Skyworks Solutions

SI3215-C-FT - 3.13-5.25V Telecom SLIC/CODEC | Skyworks Solutions

부품 번호: SI3215-C-FT ✓ 활성
3.13 V to 5.25 V Vdss 88 mA Id 38-TSSOP Package
MOQ: 1 |

SI3215-C-FT 개요

The Skyworks Solutions SI3215-C-FT is a single-channel Subscriber Line Interface Concept (SLIC) and CODEC for customer premise equipment, packaged in a 38-pin TSSOP. It operates from a 3.13 V to 5.25 V supply and consumes 88 mA, with listed power dissipation of 700 mW. The device performs the BORSCHT telephone-line functions and includes software-programmable internal balanced ringing up to 90 VPK. It is designed for 5 REN and 4 kft line conditions, with additional ringing support for 3 REN and 8 kft line lengths. Its GCI, PCM, and SPI interfaces support integration with a digital communications processor or system controller. The SI3215-C-FT also incorporates an integrated battery supply with dynamic operation, DTMF generation, and expanded telephony signaling capabilities for Japan and China country requirements. These characteristics make it suitable for analog telephone adapters, voice-over-IP gateways, customer premises equipment, and other embedded voice systems. Compared with discrete telephone-interface circuitry, the integrated SLIC and CODEC consolidate line termination, codec, ringing, and signaling functions into one programmable component. The 0°C to 70°C operating range supports commercial equipment deployments, while the TSSOP package supports conventional surface-mount assembly. Design evaluation should include line-length and REN requirements, ringing voltage and cadence, PCM or SPI host connectivity, thermal performance at 700 mW, and the external line-network components required by the manufacturer reference design.

드롭인 대체품: SI3215-C-FT — 동일 패키지, 핀 호환. PCB 재작업이 필요한 다른 패키지 부품은 제외됩니다.

이 시리즈의 변형

다음과 드롭인 호환되는 동일 시리즈 모델: SI3215-C-FT (동일 폼 팩터 및 풋프린트) — 차이점: Battery Supply, Package, Product Type, Telephone Functions.

Silicon Labs
Battery Supply: Integrated battery supply with dynamic voltage output
Package: 38-pin TSSOP
Product Type: Programmable CMOS SLIC/codec (ProSLIC)
비교 대상: SI3215-C-FT →

SI3215-FT

✅ 드롭인
Silicon Labs
📦 38-TSSOP
Programmable CMOS SLIC/codec (ProSLIC) · 1 channel · 90 VPK · 5 REN · 3 REN · Software-configurable internal balanced ringing · Integrated battery supply with dynamic voltage output · Integrated controller with continuous power minimization

가격 문의

데이터시트 보기 →

SI3215-C-FT 사양

Product Type Subscriber Line Interface Concept (SLIC) and CODEC
Number of Channels 1 channel
Supply Voltage Range 3.13 V to 5.25 V
공급 전류 88 mA
Power Dissipation 700 mW
동작 온도 0°C to 70°C
패키지 38-TSSOP
Package Type 38-TFSOP, 4.40 mm width
Interfaces GCI, PCM, SPI
Internal Ringing Software-programmable, up to 90 VPK
Ringing Line Support 5 REN at 4 kft; 3 REN at 8 kft
Telephone Functions BORSCHT functions
DTMF Support DTMF generation
Battery Supply Integrated battery supply with dynamic operation
Country Signaling Expanded support for Japan and China country requirements
Lead-Free Status Lead-free
실장 유형 Surface mount
Manufacturer Skyworks Solutions

SI3215-C-FT 38-tfsop, 4.40 mm width 핀 구성 가이드

SI3215-C-FT(38-tfsop, 4.40 mm width 패키지)의 핀 구성입니다. 핀 번호, 기능, 연결 다이어그램은 제조사 데이터시트에 정의되어 있습니다. 정확한 풋프린트와 솔더링 지침은 해당 문서를 참조하십시오.

SI3215-C-FT의 38-tfsop, 4.40 mm width 패키지 핀아웃 다이어그램

다음에 대한 상세 핀아웃 데이터 없음: SI3215-C-FT.

다음을 참조하십시오: 데이터시트 전체 핀 구성은 다음을 참조하십시오.

일반적인 애플리케이션

SI3215-C-FT 적합 용도: 6 애플리케이션s: Analog Telephone Adapter, Voice-over-IP Gateway, Customer Premises Equipment, Embedded Voice Communication System, Digital Transport Card, Telephony Test and Measurement Equipment.

