ICL7136CQH+D - 3.5-Digit Dual-Slope ADC | Analog Devices
MPN: ICL7136CQH+D ✓ Hoạt độngICL7136CQH+D Tóm tắt
A dual-slope ADC is a voltage-to-digital conversion method that integrates an unknown input over a fixed interval and compares the result with a reference. It belongs to the ADC hierarchy, performs one analog-to-digital conversion function, and provides a multi-digit BCD result intended for digital panel meters. The ICL7136 family improves this architecture with a true differential input, a true differential reference, ratiometric measurement support, and a zero-integrator phase that reduces overrange hangover and hysteresis effects.
The ICL7136CQH+D combines low-power operation with a 3.5-digit readout and integrated LCD drive circuitry. Its differential input and reference arrangement is useful for bridge transducers, resistance measurement, and other ratiometric sensors because the result can depend on the ratio between the measured quantity and the excitation reference. The automatic rejection of periodic interference helps reduce errors from common industrial noise sources. The integrated display driver reduces the need for separate logic in standalone instrumentation.
The zero-integrator phase is a significant implementation detail. Following overrange, the converter returns its integrator toward zero rather than immediately beginning another measurement with residual charge. This feature improves recovery behavior and helps avoid overrange-related hysteresis. The converter also supports dual-slope conversion, which trades conversion speed for noise rejection and is especially useful when the measured signal changes more slowly than the conversion cycle.
Typical uses include digital panel meters, laboratory measurement instruments, process monitoring, weighing systems, temperature bridges, and portable meters with LCD displays. For bridge-based sensors, ratiometric operation can compensate for many excitation-voltage variations. For applications requiring higher throughput, software-controlled switching systems, or electrical isolation, a modern sigma-delta or successive-approximation ADC may be a better architectural choice than the ICL7136CQH+D.
Use the pin-description table in the manufacturer datasheet to assign signals to all 44 PLCC leads, and confirm the required reference, input, bypass, display, and logic connections before layout release. Preserve the specified input and reference grounding strategy because differential measurements can be sensitive to common-mode voltage and leakage. Confirm operating temperature, supply limits, conversion timing, and display-drive levels against the exact suffix ordering before production release.
This page organizes the confirmed product identity, package information, sourcing data, replacement considerations, and application guidance into an engineering-oriented reference. It also distinguishes direct suffix alternatives from functionally similar converters so that designers can focus on true footprint-compatible choices rather than broad, mechanically incompatible substitutes.
Bộ thay thế dễ dàng lắp đặt cho ICL7136CQH+D — cùng gói, chân-to-chân tương thích. Các bộ phận yêu cầu hàn PCB bị loại trừ.
Các biến thể trong loạt này
Các mẫu cùng loạt có thể lắp đặt dễ dàng tương thích với ICL7136CQH+D (cùng hình factor và footprint) — khác nhau ở Package Type, Display Output, RoHS Status, Converter Type.
ICL7136CQH+TD
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
ICL7136CQH-D
✅ Drop-In📋 Tham chiếu thay thế (không có trong danh mục)
ICL7137CQH
✅ Drop-InLiên hệ để biết giá
Xem tài liệu →ICL7136CQH+D Tỷ lệ tối đa & tính chất điện
| Converter Type | Dual-slope A/D converter |
| Độ phân giải | 3.5 digits |
| Architecture | 1-channel, 1-function ADC |
| Input Configuration | True differential input |
| Reference Configuration | True differential reference |
| Output Format | BCD, 4-bit, parallel output |
| Display Output | Integrated LCD driver |
| Power Class | Low-power A/D converter |
| Periodic Interference Rejection | Automatic dual-slope rejection |
| Overrange Recovery | Zero-integrator phase |
| Ratiometric Measurement | Supported |
| Package Type | 44-pin PLCC |
| Package Dimensions | 16.59 mm x 16.59 mm |
| Package Code | QCCJ |
| Terminal Form | J-bend |
| Number of Terminals | 44 |
Hướng dẫn cấu hình chân ICL7136CQH+D qccj
Cấu hình chân cho ICL7136CQH+D (qccj gói). Thành phần số hiệu này có chân đầu vào, đầu ra và nguồn cung cấp. Tham khảo tài liệu thông số kỹ thuật của nhà sản xuất để biết cấu hình chân bù, bù trừ và chân kích hoạt. Hoàn hảo cho điều kiện tín hiệu và mạch khuếch đại.
Không có dữ liệu chân cụ thể sẵn có cho ICL7136CQH+D.
Tham khảo: tài liệu kỹ thuật cho cấu hình chân đầy đủ.
Ứng dụng tiêu biểu
ICL7136CQH+D phù hợp cho 6 Áp dụngs: Digital Panel Meters, Precision Weighing Systems, Temperature and Process Monitoring, Laboratory Measurement Instruments, Portable Meter and Tester, Resistance and Bridge Test Equipment.
Digital Panel Meters
The ICL7136CQH+D fits digital panel meters because it combines a 3.5-digit dual-slope conversion function with an integrated LCD driver in one 44-pin PLCC device. The converter evaluates a differential input against a differential reference, while the display outputs drive the measured value directly. This architecture can reduce the number of separate display-driver components required by standalone instrumentation. Its dual-slope conversion method also provides automatic rejection of periodic interference, which is valuable when the panel is connected to industrial sensors through long cables. The main design tradeoff is conversion speed: this is appropriate for slowly changing temperature, pressure, or process readings rather than rapidly changing waveforms.
