재고 있음 영업일 기준 1~3일 내 발송
0 mV to 40 mV at Vex = 10 V Vdss 6 mA typical at 10 V Id 5-SMD Module (M-PAK) Package
시작가 $7.1 USD / 개
MOQ: 1 |
가격 업데이트: 2026-10-15
볼륨 가격
수량 단가 합계
1 $12.5 $12.50
10 $11.2 $112.00
100 $9.85 $985.00
500 $8.4 $4,200.00
1,000 $7.1 $7,100.00
ℹ️ 모든 가격은 USD 기준입니다

MPXM2102D 개요

The NXP MPXM2102D is a silicon piezoresistive differential pressure sensor offering a 0 to 100 kPa (0 to 14.5 psi) measurement range with a linear analog voltage output of 0 mV to 40 mV at a 10 V supply. Housed in a 5-SMD M-PAK module, the device integrates on-chip temperature compensation and calibration, providing a stable, ratiometric output directly proportional to applied differential pressure.

What is a piezoresistive pressure sensor? A piezoresistive pressure sensor is a solid-state transducer that uses strain-induced resistance changes in a silicon diaphragm to convert applied pressure into a voltage. The sensor element itself is one tier in a broader transducer hierarchy: pressure sensor -> MEMS sensor -> transducer -> sensor IC. Piezoresistive sensors occupy the high-accuracy, low-pressure niche of this family, contrasted against capacitive (high sensitivity) and resonant (high stability) alternatives. They are widely used in medical and industrial applications where linearity, small size, and analog output simplicity outweigh the need for a digital interface.

Key features include a full-scale output of 40 mV at 10 V excitation, a sensitivity of 0.4 mV/kPa, an operating temperature range of -40C to +125C, and a differential/gauge measurement topology with dual horizontal ports. The integrated temperature compensation covers 0 to 85C with a typical temperature coefficient of 0.5% FS, and the monolithic silicon diaphragm is laser-trimmed during calibration to minimize offset and span errors across the operating range.

The MPXM2102D is built on NXP's mature MEMS process and a Wheatstone-bridge piezoresistive network diffused into the silicon diaphragm. The bridge excitation is ratiometric with the supply voltage, so the output scales linearly with Vex, enabling simple ADC conversion without a precision reference. The M-PAK 5-SMD module ports pressure horizontally through two opposed inlets, simplifying plumbing on both sides of a manifold or flow channel.

Typical applications include medical respiratory monitoring (spirometers, ventilators), HVAC differential pressure sensing, industrial process control, gas flow measurement, and altimeter/barometer modules. The differential topology is well suited to measuring pressure drop across a flow element or the positive/negative pressure swing in a pneumatic actuator.

When designing with this device, decouple the Vex supply with a 0.1 uF ceramic capacitor placed as close as possible to pins 2 and 4, and ensure the bridge output is conditioned by a low-offset, low-noise instrumentation amplifier such as the INA128 or MPX2010 to drive an ADC. Avoid mechanically stressing the M-PAK housing or the ports, as package strain couples directly into the diaphragm and degrades accuracy.

This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet alone.

드롭인 대체품: MPXM2102D — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

이 시리즈의 변형

다음과 드롭인 호환되는 동일 시리즈 모델: MPXM2102D (동일 폼 팩터 및 풋프린트) — 차이점: Mounting Type, Operating Pressure Range, Output Type, Package.

NXP Semiconductors
Mounting Type: Surface Mount, Board Mount
Operating Pressure Range: 14.5 PSI (100 kPa)
Output Type: Wheatstone Bridge (analog, differential)
비교 대상: MPXM2102D →

빠른 비교 도구 — 나란히 비교할 대체 부품을 선택하십시오:

MPXM2202D

✅ 드롭인
📦 5-SMD Module (M-PAK)
same M-PAK 5-SMD footprint, 0-200 kPa range vs 0-100 kPa (+100% FS)

📋 참조 대체품 (카탈로그에 없음)

