Where can I buy ICL7136CQH+D online?
The most reliable way to source ICL7136CQH+D is through the Request a Quote form on this page. The manufacturer lists the ICL7136 family as production, and distributor listings identify the exact 44-pin PLCC device. Current unit pricing, available quantity, and production allocation can change, so submit the requested MPN and target quantity through the quote process for a current proposal.
What is the price of ICL7136CQH+D?
A current unit-price figure should be obtained through the Request a Quote form on this page. The Analog Devices product page identifies a starting list price for the ICL7136 family, but that family-level presentation is not treated as a quantity-break quotation for the exact ICL7136CQH+D order code. Submit the exact MPN, quantity, and required packaging to receive a current proposal for the specific part.
What is the lead time for ICL7136CQH+D?
The current lead time for ICL7136CQH+D should be confirmed through the Request a Quote form on this page. The Analog Devices product page identifies the ICL7136 family as production, while distributor availability can vary by exact suffix and order quantity. Provide the quantity, date code requirements, and packaging preference with the quote request to establish an actionable delivery commitment.
Is ICL7136CQH+D in stock?
ICL7136CQH+D is shown as a production family member, but current stock for the exact suffix should be checked through the Request a Quote form on this page. Listings across distribution channels do not guarantee a uniform inventory position because package, date code, and order quantity can affect allocation. Request the exact MPN and quantity to obtain the current availability status for that order.
What is the best drop-in replacement for ICL7136CQH+D?
The closest documented drop-in candidate is ICL7136CQH+TD because it is identified as the same ICL7136 converter family in a 44-pin PLCC package. The ICL7136CQH-D ordering form also appears as a direct commercial-grade designation for the same device family. ICL7137CQH uses the same PLCC-44 format but has different supply-voltage characteristics, so verify its electrical requirements before substitution.
Can ICL7136CQH+TD replace ICL7136CQH+D?
ICL7136CQH+TD is a documented same-family replacement candidate for ICL7136CQH+D because both are ICL7136 devices offered in 44-pin PLCC packages. The comparison should still confirm the exact suffix ordering, commercial temperature grade, production status, and electrical limits. Treat it as a footprint-compatible candidate rather than assuming that every ordering code has identical qualification or lifecycle terms.
Is ICL7136CQH+D the same as ICL7136CQH-D?
The ICL7136CQH+D and ICL7136CQH-D records identify the same ICL7136CQH base device in a 44-pin PLCC package, but the characters following the base ordering code can encode different commercial details. The Analog Devices product-model table is the controlling source for their exact ordering relationship. Confirm the manufacturer ordering guide before using one record as a procurement substitute for the other.
When should I choose ICL7136CQH+D over ICL7137CQH?
Choose ICL7136CQH+D when the system specifically requires the ICL7136 low-power, 3.5-digit dual-slope converter and its defined differential conversion behavior. ICL7137CQH is also listed in a 44-pin PLCC package, but the comparison identifies a different minimum operating supply voltage of 5 V versus 9 V for ICL7136CQH+TD. Select between them only after matching rail voltage, timing, display interface, and accuracy requirements.
What is the best Analog Devices equivalent for ICL7136CQH+D?
The best manufacturer-family equivalent is ICL7136CQH+TD, which is identified as an ICL7136 converter in a 44-pin PLCC package and offers the closest documented path to a board-level replacement. The alternative is not a generic modern ADC because changing conversion architecture can alter timing, noise rejection, input impedance, and display-drive behavior. Validate pin functions, supply requirements, accuracy, and LCD outputs before production substitution.

工程参考数据: ICL7136CQH+D ——对比、设计指导和合规信息。

选型指南

Choose ICL7136CQH+D for a new or existing design that requires the ICL7136's low-power, 3.5-digit dual-slope conversion, true differential input and reference, ratiometric measurement behavior, and integrated LCD drive in a 44-pin PLCC footprint. ICL7136CQH+TD is the closest same-family ordering alternative when its exact commercial suffix and current production status meet the program requirements. ICL7136CQH-D can reconcile legacy hyphenated ordering records while retaining the same base device and package. Consider ICL7137CQH only when its lower documented minimum supply and complete electrical characteristics fit the design; shared PLCC-44 construction alone is not sufficient. For designs requiring rapid conversion, high sampling rates, modern digital output, or a smaller footprint, a different ADC architecture may be more appropriate despite requiring board changes.

