MPXV5010GC6U - 10kPa Vented Gauge Pressure Sensor | NXP
Référence : MPXV5010GC6U ✓ Actif| Qté | Prix unitaire | Total |
|---|---|---|
| 1 | $14.5 | $14,50 |
| 10 | $12.95 | $129,50 |
| 100 | $10.85 | $1 085,00 |
| 500 | $9.4 | $4 700,00 |
| 1 000 | $8.2 | $8 200,00 |
MPXV5010GC6U Présentation
A pressure sensor is a transducer that converts an applied pressure into a measurable electrical signal; piezoresistive sensors use diffused strain gauges on a silicon diaphragm whose resistance changes with mechanical strain. The MPXV5010GC6U combines micromachined silicon, thin-film metallization, and bipolar signal conditioning to provide a temperature-compensated, calibrated, high-level analog output that interfaces directly to an MCU/MPU A/D input without external amplification.
Key features include on-chip signal conditioning and temperature compensation, a high-level 0.2 V to 4.7 V ratiometric output that aligns with a 5 V ADC full-scale, a vented-gauge reference that compensates for ambient barometric pressure, and a top-port male tube inlet sized at 0.13 inch (3.17 mm) for hose or barb connections. The integrated design eliminates external compensation components, simplifying BOM and PCB area.
Architecturally the device uses a diffused piezoresistive bridge on a micromachined silicon diaphragm; the bridge is excited by the supply and the differential output is amplified and offset by on-chip bipolar circuitry to produce a near-ground-referenced, rail-ratiometric transfer function. This architecture delivers factory-calibrated accuracy over the specified pressure range without user trimming.
Typical applications include medical respiratory monitoring (spirometers, ventilators), HVAC variable-air-volume (VAV) controls, gas flow sensing, industrial process monitoring, and consumer airflow measurement. The wide 0 to 10 kPa range with 1.45 PSI full-scale suits both human-breath pressure monitoring and low-pressure industrial gas lines.
When designing with this part, observe the 4.75 V to 5.25 V supply window to preserve ratiometric output accuracy, place a 100 nF decoupling capacitor close to the supply pin, and account for the vented-gauge reference in altitude-sensitive applications. The tube inlet orientation (top port) constrains PCB placement relative to the air path.
This page synthesizes distributor pricing, drop-in alternative cross-references from the MPXV5 family, and practical design notes that are not collected in the manufacturer datasheet alone.
Alternatives de remplacement direct pour MPXV5010GC6U — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec MPXV5010GC6U (même facteur de forme et même empreinte) — différant par Package, Accuracy, Output Type, Supply Voltage, Operating Pressure Range.
Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :
MPXV5010GC6T1
✅ Remplacement direct✓ En stock
$6.85 / unité
Voir la fiche technique →MPXV5010GC7U
✅ Remplacement direct✓ En stock
$10.05 / unité
Voir la fiche technique →MPXV5010GWSU
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
MPXV5010DP
✅ Remplacement direct✓ En stock
$8.1 / unité
Voir la fiche technique →MPXV5050GC6U
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
MPXV5004GC7U
✅ Remplacement direct✓ En stock
$7.1 / unité
Voir la fiche technique →MPXV5010GC6U Valeurs maximales et caractéristiques électriques
| Type de capteur | Pressure Sensor, Vented Gauge |
| Pressure Range | 0 kPa to 10 kPa (0 to 1.45 PSI) |
| Type de sortie | Analog, Ratiometric |
| Plage de tension de sortie | 0.2 V to 4.7 V |
| Tension d'alimentation | 4.75 V to 5.25 V (5 V typical) |
| Port Style | Top port, male 0.13 inch (3.17 mm) tube |
| Boîtier | 8-pin SOP (Small Outline Package), SMD Gull Wing |
| Accuracy | Factory-calibrated (see datasheet for total error band) |
| Temperature Compensation | On-chip |
| Signal Conditioning | On-chip, amplified and offset |
| Technology | Piezoresistive, monolithic silicon |
| Type de montage | Surface Mount |
| Statut RoHS | Compliant |
| Series | MPXV5010G (MPX5010 family) |
Configuration des broches de MPXV5010GC6U
| Broche 1 | VDD — Positive supply input (5 V nominal) |
| Broche 2 | GND — Ground reference |
| Broche 3 | VOUT — Analog ratiometric output, 0.2 V to 4.7 V |
| Broche 4 | NC — Not connected (per datasheet) |
| Broche 5 | NC — Not connected (per datasheet) |
| Broche 6 | NC — Not connected (per datasheet) |
| Broche 7 | NC — Not connected (per datasheet) |
| Broche 8 | NC — Not connected (per datasheet) |
Applications typiques
MPXV5010GC6U convient pour 6 applications: Medical Respiratory Monitoring, HVAC Variable-Air-Volume (VAV) Control, Gas Flow Sensing, Industrial Process Monitoring, Consumer Airflow and Air-Quality Devices, Pneumatic Leak Test Fixtures.
Medical Respiratory Monitoring
The MPXV5010GC6U's 0 to 10 kPa range and on-chip temperature compensation make it a strong fit for spirometers, ventilators, and CPAP airflow channels where breath pressure spans roughly -1 to +10 kPa. Its ratiometric 0.2 V to 4.7 V output on a 5 V rail couples directly to a medical-grade MCU ADC without instrumentation amplifiers, reducing BOM and leak paths. The vented-gauge reference rejects ambient barometric drift so readings stay consistent across altitude and weather.
