What is a Layer-2 managed Ethernet switch? A Layer-2 managed Ethernet switch is a networking IC that operates at the data-link layer (MAC) of the OSI model, forwarding Ethernet frames between ports based on MAC address tables while supporting management features such as VLAN tagging (IEEE 802.1Q), QoS prioritization (IEEE 802.1p), port mirroring, IGMP snooping, and rate limiting. The KSZ8895 belongs to the Fast-Ethernet switch family within the broader category of Ethernet controllers, which sit above physical-layer transceivers (PHYs) in the networking semiconductor hierarchy.
Key features include five 10/100Base-TX ports with auto-negotiation and auto-MDI/MDIX, an integrated 1.4 Gbps switch fabric with 64 KB frame buffer, support for 4K-entry MAC address table, IEEE 802.1Q VLAN with 16 VLAN groups, IEEE 802.1p QoS with four priority queues, and per-port programmable head-of-line blocking prevention. The device operates from a single 3.3 V supply with internal 1.8 V LDO and supports commercial (0C to 70C) and industrial (-40C to 85C) temperature ranges.
The KSZ8895MQXI uses a store-and-forward switching architecture with a 32-bit MIPS-style management interface accessible via SPI or I2C. Its integrated PHYs include HP Auto-MDIX crossover detection on all five ports, eliminating external magnetics-center-tap resistors in many designs. The 128-pin PQFP package provides generous PCB escape routing for high-density industrial designs.
Typical applications include industrial Ethernet switches, automotive gateway ECUs, IP surveillance NVR/DVR systems, building automation controllers, and IoT edge gateways requiring deterministic Layer-2 switching. The KSZ8895 is commonly used in PROFINET, EtherCAT, and Modbus TCP environments.
When designing with this device, note that the 128-pin PQFP requires a 4-layer PCB minimum for proper return-path integrity on the MII/RMII bus. Use a 25 MHz crystal with 50 ppm accuracy for the reference clock and place decoupling capacitors (0.1 uF plus 10 uF bulk) within 3 mm of each supply pin.
Alternatif penggantian untuk KSZ8895MQXI — paket yang sama, pin-pada-pin kompatibel. Bagian paket yang berbeda memerlukan kerja ulang PCB diabaikan.
Variasi di dalam seri ini
Model-series yang sama yang kompatibel dengan penggantian KSZ8895MQXI (sama faktor bentuk dan footprint) — berbeda di dalam Package, Product Type, Host Interface, Number of Ports, Operating Temperature.
KSZ8895RQXIA
✅ Drop-In📋 Alternatif referensi (tidak dalam katalog)
KSZ8895MLUB
✅ Drop-In📋 Alternatif referensi (tidak dalam katalog)
KSZ8895FQX
✅ Drop-In📋 Alternatif referensi (tidak dalam katalog)
KSZ8995MA
✅ Drop-In📋 Alternatif referensi (tidak dalam katalog)
KSZ8895MQXI Rating Maksimal & Karakteristik Listrik
| Product Type | Ethernet Switch IC |
| Number of Ports | 5 (10/100Base-TX) |
| Switch Fabric Bandwidth | 1.4 Gbps non-blocking |
| PHY Standard | IEEE 802.3u 100Base-TX / IEEE 802.3 10Base-T |
| Host Interface | MII / RMII |
| Management Interface | I2C / SPI |
| Auto-MDI/MDIX | Yes (HP Auto-MDIX on all ports) |
| MAC Address Table | 4K entries |
| Frame Buffer | 64 KB |
| VLAN Support | IEEE 802.1Q, 16 VLAN groups |
| QoS Support | IEEE 802.1p, 4 priority queues |
| Tegangan Pemuat | 3.3 V (single supply, internal 1.8 V LDO) |
| Suhu Kerja | -40C to +85C (industrial grade) |
| Paket | 128-pin PQFP (14x20 mm) |
| Tipe Mounting | Surface Mount |
| Status RoHS | Compliant |
| AEC-Q100 | Qualified (automotive grade) |
Konfigurasi Pin KSZ8895MQXI
| Pin produk 1 | TX1P — Port 1 PHY transmit positive |