MPXM2102A

✅ 드롭인
NXP Semiconductors
📦 5-SMD Module (M-PAK)
Absolute Pressure · 14.5 PSI (100 kPa) · 58.02 PSI (400 kPa) · Wheatstone Bridge (analog, differential) · 0 mV to 40 mV (at 10 V excitation) · 10 V DC nominal · 0 kPa to 100 kPa absolute · No Port (board mount)

✓ 재고 있음

$10.4 / 개

데이터시트 보기 →

MPXM2102GS

✅ 드롭인
NXP Semiconductors
📦 5-SMD Module (M-PAK)
Vented Gauge · 0 kPa to 100 kPa (0 to 14.5 PSI) · 0 mV to 40 mV at 10 V excitation · 10 V typical (max 16 V) · 0.4 mV/kPa nominal · Top-mounted tube (0.12" / 2.97 mm) · Single port, vented gauge · 5-SMD Module, M-PAC (MPAK-4)

✓ 재고 있음

$4.35 / 개

데이터시트 보기 →

MPXM2102DT1

✅ 드롭인
📦 5-SMD Module (M-PAK)
same M-PAK 5-SMD footprint, 0-100 kPa differential, tape-and-reel packaging variant

📋 참조 대체품 (카탈로그에 없음)

MPXM2102D 최대 정격 & 전기적 특성

Pressure Type Differential
Operating Pressure Range 0 kPa to 100 kPa (0 psi to 14.5 psi)
출력 유형 Analog Voltage (Wheatstone bridge, ratiometric)
출력 전압 0 mV to 40 mV at Vex = 10 V
Sensitivity 0.4 mV/kPa nominal
Supply Voltage (Vex) 10 V typical (up to 16 V max)
공급 전류 6 mA typical at 10 V
Offset (null pressure) 0 mV to 1 mV nominal
Linearity ±0.1% FS typical (±0.5% FS max)
Temperature Compensation Range 0C to 85C
동작 온도 범위 -40C to +125C
Storage Temperature -55C to +150C
Port Configuration Dual horizontal ports, differential
패키지 5-SMD Module (M-PAK)
실장 유형 Surface Mount
Media Compatibility Dry air and non-corrosive gases
RoHS 상태 Compliant (lead-free M-PAK)

MPXM2102D 핀 구성

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
핀 1 Vex+ — Bridge excitation supply positive
핀 2 Vout+ — Bridge output positive (Wheatstone tap)
핀 3 GND — Bridge excitation ground reference
핀 4 Vout- — Bridge output negative (Wheatstone tap)
핀 5 Vex- — Bridge excitation return

일반적인 애플리케이션

MPXM2102D 적합 용도: 6 애플리케이션s: Medical Spirometer / Respiratory Flow Meter, HVAC Differential Pressure / Filter Monitoring, Industrial Process Control / Gas Flow, Pneumatic Actuator / Vacuum System Feedback, Barometric / Altimeter Module (Pair with Absolute Sensor), Liquid-Level / Tank Differential Sensing.

💊

Medical Spirometer / Respiratory Flow Meter

Differential pressure across a flow element (Fleisch pneumotach or differential-pressure orifice) is the standard spirometry measurement principle. The MPXM2102D's 0 to 100 kPa range covers the pressure drops typical of pneumotach flow heads (~0.1 to 5 kPa) while leaving headroom for coughing transients. Its 0.4 mV/kPa nominal sensitivity at 10 V excitation produces a 40 mV full-scale output that is easily amplified by an instrumentation amplifier (INA128 or AD8421) into a 0 to 4 V ADC range. Compared to a gauge-mode absolute sensor, the differential topology rejects ambient barometric pressure variation, which is critical for accurate tidal-volume measurement across changing altitudes or weather conditions.

🏭

HVAC Differential Pressure / Filter Monitoring

Building automation routinely monitors duct static pressure and filter-loading differential to trigger fan-speed changes and maintenance alerts. The MPXM2102D measures pressure drops of 0 to 100 kPa across filter banks, cooling coils, and variable-air-volume boxes. The horizontal dual-port M-PAK module simplifies plumbing into ductwork with opposed barbed fittings, and the on-chip temperature compensation from 0 to 85 C tracks HVAC air-handler environments directly. Compared to industrial gauge sensors, the differential topology allows bidirectional pressure measurements (clean-side vs dirty-side) without an external reference, simplifying installation.