Recommandé
HVAC Variable-Air-Volume (VAV) Control
Building automation ducts typically run at static pressures from 0 to 10 kPa, exactly the range of the MPXV5010GC6U. Its top-port tube inlet accepts standard 3.17 mm hose barbs used in VAV boxes, and the calibrated analog output feeds the damper controller ADC without gain stages. The on-chip temperature compensation keeps accuracy across supply-air temperature swings common in rooftop AHUs.
Recommandé
Gas Flow Sensing
Differential pressure across an orifice or laminar flow element is the standard method for infering gas flow, and the 0 to 10 kPa window covers most low-flow medical and industrial gas lines. The MPXV5010GC6U provides a calibrated, ratiometric output that pairs with a differential pair or a single-ended reference for flow calculation. NXP's MPXV5010GC6 product page positions this part family for gas flow instrumentation specifically.
Recommandé
Industrial Process Monitoring
Low-pressure process lines such as cleanroom underpressure, vacuum-pump backing lines, and pneumatic leak-test fixtures sit comfortably within 0 to 10 kPa. The MPXV5010GC6U's SOP-8 surface-mount package supports high-density instrumentation boards, while its calibrated output eliminates the per-unit trim step typical of bare piezoresistive bridges. On-chip temperature compensation keeps readings stable across process-side temperature excursions.
Recommandé
Consumer Airflow and Air-Quality Devices
Smart-home air-quality monitors, range-hood airflow sensors, and HVAC zone controllers need a compact, low-cost pressure element that runs from a 5 V rail. The MPXV5010GC6U integrates signal conditioning and temperature compensation, eliminating the analog front-end that would otherwise inflate BOM and PCB area. The ratiometric output simplifies ratiometric ADC reads, improving effective resolution.
Recommandé
Pneumatic Leak Test Fixtures
Leak-test fixtures pressurize a sealed assembly and watch for decay; the 0 to 10 kPa range of the MPXV5010GC6U covers most consumer and industrial leak-test envelopes. Its vented-gauge reference subtracts ambient pressure so the test reading reflects only the fixture's internal pressure. The factory-calibrated accuracy avoids per-fixture gain trim and supports multi-channel test heads.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour MPXV5010GC6U — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | MPXV5010GC6T1 | MPXV5010GC7U | MPXV5010GWSU | MPXV5010DP | MPXV5050GC6U |
|---|---|---|---|---|---|---|
| Brand | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors |
| Package | SOP-8 (top port) | SOP-8 (top port) - same | SOP-8 (top port) - same | SOP-8 (top port) - same | SOP-8 (dual port) - same family | SOP-8 (top port) - same |
| Pressure Range | 0 to 10 kPa (0 to 1.45 PSI) | 0 to 10 kPa | 0 to 10 kPa | 0 to 10 kPa | 0 to 10 kPa | 0 to 50 kPa |
| Output Voltage Range | 0.2 V to 4.7 V | 0.2 V to 4.7 V | 0.2 V to 4.7 V | 0.2 V to 4.7 V | 0.2 V to 4.7 V | 0.2 V to 4.7 V (rescaled) |
| Supply Voltage | 4.75 V to 5.25 V | 4.75 V to 5.25 V | 4.75 V to 5.25 V | 4.75 V to 5.25 V | 4.75 V to 5.25 V | 4.75 V to 5.25 V |
| Port Style | Top port, male 0.13 inch tube | Top port | Top port | Top port | Dual port | Top port |
| Mounting Type | Surface Mount | Surface Mount | Surface Mount | Surface Mount | Surface Mount | Surface Mount |
| Calibration | Factory-calibrated | Factory-calibrated | Factory-calibrated | Factory-calibrated | Factory-calibrated | Factory-calibrated (different range) |
Principaux différenciateurs
- On-chip temperature compensation and signal conditioning (vs MPXV5050GC6U)
- Factory-calibrated ratiometric output (vs MPXV5004GC7U)
- Single 5 V supply, no external amplifier (vs MPX5010GS)
Notes de conception
Operate the MPXV5010GC6U strictly within 4.75 V to 5.25 V to preserve ratiometric accuracy; the 0.2 V to 4.7 V output scales with VDD, so a 4.85 V supply shifts the full-scale output down proportionally. Place a 100 nF X7R ceramic decoupling capacitor within 2 mm of pin 1 (VDD) and a 10 uF bulk capacitor on the supply rail to suppress noise that would otherwise couple into the analog output.
The top-port tube inlet occupies the top face of the SOP-8 body and requires PCB keep-out above the sensor for hose or barb mating; orient the long axis of the package away from tall components. Avoid routing digital traces beneath the sensor body, as the vented-gauge reference port is on the underside and digital switching noise can couple through the silicon die.
Route the analog output trace as a guarded microstrip with a continuous ground plane on either side, keep the trace under 50 mm, and add a small RC low-pass filter (10 kohm + 100 nF) close to the ADC input if the MCU is shared with switching power or digital I/O. The factory calibration assumes a high-impedance ADC input, so verify the ADC sample-and-hold settling time is well below 1 ms.
Do not pot, conformal-coat, or pot the top-port inlet; clogging or sealing the tube inlet will cause drift or failure. Avoid silicone-based conformal coatings that outgas and contaminate the inlet. For washable assemblies, use a Parylene coating compatible with piezoresistive sensors per NXP's application notes.
Informations de conformité