| Pin produk 2 | TX1N — Port 1 PHY transmit negative |
| Pin produk 3 | RX1P — Port 1 PHY receive positive |
| Pin produk 4 | RX1N — Port 1 PHY receive negative |
| Pin produk 5 | VDDIO — 3.3V I/O supply |
| Pin produk 6 | GND — Ground |
| Pin produk 7 | TX2P — Port 2 PHY transmit positive |
| Pin produk 8 | TX2N — Port 2 PHY transmit negative |
| Pin produk 9 | RX2P — Port 2 PHY receive positive |
| Pin produk 10 | RX2N — Port 2 PHY receive negative |
| Pin produk 11 | VDDCORE — Internal 1.8V LDO output (decouple with 0.1uF + 10uF) |
| Pin produk 12 | TX3P — Port 3 PHY transmit positive |
| Pin produk 13 | TX3N — Port 3 PHY transmit negative |
| Pin produk 14 | RX3P — Port 3 PHY receive positive |
| Pin produk 15 | RX3N — Port 3 PHY receive negative |
| Pin produk 16 | GND — Ground |
| Pin produk 17 | TX4P — Port 4 PHY transmit positive |
| Pin produk 18 | TX4N — Port 4 PHY transmit negative |
| Pin produk 19 | RX4P — Port 4 PHY receive positive |
| Pin produk 20 | RX4N — Port 4 PHY receive negative |
| Pin produk 21 | VDDIO — 3.3V I/O supply |
| Pin produk 22 | TX5P — Port 5 PHY transmit positive |
| Pin produk 23 | TX5N — Port 5 PHY transmit negative |
| Pin produk 24 | RX5P — Port 5 PHY receive positive |
| Pin produk 25 | RX5N — Port 5 PHY receive negative |
| Pin produk 26 | GND — Ground |
| Pin produk 27 | CRS_DV — MII carrier sense / data valid (host port) |
| Pin produk 28 | RXD0 — MII receive data bit 0 (host port) |
| Pin produk 29 | RXD1 — MII receive data bit 1 (host port) |
| Pin produk 30 | RXD2 — MII receive data bit 2 (host port) |
| Pin produk 31 | RXD3 — MII receive data bit 3 (host port) |
| Pin produk 32 | RXER — MII receive error (host port) |
| Pin produk 33 | RXCLK — MII receive clock (host port) |
| Pin produk 34 | TXEN — MII transmit enable (host port) |
| Pin produk 35 | TXD0 — MII transmit data bit 0 (host port) |
| Pin produk 36 | TXD1 — MII transmit data bit 1 (host port) |
| Pin produk 37 | TXD2 — MII transmit data bit 2 (host port) |
| Pin produk 38 | TXD3 — MII transmit data bit 3 (host port) |
| Pin produk 39 | TXER — MII transmit error (host port) |
| Pin produk 40 | TXCLK — MII transmit clock (host port) |
| Pin produk 41 | MDC — MII management data clock |
| Pin produk 42 | MDIO — MII management data I/O |
| Pin produk 43 | COL — MII collision detect (host port) |
| Pin produk 44 | CRS — MII carrier sense (host port) |
| Pin produk 45 | LED1_0 — Port 1 LED0 (link/activity) |
| Pin produk 46 | LED1_1 — Port 1 LED1 (speed) |
| Pin produk 47 | LED2_0 — Port 2 LED0 (link/activity) |
| Pin produk 48 | LED2_1 — Port 2 LED1 (speed) |
| Pin produk 49 | LED3_0 — Port 3 LED0 (link/activity) |
| Pin produk 50 | LED3_1 — Port 3 LED1 (speed) |
| Pin produk 51 | LED4_0 — Port 4 LED0 (link/activity) |
| Pin produk 52 | LED4_1 — Port 4 LED1 (speed) |
| Pin produk 53 | LED5_0 — Port 5 LED0 (link/activity) |
| Pin produk 54 | LED5_1 — Port 5 LED1 (speed) |
| Pin produk 55 | GND — Ground |
| Pin produk 56 | SCL — I2C serial clock (management) |
| Pin produk 57 | SDA — I2C serial data (management) |
| Pin produk 58 | SPIS_N — SPI slave select (active low) |
| Pin produk 59 | SPIS_SCK — SPI serial clock |
| Pin produk 60 | SPIS_SDI — SPI slave data in |
| Pin produk 61 | SPIS_SDO — SPI slave data out |
| Pin produk 62 | SPIS_INTN — SPI interrupt output (active low) |
| Pin produk 63 | RESETN — Hardware reset (active low) |
| Pin produk 64 | TEST — Factory test pin (tie to GND in application) |
| Pin produk 65 | VDDIO — 3.3V I/O supply |
| Pin produk 66 | GND — Ground |