与替代料对比

参数 本产品 ICL7136CQH+TD ICL7136CQH-D ICL7137CQH
Package PLCC-44, 16.59 mm x 16.59 mm PLCC-44 PLCC-44 PLCC-44
Brand Analog Devices Analog Devices Analog Devices Analog Devices
ADC Architecture Dual-slope Dual-slope Dual-slope Dual-slope
Display Resolution 3.5 digits 3.5 digits 3.5 digits 3.5 digits
Number of Functions 1 function 1 function 1 function 1 function
Display Interface Integrated LCD driver Integrated LCD driver Integrated LCD driver Integrated LCD driver
Mounting Type Surface mount Surface mount Surface mount Surface mount

关键差异点

  • Closer same-family ordering alternative (对比 ICL7136CQH+TD)
  • Direct hyphenated commercial designation (对比 ICL7136CQH-D)
  • Same package and display-converter class with a lower-voltage alternative (对比 ICL7137CQH)

设计说明

Use the 44-pin PLCC footprint and pin numbering from the manufacturer package drawing rather than a generic PLCC library. Verify pad length, lead pitch, body size, and J-bend geometry against the 16.59 mm by 16.59 mm package. The supplied package library does not include a PLCC-44 key, so the PCB footprint must be checked against the official mechanical drawing before fabrication.

Do not substitute ICL7137CQH solely because both devices use PLCC-44 packages. The documented minimum operating supply differs between ICL7137CQH at 5 V and ICL7136CQH+TD at 9 V. Check rail voltage, input limits, reference limits, display-drive timing, pin behavior, and temperature grade in the respective datasheets. A shared package proves footprint compatibility only, not complete electrical equivalence.

Route the differential input and reference connections as compact, symmetric paths with minimal area between their respective conductors. Keep sensitive analog traces away from switching nodes, relay contacts, LCD drive returns, and high-current supply paths. Because the converter measures slow signals through a dual-slope cycle, maintain a stable common-mode condition and minimize leakage across high-impedance input nodes during the integration interval.

Decouple the supply rail close to the PLCC power and ground connections using the capacitance and placement specified in the manufacturer application guidance. Confirm that the selected regulator can supply the converter and LCD load without excessive ripple, and verify that display drive current does not disturb the reference and analog ground reference point. Provide adequate filtering at the LCD supply or bias connection if drive transients appear on the measured rail.

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

No exact RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals statement was identified for ICL7136CQH+D. Check the current Analog Devices product page, material declaration, and reliability documentation for the exact ordering code.

数据核验日期: 2026-11-20 ——数据由 XAIPART 元器件工程团队核验和整理

相关搜索

ICL7136CQH+D datasheet ICL7136CQH+D specifications ICL7136CQH+D pinout ICL7136CQH+D price ICL7136CQH+D stock Analog Devices ICL7136CQH+D ICL7136CQH+D replacement ICL7136CQH+D equivalent ICL7136CQH+D vs ICL7136CQH+TD ICL7136CQH+D vs ICL7137CQH ICL7136 44-PLCC ADC ICL7136CQH+D application circuit ICL7136CQH+D datasheet PDF ICL7136CQH+D footprint what can replace ICL7136CQH+D

相关元器件 & 术语

Analog Devices Maxim Integrated ICL7136CQH+D ICL7136CQH+TD ICL7136CQH-D ICL7137CQH dual-slope ADC analog-to-digital converter ADC low-power A/D converter 3.5-digit ADC BCD parallel output true differential input true differential reference ratiometric measurement integrated LCD driver zero-integrator phase periodic interference rejection 44-pin PLCC PLCC QCCJ package surface-mount package digital panel meter bridge transducer weighting system
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情