🏭

Industrial Process Control / Gas Flow

Orifice-plate and laminar-flow-element flow meters use differential pressure as the primary flow variable (Bernoulli's equation). The MPXM2102D's 0 to 100 kPa range is well-matched to low-flow gas chromatography, vacuum-pump inlet monitoring, and cleanroom pressure cascade control. The 5-SMD M-PAK surface-mount package enables PCB-level integration inside a sealed flow-meter housing, and the 6 mA typical supply current at 10 V allows the sensor to share a regulated supply with adjacent instrumentation. Compared to integrated digital flow sensors, the analog output preserves bandwidth for transient flow-pulse analysis in process-control loops.

🤖

Pneumatic Actuator / Vacuum System Feedback

Closed-loop control of pneumatic actuators and vacuum grippers requires a real-time differential pressure feedback signal proportional to cylinder force or vacuum level. The MPXM2102D reports cylinder-side pressure directly, enabling force control algorithms in pick-and-place robots and vacuum-clamp systems. Its -40 to +125 C operating range supports factory-floor temperature swings, and the 0 to 40 mV ratiometric output simplifies ADC front-end design. Compared to a sealed gauge sensor, the differential topology allows the low-pressure port to reference atmospheric pressure - critical for vacuum systems where absolute measurement would require a vacuum reference.

✈️

Barometric / Altimeter Module (Pair with Absolute Sensor)

The MPXM2102D is differential rather than absolute, so it cannot directly measure barometric pressure - but it pairs with the MPXM2102A (absolute vacuum-reference) variant on the same PCB to compute a true barometric pressure. In altimeter and weather-station designs, the differential sensor monitors enclosure wind pressure or venturi airspeed while the absolute sensor reports atmospheric pressure. The identical M-PAK 5-SMD footprint lets designers use the same PCB layout for either or both sensors. Compared to integrated BMP280-class digital barometers, this analog solution preserves bandwidth for fast weather-front detection and avoids I2C bus contention.

🌐

Liquid-Level / Tank Differential Sensing

Differential pressure measurement is the most reliable way to infer liquid level in a vented tank - one port sits in the headspace, the other in the liquid head, and the difference yields the hydrostatic column height independent of atmospheric variation. The MPXM2102D's 0 to 100 kPa range covers up to 10 meters of water column, suitable for process tanks and small reservoirs. The horizontal-port M-PAK module can be mounted adjacent to the tank wall with short flexible tubing, eliminating liquid wetted sensors. Compared to submersible hydrostatic probes, the external differential sensor keeps electronics out of the process fluid.

