LM293DRE4 Dual Differential Comparator 36V | Texas Instruments
料号: LM293DRE4 ✓ 量产中LM293DRE4 概述
A comparator is an analog integrated circuit that compares two input voltages and produces a logic-level indication of their relationship. The LM293 belongs to the comparator category within analog signal-chain and power-management ICs, rather than acting as an amplifier or regulator. Two comparators in one package provide independent channels for monitoring two thresholds, controlling two loads, or implementing a window-detection function. The open-collector outputs are useful for wired logic, relay-driver interfaces, and systems requiring a pull-up resistor.
The main electrical characteristics include operation from a single supply or dual supplies, a 2 V to 36 V difference between supply rails, a common-mode input voltage range that includes ground, and low output saturation voltage. The LM293 is specified as compatible with TTL, MOS, and CMOS logic levels. The output structure can sink current from an external pull-up while providing a predictable low-level output, allowing designers to select the pull-up voltage independently of the comparator supply.
The LM293 architecture is based on two independent comparator channels rather than a shared output. This arrangement allows each channel to use separate non-inverting and inverting inputs while sharing the device supply pins. The inputs are intended for low-power threshold sensing, and the operating range supports both traditional positive-supply circuits and circuits using ground as the lower input reference. Open-collector outputs require an external pull-up when a valid high output is required.
Typical applications include industrial process-limit detection, battery and power-supply monitoring, sensor signal conditioning, overvoltage and undervoltage protection, relay or solenoid control interfaces, and window comparators. The comparator can also be used as a simple line-driver or discrete-amplifier element in low-frequency control circuits. Because the output is open collector, the pull-up resistor and load current must be selected to match the desired logic voltage and switching speed.
For PCB design, place the decoupling capacitor close to the supply and ground pins, and route comparator inputs away from switching nodes and high-current paths. The 8-SOIC footprint allows straightforward through-hole assembly and rework. The pull-up resistor should connect from each output to the logic rail used by the receiving device. Confirm the input voltages, supply current, output sink current, and common-mode limits against the application before releasing the design.
This product page combines the manufacturer’s LM293 family information, exact-MPN sourcing details, pin-level integration guidance, and drop-in replacement analysis. It is intended to help engineers move from component identification to schematic review, footprint verification, and robust analog threshold-circuit design.
直接替换替代料: LM293DRE4 ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: LM293DRE4 (相同外形与封装尺寸) ——差异在于 Package, Common-Mode Input Range, Comparator Type, Supply Configuration, Output Type.
LM293DR
✅ 直接替换联系询价
查看数据手册 →LM293DR2G
✅ 直接替换联系询价
查看数据手册 →LM293DRE4 最大额定值与电气特性
| Comparator Type | Dual differential comparator |
| Number of Comparators | 2 |
| 输出类型 | Open-collector, open-drain |
| Supply Configuration | Single supply or dual supplies |
| Maximum Tested Supply Voltage | 36 V |
| Supply Voltage Difference | 2 V to 36 V |
| Common-Mode Input Range | Includes ground |
| Supply Current Drain | 0.4 mA typical per comparator |
| Output Compatibility | TTL, MOS, and CMOS |
| Output Saturation | Low output saturation voltage |
| Industrial Temperature Grade | Industrial grade |
| 封装 | 8-SOIC, 0.154 inch (3.90 mm) width |
| 安装类型 | Surface mount |
| 引脚数 | 8 |
LM293DRE4 引脚配置
| 引脚 1 | OUT1 — Comparator 1 open-collector output |
| 引脚 2 | IN1- — Comparator 1 inverting input |
| 引脚 3 | IN1+ — Comparator 1 non-inverting input |
| 引脚 4 | GND — Ground connection |
| 引脚 5 | IN2+ — Comparator 2 non-inverting input |
| 引脚 6 | IN2- — Comparator 2 inverting input |
| 引脚 7 | OUT2 — Comparator 2 open-collector output |
| 引脚 8 | VCC — Positive supply connection |
典型应用
LM293DRE4 适用于 6 应用s: Industrial Overvoltage Protection, Battery Voltage Monitoring, Sensor Signal Conditioning, Power-Supply Window Detection, Relay and Solenoid Control, Process Line Threshold Control.
Industrial Overvoltage Protection
The LM293DRE4 is suitable for detecting when a monitored supply exceeds a configured threshold and generating a control signal for protection circuitry. Its 36 V maximum tested supply voltage and common-mode input range that includes ground make it useful for low-voltage industrial rails where the reference and sensed node remain near the lower supply boundary. The open-collector output can directly pull down a fault-enable or shutdown line when the comparator transistor is active. Connect a pull-up resistor to the logic rail, place the threshold divider close to the input pins, and keep the sensed trace away from switching nodes. This arrangement provides a simple, low-power protection stage without requiring an ADC or microcontroller for every voltage decision.
