MPXM2102D - 100kPa Differential Pressure Sensor, M-PAK | NXP
Артикул: MPXM2102D ✓ Активен| Кол-во | Цена за ед. | Итого |
|---|---|---|
| 1 | $12.5 | $12,50 |
| 10 | $11.2 | $112,00 |
| 100 | $9.85 | $985,00 |
| 500 | $8.4 | $4.200,00 |
| 1.000 | $7.1 | $7.100,00 |
MPXM2102D Обзор
What is a piezoresistive pressure sensor? A piezoresistive pressure sensor is a solid-state transducer that uses strain-induced resistance changes in a silicon diaphragm to convert applied pressure into a voltage. The sensor element itself is one tier in a broader transducer hierarchy: pressure sensor -> MEMS sensor -> transducer -> sensor IC. Piezoresistive sensors occupy the high-accuracy, low-pressure niche of this family, contrasted against capacitive (high sensitivity) and resonant (high stability) alternatives. They are widely used in medical and industrial applications where linearity, small size, and analog output simplicity outweigh the need for a digital interface.
Key features include a full-scale output of 40 mV at 10 V excitation, a sensitivity of 0.4 mV/kPa, an operating temperature range of -40C to +125C, and a differential/gauge measurement topology with dual horizontal ports. The integrated temperature compensation covers 0 to 85C with a typical temperature coefficient of 0.5% FS, and the monolithic silicon diaphragm is laser-trimmed during calibration to minimize offset and span errors across the operating range.
The MPXM2102D is built on NXP's mature MEMS process and a Wheatstone-bridge piezoresistive network diffused into the silicon diaphragm. The bridge excitation is ratiometric with the supply voltage, so the output scales linearly with Vex, enabling simple ADC conversion without a precision reference. The M-PAK 5-SMD module ports pressure horizontally through two opposed inlets, simplifying plumbing on both sides of a manifold or flow channel.
Typical applications include medical respiratory monitoring (spirometers, ventilators), HVAC differential pressure sensing, industrial process control, gas flow measurement, and altimeter/barometer modules. The differential topology is well suited to measuring pressure drop across a flow element or the positive/negative pressure swing in a pneumatic actuator.
When designing with this device, decouple the Vex supply with a 0.1 uF ceramic capacitor placed as close as possible to pins 2 and 4, and ensure the bridge output is conditioned by a low-offset, low-noise instrumentation amplifier such as the INA128 or MPX2010 to drive an ADC. Avoid mechanically stressing the M-PAK housing or the ports, as package strain couples directly into the diaphragm and degrades accuracy.
This page synthesizes distributor pricing, drop-in alternatives, and practical design notes not found in the manufacturer datasheet alone.
Аналоги без доработки для MPXM2102D — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.
Варианты в этой серии
Модели той же серии, совместимые без доработки с MPXM2102D (тот же форм-фактор и посадочное место) — отличается по Operating Pressure Range, Mounting Type, Operating Temperature, Output Type, Output Voltage.
Инструмент быстрого сравнения — выберите альтернативные компоненты для сравнения бок о бок:
MPXM2202D
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
MPXM2102A
✅ Прямая замена✓ В наличии
$10.4 / шт.
Открыть даташит →MPXM2102GS
✅ Прямая замена✓ В наличии
$4.35 / шт.
Открыть даташит →MPXM2102DT1
✅ Прямая замена📋 Справочный аналог (нет в каталоге)
MPXM2102D Максимальные параметры и электрические характеристики
| Pressure Type | Differential |
| Operating Pressure Range | 0 kPa to 100 kPa (0 psi to 14.5 psi) |
| Тип выхода | Analog Voltage (Wheatstone bridge, ratiometric) |
| Выходное напряжение | 0 mV to 40 mV at Vex = 10 V |
| Sensitivity | 0.4 mV/kPa nominal |
| Supply Voltage (Vex) | 10 V typical (up to 16 V max) |
| Ток потребления | 6 mA typical at 10 V |
| Offset (null pressure) | 0 mV to 1 mV nominal |
| Linearity | ±0.1% FS typical (±0.5% FS max) |
| Temperature Compensation Range | 0C to 85C |
| Диапазон рабочих температур | -40C to +125C |
| Storage Temperature | -55C to +150C |
| Port Configuration | Dual horizontal ports, differential |
| Корпус | 5-SMD Module (M-PAK) |
| Тип монтажа | Surface Mount |
| Media Compatibility | Dry air and non-corrosive gases |
| Статус RoHS | Compliant (lead-free M-PAK) |
Конфигурация выводов MPXM2102D
| Контакт 1 | Vex+ — Bridge excitation supply positive |
| Контакт 2 | Vout+ — Bridge output positive (Wheatstone tap) |
| Контакт 3 | GND — Bridge excitation ground reference |
| Контакт 4 | Vout- — Bridge output negative (Wheatstone tap) |
| Контакт 5 | Vex- — Bridge excitation return |
Типичное применение
MPXM2102D подходит для 6 применениеs: Medical Spirometer / Respiratory Flow Meter, HVAC Differential Pressure / Filter Monitoring, Industrial Process Control / Gas Flow, Pneumatic Actuator / Vacuum System Feedback, Barometric / Altimeter Module (Pair with Absolute Sensor), Liquid-Level / Tank Differential Sensing.