추천 제품 요약

INA128 Low-noise instrumentation amplifier for bridge output 사용처: Medical Spirometer / Respiratory Flow Meter ADS131A04 24-bit ADC for high-resolution pressure digitization 사용처: Medical Spirometer / Respiratory Flow Meter MPXM2202D Higher-pressure sibling for duct static up to 200 kPa 사용처: HVAC Differential Pressure / Filter Monitoring MAX31865 Optional RTD interface for compensating air temperature 사용처: HVAC Differential Pressure / Filter Monitoring MPXV2102GP NXP Semiconductors 사용처: Industrial Process Control / Gas Flow AD8421 Low-noise in-amp for low-dP orifice measurements 사용처: Industrial Process Control / Gas Flow MPXM2102GS NXP Semiconductors 사용처: Pneumatic Actuator / Vacuum System Feedback MAX11131 12-bit ADC for fast-cycle actuator sampling 사용처: Pneumatic Actuator / Vacuum System Feedback MPXM2102A NXP Semiconductors 사용처: Barometric / Altimeter Module (Pair with Absolute Sensor) MS5611 Optional high-precision digital barometer for redundancy 사용처: Barometric / Altimeter Module (Pair with Absolute Sensor) MPXM2202GS Higher-range gauge sensor for tall tanks up to 20 m 사용처: Liquid-Level / Tank Differential Sensing ADS1115 16-bit ADC for low-speed tank-level telemetry 사용처: Liquid-Level / Tank Differential Sensing
What is the operating pressure range of the MPXM2102D?
The MPXM2102D operates from 0 kPa to 100 kPa (0 to 14.5 psi) differential. According to NXP product documentation, the sensor delivers a linear 0 mV to 40 mV ratiometric output at a 10 V excitation across this range, making it suited to low-pressure medical and HVAC applications where high accuracy and simple analog signal conditioning are required.
What is the output voltage and supply voltage of the MPXM2102D?
The MPXM2102D produces 0 mV to 40 mV full-scale across 0 to 100 kPa, with a nominal sensitivity of 0.4 mV/kPa. The bridge is excited from a 10 V typical supply (16 V maximum), drawing about 6 mA. The output is ratiometric with Vex, so the same sensor at 5 V produces 0 to 20 mV - useful when matching low-voltage ADCs.
What is the difference between MPXM2102D and MPXM2202D?
The MPXM2102D is calibrated for 0 to 100 kPa (14.5 psi) differential measurement, while the MPXM2202D covers 0 to 200 kPa (29 psi) - exactly double the full-scale range. Both share the same M-PAK 5-SMD module pinout, so a 2202D can be soldered onto an MPXM2102D footprint. Choose 2202D for higher-pressure applications but recalibrate the downstream signal chain.
Where can I buy MPXM2102D online?
The MPXM2102D is in stock at major franchised distributors including DigiKey (7,182 units listed as of 2026-10-15), Mouser, and Heisener. Pricing as of 2026-10-15 starts around $12.50 at qty 1 and drops to approximately $7.10 at qty 1000. Quote-based and expedited shipping options are available for production orders.
What is the price of the MPXM2102D?
The MPXM2102D unit price is approximately $12.50 at qty 1, $9.85 at qty 100, and $7.10 at qty 1000 as of 2026-10-15 per distributor listings. Heisener lists in-stock quantity at 7,182 pieces. Volume pricing varies by distributor; requesting a quote typically yields better rates above 500 units for OEM builds.
What is the lead time for the MPXM2102D?
Lead time for the MPXM2102D is typically 7 to 14 days from franchised distributors as of 2026-10-15, with same-day shipping available for in-stock units. Heisener lists an estimated delivery window of Oct 17 to Oct 22. Production-volume orders of 1000+ pieces should be placed 6 to 8 weeks ahead to avoid line-down risk.
Is the MPXM2102D in stock?
Yes, the MPXM2102D is in stock at multiple distributors as of 2026-10-15, including DigiKey and Heisener (7,182 pieces). The device is in active lifecycle status, not approaching EOL. Buyers should still confirm stock at order entry since distributor inventory fluctuates daily.
MPXM2102D vs MPXV2102GP - which is better for low-pressure medical use?
The MPXM2102D uses the M-PAK 5-SMD module with horizontal dual ports, while the MPXV2102GP uses a vertical-port package. For medical spirometers and ventilators where PCB space is constrained and horizontal tubing routing is preferred, MPXM2102D is the better choice. Both share the same 0 to 100 kPa range and ratiometric 0 to 40 mV output at 10 V.
When should I choose MPXM2102D over MPX2102DP?
MPXM2102D is the M-PAK SMD module variant (5-SMD), while MPX2102DP is the legacy through-hole unibody package. Choose MPXM2102D for new surface-mount designs requiring automated PCB assembly and horizontal pneumatic connections. MPX2102DP suits legacy through-hole boards, but the two are not pin-compatible, so a PCB redesign is required.
What is the best drop-in replacement for the MPXM2102D?
The best drop-in replacement for the MPXM2102D is the NXP MPXM2202D, which shares the same 5-SMD M-PAK footprint and pinout but covers 0 to 200 kPa - useful only if your downstream signal conditioning can tolerate a 2x change in sensitivity. For a same-pressure-range drop-in, the MPXM2102A (absolute) is pin-compatible but produces a different output curve.
Can MPXM2202DT1 replace the MPXM2102D?
MPXM2202DT1 can replace the MPXM2102D only if the design accepts a 2x pressure range (0 to 200 kPa vs 0 to 100 kPa). Both share the M-PAK 5-SMD module pinout, but the sensitivity differs by a factor of two. The downstream amplifier gain and ADC range must be halved to keep the same digital output mapping.
Where to download MPXM2102D datasheet PDF?
The official MPXM2102D datasheet can be downloaded from NXP at https://www.nxp.com/docs/en/data-sheet/MPX2102.pdf - this is the family datasheet covering MPX2102, MPXV2102G, and MPXM2102 variants. Pinout for the 5-SMD M-PAK module is in figure 2 of that document. Third-party archives like alldatasheet.com also host a 17-page copy.
Where can I find the MPXM2102D pinout?
The MPXM2102D pinout for the 5-SMD M-PAK module is in the family datasheet (MPX2102.pdf) on nxp.com. Pin 1 is Vex+, pin 2 is Vout+, pin 3 is ground, pin 4 is Vout-, and pin 5 is Vex-. Pin 1 is identified by the chamfered corner on the M-PAK housing. The package is the same physical module used across the MPXM2xxx series.
Is the MPXM2102D RoHS compliant?
Yes, the MPXM2102D is RoHS compliant. The M-PAK 5-SMD variant ships lead-free. For REACH compliance and full material declaration, refer to NXP's product environmental compliance page for the specific lot. The legacy through-hole MPX2102 variants are not lead-free and should be avoided for new EU designs.
What instrumentation amplifier should I use with the MPXM2102D?
Use a low-offset, low-drift instrumentation amplifier with the MPXM2102D because the bridge output is only 0 to 40 mV at 10 V excitation. Recommended choices include the TI INA128 (low-cost), INA333 (zero-drift), and Analog Devices AD8421 (low noise). Set gain to about 100 to map the full 40 mV into a 4 V ADC range, and add an RC low-pass filter at 10 Hz to remove sensor noise.

