MCP3426A3-E/MS - 16-Bit Dual-Channel ADC | Microchip
部品番号: MCP3426A3-E/MS ✓ 生産中MCP3426A3-E/MS 概要
An analog-to-digital converter, or ADC, converts an analog input voltage into a digital value that a microcontroller, embedded controller, or data-acquisition system can process. The MCP3426 belongs to the sigma-delta ADC family, where the analog input is continuously sampled and converted through delta-sigma modulation and digital filtering. This architecture is commonly used for relatively slow, precision-oriented measurements that do not require high-frequency sampling.
The MCP3426A3-E/MS combines a 16-bit conversion resolution with two analog input channels and a 15 sps conversion rate. This operating point is suited to slowly varying sensor signals where high resolution and noise-limited measurement are more important than rapid sampling. Operation from a 2.7 V to 5.5 V digital supply supports both 3.3 V and 5 V system architectures, while the industrial temperature rating allows deployment across a broad range of ambient conditions.
The device uses a sigma-delta conversion architecture that separates analog measurement from digital filtering. In a typical circuit, external analog components condition each input before it reaches the converter, while a microcontroller reads the converted result through a serial interface. The -40 °C to +125 °C operating range and 8-MSOP surface-mount construction make the device suitable for compact industrial, instrumentation, and embedded measurement systems.
Typical uses include temperature monitoring, pressure and strain-sensor acquisition, potentiometer position measurement, and low-frequency process-control inputs. These applications benefit from the 16-bit resolution when the measured signal changes slowly and system noise has been controlled through shielding, grounding, filtering, and careful PCB layout.
The principal design consideration is the relationship between input accuracy, analog reference quality, and the conversion cycle. The 15 sps rate should be matched to the physical signal bandwidth; oversampling a fast or noisy signal cannot recover information that the input network has already filtered out. Reference and supply bypassing must also be placed close to the device pins.
This product page combines the MCP3426A3-E/MS electrical characteristics, package information, pricing references, same-family drop-in alternatives, and application-focused engineering guidance to support component selection, PCB planning, and BOM qualification.
ドロップイン代替品: MCP3426A3-E/MS — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: MCP3426A3-E/MS (同一形状・フットプリント) — 相違点: Package, Differential Input Range, Operating Temperature Range, ADC Type, Input Architecture.
MCP3426A7-E/MS
✅ ドロップイン価格はお問い合わせください
データシートを見る →MCP3426A3T-E/MS
✅ ドロップイン📋 参考代替品(カタログ未掲載)
MCP3426A5-E/MS
✅ ドロップイン価格はお問い合わせください
データシートを見る →MCP3426A0-E/MS
✅ ドロップイン価格はお問い合わせください
データシートを見る →MCP3426A1-E/MS
✅ ドロップイン価格はお問い合わせください
データシートを見る →MCP3426A6-E/MS
✅ ドロップイン価格はお問い合わせください
データシートを見る →MCP3426A3-E/MS 最大定格&電気的特性
| ADC Type | Sigma-delta analog-to-digital converter |
| 分解能 | 16 bit |
| Number of Input Channels | 2 channels |
| Conversion Rate | 15 samples/s |
| Digital Supply Voltage | 2.7 V to 5.5 V |
| 動作温度範囲 | -40 °C to +125 °C |
| パッケージ | 8-MSOP, 3.00 mm width |
| 実装タイプ | Surface mount |
| Number of Terminals | 8 terminals |
| Terminal Form | Gull wing |
| Package Shape | Square |
| Automotive Classification | Automotive temperature grade |
| RoHS ステータス | unknown |
| REACH Status | unknown |
MCP3426A3-E/MS square ピン配置ガイド
MCP3426A3-E/MS (square パッケージ) のピン配置。 このアナログコンポーネントは、入力、出力、および電源ピンを備えています。オフセットナル、補償、イネーブルピンの設定については、メーカーのデータシートを参照してください。信号調整やアンプ回路に最適です。
詳細なピン配置データはありません: MCP3426A3-E/MS.
詳細は データシート をご参照ください。
主な用途
MCP3426A3-E/MS の用途: 6 件s: Industrial Temperature Sensing, Pressure and Strain Measurement, Battery-Powered Instrumentation, Process Control and Monitoring, Precision Potentiometer Readout, Environmental and Sensor Monitoring.
Industrial Temperature Sensing
The MCP3426A3-E/MS fits slow industrial temperature measurements because it combines a 16-bit conversion resolution with a 15 samples-per-second rate and an operating range of -40 °C to +125 °C. Place the converter in the measurement path after a conditioned bridge or thermistor interface, then read the digital result through its serial interface. The 15 sps rate is appropriate for thermal signals that change gradually rather than high-speed transients. Its 2.7 V to 5.5 V digital supply also permits integration into both 3.3 V and 5 V controller platforms.
おすすめ
Pressure and Strain Measurement
The MCP3426A3-E/MS can digitize conditioned pressure-cell or strain-gauge outputs where measurement accuracy over time matters more than acquisition bandwidth. Its 16-bit format provides 65,536 numerical levels, while the 15 samples-per-second rate is appropriate for slow pressure loading, valve position, and mechanical deformation. The dual-input arrangement can monitor a sensor signal and a reference channel when the application requires drift or offset compensation. Signal conditioning, input filtering, and reference stability remain central to preserving the converter's useful resolution.