Medical Spirometer / Respiratory Flow Meter
Differential pressure across a flow element (Fleisch pneumotach or differential-pressure orifice) is the standard spirometry measurement principle. The MPXM2102D's 0 to 100 kPa range covers the pressure drops typical of pneumotach flow heads (~0.1 to 5 kPa) while leaving headroom for coughing transients. Its 0.4 mV/kPa nominal sensitivity at 10 V excitation produces a 40 mV full-scale output that is easily amplified by an instrumentation amplifier (INA128 or AD8421) into a 0 to 4 V ADC range. Compared to a gauge-mode absolute sensor, the differential topology rejects ambient barometric pressure variation, which is critical for accurate tidal-volume measurement across changing altitudes or weather conditions.
Рекомендуется
HVAC Differential Pressure / Filter Monitoring
Building automation routinely monitors duct static pressure and filter-loading differential to trigger fan-speed changes and maintenance alerts. The MPXM2102D measures pressure drops of 0 to 100 kPa across filter banks, cooling coils, and variable-air-volume boxes. The horizontal dual-port M-PAK module simplifies plumbing into ductwork with opposed barbed fittings, and the on-chip temperature compensation from 0 to 85 C tracks HVAC air-handler environments directly. Compared to industrial gauge sensors, the differential topology allows bidirectional pressure measurements (clean-side vs dirty-side) without an external reference, simplifying installation.
Рекомендуется
Industrial Process Control / Gas Flow
Orifice-plate and laminar-flow-element flow meters use differential pressure as the primary flow variable (Bernoulli's equation). The MPXM2102D's 0 to 100 kPa range is well-matched to low-flow gas chromatography, vacuum-pump inlet monitoring, and cleanroom pressure cascade control. The 5-SMD M-PAK surface-mount package enables PCB-level integration inside a sealed flow-meter housing, and the 6 mA typical supply current at 10 V allows the sensor to share a regulated supply with adjacent instrumentation. Compared to integrated digital flow sensors, the analog output preserves bandwidth for transient flow-pulse analysis in process-control loops.
Рекомендуется
Pneumatic Actuator / Vacuum System Feedback
Closed-loop control of pneumatic actuators and vacuum grippers requires a real-time differential pressure feedback signal proportional to cylinder force or vacuum level. The MPXM2102D reports cylinder-side pressure directly, enabling force control algorithms in pick-and-place robots and vacuum-clamp systems. Its -40 to +125 C operating range supports factory-floor temperature swings, and the 0 to 40 mV ratiometric output simplifies ADC front-end design. Compared to a sealed gauge sensor, the differential topology allows the low-pressure port to reference atmospheric pressure - critical for vacuum systems where absolute measurement would require a vacuum reference.
Рекомендуется
Barometric / Altimeter Module (Pair with Absolute Sensor)
The MPXM2102D is differential rather than absolute, so it cannot directly measure barometric pressure - but it pairs with the MPXM2102A (absolute vacuum-reference) variant on the same PCB to compute a true barometric pressure. In altimeter and weather-station designs, the differential sensor monitors enclosure wind pressure or venturi airspeed while the absolute sensor reports atmospheric pressure. The identical M-PAK 5-SMD footprint lets designers use the same PCB layout for either or both sensors. Compared to integrated BMP280-class digital barometers, this analog solution preserves bandwidth for fast weather-front detection and avoids I2C bus contention.
Рекомендуется
Liquid-Level / Tank Differential Sensing
Differential pressure measurement is the most reliable way to infer liquid level in a vented tank - one port sits in the headspace, the other in the liquid head, and the difference yields the hydrostatic column height independent of atmospheric variation. The MPXM2102D's 0 to 100 kPa range covers up to 10 meters of water column, suitable for process tanks and small reservoirs. The horizontal-port M-PAK module can be mounted adjacent to the tank wall with short flexible tubing, eliminating liquid wetted sensors. Compared to submersible hydrostatic probes, the external differential sensor keeps electronics out of the process fluid.