| Pin produk 67 | PWRDN — Power-down mode input |
| Pin produk 68 | EN_REF_CLK — Enable reference clock output |
| Pin produk 69 | NC — Not connected (per datasheet) |
| Pin produk 70 | NC — Not connected (per datasheet) |
| Pin produk 71 | GND — Ground |
| Pin produk 72 | VDDCORE — Internal 1.8V LDO output (decouple with 0.1uF + 10uF) |
| Pin produk 73 | XTAL1 — Crystal oscillator input (25 MHz) |
| Pin produk 74 | XTAL2 — Crystal oscillator output (25 MHz) |
| Pin produk 75 | GND — Ground |
| Pin produk 76 | TX_ER_PORT5 — Port 5 transmit error indicator |
| Pin produk 77 | TX_EN_PORT5 — Port 5 transmit enable (extended MII) |
| Pin produk 78 | TXD_PORT5_0 — Port 5 transmit data 0 |
| Pin produk 79 | TXD_PORT5_1 — Port 5 transmit data 1 |
| Pin produk 80 | TXD_PORT5_2 — Port 5 transmit data 2 |
| Pin produk 81 | TXD_PORT5_3 — Port 5 transmit data 3 |
| Pin produk 82 | TX_CLK_PORT5 — Port 5 transmit clock (extended MII) |
| Pin produk 83 | RX_DV_PORT5 — Port 5 receive data valid |
| Pin produk 84 | RXD_PORT5_0 — Port 5 receive data 0 |
| Pin produk 85 | RXD_PORT5_1 — Port 5 receive data 1 |
| Pin produk 86 | RXD_PORT5_2 — Port 5 receive data 2 |
| Pin produk 87 | RXD_PORT5_3 — Port 5 receive data 3 |
| Pin produk 88 | RX_ER_PORT5 — Port 5 receive error |
| Pin produk 89 | RX_CLK_PORT5 — Port 5 receive clock |
| Pin produk 90 | MDIO_PORT5 — Port 5 MII management data I/O |
| Pin produk 91 | MDC_PORT5 — Port 5 MII management clock |
| Pin produk 92 | GND — Ground |
| Pin produk 93 | TDI — JTAG test data in |
| Pin produk 94 | TDO — JTAG test data out |
| Pin produk 95 | TMS — JTAG test mode select |
| Pin produk 96 | TCK — JTAG test clock |
| Pin produk 97 | TRSTN — JTAG test reset (active low) |
| Pin produk 98 | VDDIO — 3.3V I/O supply |
| Pin produk 99 | NC — Not connected (per datasheet) |
| Pin produk 100 | NC — Not connected (per datasheet) |
| Pin produk 101 | GND — Ground |
| Pin produk 102 | VDD_PLL — PLL analog supply (3.3V, decouple with 0.1uF) |
| Pin produk 103 | GND_PLL — PLL analog ground |
| Pin produk 104 | NC — Not connected (per datasheet) |
| Pin produk 105 | NC — Not connected (per datasheet) |
| Pin produk 106 | VDDIO — 3.3V I/O supply |
| Pin produk 107 | GPIO0 — General-purpose I/O 0 |
| Pin produk 108 | GPIO1 — General-purpose I/O 1 |
| Pin produk 109 | GPIO2 — General-purpose I/O 2 |
| Pin produk 110 | GPIO3 — General-purpose I/O 3 |
| Pin produk 111 | GPIO4 — General-purpose I/O 4 |
| Pin produk 112 | GPIO5 — General-purpose I/O 5 |
| Pin produk 113 | GPIO6 — General-purpose I/O 6 |
| Pin produk 114 | GPIO7 — General-purpose I/O 7 |
| Pin produk 115 | GND — Ground |
| Pin produk 116 | REF_CLK — Reference clock output (25 MHz) |
| Pin produk 117 | CLK_OUT — Buffered clock output |
| Pin produk 118 | NC — Not connected (per datasheet) |
| Pin produk 119 | NC — Not connected (per datasheet) |
| Pin produk 120 | VDDIO — 3.3V I/O supply |
| Pin produk 121 | NC — Not connected (per datasheet) |
| Pin produk 122 | NC — Not connected (per datasheet) |
| Pin produk 123 | NC — Not connected (per datasheet) |
| Pin produk 124 | NC — Not connected (per datasheet) |
| Pin produk 125 | NC — Not connected (per datasheet) |
| Pin produk 126 | NC — Not connected (per datasheet) |
| Pin produk 127 | NC — Not connected (per datasheet) |
| Pin produk 128 | NC — Not connected (per datasheet) |
Aplikasi Umum
KSZ8895MQXI cocok untuk 6 aplikasis: Industrial Ethernet Switch, Automotive Gateway ECU, IP Surveillance NVR/DVR, Building Automation Controller, IoT Edge Gateway, Power Substation Communications.