推荐
Battery Voltage Monitoring
In a battery-backed system, the LM293DRE4 can compare a divided cell or pack voltage against a fixed threshold and indicate an undervoltage condition. The common-mode range includes ground, which is valuable for single-supply battery systems, while the 0.4 mA typical drain per comparator keeps the continuous monitoring load modest. The open-collector output can trigger a load-disconnect signal or alert the system controller. Select the resistor divider for the intended cell count, include a suitable pull-up on the output, and account for comparator input offset and resistor tolerance so the switching point does not drift outside the intended battery range.
推荐
Sensor Signal Conditioning
The LM293DRE4 can convert a slowly changing sensor signal into a clean threshold event, such as a high-temperature or low-level indication. A resistor network establishes the switching reference, while the comparator’s input common-mode range including ground supports sensors whose useful signal begins near 0 V. The open-drain output is particularly useful when the next stage needs a wired-AND fault bus or a pull-up to a different logic rail. For noisy sensors, filter the input sufficiently to prevent repeated switching, and keep the comparator input route compact. The result is a simple, low-power digital edge without the complexity of an amplifier chain.
推荐
Power-Supply Window Detection
Two LM293DRE4 comparator channels can implement an upper and lower supply-window monitor. One channel checks the rail against a lower reference and the other checks it against an upper reference, allowing the system to identify undervoltage, overvoltage, or an in-range condition. The wide supply capability and ground-inclusive input range support single-rail designs, while the independent channels provide simple threshold decisions without an additional analog device. Use accurately tolerated divider resistors, define the logic state for each output, and connect suitable pull-ups to the system logic rail. This architecture is useful in power modules where a supervisor signal must remain active outside the acceptable operating range.
推荐
Relay and Solenoid Control
The LM293DRE4 can serve as the decision element in a relay-driver or solenoid-control circuit by sinking current from a transistor or driver stage when a threshold condition is met. Its open-collector output is useful with flyback-protected inductive loads because the pull-up rail can be selected independently, although the output itself should not directly exceed the device’s stated current limits. Add the required flyback diode or suppression network across the coil, ensure the driver transistor has adequate current and voltage margin, and place the comparator supply decoupling near the IC. This approach separates low-current sensing from higher-current load switching and keeps the analog decision path compact.
推荐
Process Line Threshold Control
In an industrial process-control circuit, the LM293DRE4 can compare a scaled sensor or process voltage with an adjustable reference to generate a binary limit signal. Its two independent channels allow separate high and low limits, and the common-mode range including ground simplifies circuits using 0 V as the lower boundary. The open-collector output can feed a PLC input, alarm line, or transistor-driver stage through a pull-up resistor. Maintain a defined return path for both the comparator and sensed signal, use shielding or filtering when the process node is noisy, and avoid placing long unprotected input traces beside high-current actuator wiring. This provides a rugged threshold stage with low supply consumption.
推荐
推荐产品汇总
工程参考数据: LM293DRE4 ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | LM293DR | LM293DR2G | LM293DT | LM393DR |
|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC |
| Comparator Configuration | Dual differential comparator | Dual differential comparator | Dual differential comparator | Dual differential comparator | Dual differential comparator |
| Output Type | Open-collector, open-drain | Open-collector, open-drain | Open-collector, open-drain | Open-collector, open-drain | Open-collector, open-drain |
| Supply Configuration | Single supply or dual supplies | Single supply or dual supplies | Single supply or dual supplies | Single supply or dual supplies | Single supply or dual supplies |
关键差异点
- Exact LM293 family positioning (对比 LM393DR)
- Two independent threshold channels (对比 LM2901N/PB)
- Ground-inclusive common-mode operation (对比 LM293DT)
设计说明
Place the supply bypass capacitor immediately between pin 8 and pin 4, with a short ground return. Route the two comparator input networks away from relay, power-converter, and motor-switching nodes. Input traces are high impedance and can pick up switching noise even when the comparator itself has a wide supply range.
Do not treat the open-collector output as a push-pull logic output. Add a pull-up resistor to each output and ensure its voltage does not exceed the output-pin rating. Also avoid driving the comparator input beyond its common-mode range, particularly when the input divider exceeds the supply rail during fault conditions.
For slowly changing sensor signals, add hysteresis with positive feedback so noise near the threshold does not cause repeated output transitions. Keep the feedback resistor connection short and separate it from high-current output pull-ups. Recalculate the switching point with both the divider resistors and the feedback effect included.
Use a common ground reference for the comparator supply, divider network, and pull-up load. If the open-collector output switches a remote or inductive load, route the higher-current transient path away from the input pins and use appropriate suppression on the load. The logic pull-up should be close enough to the output to minimize loop area.
合规信息