MAX211EEWI+ - 15kV ESD 4/5 RS-232 Transceiver | Maxim
MPN: MAX211EEWI+ ✓ सक्रियMAX211EEWI+ अवलोकन
An RS-232 transceiver is an interface IC that converts logic-level signals to and from RS-232 line levels. It belongs to the transceiver class, interface IC hierarchy, and broader semiconductor category. The MAX211EEWI+ combines four driver channels with five receiver channels, allowing multiple serial ports or asymmetric communication paths to share one package while providing a standardized physical interface for data transmission.
Key features include 15kV ESD protection, TTL-compatible tri-state driver operation, and operation from a 4.5V to 5.5V supply. The integrated charge pump eliminates the need for a separate external charge-pump supply arrangement for standard single-supply RS-232 operation. Its four-driver and five-receiver organization also provides receiver headroom when a system requires more receive channels than transmit channels.
The E suffix identifies the electrically enhanced device family, while the wider temperature capability associated with the EWI+ ordering code is -40°C to +85°C. The MAX211 family is also offered in 28-pin wide SO and SSOP configurations, but the target ordering code uses the 28-pin wide SOIC package. Exact propagation delay, slew rate, receiver thresholds, and input capacitance should be confirmed against the manufacturer datasheet before finalizing a high-speed interface design.
Typical uses include industrial serial-port equipment, data acquisition systems, instrumentation, control panels, and embedded systems that connect TTL or CMOS logic to RS-232 equipment. The five-receiver, four-driver arrangement is particularly useful where more input channels are required than output channels. Integrating the charge pump also reduces external circuitry and simplifies single-rail implementation compared with charge-pump-free or externally assisted alternatives.
Designers should verify signal-level compatibility, grounding, connector selection, and cable length for the selected RS-232 standard. ESD protection is valuable at the connector interface, but external protection may still be needed for severe industrial surge environments. Keep ground and signal routing controlled, place the charge-pump capacitors close to their specified pins, and avoid using TTL outputs without first confirming the required driver-enable and tri-state behavior.
This page combines the Maxim family specifications, verified distributor listings, pin-compatible family alternatives, and application-focused engineering guidance to support component selection and PCB design planning.
के लिए ड्रॉप-इन विकल्प MAX211EEWI+ — समान पैकेज, पिन-टू-पिन संगत। PCB रीवर्क आवश्यक करने वाले भिन्न-पैकेज पार्ट्स शामिल नहीं हैं।
इस सीरीज़ के वेरिएंट
समान श्रृंखला के मॉडल जो ड्रॉप-इन संगत हैं MAX211EEWI+ (समान फॉर्म फैक्टर और फुटप्रिंट) — इसमें भिन्न Package, Receiver Count, Driver Count, Supply Voltage.
MAX211ECWI+
✅ ड्रॉप-इनकीमत के लिए संपर्क करें
डेटाशीट देखें →MAX211EWI+
✅ ड्रॉप-इनकीमत के लिए संपर्क करें
डेटाशीट देखें →MAX213EEWI
✅ ड्रॉप-इन ⚠️ विनिर्देश असत्यापित📋 संदर्भ विकल्प (कैटलॉग में नहीं)
MAX241EEWI
✅ ड्रॉप-इन📋 संदर्भ विकल्प (कैटलॉग में नहीं)
MAX211EEWI+ विशेषताएं
| Transceiver Configuration | 4 drivers / 5 receivers |
| Interface Standard | RS-232 |
| Supply Voltage Range | 4.5V to 5.5V |
| Nominal Supply Voltage | +5V |
| Driver Count | 4 channels |
| Receiver Count | 5 channels |
| ESD Protection | ±15kV |
| Charge Pump | Integrated |
| Driver Output Type | TTL tri-state |
| पैकेज | 28-pin WSOIC |
| Package Family | Wide small-outline IC |
| माउंटिंग प्रकार | Surface mount |
| Minimum Operating Temperature | -40°C |
| Maximum Operating Temperature | +85°C |
| Operating Supply Range | 4.5V to 5.5V |
MAX211EEWI+ wide small-outline ic पिन कॉन्फ़िगरेशन गाइड
MAX211EEWI+ (wide small-outline ic पैकेज) के लिए पिन कॉन्फ़िगरेशन। पिन नंबरिंग, फ़ंक्शन और कनेक्शन आरेख निर्माता डेटाशीट में परिभाषित हैं। सटीक फुटप्रिंट और सोल्डरिंग दिशानिर्देशों के लिए इसे देखें।
इसके लिए कोई विस्तृत pinout data उपलब्ध नहीं: MAX211EEWI+.
देखें डेटाशीट पूर्ण पिन कॉन्फ़िगरेशन के लिए।
सामान्य अनुप्रयोग
MAX211EEWI+ के लिए उपयुक्त है 6 अनुप्रयोगs: Industrial RS-232 Data Acquisition, Instrumentation and Test Equipment, Embedded Serial Communication Controller, Serial Control Panel, Point-of-Sale and Peripheral Interface, Industrial Communication Gateway.
Industrial RS-232 Data Acquisition
The MAX211EEWI+ fits industrial data-acquisition equipment that must translate between TTL or CMOS controller logic and RS-232 instruments. Its 4.5V to 5.5V operating range supports conventional 5V systems, while the integrated charge pump simplifies single-rail implementation. Four driver and five receiver channels provide asymmetric connectivity for controlling one or more peripherals and collecting status data. The -40°C to +85°C rating is useful in factory environments, and ±15kV ESD protection improves interface resilience, although connector-level surge protection may still be required.
