INA326EA/250 - 1kHz Precision Instrumentation Amplifier | TI
MPN: INA326EA/250 ✓ פעילINA326EA/250 סקירה
An instrumentation amplifier is a specialized analog amplifier optimized for measuring small differential signals while rejecting common-mode interference. Its internal architecture provides gain, differential sensing, and input common-mode rejection in one device. Within the broader hierarchy, an instrumentation amplifier is an amplifier IC and a precision signal-conditioning component used ahead of converters, sensors, and data-acquisition systems. The INA326 family is designed for systems requiring low drift, low noise, and rail-to-rail signal-chain flexibility.
Key characteristics include one amplifier channel, a 0.1 V/V to 1000 V/V programmable gain range, rail-to-rail inputs and outputs, a 2.7 V to 5.5 V supply range, and operation from -40 °C to 85 °C. The combination of 100 µV maximum input offset and 33 nV/√Hz typical noise supports accurate extraction of low-level differential signals. The 1 kHz gain-bandwidth characteristic makes the device suitable for precision rather than high-speed signal acquisition.
The INA326EA/250 uses a CMOS implementation to combine low input bias current, low offset voltage, and low drift with rail-to-rail input and output behavior. Because its output can approach the supply rails, downstream circuitry can use a wide portion of the available analog voltage range. Its programmable gain allows one device family to serve applications ranging from modest differential amplification to high-gain sensor conditioning while preserving the same 8-pin footprint.
Typical uses include bridge and strain-gauge signal conditioning, low-level current measurement, precision sensor interfaces, medical instrumentation, industrial process measurement, and data-acquisition front ends. The device is particularly appropriate when the target signal is differential, the common-mode environment is demanding, and measurement accuracy matters more than wideband throughput. A suitable analog-to-digital converter can then digitize the conditioned output.
A key design consideration is to preserve the differential nature of the input signal. Keep input routing compact, use symmetric interconnections where practical, and place the gain-setting resistor close to the RG pin. Follow the Texas Instruments datasheet pin-description table when assigning PCB tracks, and confirm that the selected gain, supply voltage, and output-swing requirements remain compatible with the intended sensor.
This page consolidates the Texas Instruments product characteristics, ordering information, package details, technical comparisons, and application guidance for engineers evaluating the INA326EA/250. It also organizes drop-in ordering options, practical design considerations, and search-focused technical information into one engineering reference.
חלופות תחליף ישיר עבור INA326EA/250 — אותו מארז, תואם פין-לפין. חלקים במארז שונה הדורשים עיבוד מחדש של ה-PCB אינם נכללים.
INA326EA/250G4
✅ Drop-In📋 חלופה להתייחסות (לא בקטלוג)
INA326EA/250 דירוגים מרביים ומאפיינים חשמליים
| Product Type | Precision CMOS instrumentation amplifier, 1 amplifier channel |
| Supply Voltage Range | 2.7 V to 5.5 V |
| Gain Bandwidth | 1 kHz |
| Typical Gain Bandwidth | 114 dB at 1 kHz |
| Maximum Input Offset Voltage | 100 µV |
| Input Noise Density | 33 nV/√Hz typical at 1 kHz |
| Programmable Gain Range | 0.1 V/V to 1000 V/V |
| Input Common-Mode Capability | Rail-to-rail |
| Output Swing Capability | Rail-to-rail |
| Number of Channels | 1 channel |
| Technology | CMOS |
| טווח טמפרטורת פעולה | -40 °C to +85 °C |
| מארז | 8-pin VSSOP (DGK) |
| סוג הרכבה | Surface mount |
| סטטוס RoHS | Compliant |
מדריך תצורת פינים של INA326EA/250 8-pin vssop (dgk)
תצורת פינים עבור INA326EA/250 (מארזת 8-pin vssop (dgk)). רכיב אנלוגי זה כולל פיני כניסה, יציאה ואספקת מתח. יש לעיין בגיליון הנתונים של היצרן לתצורות פיני איפוס היסט, פיצוי והפעלה. אידיאלי למעגלי עיצוב אותות ומגברים.
אין נתוני פריסת פינים מפורטים עבור INA326EA/250.
עיינו ב- גיליון נתונים עבור תצורת פינים מלאה.
יישומים טיפוסיים
INA326EA/250 מתאים עבור 6 יישוםs: Strain-Gauge and Bridge Sensor Conditioning, Precision Current Measurement, Medical and Diagnostic Instrumentation, Industrial Process Measurement, Data-Acquisition Front Ends, Portable Sensor and IoT Interfaces.
Strain-Gauge and Bridge Sensor Conditioning
The INA326EA/250 fits low-level bridge measurements where differential excitation produces a small output around a substantial common-mode voltage. Its rail-to-rail input operation, 100 µV maximum input offset voltage, and programmable gain from 0.1 V/V to 1000 V/V help preserve accuracy while amplifying the bridge imbalance. The device is normally placed between the bridge and an ADC, with the gain-setting resistor connected according to the manufacturer configuration. Keep bridge excitation and sense paths short and symmetrical to reduce pickup and imbalance error.