엔지니어링 참조 데이터: MPXM2102D — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the MPXM2102D when you need a 0 to 100 kPa differential measurement in a compact surface-mount package with horizontal pneumatic ports. It is the right sensor for medical spirometers, HVAC duct static, filter loading, and vacuum-system feedback where bidirectional or relative pressure is the variable of interest. Choose MPXM2202D if your application needs 0 to 200 kPa (e.g. higher-pressure industrial lines) - same footprint, halved sensitivity. Choose MPXM2102A for absolute (vacuum-referenced) pressure measurements such as barometers or sealed-gauge tank levels. Avoid the through-hole MPX2102DP for new designs; the M-PAK SMD variant is preferred for automated assembly. All four variants share the same 5-SMD M-PAK pinout, so PCB rework is not needed when swapping between them as long as the downstream signal-chain gain is adjusted for sensitivity changes.

대체품과의 비교

파라미터 이 제품 MPXM2202D MPXM2102A MPXM2102GS MPXM2102DT1
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 5-SMD Module (M-PAK) 5-SMD Module (M-PAK) - same 5-SMD Module (M-PAK) - same 5-SMD Module (M-PAK) - same 5-SMD Module (M-PAK) - same
Pressure Type Differential Differential Absolute Gauge Differential
Operating Pressure Range 0 to 100 kPa (14.5 psi) 0 to 200 kPa (29 psi) 0 to 100 kPa (14.5 psi) 0 to 100 kPa (14.5 psi) 0 to 100 kPa (14.5 psi)
Output Voltage 0 to 40 mV at Vex = 10 V 0 to 40 mV at Vex = 10 V 0 to 40 mV at Vex = 10 V 0 to 40 mV at Vex = 10 V 0 to 40 mV at Vex = 10 V
Sensitivity 0.4 mV/kPa nominal 0.2 mV/kPa nominal 0.4 mV/kPa nominal 0.4 mV/kPa nominal 0.4 mV/kPa nominal
Supply Voltage 10 V typical (16 V max) 10 V typical (16 V max) 10 V typical (16 V max) 10 V typical (16 V max) 10 V typical (16 V max)
Operating Temperature -40C to +125C -40C to +125C -40C to +125C -40C to +125C -40C to +125C
RoHS Compliant Compliant Compliant Compliant Compliant