अनुशंसित
Instrumentation and Test Equipment
The MAX211EEWI+ is appropriate for laboratory and field instrumentation that uses legacy RS-232 links for control, logging, or service access. Four driver outputs can connect multiple enabled receivers, while five receiver channels support multiple incoming data sources. Its integrated charge pump reduces the number of external support components compared with designs that provide a separate boosted supply. The wide-SOIC package remains compatible with conventional through-hole-style PCB assembly practices, and the -40°C to +85°C range supports temperature-controlled industrial test systems.
अनुशंसित
Embedded Serial Communication Controller
The MAX211EEWI+ can serve as the physical-layer complement to an embedded UART or microprocessor in systems that still require RS-232 connectivity. The four-driver and five-receiver organization allows several serial links to share one interface IC, reducing board area relative to separate single-channel transceivers. TTL tri-state outputs support shared-bus arrangements when the host firmware controls driver enable timing correctly. Single-supply operation from 4.5V to 5.5V and integrated charge-pump circuitry simplify connections to 5V embedded systems, though modern designs often prefer USB or differential interfaces when the physical standard permits.
अनुशंसित
Serial Control Panel
A MAX211EEWI+ is useful in a human-machine-interface control panel that must retain a wired RS-232 command port. The five receiver channels can accept data from multiple panel modules, while four driver channels support communication with up to four enabled receiving nodes. The integrated charge pump allows operation from one 5V rail, making the device suitable for space-constrained electronics with limited power distribution. ESD protection is valuable around touchable or externally accessible equipment, but the final design should still use a suitable connector, chassis grounding, and protection network for its installation environment.
अनुशंसित
Point-of-Sale and Peripheral Interface
The MAX211EEWI+ can bridge a controller to RS-232 peripherals such as scanners, printers, or service terminals in legacy point-of-sale equipment. Four driver channels accommodate several enabled peripheral inputs, and five receiver channels can collect acknowledgements or status signals. The 4.5V to 5.5V supply range aligns with many embedded 5V systems, while the integrated charge pump avoids a separate negative-voltage generation circuit. Because exposed RS-232 ports are susceptible to both ESD and larger surge transients, the board design should combine the device's internal protection with appropriately rated external protection and robust signal grounding.
अनुशंसित
Industrial Communication Gateway
The MAX211EEWI+ is suitable for a communication gateway that bridges a legacy RS-232 device to a modern embedded controller. Its four drivers and five receivers support several physical channels while preserving a compact 28-pin wide-SOIC footprint. The integrated charge pump permits straightforward 5V-only implementation, and the -40°C to +85°C rating supports deployment in unheated industrial enclosures. Signal-integrity planning should account for unequal driver and receiver counts, the tri-state control state of unused outputs, and the potential for ground-potential differences between equipment connected through long RS-232 cables.
अनुशंसित
अनुशंसित उत्पादों का सारांश
के लिए इंजीनियरिंग संदर्भ डेटा MAX211EEWI+ — तुलना, डिज़ाइन मार्गदर्शन और अनुपालन जानकारी।
चयन गाइड
विकल्पों के साथ तुलना
| पैरामीटर | यह उत्पाद | MAX211ECWI+ | MAX211EWI | MAX213EEWI | MAX241EEWI |
|---|---|---|---|---|---|
| Brand | Maxim Integrated | Maxim Integrated | Maxim Integrated | Maxim Integrated | Maxim Integrated |
| Package | 28-SOIC | 28-SOIC - same | 28-SOIC - same | 28-SOIC - same | 28-SOIC - same |
मुख्य विशेषताएँ
- Broader industrial temperature coverage (बनामMAX211ECWI+)
- Four-driver and five-receiver configuration (बनामMAX241EEWI)
- Single 5V rail with integrated charge pump (बनामMAX213EEWI)
डिज़ाइन नोट्स
Place the charge-pump capacitors and the required input and output bypass capacitors directly beside their associated pins. Keep the charge-pump loop compact because long PCB traces can increase radiated noise and reduce margin on the RS-232 driver outputs. Use the manufacturer's recommended capacitance and ESR values, and route connector-side protection components close to the external pins rather than back toward the transceiver.
Do not enable multiple driver outputs onto the same RS-232 node unless the system intentionally supports that connection and the outputs are designed for it. TTL tri-state control must leave unused drivers in a high-impedance state. Confirm the receiver enable or shutdown polarity in the manufacturer pin table because a wrong control-state interpretation can prevent communication or create excessive bus contention.
The ±15kV ESD rating is not equivalent to unlimited surge withstand. For cables leaving an enclosure, combine the internal protection with connector placement, chassis or signal-ground strategy, and external surge protection appropriate to the installation. Keep long RS-232 traces away from clocks, switching inductors, and high-current return paths to reduce common-mode noise and false receive transitions.
Use a solid low-impedance ground plane for the transceiver and provide an unobstructed return path beneath or near the interface traces. Avoid splitting the ground plane beneath the wide-SOIC footprint, and avoid routing high-speed digital signals directly beneath charge-pump nodes. Maintain practical separation between outgoing and incoming RS-232 channels when their ground references or cable routes differ.
अनुपालन जानकारी
No specific RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status was identified for the target ordering code. The manufacturer family is described as operating in harsh environments, but this does not establish a formal compliance qualification.