📞

Analog Telephone Adapter

The SI3215-C-FT is suitable for an analog telephone adapter because it combines one subscriber-line interface, CODEC, BORSCHT functions, DTMF generation, and programmable ringing in one device. Its GCI, PCM, and SPI connectivity allows the adapter to bridge an analog line to a digital voice processor. The 3.13 V to 5.25 V supply range fits common embedded voice platforms, while the 90 VPK internal ringing capability supports phone-call signaling. The 88 mA supply specification must be included in the host power budget, and the 700 mW listed dissipation should be checked against the TSSOP land pattern and ambient temperature.

🌐

Voice-over-IP Gateway

A voice-over-IP gateway can use the SI3215-C-FT as the analog subscriber-line interface in front of a packet-voice processor. The SLIC handles the physical telephone line, ringing generation, and BORSCHT line functions, while the PCM, GCI, or SPI interface carries voice and control traffic to the host. Programmable ringing up to 90 VPK and support for 5 REN at 4 kft or 3 REN at 8 kft help define line loading. Because this is a one-channel part, gateways requiring multiple simultaneous lines need additional SI3215 devices and careful clock, power, and grounding coordination.

🏠

Customer Premises Equipment

The SI3215-C-FT targets customer premises equipment that terminates one analog telephone line while providing a digital interface to an embedded controller. Its low-voltage CMOS operation from 3.13 V to 5.25 V supports compact commercial designs, and its integrated battery supply with dynamic operation assists line-state handling. The 38-TSSOP package is compatible with conventional surface-mount assembly. Design teams should use the manufacturer application circuit to establish line-network component values, protection requirements, and thermal copper, especially where ringing and off-hook power conditions coincide.

🔧

Embedded Voice Communication System

The SI3215-C-FT can serve as the line-facing element in an embedded voice communication system that needs telephone signaling, DTMF, and integrated codec functions. GCI and PCM connectivity supports systems organized around PCM transport, while SPI supports register-oriented control and configuration. The single-channel architecture simplifies board partitioning for one-line endpoints, and the 0°C to 70°C commercial operating range aligns with indoor customer equipment. Firmware configuration, host-driver support, and the exact external line-network topology remain critical system-level compatibility items.

🖥️

Digital Transport Card

A single-line digital transport card can use the SI3215-C-FT when it must terminate an analog subscriber line and expose PCM or serial control to a line card. The device consolidates line termination, ringing generation, DTMF generation, codec operation, and signaling support rather than requiring separate line-interface blocks. Its 3.13 V to 5.25 V operating range allows integration with common embedded supply rails, subject to system-level sequencing. For dense cards, thermal analysis should account for 700 mW listed dissipation, and the external protection network must be rated for the programmed ringing voltage.

🛠️

Telephony Test and Measurement Equipment

The SI3215-C-FT can provide a controllable analog-line endpoint in telephony test equipment that evaluates ring voltage, DTMF generation, line-state behavior, and codec communication. Software-programmable ringing up to 90 VPK allows test profiles to be adjusted for supported REN and loop-length conditions, while GCI, PCM, and SPI interfaces support different host architectures. The device's 88 mA supply current and 700 mW power specification should be included in instrumentation power and thermal budgets. Production testers should also account for the 0°C to 70°C operating range and required protection against external line transients.

