SN65HVD70DGSR vs SN65HVD76D Vergleich
Detaillierter Direktvergleich von SN65HVD70DGSR von Texas Instruments und SN65HVD76D von Texas Instruments. Vergleichen Sie die wichtigsten Spezifikationen, elektrischen Parameter, Gehäuse, Lebenszyklusstatus, Preise und Verfügbarkeit, um das beste Bauteil für Ihre Designanforderungen zu ermitteln.
Texas Instruments
SN65HVD70DGSR - 3.3V Full-Duplex RS-485 400kbps Transceiver, 10-VSSOP | Texas Instruments
SN65HVD70DGSR ✓ AktivSpezifikationsvergleich
| Parameter | SN65HVD70DGSR | SN65HVD76D |
|---|---|---|
| Marke | Texas Instruments | Texas Instruments |
| Kategorie | Interface ICs | Interface ICs |
| Lebenszyklusstatus | Aktiv | Aktiv |
| Product Type | RS-485 / RS-422 Transceiver | Full-duplex RS-485 transceiver |
| Protocol | RS-422, RS-485 | — |
| Number of Drivers/Receivers | 1/1 | 1/1 |
| Duplex | Full | — |
| Supply Voltage (VCC) | 3.0 V to 3.6 V | — |
| Datenrate | Up to 400 kbps | — |
| IEC ESD Protection (Contact) | ±12 kV (IEC 61000-4-2) | — |
| HBM ESD Protection (Bus pins) | ±30 kV (HBM) | — |
| Receiver Hysteresis | 50 mV (typical) | 70 mV |
| Common-Mode Range | -7 V to +12 V | — |
| Unit Load | 1/8 unit load (up to 256 nodes) | — |
| Driver Enable | Active-high | Active high |
| Receiver Enable | Active-low | Active low |
| Standby Current | < 5 µA (both disabled) | — |
| Betriebstemperatur | -40 °C to +125 °C | — |
| Gehäuse | 10-pin VSSOP (DGS) with PowerPAD | 14-pin SOIC (D) |
| Montageart | Surface Mount | Surface mount |
| RoHS-Status | Compliant | [DATA_NEEDED: RoHS status] |
| Versorgungsspannung | — | 3.3 V |
| Supply Voltage Range | — | 3 V to 3.6 V |
| Maximum Data Rate | — | 50 Mbps |
| Duplex Mode | — | Full-duplex |
| Supported Protocols | — | RS-485 and RS-422 |
| Receiver Unit Load | — | 1/8 unit load |
| Maximum Bus Nodes | — | 256 nodes |
| IEC Contact Discharge Protection | — | Greater than 12 kV |
| Human Body Model Protection | — | Greater than 30 kV |
| IEC Fast Transient Burst Protection | — | Greater than 4 kV |
| Low Standby Current | — | Less than 5 uA with driver and receiver disabled |
| Betriebstemperaturbereich | — | -40 C to 125 C |