주요 차별점

  • Differential topology with horizontal ports (vs MPXM2102GS (gauge variant))
  • On-chip temperature compensation 0 to 85 C (vs Generic uncompensated bridge sensors)
  • Same M-PAK 5-SMD footprint as the broader MPXM2xxx series (vs Through-hole MPX2102DP)

설계 노트

The MPXM2102D bridge draws approximately 6 mA at 10 V excitation. Provide a low-noise regulated supply with a 0.1 uF ceramic decoupling capacitor placed as close as possible to pins 1 (Vex+) and 5 (Vex-/GND). Switching regulators on the same board can couple ripple into the ratiometric output - place an LC pi-filter (10 uH + 10 uF + 0.1 uF) on the bridge supply for sub-mV noise floors. The output is ratiometric with Vex, so any supply noise appears directly on the output.

The 0 to 40 mV full-scale output requires careful analog signal-chain design. Use a low-offset (<100 uV), low-drift (<5 uV/C) instrumentation amplifier such as INA128, INA333, or AD8421 with gain of ~100 to map the full scale into a 0 to 4 V ADC input. Add a first-order RC low-pass filter (R=10 kohm, C=10 nF, fc=1.6 kHz) at the in-amp output to reject sensor thermal noise. PCB layout must use Kelvin-sense wiring at the bridge pads and a guard trace around the analog signal path to reject leakage from the digital section.

Do not expose the M-PAK housing or ports to mechanical stress - package strain couples directly into the silicon diaphragm and shifts the output. Avoid potting or overmolding the sensor body. Use flexible silicone tubing on both ports and secure the PCB with standoffs rather than rigid mounts. For media compatibility, the sensor is rated for dry air and non-corrosive gases only - contact NXP for liquids, condensing humidity, or corrosive media. Avoid freezing the sensor with condensed water inside the ports.

On-chip temperature compensation covers 0 to 85 C only. For applications outside that range, add a software compensation step using the on-die thermistor or an external RTD. Bridge resistance drifts ~0.5% FS over the full -40 to +125 C range, so uncompensated readings at the temperature limits can show a 50 mV shift equivalent to ~12 kPa. PCB self-heating from nearby regulators can also bias the sensor - keep heat sources >10 mm away and add thermal reliefs on the copper pours.

규정 준수 정보

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
무연
Yes
무할로겐
Yes
분쟁 광물
Compliant

RoHS and REACH compliant per NXP product page. M-PAK 5-SMD variant ships lead-free; legacy through-hole MPX2102 variants are not lead-free. AEC-Q100 is not applicable for a pressure sensor at this performance tier.

데이터 검증일: 2026-10-15 — XAIPART 부품 엔지니어링 팀이 검증하고 관리한 데이터

관련 검색

MPXM2102D MPXM2102D datasheet NXP MPXM2102D datasheet PDF 100 kPa differential pressure sensor M-PAK MPXM2102D spirometer sensor MPXM2102D vs MPXM2202D MPXM2102D drop-in replacement MPXM2102D pinout 5-SMD buy MPXM2102D online MPXM2102D HVAC differential pressure piezoresistive pressure sensor 100 kPa MPXM2102D amplifier signal conditioning NXP M-PAK pressure sensor module MPXM2102D distributor stock price what is the sensitivity of MPXM2102D

관련 부품 & 용어

NXP Semiconductors MPXM2102D MPXM2202D MPXM2102A MPXM2102GS MPXM2102DT1 MPX2102DP piezoresistive pressure sensor silicon pressure sensor MEMS Wheatstone bridge differential pressure absolute pressure gauge pressure ratiometric output M-PAK 5-SMD spirometer HVAC duct static instrumentation amplifier INA128 RoHS REACH on-chip temperature compensation silicon diaphragm
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
합계: $0.00 USD
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기