LT1168IS8 - Low-Power Precision Instrumentation Amplifier | Analog Devices
N.º de pieza: LT1168IS8 ✓ ActivoLT1168IS8 Descripción general
An instrumentation amplifier is a differential-input amplifier optimized for measuring small signals superimposed on larger common-mode voltages. Its internal difference amplifier rejects common-mode noise, while the LT1168 adds internal gain-setting resistors so one external resistor can establish gains up to 10,000. This position in the signal-chain hierarchy—sensor input, differential amplification, then conversion—makes the device useful for bridge transducers, biomedical sensing, and precision current measurement.
The LT1168 combines low-voltage noise of 10 nV/√Hz at 1 kHz with low typical power consumption. Its single-resistor gain programming simplifies board layouts that would otherwise require several precision resistors and an op-amp network. The manufacturer also identifies the LT1168 as a pin-for-pin improved second source for the AD620 and INA118, providing an additional sourcing option for compatible instrumentation-amplifier designs.
The 8-pin SOIC package supports conventional surface-mount assembly and exposes supply, input, output, reference, and gain-resistor connections. With two external 5 kΩ resistors, the LT1168 passes the IEC 1000-4-2 level 4 specification identified by the manufacturer. This ESD capability is relevant when the amplifier is placed near sensors, connectors, or other accessible circuit nodes.
Typical uses include low-level bridge excitation and readout, biomedical instrumentation, battery-powered measurement systems, precision current sensing, and industrial sensor interfaces. The wide ±2.3 V to ±18 V supply range supports both low-voltage portable equipment and higher-voltage industrial systems, subject to the absolute maximum ratings in the manufacturer datasheet.
Designers should use the gain-resistor connection as specified in the manufacturer datasheet and keep the gain-setting component close to the relevant device pins to minimize added noise and parasitic capacitance. Input and reference networks should be laid out away from switching nodes, and supply bypassing should follow the datasheet's recommended application circuit to preserve low-noise operation.
This page combines the manufacturer's electrical and application guidance with drop-in replacement analysis, focused design notes, and parameter comparisons. It is intended to help engineers select the LT1168IS8 for precision low-noise instrumentation while accounting for package compatibility, gain range, supply limits, and system-level noise performance.
Alternativas directas para LT1168IS8 — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.
Variantes de esta serie
Modelos de la misma serie compatibles directamente con LT1168IS8 (mismo factor de forma y huella) — difiere en Package, Amplifier Type, Gain Range, Number of Circuits, RoHS Status.
AD620ARZ
✅ Sustitución directaConsulte el precio
Ver hoja de datos →INA118U/2K5
✅ Sustitución directaConsulte el precio
Ver hoja de datos →LT1168CS8#PBF
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
LT1168AIS8#PBF
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
LT1168IS8 Valores máximos y características eléctricas
| Amplifier Type | Single-resistor gain-programmable precision instrumentation amplifier |
| Number of Circuits | 1 circuit |
| Gain Range | 1 to 10,000 |
| Input Voltage Noise | 10 nV/√Hz at 1 kHz |
| Typical Supply Current | 350 µA at ±15 V |
| Supply Voltage Range | ±2.3 V to ±18 V |
| Encapsulado | 8-pin SOIC |
| Número de pines | 8 pins |
| Tipo de montaje | Surface mount |
| Temperature Grade | Industrial |
| ESD Protection | IEC 1000-4-2 level 4 with two external 5 kΩ resistors |
| Slew Rate | 0.5 V/µs |
| Gain Resistors Required | 1 external resistor |
| Reference Connection | 1 pin |
| Estado RoHS | unknown |
| REACH Status | unknown |
Configuración de pines de LT1168IS8
| Pin 1 | RG — Gain-setting resistor connection |
| Pin 2 | -IN — Inverting differential input |
| Pin 3 | +IN — Non-inverting differential input |
| Pin 4 | V- — Negative supply connection |
| Pin 5 | REF — Reference input for output offset |
| Pin 6 | OUT — Analog output |
| Pin 7 | V+ — Positive supply connection |
| Pin 8 | RG — Gain-setting resistor connection |
Aplicaciones típicas
LT1168IS8 es adecuado para 6 aplicacións: Precision Bridge Sensor Interface, Battery-Powered Biomedical Sensing, Precision Current Shunt Measurement, Industrial Pressure and Strain Monitoring, Low-Level DC Signal Conditioning, Low-Voltage Sensor Acquisition.
Precision Bridge Sensor Interface
The LT1168IS8 fits precision bridge measurements because its differential instrumentation-amplifier architecture attenuates common-mode voltage while amplifying the small bridge imbalance. One external resistor establishes gains from 1 to 10,000, simplifying the gain network around strain, pressure, and load cells. Its 10 nV/√Hz input noise at 1 kHz limits input-referred noise, although the selected gain also multiplies resistor and reference-network noise. The ±2.3 V to ±18 V supply range supports both portable bridges and higher-voltage industrial installations. Confirm the bridge excitation level, common-mode operating range, signal bandwidth, and allowable input imbalance before finalizing the gain and output scaling.
Recomendado
Battery-Powered Biomedical Sensing
The LT1168IS8 is appropriate for low-power biomedical signal conditioning where sensor outputs are small, differential, and referenced to a large common-mode voltage. Its 350 µA typical supply current at ±15 V reduces amplifier overhead in portable systems, while 10 nV/√Hz input noise at 1 kHz supports high-gain measurement of biopotential and physiological sensor signals. Single-resistor gain programming also reduces the component count compared with discrete resistor networks. For battery operation, recalculate current using the actual supply voltage because the 350 µA figure is specified at ±15 V. Confirm electrode protection, input bias-current requirements, leakage, isolation, and medical qualification separately; the device's electrical suitability does not establish system-level medical compliance.