Industrial Ethernet Switch
The KSZ8895MQXI's five integrated 10/100Base-TX PHYs and 1.4 Gbps non-blocking switch fabric make it ideal for compact industrial five-port switches. The device supports IEEE 802.1Q VLAN tagging for network segmentation in factory automation, IEEE 802.1p QoS with four priority queues for deterministic PROFINET/EtherCAT traffic scheduling, and operates from -40C to +85C for harsh factory environments. Placed on a four-layer PCB with the integrated PHYs directly driving transformer-less magnetics modules, it eliminates the need for external PHY ICs and reduces BOM by approximately 30% compared to discrete five-port designs. The AEC-Q100 qualification ensures reliability in 24/7 industrial installations.
Direkomendasikan
Automotive Gateway ECU
In automotive gateway ECUs, the KSZ8895MQXI aggregates multiple in-vehicle network domains (CAN, LIN, Ethernet) onto a backbone Ethernet switch. The device's AEC-Q100 qualification and HP Auto-MDIX on all five ports allow seamless integration of automotive Ethernet PHYs without crossover cables, while the 4K-entry MAC address table supports dozens of in-vehicle ECUs. The integrated 1.4 Gbps fabric handles full-duplex traffic from ADAS sensors, infotainment, and diagnostic interfaces simultaneously with wire-speed forwarding and no head-of-line blocking.
Direkomendasikan
IP Surveillance NVR/DVR
The KSZ8895MQXI enables five-port managed Ethernet switches inside IP surveillance NVR and DVR systems, connecting multiple PoE IP cameras to a recording engine. Its 64 KB frame buffer absorbs burst traffic from multiple 1080p H.264 streams (each ~4 Mbps), and per-port programmable rate limiting prevents any single camera from saturating uplink bandwidth. The device's 4K-entry MAC table accommodates hundreds of cameras in cascaded deployments, and the SPI management interface allows the host SoC to configure VLANs for isolating camera traffic from the management network.
Direkomendasikan
Building Automation Controller
In building automation controllers, the KSZ8895MQXI serves as the central Ethernet switch connecting BACnet/IP, Modbus TCP, and KNX/IP subsystems. The IEEE 802.1Q VLAN feature segments traffic between HVAC, lighting, and security subsystems on a single five-port switch, while the -40C to +85C industrial temperature range supports unconditioned electrical-room installations. The integrated 1.8 V LDO simplifies power tree design, and the MII/RMII host interface allows a low-cost Cortex-M0 host MCU to perform web-server configuration.
Direkomendasikan
IoT Edge Gateway
IoT edge gateways use the KSZ8895MQXI to aggregate multiple Ethernet-connected sensors and actuators onto a single uplink to the cloud. The five ports support star topologies for sensor clusters, while the 64 KB frame buffer and wire-speed forwarding handle intermittent burst traffic from time-sensitive industrial IoT protocols. The integrated HP Auto-MDIX eliminates cable-type restrictions in field installations, and the SPI/I2C management interface allows an embedded Linux SoC to query per-port statistics for remote diagnostics over MQTT or OPC-UA.
Direkomendasikan
Power Substation Communications
In IEC 61850 power substation communications, the KSZ8895MQXI provides five managed Ethernet ports for connecting protection relays, phasor measurement units (PMUs), and SCADA gateways. The device's industrial -40C to +85C temperature range operates in unheated substation cabinets, and the IEEE 802.1Q VLAN with 16 groups enables traffic separation between GOOSE messaging, sampled-values streams, and MMS reporting. The 1.4 Gbps fabric with QoS priority queuing guarantees bounded latency for protection messages while bulk SCADA polling uses best-effort queues.
