INA326EA/250 - 1kHz Precision Instrumentation Amplifier | TI
料号: INA326EA/250 ✓ 量产中INA326EA/250 概述
An instrumentation amplifier is a specialized analog amplifier optimized for measuring small differential signals while rejecting common-mode interference. Its internal architecture provides gain, differential sensing, and input common-mode rejection in one device. Within the broader hierarchy, an instrumentation amplifier is an amplifier IC and a precision signal-conditioning component used ahead of converters, sensors, and data-acquisition systems. The INA326 family is designed for systems requiring low drift, low noise, and rail-to-rail signal-chain flexibility.
Key characteristics include one amplifier channel, a 0.1 V/V to 1000 V/V programmable gain range, rail-to-rail inputs and outputs, a 2.7 V to 5.5 V supply range, and operation from -40 °C to 85 °C. The combination of 100 µV maximum input offset and 33 nV/√Hz typical noise supports accurate extraction of low-level differential signals. The 1 kHz gain-bandwidth characteristic makes the device suitable for precision rather than high-speed signal acquisition.
The INA326EA/250 uses a CMOS implementation to combine low input bias current, low offset voltage, and low drift with rail-to-rail input and output behavior. Because its output can approach the supply rails, downstream circuitry can use a wide portion of the available analog voltage range. Its programmable gain allows one device family to serve applications ranging from modest differential amplification to high-gain sensor conditioning while preserving the same 8-pin footprint.
Typical uses include bridge and strain-gauge signal conditioning, low-level current measurement, precision sensor interfaces, medical instrumentation, industrial process measurement, and data-acquisition front ends. The device is particularly appropriate when the target signal is differential, the common-mode environment is demanding, and measurement accuracy matters more than wideband throughput. A suitable analog-to-digital converter can then digitize the conditioned output.
A key design consideration is to preserve the differential nature of the input signal. Keep input routing compact, use symmetric interconnections where practical, and place the gain-setting resistor close to the RG pin. Follow the Texas Instruments datasheet pin-description table when assigning PCB tracks, and confirm that the selected gain, supply voltage, and output-swing requirements remain compatible with the intended sensor.
This page consolidates the Texas Instruments product characteristics, ordering information, package details, technical comparisons, and application guidance for engineers evaluating the INA326EA/250. It also organizes drop-in ordering options, practical design considerations, and search-focused technical information into one engineering reference.
直接替换替代料: INA326EA/250 ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
INA326EA/250G4
✅ 直接替换📋 参考替代料(不在目录中)
INA326EA/250 最大额定值与电气特性
| Product Type | Precision CMOS instrumentation amplifier, 1 amplifier channel |
| Supply Voltage Range | 2.7 V to 5.5 V |
| Gain Bandwidth | 1 kHz |
| Typical Gain Bandwidth | 114 dB at 1 kHz |
| Maximum Input Offset Voltage | 100 µV |
| Input Noise Density | 33 nV/√Hz typical at 1 kHz |
| Programmable Gain Range | 0.1 V/V to 1000 V/V |
| Input Common-Mode Capability | Rail-to-rail |
| Output Swing Capability | Rail-to-rail |
| Number of Channels | 1 channel |
| Technology | CMOS |
| 工作温度范围 | -40 °C to +85 °C |
| 封装 | 8-pin VSSOP (DGK) |
| 安装类型 | Surface mount |
| RoHS 状态 | Compliant |
INA326EA/250 8-pin vssop (dgk) 引脚配置指南
INA326EA/250(8-pin vssop (dgk) 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: INA326EA/250.
请参阅 数据手册 以查看完整引脚配置。
典型应用
INA326EA/250 适用于 6 应用s: Strain-Gauge and Bridge Sensor Conditioning, Precision Current Measurement, Medical and Diagnostic Instrumentation, Industrial Process Measurement, Data-Acquisition Front Ends, Portable Sensor and IoT Interfaces.
Strain-Gauge and Bridge Sensor Conditioning
The INA326EA/250 fits low-level bridge measurements where differential excitation produces a small output around a substantial common-mode voltage. Its rail-to-rail input operation, 100 µV maximum input offset voltage, and programmable gain from 0.1 V/V to 1000 V/V help preserve accuracy while amplifying the bridge imbalance. The device is normally placed between the bridge and an ADC, with the gain-setting resistor connected according to the manufacturer configuration. Keep bridge excitation and sense paths short and symmetrical to reduce pickup and imbalance error.
推荐
Precision Current Measurement
The INA326EA/250 can amplify the voltage generated by a current shunt or current-transformer secondary when the signal is differential and low amplitude. Its 33 nV/√Hz typical input noise and low offset support measurements where the useful signal is close to the amplifier noise and offset limits. Because it is a precision, 1 kHz-bandwidth device rather than a wideband amplifier, the application benefits most when the measured current changes slowly enough for accurate settling and filtering.