おすすめ
Battery-Powered Instrumentation
The MCP3426A3-E/MS is suitable for portable instrumentation that records slowly changing physical quantities. Its 15 samples-per-second operating point avoids the data volume associated with a fast converter, while the 2.7 V minimum digital supply supports low-voltage embedded systems. The device can capture conditioned outputs from resistive, capacitive, or bridge-based sensors in a compact 8-MSOP footprint. Low-power designs should still evaluate the complete current-consumption profile and disable or duty-cycle the acquisition chain when longer battery life is required.
おすすめ
Process Control and Monitoring
The MCP3426A3-E/MS supports supervisory process measurements such as tank level, valve position, and slowly changing line pressure. Two analog channels allow a controller to acquire two related process variables, and the 16-bit result format is useful when the measured quantity has a narrow engineering range. The 15 samples-per-second rate provides repeated readings for control and alarm logic without the overhead of high-rate acquisition. Industrial implementation should place input conditioning close to the converter and maintain a clean reference and supply network.
おすすめ
Precision Potentiometer Readout
The MCP3426A3-E/MS is appropriate for high-resolution position readout from a potentiometer or resistive divider where the mechanical movement is slow. Sixteen-bit resolution produces a fine digital increment across the selected measurement range, while the 15 samples-per-second rate supports continuous monitoring and averaging rather than only a single static reading. The 8-MSOP package helps reduce board area in compact control panels and test fixtures. Mechanical contact resistance, wiring noise, and excitation stability should be included in the error budget.
おすすめ
Environmental and Sensor Monitoring
The MCP3426A3-E/MS can be used in environmental monitoring systems that measure humidity, light, pressure, or chemical-sensor outputs after analog conditioning. Its dual-channel architecture can combine a primary sensor with a reference or second probe, while the 15 samples-per-second rate is well matched to slowly varying environmental conditions. The 2.7 V to 5.5 V digital supply range supports embedded monitoring electronics, and the -40 °C to +125 °C operating range supports industrial deployments. Field accuracy still depends on sensor calibration and protection from condensation or transient damage.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: MCP3426A3-E/MS — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | MCP3426A7-E/MS | MCP3426A3T-E/MS | MCP3426A5-E/MS | MCP3426A0-E/MS | MCP3426A1-E/MS |
|---|---|---|---|---|---|---|
| Brand | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology |
| Package | 8-MSOP | 8-MSOP | 8-MSOP | 8-MSOP | 8-MSOP | 8-MSOP |
| ADC Resolution | 16 bit | 16 bit | 16 bit | 16 bit | 16 bit | 16 bit |
| Number of Input Channels | 2 channels | 2 channels | 2 channels | 2 channels | 2 channels | 2 channels |
| Conversion Architecture | Sigma-delta | Sigma-delta | Sigma-delta | Sigma-delta | Sigma-delta | Sigma-delta |
| Mounting Type | Surface mount | Surface mount | Surface mount | Surface mount | Surface mount | Surface mount |
主な差別化要因
- Defined 15 samples-per-second operating point (vs MCP3426A5-E/MS)
- Exact electrical configuration match with the same package (vs MCP3426A3T-E/MS)
- Dual-channel measurement in a compact 8-MSOP footprint (vs MCP3426A0-E/MS)
- Industrial temperature coverage (vs MCP3426A7-E/MS)
設計ノート
Place the device's supply bypass and reference-decoupling components directly beside their corresponding pins, with short, low-inductance traces. Keep the analog input routing away from digital clock and serial-interface traces. The 8-MSOP footprint has limited lead spacing, so input and ground routing should follow the pin-description table and recommended layout in the Microchip Technology datasheet rather than relying on a generic MSOP template.
The 15 samples-per-second conversion rate is appropriate for slowly varying signals, but it does not remove the need for an input filter. Select filter and settling components for the source impedance and required bandwidth, and allow the analog front end to settle before interpreting a result as accurate. Differential, common-mode, and reference error should be evaluated together because the nominal 16-bit resolution does not guarantee 16-bit total system accuracy.
Do not substitute an 8-TSSOP footprint for the specified 8-MSOP package without checking the manufacturer land pattern and pin dimensions. Also confirm the selected family member's conversion rate and operating mode before using an A-series variant as a replacement. A shared package reduces PCB work, but it does not replace verification of timing, configuration registers, reference behavior, and acquisition sequencing.
The MCP3426A3-E/MS supports a 2.7 V to 5.5 V digital supply, but the complete system still needs clean analog and reference rails. Verify that supply ripple, digital switching activity, and reference variation do not dominate the converter's usable measurement resolution. For portable systems, calculate the average acquisition energy using the converter's measured operating current, duty cycle, and the number of readings required by the application.
コンプライアンス情報
The device is identified as automotive temperature grade, but AEC-Q100 qualification and environmental compliance declarations require confirmation from the manufacturer.