Рекомендуется
Сводка рекомендуемых товаров
Справочные инженерные данные для MPXM2102D — сравнение, рекомендации по проектированию и информация о соответствии.
Руководство по выбору
Сравнение с аналогами
| Параметр | Этот товар | MPXM2202D | MPXM2102A | MPXM2102GS | MPXM2102DT1 |
|---|---|---|---|---|---|
| Brand | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors | NXP Semiconductors |
| Package | 5-SMD Module (M-PAK) | 5-SMD Module (M-PAK) - same | 5-SMD Module (M-PAK) - same | 5-SMD Module (M-PAK) - same | 5-SMD Module (M-PAK) - same |
| Pressure Type | Differential | Differential | Absolute | Gauge | Differential |
| Operating Pressure Range | 0 to 100 kPa (14.5 psi) | 0 to 200 kPa (29 psi) | 0 to 100 kPa (14.5 psi) | 0 to 100 kPa (14.5 psi) | 0 to 100 kPa (14.5 psi) |
| Output Voltage | 0 to 40 mV at Vex = 10 V | 0 to 40 mV at Vex = 10 V | 0 to 40 mV at Vex = 10 V | 0 to 40 mV at Vex = 10 V | 0 to 40 mV at Vex = 10 V |
| Sensitivity | 0.4 mV/kPa nominal | 0.2 mV/kPa nominal | 0.4 mV/kPa nominal | 0.4 mV/kPa nominal | 0.4 mV/kPa nominal |
| Supply Voltage | 10 V typical (16 V max) | 10 V typical (16 V max) | 10 V typical (16 V max) | 10 V typical (16 V max) | 10 V typical (16 V max) |
| Operating Temperature | -40C to +125C | -40C to +125C | -40C to +125C | -40C to +125C | -40C to +125C |
| RoHS | Compliant | Compliant | Compliant | Compliant | Compliant |
Ключевые отличия
- Differential topology with horizontal ports (против MPXM2102GS (gauge variant))
- On-chip temperature compensation 0 to 85 C (против Generic uncompensated bridge sensors)
- Same M-PAK 5-SMD footprint as the broader MPXM2xxx series (против Through-hole MPX2102DP)
Заметки по проектированию
The MPXM2102D bridge draws approximately 6 mA at 10 V excitation. Provide a low-noise regulated supply with a 0.1 uF ceramic decoupling capacitor placed as close as possible to pins 1 (Vex+) and 5 (Vex-/GND). Switching regulators on the same board can couple ripple into the ratiometric output - place an LC pi-filter (10 uH + 10 uF + 0.1 uF) on the bridge supply for sub-mV noise floors. The output is ratiometric with Vex, so any supply noise appears directly on the output.
The 0 to 40 mV full-scale output requires careful analog signal-chain design. Use a low-offset (<100 uV), low-drift (<5 uV/C) instrumentation amplifier such as INA128, INA333, or AD8421 with gain of ~100 to map the full scale into a 0 to 4 V ADC input. Add a first-order RC low-pass filter (R=10 kohm, C=10 nF, fc=1.6 kHz) at the in-amp output to reject sensor thermal noise. PCB layout must use Kelvin-sense wiring at the bridge pads and a guard trace around the analog signal path to reject leakage from the digital section.
Do not expose the M-PAK housing or ports to mechanical stress - package strain couples directly into the silicon diaphragm and shifts the output. Avoid potting or overmolding the sensor body. Use flexible silicone tubing on both ports and secure the PCB with standoffs rather than rigid mounts. For media compatibility, the sensor is rated for dry air and non-corrosive gases only - contact NXP for liquids, condensing humidity, or corrosive media. Avoid freezing the sensor with condensed water inside the ports.
On-chip temperature compensation covers 0 to 85 C only. For applications outside that range, add a software compensation step using the on-die thermistor or an external RTD. Bridge resistance drifts ~0.5% FS over the full -40 to +125 C range, so uncompensated readings at the temperature limits can show a 50 mV shift equivalent to ~12 kPa. PCB self-heating from nearby regulators can also bias the sensor - keep heat sources >10 mm away and add thermal reliefs on the copper pours.
Информация о соответствии
RoHS and REACH compliant per NXP product page. M-PAK 5-SMD variant ships lead-free; legacy through-hole MPX2102 variants are not lead-free. AEC-Q100 is not applicable for a pressure sensor at this performance tier.