ICS501AMT - 200MHz PLL Clock Generator | Renesas Electronics
料号: ICS501AMT ✓ 量产中ICS501AMT 概述
A PLL clock generator is an integrated clock and timing circuit that locks an internal oscillator to an external reference before multiplying or conditioning that reference into a higher-frequency output. In the broader semiconductor hierarchy, the ICS501AMT belongs to the clock-generator family, within clock and timing ICs and the broader power-management and semiconductor ecosystem. Its purpose is to provide a stable, high-frequency timing reference without requiring a complete external crystal-oscillator assembly for every application.
The primary features of the ICS501AMT include a maximum output frequency of 200 MHz, one clock circuit, a 1:1 input-to-output ratio, CMOS output compatibility, and support for either a crystal or an external clock. These characteristics suit designs that need a higher-frequency clock derived from a lower-frequency source. The 3 V to 3.6 V operating range also places the device in a supply class commonly used by compact digital, communications, and embedded systems.
Technically, the ICS501AMT uses phase-locked-loop clock multiplication to establish a high-quality clock output from its reference input. The architecture is intended to replace conventional discrete crystal-oscillator arrangements in suitable electronic systems. Because the device accepts either a crystal or clock input, the design can support different reference-generation methods, although the crystal frequency, loop stability, jitter, output-waveform requirements, and load conditions must be evaluated before committing to a specific implementation.
Typical applications include digital logic clocking, communications-module timing, embedded processing, interface timing, instrumentation, and general-purpose frequency multiplication. In each case, the device acts as the clock source for circuitry requiring a CMOS-compatible reference. Its surface-mount SOIC package supports automated assembly, while the tape-and-reel configuration is intended for high-volume production and pick-and-place manufacturing.
The principal design consideration is preserving a clean reference and a controlled board environment. Route the crystal or clock input with short, symmetric traces, maintain the recommended support network, and keep sensitive timing paths away from noisy switching circuitry. Confirm output loading, rise-time limits, and downstream clock requirements against the manufacturer datasheet before layout release. The 200 MHz maximum rating is a device limit, not a guarantee that every crystal or board implementation will produce acceptable jitter at that frequency.
This product page consolidates the device architecture, operating limits, package information, sourcing guidance, and engineering trade-offs needed to evaluate the ICS501AMT. It also distinguishes verified drop-in replacements from generic clock-generator alternatives, helping designers assess PCB compatibility, supply voltage, output frequency, and timing requirements before selecting a replacement.
直接替换替代料: ICS501AMT ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
该产品暂无直接替换替代料。
请求替代料ICS501AMT 规格参数
| Device Type | 1 PLL clock generator |
| Maximum Output Frequency | 200 MHz |
| Supply Voltage Range | 3 V to 3.6 V |
| PLL | Yes |
| Input Type | Crystal or clock input |
| 输出类型 | CMOS |
| Number of Circuits | 1 clock circuit |
| Input-to-Output Ratio | 1:1 |
| Differential Input | No |
| Differential Output | No |
| 封装 | 8-SOIC, 0.154 inch wide, 3.90 mm body width |
| 安装类型 | Surface mount |
| Shipping Package | Tape and reel |
ICS501AMT tape and reel 引脚配置指南
ICS501AMT(tape and reel 封装)的引脚配置。 引脚编号、功能和连接图在制造商数据手册中定义。请参阅该手册以了解确切的封装尺寸和焊接指南。
暂无详细引脚数据: ICS501AMT.
请参阅 数据手册 以查看完整引脚配置。
典型应用
ICS501AMT 适用于 6 应用s: Digital Logic Clocking, Communications Module Timing, Embedded Processing Clock, Interface and Serializer Timing, Test and Measurement Instrumentation, Industrial Control System Timing.
Digital Logic Clocking
The ICS501AMT is appropriate for digital logic that needs a CMOS clock source capable of reaching 200 MHz from a lower-frequency crystal or reference clock. The device’s PLL architecture provides a practical way to obtain a high-frequency timing signal without implementing a complete discrete oscillator network. Place the reference network close to the input pins and route the output as a controlled transmission line when the clock reaches a high-speed domain. The engineer should confirm output jitter, edge rate, duty cycle, and fanout against the receiving logic before release.
Communications Module Timing
Communications modules often require a stable reference clock for serializers, transceivers, and digital control logic. The ICS501AMT supports crystal or clock excitation and provides a non-differential CMOS output, making it suitable for systems whose timing interface is single-ended. With a 3 V to 3.6 V operating range, it aligns with many compact communications subsystems. The critical design checks are reference accuracy, PLL jitter, output load, return loss at the operating frequency, and isolation from switching supplies and high-speed data paths.
