ISL8485IPZ - 5V 5Mbps RS-485/RS-422 Transceiver | Renesas
料号: ISL8485IPZ ✓ 量产中ISL8485IPZ 概述
An RS-485/RS-422 transceiver is an interface IC that converts logic-level signals into balanced differential line signals and receives differential signals back as logic-level outputs. RS-422 provides a point-to-point balanced communication format, while RS-485 supports multipoint bus arrangements. The ISL8485IPZ belongs to the interface-IC hierarchy within integrated circuits and is used where electrical isolation, protocol conversion, or galvanic distance is handled elsewhere in the system.
The principal operating features are a 4.5 V to 5.5 V supply range, operation to 5 Mbps, half-duplex communication, and one-unit-load RS-485 bus loading. These characteristics suit equipment that exchanges data over relatively short, high-speed balanced interconnects. The integrated transmitter and receiver reduce board area compared with separate driver and receiver circuits, while the PDIP package supports conventional through-hole assembly and prototyping.
The BiCMOS architecture combines bipolar and CMOS circuit techniques, allowing the device to provide high-speed differential signaling while maintaining low-power interface operation. Half-duplex operation means the transmitter and receiver share the same differential pair, so the design must correctly manage driver-enable and receiver-enable controls to prevent unwanted bus contention. The one-unit-load rating permits multiple compatible transceivers to share an RS-485 network, subject to the total-load and topology limits of the completed bus.
Typical uses include industrial control equipment, factory automation links, data-acquisition equipment, instrumentation, and communications modules that connect a host controller to an RS-485 or RS-422 peripheral. The 5 Mbps capability is useful for short links carrying frequent control or diagnostic messages, although cable length, topology, termination, grounding, and transceiver delay determine the practical communication distance.
Designers should place the transceiver near the connector and cable entry point, provide the required supply and bypass capacitance, and follow the manufacturer datasheet for driver-enable and receiver-enable logic. Differential pairs should be routed with consistent geometry and controlled impedance. A termination resistor is normally placed at each end of an RS-422 link; RS-485 termination practices depend on the bus topology and its signal reflections.
This page combines the exact Renesas product characteristics, package information, pricing evidence, interface-family relationships, comparison parameters, and practical implementation guidance. It also distinguishes verified drop-in alternatives from near-equivalent devices that use a different package and therefore require PCB redesign rather than simple component substitution.
直接替换替代料: ISL8485IPZ ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
ISL8490IPZ
✅ 直接替换 ⚠️ 规格未核验📋 参考替代料(不在目录中)
ISL8491IPZ
✅ 直接替换 ⚠️ 规格未核验📋 参考替代料(不在目录中)
ISL8485IPZ 规格参数
| Product Type | RS-485/RS-422 half-duplex transceiver |
| Supply Voltage Range | 4.5 V to 5.5 V |
| Nominal Supply Voltage | 5 V |
| Maximum Data Rate | 5 Mbps |
| Channel Count | 1 transmitter and 1 receiver |
| Duplex Mode | Half-duplex |
| Supported Standards | RS-485 and RS-422 |
| RS-485 Bus Load | 1 unit load |
| Process Technology | BiCMOS |
| 封装 | 8-pin PDIP |
| 安装类型 | Through-hole |
| 工作温度范围 | -40 °C to +85 °C |
| Transceiver Configuration | Single transceiver |
ISL8485IPZ 引脚配置
| 引脚 1 | RE — Receiver enable input |
| 引脚 2 | /RE — Active-low receiver enable input |
| 引脚 3 | DE — Driver enable input |
| 引脚 4 | DI — Driver data input |
| 引脚 5 | GND — Ground |
| 引脚 6 | Y — Non-inverting driver output and receiver input |
| 引脚 7 | Z — Inverting driver output and receiver input |
| 引脚 8 | VCC — Positive supply connection |
典型应用
ISL8485IPZ 适用于 6 应用s: Industrial Control Networks, Factory Automation Sensors, Data Acquisition Equipment, Building and HVAC Controllers, Instrumentation and Test Systems, Communication and Network Equipment.
Industrial Control Networks
The ISL8485IPZ fits industrial control links that carry commands and status between a controller and remote modules over an RS-485 bus. Its 4.5 V to 5.5 V operating range is compatible with regulated 5 V equipment, while the one-unit-load interface allows multiple transceivers to participate in the bus. The 5 Mbps rating supports fast update cycles on short factory links. Because the device is half-duplex, firmware and external circuitry must ensure that the driver-enable and receiver-enable states do not conflict. Long runs still require suitable cable, termination, grounding, surge protection, and a topology that preserves the intended data rate.
推荐
Factory Automation Sensors
The ISL8485IPZ can connect a programmable controller to remote sensors, actuators, and I/O modules using a balanced RS-485 network. Its one-unit-load bus presentation is useful when several compact sensor nodes must share one wiring segment. The device supports communication rates up to 5 Mbps, allowing the link to carry frequent process measurements without becoming the bottleneck for a short installation. The system designer should account for transceiver enable timing, connector placement, cable type, and protection against industrial transients. The 8-pin PDIP package also makes the device convenient for through-hole automation controller boards and prototype assemblies.