What is the operating voltage of SI3215-C-FT?
The SI3215-C-FT operates from 3.13 V to 5.25 V. According to the manufacturer datasheet, this single-channel ProSLIC is a low-voltage CMOS telephone interface for customer premise equipment. The 88 mA supply-current specification is useful when sizing the host supply, while the 700 mW power figure should be considered during thermal design in the 38-TSSOP package.
What does SI3215-C-FT do?
The SI3215-C-FT integrates a Subscriber Line Interface Concept and CODEC for one analog telephone line. It performs the BORSCHT line functions, provides programmable internal ringing up to 90 VPK, generates DTMF tones, and includes an integrated battery supply. The device is intended for CPE, voice gateways, and other embedded telecommunications systems.
Where can I download the SI3215-C-FT datasheet PDF?
The SI3215-C-FT datasheet PDF is available through the manufacturer datasheet link at https://www.mouser.com/datasheet/2/368/Si3215-276819.pdf. It documents the ProSLIC functions, programming model, electrical characteristics, line-interface behavior, and package information. Use the pin-description table and application-circuit sections when assigning PCB tracks and selecting external line-network components.
Where can I find the SI3215-C-FT pinout?
The SI3215-C-FT uses a 38-pin TSSOP package, and its complete pin assignments are shown in the manufacturer datasheet. Use the pin-description table and package drawing to identify supply, ground, digital interface, analog line, ringing, and battery connections. The search result confirms the 38-TSSOP package but does not reproduce every pin name, so do not assign the board footprint from the listing alone.
What interfaces does SI3215-C-FT support?
The SI3215-C-FT supports GCI, PCM, and SPI interfaces. These interfaces allow the SLIC and CODEC to connect with a digital communications processor, PCM transport path, or serial control system. Interface selection should match the host processor, line-card architecture, and software-control requirements of the customer premise equipment.
What ringing voltage does SI3215-C-FT support?
The SI3215-C-FT provides software-programmable internal balanced ringing up to 90 VPK. The manufacturer listing specifies 5 REN at 4 kft and 3 REN at 8 kft for the associated line conditions. These values help define the supported telephone-line loading and determine the ringing-network implementation used around the SLIC.
Is SI3215-C-FT suitable for customer premises equipment?
Yes, the SI3215-C-FT is specifically designed for customer premises equipment and other telecommunications systems. It combines one-channel line-interface functions, programmable ringing, DTMF generation, battery-feed operation, and digital host interfaces in a 38-TSSOP package. The 0°C to 70°C range suits commercial ambient conditions.
How much current does SI3215-C-FT consume?
The SI3215-C-FT has a listed supply current of 88 mA. At a 5.25 V supply, that corresponds to approximately 0.462 W of input power, close to the listed 700 mW dissipation specification. Designers should verify the actual supply demand and thermal conditions in the host equipment rather than relying on a single nominal value.
What is the difference between SI3215-C-FT and SI3215-FT?
The SI3215-FT is a related Skyworks ProSLIC single-channel SLIC and CODEC, while the SI3215-C-FT is the commercial-temperature 0°C to 70°C version identified in the current product listing. Both are associated with the ProSLIC family and 38-pin TSSOP packaging, but software, electrical, and availability details should be checked against the appropriate datasheet before substitution.
Can SI3215-FT replace SI3215-C-FT?
SI3215-FT may be a close same-package family alternative, but replacement should be approved only after checking its exact temperature grade, electrical limits, firmware support, and pin configuration against the SI3215-C-FT datasheet. The cross-reference listing identifies SI3215-FT as a related product, while the present records do not establish every operating parameter as identical.
What can replace SI3215-C-FT?
SI3215-FT is the most directly identified same-family replacement candidate for the SI3215-C-FT, with the same broad ProSLIC SLIC/CODEC function and 38-pin TSSOP association. A board-level substitution should still verify pin-to-pin connectivity, line impedance, ringing behavior, temperature range, firmware, and supply sequencing against the original design.
Where can I buy SI3215-C-FT online?
Use the Request a Quote form on this page to request availability, lead time, and a purchase quotation for the SI3215-C-FT. The current product record identifies the component as a Skyworks Solutions 38-TSSOP SLIC and CODEC, but no qualified current quantity-break listing is available for the exact SI3215-C-FT suffix.
What is the price of SI3215-C-FT?
The current product page provides a Request a Quote form for SI3215-C-FT pricing and availability. No quantity-break price table for the exact SI3215-C-FT suffix is available in the current records, so use the quote form rather than treating a family or different suffix listing as the price of this exact part.
What is the lead time and stock status for SI3215-C-FT?
Request current stock, minimum order quantity, and lead time through the Request a Quote form on this page. The SI3215-C-FT listing identifies the component as available for quotation, but the current records do not state a numeric lead time or a confirmed stock quantity for the exact MPN.
Is SI3215-C-FT RoHS compliant?
The available product records confirm lead-free status for the SI3215-C-FT, but they do not explicitly state RoHS, REACH, AEC-Q100, halogen-free, or conflict-minerals status. Use the Request a Quote form for current manufacturer compliance documentation before treating the component as qualified for a regulated production program.
What are the key specifications of SI3215-C-FT?
The key SI3215-C-FT specifications are a 3.13 V to 5.25 V supply, 88 mA supply current, 700 mW listed power, one-channel SLIC and CODEC operation, GCI/PCM/SPI interfaces, programmable 90 VPK internal ringing, and a 38-TSSOP package. Its operating range is 0°C to 70°C. These features define its use in commercial CPE and embedded voice equipment.

엔지니어링 참조 데이터: SI3215-C-FT — 비교, 설계 지침 및 규정 준수 정보.