Embedded Processing Clock
An embedded processor or programmable controller can use the ICS501AMT as a local clock source when the system requires a PLL-generated frequency above the available reference input. The 200 MHz maximum output and 1:1 input-to-output ratio make the part suitable for evaluating fixed-ratio clocking around a crystal reference. Because processor timing margins depend on edge quality and system noise, verify the target clock specification, permitted jitter, and I/O voltage before connecting the output. Keep the reference path and supply return tightly controlled.
Interface and Serializer Timing
The ICS501AMT can supply a single-ended CMOS clock to compatible serializers, parallel-to-serial converters, and interface controllers that need a locally generated timing reference. Its PLL-based organization allows a lower-frequency crystal or clock to serve as the basis for the output frequency. The layout must minimize reference-loop area and maintain controlled impedance for the high-speed output. Engineers should verify that the downstream interface accepts the generated edge rate and duty cycle and that its internal timing margin remains adequate.
Test and Measurement Instrumentation
Instrumentation systems can use the ICS501AMT as a local reference-clock generator for acquisition, conversion, and control subsystems. A single clock output simplifies distribution when the instrument does not require multiple independent frequencies. The part’s 8-SOIC footprint supports compact surface-mount assemblies, while its 3 V to 3.6 V supply range suits 3.3 V systems. For precision measurement use, evaluate phase noise, jitter, deterministic spur levels, temperature behavior, and isolation from analog and switching sections before selecting the reference topology.
Industrial Control System Timing
Industrial controllers can use the ICS501AMT when a compact board requires a high-frequency CMOS clock derived from a crystal or external reference. The surface-mount 8-SOIC package and tape-and-reel configuration support automated production, and the 200 MHz ceiling covers many modern digital control tasks. Industrial designs must account for temperature range, supply tolerance, electromagnetic interference, and long-term reliability. Confirm those limits in the Renesas manufacturer datasheet and preserve separation between clock routing and noisy power-conversion stages.
工程参考数据: ICS501AMT ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 |
|---|---|
| Brand | Renesas Electronics |
| Package | 8-SOIC, 0.154 inch wide, 3.90 mm body width |
| Device Type | PLL clock generator |
| Maximum Output Frequency | 200 MHz |
| Supply Voltage Range | 3 V to 3.6 V |
| Input Type | Crystal or clock input |
| Output Type | Non-differential CMOS |
| Number of Clock Circuits | 1 |
| Input-to-Output Ratio | 1:1 |
| Shipping Package | Tape and reel |
关键差异点
- PLL-based clock generation in a compact 8-SOIC package (对比 Conventional discrete crystal-oscillator implementation)
- Supports two reference styles (对比 Crystal-only oscillator implementation)
- Single-clock integration reduces external timing circuitry (对比 Separate oscillator plus distribution-buffer implementation)
设计说明
Keep the crystal or clock-input network and the ICS501AMT physically close together, and follow the Renesas manufacturer datasheet for crystal load capacitance and grounding. Use short, symmetric routes for the reference signal, provide a continuous ground plane, and keep the input away from switching nodes and high-current return paths. For the CMOS clock output, use a controlled-impedance route when required, avoid unnecessary stubs, and confirm downstream fanout and edge-rate limits.
Do not treat the 200 MHz maximum output rating as proof that every reference frequency will meet system timing requirements. The crystal choice, crystal load capacitance, PCB parasitics, supply noise, output loading, and reference jitter all influence real operation. Validate startup, frequency accuracy, output duty cycle, and downstream timing margin with the manufacturer’s recommended network before production release.
Decouple the 3 V to 3.6 V supply at the device using the capacitance and placement shown in the Renesas manufacturer datasheet. Keep the supply return path short and place bypass components close to the relevant power and ground pins. Avoid routing clock currents through noisy regulator outputs, and check the supply ripple at the device when the clock generator shares a board with switching converters, motor drivers, or high-current logic.
Order-code similarity does not establish drop-in compatibility. An alternative must match the 8-SOIC footprint and pin assignments, operate from the same 3 V to 3.6 V supply range, provide compatible CMOS output timing, and meet the required frequency, jitter, duty-cycle, and load conditions. Tape-and-reel packaging codes and family members with changed electrical functions should not be assumed to be interchangeable.
合规信息
The exact regulatory declarations, temperature qualification, and lead-free construction details must be confirmed from the current Renesas documentation for the ICS501AMT order code.