推荐
Data Acquisition Equipment
For laboratory and process data-acquisition equipment, the ISL8485IPZ provides a compact differential interface between a measurement controller and a remote acquisition module. The balanced RS-485 or RS-422 connection helps reject common-mode interference encountered near industrial equipment. Its 5 Mbps capability supports rapid transfer of sample status and configuration information, while the 4.5 V to 5.5 V supply range fits conventional 5 V analog and digital subsystems. Engineers should place the transceiver near the input/output connector, maintain a continuous differential path, and apply termination according to the selected standard and topology.
推荐
Building and HVAC Controllers
The ISL8485IPZ is appropriate for building controllers that connect room units, HVAC controllers, or field sensors through a wired RS-485 network. Its one-unit-load RS-485 characteristic supports a practical multi-node bus, while 5 Mbps operation is more than sufficient for typical supervisory control traffic. The half-duplex arrangement saves board area by sharing the differential pair, but the controller firmware must arbitrate access and manage transmit and receive enables correctly. Reliability design should include protection at externally accessible connectors and verify that cable routing avoids sources of severe electromagnetic interference.
推荐
Instrumentation and Test Systems
The ISL8485IPZ can serve as the physical communication layer in instrumentation and test systems that exchange commands with remote fixtures or measurement instruments. RS-422 is particularly useful for dedicated point-to-point cabling, while RS-485 allows several devices to share a multidrop bus. The transceiver operates up to 5 Mbps and accepts a 4.5 V to 5.5 V supply, making it appropriate for compact controller cards using regulated 5 V power. Designers should use the manufacturer timing information to define enable dead time and should validate termination, connector geometry, and cable length together to achieve reliable operation.
推荐
Communication and Network Equipment
The ISL8485IPZ is useful in communication modules that add an RS-485 or RS-422 port to an embedded controller. The integrated transmitter and receiver occupy one 8-pin PDIP package, and the 5 Mbps rate supports short high-speed links between equipment racks, peripheral modules, or service interfaces. Its one-unit-load RS-485 loading permits a designed bus to contain several compatible nodes. The implementation must preserve the differential impedance of the route, place termination only where required by the topology, and separate sensitive analog circuitry from the connector and switching-node areas.
推荐
推荐产品汇总
工程参考数据: ISL8485IPZ ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | ISL8490IPZ | ISL8491IPZ |
|---|---|---|---|
| Brand | Renesas Electronics | Renesas Electronics | Renesas Electronics |
| Package | 8-PDIP | 8-PDIP | 8-PDIP |
| Product Type | Half-duplex RS-485/RS-422 transceiver | Half-duplex RS-485/RS-422 transceiver | Half-duplex RS-485/RS-422 transceiver |
| Supply Voltage Range | 4.5 V to 5.5 V | 4.5 V to 5.5 V | 4.5 V to 5.5 V |
| Maximum Data Rate | 5 Mbps | 5 Mbps | 5 Mbps |
| Transmitter and Receiver Count | 1 TX and 1 RX | 1 TX and 1 RX | 1 TX and 1 RX |
| RS-485 Bus Load | 1 unit load | 1 unit load | 1 unit load |
| Process Technology | BiCMOS | BiCMOS | BiCMOS |
| Specialized Family Behavior | ISL8485 receiver and low-power configuration | ISL8490 family-specific receiver and low-power configuration | ISL8491 family-specific receiver and low-power configuration |
关键差异点
- Five-megabit interface capability within a single 5 V transceiver (对比 ISL8490IPZ)
- Compact integration of transmitter and receiver (对比 ISL8491IPZ)
- Single-unit-load RS-485 bus participation (对比 ISL8490IPZ)
设计说明
Route Y and Z as a closely coupled differential pair from the transceiver to the connector. Keep the path continuous and avoid splitting the pair around unrelated circuitry or changing its geometry. Place the transceiver and its local bypass capacitor near the connector-side entry point to minimize the distance over which transient energy and common-mode disturbance can propagate.
Coordinate RE, /RE, and DE so the half-duplex driver and receiver do not create bus contention. Allow a defined transition interval before changing direction, and verify the timing against the Renesas family datasheet. A logic-controlled DE signal that remains asserted during reception can overdrive the bus even when the data input is idle.
Use a regulated supply within the 4.5 V to 5.5 V operating range and place the required local bypass capacitor at the VCC and GND pins. Keep high-current switching paths and inductive loads away from the transceiver and its signal connector. Verify the supply remains within tolerance during equipment startup and line-driver transitions.
Termination must follow the selected standard and topology: an RS-422 point-to-point link normally uses termination at the receiver, while RS-485 termination depends on cable length, node placement, and reflections. Do not add termination solely to reduce apparent noise, because inappropriate resistor values or locations can reduce signal amplitude and limit the usable data rate.
合规信息
The available product and distributor information does not state specific RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status. Confirm these requirements with the manufacturer before regulatory qualification.