Được đề xuất
Precision Weighing Systems
The ICL7136CQH+D is suitable for precision weighing platforms using strain-gauge bridges because its true differential input and true differential reference support ratiometric measurement. In a bridge system, the analog signal is proportional to excitation and mechanical deflection, while the reference can track the excitation voltage. The dual-slope ADC automatically rejects periodic interference common around motors, relays, and industrial equipment, helping preserve a stable panel reading. The integrated LCD driver simplifies the display path. Designers should still verify input impedance, excitation requirements, balance, input common-mode range, and conversion timing in the manufacturer electrical tables before finalizing the bridge and analog front end.
Được đề xuất
Temperature and Process Monitoring
The ICL7136CQH+D can measure slowly changing temperature, pressure, and level signals where a stable digital indication is more important than rapid sampling. Its dual-slope conversion technique automatically rejects periodic interference, making it useful near industrial switching equipment, while the zero-integrator phase improves recovery after an overrange event. The integrated LCD driver allows a standalone panel-meter design without a separate display controller. Use the differential input and reference paths carefully because sensor-ground noise and reference leakage can affect accuracy. Confirm the device's operating temperature, input limits, supply voltage, and reference specifications before using it in an extended-range industrial enclosure.
Được đề xuất
Laboratory Measurement Instruments
The ICL7136CQH+D is appropriate for laboratory meters that display slow analog quantities with a compact panel interface. A true differential measurement path can reduce sensitivity to ground offsets in bench systems, while the reference arrangement supports calibrated and ratiometric measurements. The low-power 3.5-digit architecture avoids the need for a high-resolution flash converter when the required display resolution is 1999 counts. The integrated LCD drive outputs reduce external logic and make the device appropriate for dedicated instruments rather than general-purpose data acquisition. Key constraints are conversion latency and input bandwidth: the dual-slope architecture should be paired with signals that remain stable during the measurement cycle.
Được đề xuất
Portable Meter and Tester
The ICL7136CQH+D supports portable meters because it integrates low-power conversion and LCD drive functions in a single 44-pin PLCC package. This consolidation can reduce the number of active components compared with a separate ADC and display driver, while the dual-slope method rejects periodic interference encountered in field-service equipment. The 3.5-digit output is well matched to displays that show resistance, voltage, current, or temperature without requiring high-resolution graphical presentation. Battery-powered designs must account for the complete analog and display power budget, and the LCD should be checked for compatible segment drive, bias, and contrast requirements. Package height and thermal performance should also be reviewed for handheld enclosures.
Được đề xuất
Resistance and Bridge Test Equipment
The ICL7136CQH+D is specifically relevant to ohms and bridge-transducer measurement because the manufacturer identifies true differential input and reference as key family features. Ratiometric operation allows a displayed result to depend on the ratio between the unknown quantity and the excitation reference, which can compensate for many reference changes. This behavior is useful in resistance testers and force-sensitive bridge systems where the sensor output is small and closely tied to excitation voltage. The circuit must still satisfy the ADC input impedance, common-mode, leakage, and reference requirements. Designers should follow the manufacturer application guidance for guarding and grounding to prevent board contamination from degrading the differential measurement.
Được đề xuất
Tóm tắt các sản phẩm được đề xuất
Dữ liệu tham khảo kỹ thuật cho ICL7136CQH+D — so sánh, hướng dẫn thiết kế và thông tin tuân thủ.
Hướng dẫn chọn lựa
So sánh với các sản phẩm thay thế
| Tham số | Sản phẩm này | ICL7136CQH+TD | ICL7136CQH-D | ICL7137CQH |
|---|---|---|---|---|
| Package | PLCC-44, 16.59 mm x 16.59 mm | PLCC-44 | PLCC-44 | PLCC-44 |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| ADC Architecture | Dual-slope | Dual-slope | Dual-slope | Dual-slope |
| Display Resolution | 3.5 digits | 3.5 digits | 3.5 digits | 3.5 digits |
| Number of Functions | 1 function | 1 function | 1 function | 1 function |
| Display Interface | Integrated LCD driver | Integrated LCD driver | Integrated LCD driver | Integrated LCD driver |
| Mounting Type | Surface mount | Surface mount | Surface mount | Surface mount |
Bảo phân biệt quan trọng
- Closer same-family ordering alternative (vsICL7136CQH+TD)
- Direct hyphenated commercial designation (vsICL7136CQH-D)
- Same package and display-converter class with a lower-voltage alternative (vsICL7137CQH)
Ghi chú thiết kế
Use the 44-pin PLCC footprint and pin numbering from the manufacturer package drawing rather than a generic PLCC library. Verify pad length, lead pitch, body size, and J-bend geometry against the 16.59 mm by 16.59 mm package. The supplied package library does not include a PLCC-44 key, so the PCB footprint must be checked against the official mechanical drawing before fabrication.
Do not substitute ICL7137CQH solely because both devices use PLCC-44 packages. The documented minimum operating supply differs between ICL7137CQH at 5 V and ICL7136CQH+TD at 9 V. Check rail voltage, input limits, reference limits, display-drive timing, pin behavior, and temperature grade in the respective datasheets. A shared package proves footprint compatibility only, not complete electrical equivalence.
Route the differential input and reference connections as compact, symmetric paths with minimal area between their respective conductors. Keep sensitive analog traces away from switching nodes, relay contacts, LCD drive returns, and high-current supply paths. Because the converter measures slow signals through a dual-slope cycle, maintain a stable common-mode condition and minimize leakage across high-impedance input nodes during the integration interval.
Decouple the supply rail close to the PLCC power and ground connections using the capacitance and placement specified in the manufacturer application guidance. Confirm that the selected regulator can supply the converter and LCD load without excessive ripple, and verify that display drive current does not disturb the reference and analog ground reference point. Provide adequate filtering at the LCD supply or bias connection if drive transients appear on the measured rail.
Thông tin tuân thủ
No exact RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals statement was identified for ICL7136CQH+D. Check the current Analog Devices product page, material declaration, and reliability documentation for the exact ordering code.