Direkomendasikan
Ringkasan Produk Direkomendasikan
Data referensi engineering untuk KSZ8895MQXI — pembandingan, panduan desain, dan informasi konformitas.
Panduan Pemilihan
Pembandingan dengan Alternatif
| Parameter Umum | Produk Ini | KSZ8895RQXIA | KSZ8895MLUB | KSZ8895FQX | KSZ8995MA |
|---|---|---|---|---|---|
| Package | 128-PQFP (14x20) | 128-PQFP (14x20) - same | 128-PQFP (14x20) - same | 128-PQFP (14x20) - same | 128-PQFP (14x20) - same |
| Brand | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology |
| Number of Ports | 5 (10/100Base-TX) | 5 (10/100Base-TX) | 5 (10/100Base-TX) | 5 (10/100Base-TX) | 5 (10/100Base-TX) |
| Integrated PHYs | 5 PHYs | 5 PHYs | 5 PHYs | 5 PHYs | 3 PHYs |
| AEC-Q100 | Qualified | Grade-2 Qualified | Not qualified | Not qualified | Not qualified |
| Operating Temperature | -40C to +85C | -40C to +85C | -40C to +85C | 0C to +70C | -40C to +85C |
| Switch Fabric Bandwidth | 1.4 Gbps | 1.4 Gbps | 1.4 Gbps | 1.4 Gbps | 1.0 Gbps |
| VLAN Groups | 16 (IEEE 802.1Q) | 16 (IEEE 802.1Q) | 16 (IEEE 802.1Q) | 16 (IEEE 802.1Q) | 16 (IEEE 802.1Q) |
| Unit Price (qty 1) | $8.42 | $9.10 (estimate) | $8.20 (estimate) | $7.80 (estimate) | $6.50 (estimate) |
Diferensiator Kunci
- AEC-Q100 qualified with full -40C to +85C industrial temperature range (vsKSZ8895FQX)
- Five integrated 10/100 PHYs eliminate external PHY ICs (vsKSZ8995MA)
- Full 1.4 Gbps non-blocking switch fabric with QoS priority queuing (vsKSZ8863RLLI)
Catatan Desain
The 128-pin PQFP package (14x20 mm body, 0.5 mm pitch) requires a four-layer PCB minimum for proper return-path integrity on the MII/RMII bus. Estimated: signal trace impedance should be 50 ohm single-ended with continuous ground reference plane beneath all MII/RMII traces. Each port's differential pair (TX_P/N, RX_P/N) should be routed as 100 ohm differential with intra-pair length matching within 2 mm. Place a 10 uF tantalum plus 0.1 uF ceramic decoupling capacitor within 3 mm of every VDDIO pin.
Power sequencing is critical for the KSZ8895MQXI: VDDIO (3.3 V) must ramp up before the internal 1.8 V LDO output (VDDCORE) is observed by the internal logic. The integrated LDO requires a 10 uF bulk plus 0.1 uF ceramic on VDDCORE (pin 11, 72) for stability. Estimated: total power consumption at full 100 Mbps load on all five ports is approximately 825 mW (250 mA at 3.3 V), so design the 3.3 V rail for at least 400 mA peak with 100 mV maximum ripple.
The TEST pin (pin 64) must be tied directly to GND in the application circuit - leaving it floating may cause factory-test mode to engage and disrupt normal switch operation. The RESETN pin (pin 63) requires an external 10 kohm pull-up to VDDIO and a 100 nF capacitor to GND for proper power-on-reset timing per the datasheet. Estimated: leaving the crystal load capacitors off XTAL1/XTAL2 (pins 73/74) is a common cause of link-up failure - use a 25 MHz crystal with 18 pF load capacitors matching the crystal manufacturer's CL specification.
For the MII host interface running at 25 MHz, route all MII data/clock signals on the same PCB layer with length-matched traces (within 10 mm of the clock). Keep MII signals at least 3 mm away from the Port 1-5 PHY differential pairs to avoid coupling of the 25 MHz harmonics into the analog front-end. Estimated: at 100 Mbps operation, the analog TX/RX pairs produce 31 MHz fundamental; route these on the top layer over a continuous ground plane with via stitching every 25 mm around the perimeter.