Recomendado
Precision Current Shunt Measurement
The LT1168IS8 can amplify the differential voltage produced by a current shunt without requiring the amplifier input to tolerate the full high-side common-mode voltage. Its single-resistor gain programming supports a broad range of measurement spans, from 1 to 10,000, and its low 10 nV/√Hz input noise at 1 kHz improves resolution for small shunt drops. The 8-pin SOIC package permits compact placement close to the shunt and feedback loop. Care is needed because Kelvin routing must avoid copper voltage drops, and the amplifier's input and output limits must be checked at maximum current and fault conditions. Gain error, offset, bandwidth, and shunt power dissipation should be validated together in the final measurement chain.
Recomendado
Industrial Pressure and Strain Monitoring
The LT1168IS8 suits industrial pressure and strain monitoring systems where long sensor cables can introduce common-mode interference and ground differences. Differential amplification rejects much of that common-mode signal, while the programmable gain of 1 to 10,000 lets one amplifier family cover different mechanical sensitivities. The low-noise rating of 10 nV/√Hz at 1 kHz helps preserve resolution when the bridge output is small. Place the amplifier near the sensor connector when possible, use guarded or differential routing, and isolate switching converters and motor power stages from the input path. Also verify input and output common-mode limits, electrical surge requirements, calibration method, and temperature stability over the operating environment.
Recomendado
Low-Level DC Signal Conditioning
The LT1168IS8 is useful when a low-level differential DC signal must be conditioned before ADC acquisition. A gain of 1 to 10,000 provides enough scaling to improve the converter's effective input resolution, while the instrumentation topology limits common-mode pickup from cables and nearby digital circuitry. The 10 nV/√Hz input noise at 1 kHz is valuable when large gain is used, and the ±2.3 V to ±18 V supply span permits operation from low-voltage analog rails. Establish the required output range relative to the ADC input span before selecting the gain. Include offset, gain error, bias current, reference noise, and settling time in the error budget, and use the REF connection appropriately if output offset adjustment is needed.
Recomendado
Low-Voltage Sensor Acquisition
The LT1168IS8 supports compact, low-voltage sensor acquisition systems because it operates from ±2.3 V to ±18 V and consumes 350 µA typically at ±15 V. A wide gain range accommodates outputs from resistive dividers, strain bridges, and current shunts without requiring a separate programmable-gain stage. Its low-voltage noise makes the device useful for compact industrial, IoT, and portable instrumentation, although actual supply current at low voltage must be checked from the datasheet characterization curves. Decoupling capacitors should be placed close to the supply pins, and sensitive input and gain-resistor tracks should remain away from switching nodes. Validate input bias-current error, common-mode range, and ADC acquisition requirements in the completed board.
Recomendado
Resumen de productos recomendados
Datos de referencia de ingeniería para LT1168IS8 — comparación, orientación de diseño e información de cumplimiento.
Guía de selección
Comparación con alternativas
| Parámetro | Este producto | AD620 | INA118 | LT1168CS8#PBF | LT1168AIS8#PBF |
|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Texas Instruments | Analog Devices | Analog Devices |
| Package | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC | 8-pin SOIC |
| Amplifier Type | Precision instrumentation amplifier | Precision instrumentation amplifier | Precision instrumentation amplifier | Precision instrumentation amplifier | Precision instrumentation amplifier |
Diferenciadores clave
- Single-resistor gain programming with a broad 1-to-10,000 range (frente a AD620)
- Low input noise retained with low typical supply current (frente a INA118)
- Manufacturer-identified pin-for-pin second-source relationship (frente a AD620)
- Configurable temperature-grade sourcing within the LT1168 family (frente a LT1168CS8#PBF)
Notas de diseño
Place the gain-setting resistor close to the RG connections and route the input pair as a short, symmetric pair to minimize parasitic capacitance and loop area. Keep the differential inputs away from switching nodes, inductors, and high-current return paths. The input-reference combination is sensitive to leakage and imbalance, so use guarded grounding where practical and avoid conductive contamination near the input pins.
Use the supply-bypassing arrangement shown in the manufacturer's application guidance and place capacitors directly between the supply pins and their corresponding ground return. Check input common-mode voltage and output swing against the selected ±2.3 V to ±18 V supply range. The 350 µA typical current is specified at ±15 V, so recalculate low-voltage supply consumption from the datasheet characterization data before estimating battery life.
A gain of 10,000 amplifies input-referred offset, bias-current error, resistor noise, and coupled interference as well as the intended signal. Establish an end-to-end error budget at the required temperature range, and avoid using more gain than the sensor output requires. When working near the bandwidth limit, verify settling behavior and slew-rate requirements; the listed 0.5 V/µs slew rate is important for large-signal steps.
Do not treat a matching 8-pin package as sufficient proof of interchangeability. Compare the complete pin functions, gain equation, common-mode range, input and output swing, offset, gain error, bias current, bandwidth, noise, slew rate, and ESD requirements. The REF pin must also be connected according to the manufacturer circuit for the intended output-bias arrangement; otherwise, offset behavior may not match the original design.
Información de cumplimiento
The manufacturer identifies IEC 1000-4-2 level 4 ESD performance when two external 5 kΩ resistors are used. RoHS, REACH, lead-free, halogen-free, and conflict-minerals status are not established by the listed manufacturer and distributor pages.