선택 가이드

Choose the SI3215-C-FT for a commercial-temperature, single-channel analog telephone interface in customer premises equipment, analog telephone adapters, voice gateways, or embedded line cards. Its 3.13 V to 5.25 V supply range, GCI/PCM/SPI connectivity, programmable ringing up to 90 VPK, DTMF generation, and integrated battery supply consolidate several telephone functions into one device. Consider SI3215-FT when its exact electrical ratings, temperature grade, and firmware compatibility match the target design, but verify those details against its datasheet because the current cross-reference information does not prove full parameter identity. The SI3215-C-FTR record is a tape-and-reel ordering suffix and should not be treated as a distinct replacement. For multi-line products, use additional SLIC channels with careful clock, grounding, power, and thermal planning rather than assuming the one-channel SI3215-C-FT can terminate multiple lines.

대체품과의 비교

파라미터 이 제품 SI3215-FT
Package 38-TSSOP 38-TSSOP
Brand Skyworks Solutions Skyworks Solutions
Product Type Single-channel Subscriber Line Interface Concept and CODEC Single-channel ProSLIC SLIC and CODEC
Number of Circuits 1 1

주요 차별점

  • Commercial-temperature identification (vs SI3215-FT)
  • Integrated one-channel telephone interface (vs SI3215-FT)
  • Multiple digital connectivity options (vs SI3215-FT)

설계 노트

Design the supply rail for 88 mA supply current across the full 3.13 V to 5.25 V operating range. At 5.25 V, the nominal input power associated with 88 mA is approximately 0.462 W. This is an estimate, while the listed device power dissipation is 700 mW. Confirm startup current, battery-supply behavior, sequencing, and line-state transients against the manufacturer electrical-characteristics table before setting the power-supply limit.

Use the 700 mW listed power dissipation as the thermal-design starting point for the 38-TSSOP package. Provide copper around the device and minimize thermal coupling to sensitive analog sections. The operating range is 0°C to 70°C, so calculate worst-case junction temperature at the highest ambient temperature and under the line conditions that produce the greatest dissipation. The manufacturer application circuit should guide land-pattern and copper-area recommendations.

Separate the analog subscriber-line path from digital clock, SPI, PCM, and power-return routing. Keep the SLIC, external line-network components, and protection components in the same compact signal-chain region, while maintaining a continuous ground reference between the device and its external circuitry. Follow the manufacturer layout and application circuit for isolation gaps, surge protection, and component placement rather than inferring those values from the package drawing.

Do not substitute a similarly named SI3215 variant solely because it is available in a 38-pin package. Verify the temperature grade, supply limits, digital interfaces, firmware register map, ringing behavior, and exposed-pin or package details against the exact datasheet. The SI3215-C-FTR record represents a reel-order suffix and is not treated as a separate engineering alternative, while SI3215-FT still requires application-level compatibility confirmation.

규정 준수 정보

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
무연
Yes
무할로겐
Unknown
분쟁 광물
Unknown

Lead-free status is listed for SI3215-C-FT. Explicit RoHS, REACH, AEC-Q100, halogen-free, and conflict-minerals declarations were not identified in the available records.

관련 검색

SI3215-C-FT datasheet SI3215-C-FT specifications SI3215-C-FT pinout SI3215-C-FT datasheet pdf Skyworks SI3215-C-FT SI3215-C-FT replacement SI3215-C-FT equivalent SI3215-C-FT vs SI3215-FT SI3215-C-FT 38-TSSOP SI3215-C-FT telecom interface SI3215-C-FT price SI3215-C-FT stock SI3215-C-FT application circuit SI3215-C-FT ringing voltage 38-TSSOP SLIC CODEC

관련 부품 & 용어

Skyworks Solutions SI3215-C-FT SI3215-FT ProSLIC Subscriber Line Interface Concept SLIC CODEC telephone interface IC customer premises equipment GCI PCM SPI BORSCHT functions DTMF generation programmable internal ringing 90 VPK 5 REN 3 REN 88 mA supply current 700 mW power dissipation 38-TSSOP surface-mount package low-voltage CMOS analog telephone line voice-over-IP gateway
빠른 견적 RFQ
상세 정보를 모두 입력하십시오 — 영업팀이 24시간 이내에 답변드립니다
부품 번호 제조사 패키지 QTY 목표 가격 합계
✓
견적이 제출되었습니다!

24시간 이내에 이메일로 답변드리겠습니다

1
RFQ 제출됨
2
견적 접수됨
3
주문 완료
4
결제
5
배송됨
6
배송 완료
RFQ 상세 보기