מומלץ
Precision Current Measurement
The INA326EA/250 can amplify the voltage generated by a current shunt or current-transformer secondary when the signal is differential and low amplitude. Its 33 nV/√Hz typical input noise and low offset support measurements where the useful signal is close to the amplifier noise and offset limits. Because it is a precision, 1 kHz-bandwidth device rather than a wideband amplifier, the application benefits most when the measured current changes slowly enough for accurate settling and filtering.
מומלץ
Medical and Diagnostic Instrumentation
The INA326EA/250 is appropriate for biomedical front ends that measure small differential sensor signals while rejecting interference from the surrounding environment. Rail-to-rail input and output capability provides useful signal range from a 2.7 V to 5.5 V supply, while the 100 µV maximum offset supports a low baseline error. For patient-connected or diagnostic equipment, engineers must also evaluate isolation, protection, leakage, safety, and applicable medical requirements separately from the amplifier's performance ratings.
מומלץ
Industrial Process Measurement
The INA326EA/250 supports low-level industrial sensor interfaces where a transducer produces a differential voltage and the controller requires accurate amplification before conversion. Its precision CMOS architecture, low-drift positioning, rail-to-rail I/O, and programmable gain suit pressure, temperature, and process-control signals. The 1 kHz gain-bandwidth characteristic limits high-speed transient capture, so the interface should include suitable filtering and ensure that amplifier settling meets the control-loop timing requirements.
מומלץ
Data-Acquisition Front Ends
The INA326EA/250 can serve as the analog gain stage immediately before an ADC in a precision data-acquisition channel. A gain of 0.1 V/V to 1000 V/V allows the same amplifier family to handle signals of different amplitudes, while the 114 dB typical gain bandwidth at 1 kHz supports accurate low-frequency measurements. Use close input routing, a compact gain resistor, and appropriate anti-alias filtering. The ADC selection should match the amplifier's output swing, bandwidth, noise, and conversion requirements.
מומלץ
Portable Sensor and IoT Interfaces
The INA326EA/250 is suitable for battery-powered sensor nodes when the sensor output is small and differential and the system operates from a low-voltage rail. Its supply range begins at 2.7 V, and rail-to-rail input and output behavior can improve utilization of the available voltage in compact designs. The precision nature of the amplifier makes it useful for environmental, wearable, and condition-monitoring nodes. Designers should account for supply noise, sensor excitation, ADC conversion time, and the amplifier's own current consumption when calculating battery life.
מומלץ
סיכום מוצרים מומלצים
נתוני עזר הנדסיים עבור INA326EA/250 — השוואה, הנחיות תכנון ומידע על תאימות.
מדריך בחירה
השוואה עם חלופות
| פרמטר | מוצר זה | INA326EA/250G4 |
|---|---|---|
| Package | 8-pin VSSOP (DGK) | 8-pin VSSOP (DGK) |
| Brand | Texas Instruments | Texas Instruments |
| Supply Voltage Range | 2.7 V to 5.5 V | 2.7 V to 5.5 V |
| Number of Channels | 1 channel | 1 channel |
| Programmable Gain Range | 0.1 V/V to 1000 V/V | 0.1 V/V to 1000 V/V |
| Maximum Input Offset Voltage | 100 µV | 100 µV |
| Input Noise Density | 33 nV/√Hz typical at 1 kHz | 33 nV/√Hz typical at 1 kHz |
| Gain Bandwidth | 1 kHz, with 114 dB typical gain bandwidth | 1 kHz, with 114 dB typical gain bandwidth |
| Input and Output Capability | Rail-to-rail input and output | Rail-to-rail input and output |
| Operating Temperature Range | -40 °C to +85 °C | -40 °C to +85 °C |
| Technology | Precision, low-drift CMOS | Precision, low-drift CMOS |
מבדילים עיקריים
- Exact same electrical and package configuration (לעומתINA326EA/250G4)
- Rail-to-rail differential signal interface (לעומתINA326EA/250G4)
- Precision noise and offset performance (לעומתINA326EA/250G4)
הערות תכנון
Route the two inputs as a compact differential pair and connect the gain-setting resistor directly to the RG pin with a short, low-inductance trace. Keep the input network close to the amplifier to minimize parasitic capacitance and susceptibility to coupled noise. For a bridge sensor, maintain symmetrical geometry between the excitation and sensing paths so that a small physical disturbance does not become a differential measurement error.
Do not select the gain solely to make the signal appear large. First verify the sensor's output range, common-mode voltage, required bandwidth, and allowable error, then check that the amplified output can settle within the system's input range. The device is optimized for precision, 1 kHz-bandwidth measurements; excessive gain can consume output swing or reduce usable bandwidth before conversion.
Place the device's supply decoupling capacitor next to the supply and ground pins, and use a short ground return to minimize supply ripple and ground bounce. Apply filtering after amplification when the bandwidth requirement permits it. Account for the amplifier's 33 nV/√Hz input noise, the gain-setting resistor's own thermal noise, and the ADC's input-referred noise when establishing an end-to-end noise target.
מידע על תאימות
RoHS compliance is identified in the Mouser product listing. No additional REACH, halogen-free, conflict-minerals, or automotive qualification statement is confirmed.