推荐
Medical and Diagnostic Instrumentation
The INA326EA/250 is appropriate for biomedical front ends that measure small differential sensor signals while rejecting interference from the surrounding environment. Rail-to-rail input and output capability provides useful signal range from a 2.7 V to 5.5 V supply, while the 100 µV maximum offset supports a low baseline error. For patient-connected or diagnostic equipment, engineers must also evaluate isolation, protection, leakage, safety, and applicable medical requirements separately from the amplifier's performance ratings.
推荐
Industrial Process Measurement
The INA326EA/250 supports low-level industrial sensor interfaces where a transducer produces a differential voltage and the controller requires accurate amplification before conversion. Its precision CMOS architecture, low-drift positioning, rail-to-rail I/O, and programmable gain suit pressure, temperature, and process-control signals. The 1 kHz gain-bandwidth characteristic limits high-speed transient capture, so the interface should include suitable filtering and ensure that amplifier settling meets the control-loop timing requirements.
推荐
Data-Acquisition Front Ends
The INA326EA/250 can serve as the analog gain stage immediately before an ADC in a precision data-acquisition channel. A gain of 0.1 V/V to 1000 V/V allows the same amplifier family to handle signals of different amplitudes, while the 114 dB typical gain bandwidth at 1 kHz supports accurate low-frequency measurements. Use close input routing, a compact gain resistor, and appropriate anti-alias filtering. The ADC selection should match the amplifier's output swing, bandwidth, noise, and conversion requirements.
推荐
Portable Sensor and IoT Interfaces
The INA326EA/250 is suitable for battery-powered sensor nodes when the sensor output is small and differential and the system operates from a low-voltage rail. Its supply range begins at 2.7 V, and rail-to-rail input and output behavior can improve utilization of the available voltage in compact designs. The precision nature of the amplifier makes it useful for environmental, wearable, and condition-monitoring nodes. Designers should account for supply noise, sensor excitation, ADC conversion time, and the amplifier's own current consumption when calculating battery life.
推荐
推荐产品汇总
工程参考数据: INA326EA/250 ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | INA326EA/250G4 |
|---|---|---|
| Package | 8-pin VSSOP (DGK) | 8-pin VSSOP (DGK) |
| Brand | Texas Instruments | Texas Instruments |
| Supply Voltage Range | 2.7 V to 5.5 V | 2.7 V to 5.5 V |
| Number of Channels | 1 channel | 1 channel |
| Programmable Gain Range | 0.1 V/V to 1000 V/V | 0.1 V/V to 1000 V/V |
| Maximum Input Offset Voltage | 100 µV | 100 µV |
| Input Noise Density | 33 nV/√Hz typical at 1 kHz | 33 nV/√Hz typical at 1 kHz |
| Gain Bandwidth | 1 kHz, with 114 dB typical gain bandwidth | 1 kHz, with 114 dB typical gain bandwidth |
| Input and Output Capability | Rail-to-rail input and output | Rail-to-rail input and output |
| Operating Temperature Range | -40 °C to +85 °C | -40 °C to +85 °C |
| Technology | Precision, low-drift CMOS | Precision, low-drift CMOS |
关键差异点
- Exact same electrical and package configuration (对比 INA326EA/250G4)
- Rail-to-rail differential signal interface (对比 INA326EA/250G4)
- Precision noise and offset performance (对比 INA326EA/250G4)
设计说明
Route the two inputs as a compact differential pair and connect the gain-setting resistor directly to the RG pin with a short, low-inductance trace. Keep the input network close to the amplifier to minimize parasitic capacitance and susceptibility to coupled noise. For a bridge sensor, maintain symmetrical geometry between the excitation and sensing paths so that a small physical disturbance does not become a differential measurement error.
Do not select the gain solely to make the signal appear large. First verify the sensor's output range, common-mode voltage, required bandwidth, and allowable error, then check that the amplified output can settle within the system's input range. The device is optimized for precision, 1 kHz-bandwidth measurements; excessive gain can consume output swing or reduce usable bandwidth before conversion.
Place the device's supply decoupling capacitor next to the supply and ground pins, and use a short ground return to minimize supply ripple and ground bounce. Apply filtering after amplification when the bandwidth requirement permits it. Account for the amplifier's 33 nV/√Hz input noise, the gain-setting resistor's own thermal noise, and the ADC's input-referred noise when establishing an end-to-end noise target.
合规信息
RoHS compliance is identified in the Mouser product listing. No additional REACH, halogen-free, conflict-minerals, or automotive qualification statement is confirmed.