AD580UH/883B - 2.5V Precision Voltage Reference | Analog Devices
MPN: AD580UH/883B β Active| Qty | Unit Price | Extended |
|---|---|---|
| 1 | $218.09 | $218.09 |
| 10 | $210 | $2,100.00 |
| 100 | $195 | $19,500.00 |
| 500 | $180 | $90,000.00 |
| 1,000 | $165 | $165,000.00 |
Drop-in alternatives for AD580UH/883B β same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.
Quick Comparison Tool β Select alternative parts for side-by-side comparison:
AD580SH/883B
β Drop-Inπ Reference alternative (not in catalog)
AD581UH/883B
β Drop-Inπ Reference alternative (not in catalog)
AD584SH/883B
β Drop-Inπ Reference alternative (not in catalog)
REF01AJ/883C
β Drop-Inπ Reference alternative (not in catalog)
REF02AZ/883C
β Drop-Inπ Reference alternative (not in catalog)
AD580UH/883B Maximum Ratings & Electrical Characteristics
| Output Type | Fixed |
| Output Voltage | 2.5 V |
| Output Tolerance | Β±0.4% |
| Input Voltage Range | 4.5 V to 30 V |
| Output Current | 10 mA |
| Temperature Coefficient | 10 ppm/Β°C |
| Operating Temperature Range | -55Β°C to +125Β°C |
| Package Type | TO-52-3 (TO-206AC) Metal Can |
| Mounting Type | Through Hole |
| Long-Term Stability | 25 V/month |
| Quiescent Current | [DATA_NEEDED: Quiescent current] |
| Reference Type | Series |
| MIL-STD-883 | Class B compliant |
| RoHS Status | unknown |
| Lead-Free | unknown |
AD580UH/883B Pin Configuration
| Pin 1 | VIN β Input voltage (4.5V to 30V) |
| Pin 2 | GND β Ground |
| Pin 3 | VOUT β 2.5V reference output |
Safe Operating Area (SOA) & Thermal Characteristics
No official SOA curve available for this component. Always operate within absolute maximum ratings specified in the datasheet. Ensure adequate cooling and derate as needed.
Typical Applications
AD580UH/883B is suitable for 6 applications: Military Avionics, Precision Data Acquisition, Industrial Process Control, Medical Instrumentation, Aerospace Telemetry, Test and Measurement.
Military Avionics
The AD580UH/883B provides a stable 2.5V reference for avionics data acquisition systems, ensuring accurate sensor readings in extreme temperatures. Its MIL-STD-883 compliance and hermetic package guarantee reliability in harsh environments, with a temperature coefficient of 10 ppm/Β°C maintaining precision from -55Β°C to +125Β°C.
Recommended
Precision Data Acquisition
In data acquisition systems, the AD580UH/883B serves as a reference for high-resolution ADCs, providing a low-noise 2.5V source. Its Β±0.4% accuracy and 10 ppm/Β°C stability ensure minimal conversion errors, while the 10 mA output current can drive multiple ADC reference inputs. The wide input range allows operation from 5V to 30V supplies.
Recommended
Industrial Process Control
The AD580UH/883B is ideal for industrial process control systems where precise voltage references are critical for sensor signal conditioning. Its wide input voltage range (4.5V to 30V) accommodates various industrial supply rails, and its temperature stability ensures consistent performance in factory environments. The hermetic package protects against moisture and contaminants.
Recommended
Medical Instrumentation
In medical devices, the AD580UH/883B provides a stable reference for patient monitoring and diagnostic equipment. Its low temperature drift (10 ppm/Β°C) ensures accurate measurements over body temperature variations, and the hermetic TO-52-3 package meets stringent reliability requirements. The device's low quiescent current is suitable for battery-powered portable monitors.
Recommended
Aerospace Telemetry
The AD580UH/883B is used in aerospace telemetry systems to provide a precise voltage reference for data encoding and transmission. Its MIL-STD-883 Class B compliance ensures it can withstand the vibration and temperature extremes of spaceflight. The 2.5V output is compatible with many telemetry ADCs, and the wide input range allows direct connection to 28V spacecraft buses.
Recommended
Test and Measurement
In test and measurement equipment, the AD580UH/883B provides a stable reference for calibration and measurement circuits. Its high accuracy (Β±0.4%) and low temperature coefficient (10 ppm/Β°C) ensure reliable readings across a wide temperature range. The device's hermetic package and long-term stability (25 V/month) make it suitable for precision instruments used in laboratory and field environments.
Recommended
Recommended Products Summary
Engineering reference data for AD580UH/883B β comparison, design guidance, and compliance information.
Selection Guide
Comparison with Alternatives
| Parameter | This Product | AD580SH/883B | AD581UH/883B | AD584SH/883B |
|---|---|---|---|---|
| Package | TO-52-3 | TO-52-3 | TO-52-3 | TO-52-3 |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Output Voltage | 2.5V | 2.5V | 10V | 2.5V/5V/7.5V/10V |
| Output Current | 10mA | 10mA | 10mA | 10mA |
| Temperature Coefficient | 10 ppm/Β°C | 10 ppm/Β°C | 10 ppm/Β°C | 10 ppm/Β°C |
| Input Voltage Range | 4.5V to 30V | 4.5V to 30V | 12V to 40V | 4.5V to 30V |
| MIL-STD-883 | Class B | Class B | Class B | Class B |
| Price (1pc) | $218.09 | [DATA_NEEDED] | [DATA_NEEDED] | [DATA_NEEDED] |
Key Differentiators
- MIL-STD-883 Class B compliance (vs Standard AD580)
- Hermetic TO-52-3 package (vs Plastic packages)
- Tight temperature coefficient of 10 ppm/Β°C (vs AD580SH/883B)
Design Notes
The AD580UH/883B requires an input voltage at least 2V above the output (2.5V) for proper regulation. For a 5V supply, ensure the input is stable and well-filtered. Use a 0.1uF ceramic capacitor on the input and a 1uF tantalum capacitor on the output to maintain stability and reduce noise.
The TO-52-3 metal can package provides good thermal conductivity. For high input voltages (e.g., 30V) and maximum output current (10mA), power dissipation is (30V-2.5V)*10mA = 275mW, which is within the package's capability. Ensure adequate airflow or heatsinking if operating near maximum ratings in high ambient temperatures.
Keep the AD580UH/883B close to the ADC reference input to minimize trace inductance and noise pickup. Use a ground plane and separate analog and digital grounds. Avoid routing high-frequency digital signals near the reference output. Follow the layout guidelines in the AD580 datasheet for optimal performance.
Compliance Information
MIL-STD-883 Class B compliant per Analog Devices cross-reference guide. RoHS/REACH status not specified in provided data.