AD582KH - 1.5MHz Sample-and-Hold Amplifier | Analog Devices
MPN: AD582KH ✓ 啟用中AD582KH 概覽
A sample-and-hold amplifier is an analog integrated circuit that samples an input voltage during a controlled acquisition interval and then stores that voltage on an external holding capacitor. It belongs to the broader sample-and-hold amplifier category, which combines an operational amplifier, a low-leakage analog switch, and a JFET integrating amplifier. The AD582 also provides separate analog and digital ground connections to improve immunity to ground and switching transients.
Key characteristics include one sampling channel, 1.5 MHz bandwidth, 6 us acquisition time, 2 mV input offset voltage, and 500 ns settling time. The external holding capacitor allows the sampled level to remain available after the acquisition interval ends. Separate analog and digital grounds are particularly useful in mixed-signal systems where the input signal path and digital control circuitry can otherwise share switching disturbances.
The AD582 is fabricated as a monolithic sample-and-hold circuit containing a high-performance operational amplifier, a low-leakage analog switch, and a JFET integrating amplifier. Its architecture supports rapid acquisition followed by stable signal holding, while the 10-pin TO-100 package facilitates through-hole assembly and repair. Analog Devices also identifies MIL-STD-883-compliant versions within the AD582 product family, although the exact qualification status of the KH suffix should be confirmed for a regulated program.
Typical applications include precision data-acquisition front ends, laboratory instrumentation, industrial process control, analog measurement systems, pulse sampling, and communications equipment. The AD582KH is particularly appropriate when a sampled analog value must be captured and held for conversion, comparison, control, or further signal processing during a later system cycle.
Circuit design must provide a suitable external holding capacitor, maintain low-leakage routing around the held node, and connect the analog and digital grounds according to the Analog Devices AD582 datasheet. Input and control timing also determine whether the 6 us acquisition specification is sufficient for the signal being sampled. Stable reference and supply arrangements are necessary for repeatable system-level accuracy.
This page combines the manufacturer architecture description, listed electrical characteristics, package information, drop-in family comparisons, and practical application guidance. It is intended to help engineers determine whether the AD582KH fits a sample-and-hold requirement while also identifying the key parameters that should be verified against the manufacturer datasheet before layout or production release.
直接替換替代品,適用於 AD582KH — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: AD582KH (相同外形與佔位) — 差異在於 Package, Acquisition Time, Holding Capacitor, Product Type, Mounting Type.
AD582KH/+
✅ 直接替換📋 參考替代品(不在目錄中)
AD582SH/883B
✅ 直接替換聯絡詢價
查看資料表 →AD582KD
✅ 直接替換聯絡詢價
查看資料表 →AD582KH 最大額定值與電氣特性
| Product Type | Sample-and-hold amplifier |
| Number of Channels | 1 channel |
| Number of Amplifiers | 1 amplifier |
| Bandwidth | 1.5 MHz |
| Acquisition Time | 6 us |
| Product Category Acquisition Time | 25 us |
| Input Offset Voltage | 2 mV |
| Settling Time | 500 ns |
| Internal Elements | Operational amplifier, low-leakage analog switch, and JFET integrating amplifier |
| Holding Capacitor | External |
| Ground Configuration | Separate analog and digital grounds |
| Transient Immunity | Immunity to ground and switching transients |
| 封裝 | TO-100-10 |
| 腳位數 | 10 pins |
| 安裝類型 | Through-hole |
| Military Version Availability | MIL-STD-883-compliant versions available within the AD582 family |
AD582KH to-100-10 腳位配置指南
AD582KH(to-100-10 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: AD582KH.
請參閱 資料表 以查看完整腳位配置。
典型應用
AD582KH 適用於 6 應用s: Precision Data-Acquisition Front End, Laboratory Instrumentation, Industrial Process Control, Analog Measurement and Control Loops, Pulse and Transient Sampling, Communications Signal Conditioning.
Precision Data-Acquisition Front End
The AD582KH fits a precision data-acquisition front end that must capture a changing analog input and present a stable held value to a converter or control system. Its listed 6 us acquisition time supports comparatively fast sampling intervals, while 1.5 MHz bandwidth accommodates higher-frequency input components. The 2 mV input offset and 500 ns settling characteristics should be included in the system error budget. Route the held node carefully, select the external holding capacitor according to the Analog Devices guidance, and keep leakage-producing traces away from the sample node.
推薦
Laboratory Instrumentation
The AD582KH can form the sampling stage of laboratory instrumentation that measures a rapidly varying signal and then holds it for display, calibration, or digitization. Its 1.5 MHz bandwidth provides useful signal-path bandwidth, and the 500 ns settling specification helps define how quickly the output can be considered settled after acquisition. The separate analog and digital ground terminals are valuable in instruments containing switching displays or digital control circuitry. Keep sensitive grounding paths isolated from those return currents and verify capacitor leakage against the required measurement accuracy.
推薦
Industrial Process Control
The AD582KH is applicable to industrial process-control loops where a pressure, temperature, or other analog sensor signal must be sampled at a controlled instant and held during controller processing. The 6 us acquisition time allows the sampling system to respond within a relatively short acquisition interval, while the 1.5 MHz bandwidth can pass faster sensor transients. Separate analog and digital grounds improve transient immunity in systems with relays, motor drives, or switching power stages. Provide filtering appropriate to the sensor bandwidth and maintain strict leakage control around the external holding capacitor.
推薦
Analog Measurement and Control Loops
The AD582KH can capture an analog measurement and hold it for comparison, threshold evaluation, or closed-loop control. Its 2 mV listed input offset must be included in the achievable measurement accuracy, while the 500 ns settling time helps establish the interval available to the following measurement or control stage. The 10-pin TO-100-10 package supports through-hole construction and repairable laboratory or industrial equipment. Design the analog input path to avoid overload, verify common-mode and supply limits from the manufacturer datasheet, and use separate analog and digital ground routing.
推薦
Pulse and Transient Sampling
The AD582KH is suitable for capturing short-lived analog events that would be difficult to observe reliably with a continuously displaying measurement system. The 1.5 MHz bandwidth supports signal content around that range, and the 6 us acquisition figure provides the timing basis for capturing the event before the hold interval begins. Holding the selected level on an external capacitor allows downstream circuitry to process the event after the source has changed. Check input amplitude, sampling aperture, switch leakage, and capacitor dielectric behavior because these parameters determine whether the captured value retains the required amplitude.
推薦
Communications Signal Conditioning
The AD582KH can serve as a sampling element in communications equipment that needs to capture an analog level for later demodulation, thresholding, or feedback. Its 1.5 MHz bandwidth is suitable for many baseband signal-conditioning tasks, while separate analog and digital grounds help reduce susceptibility to switching transients in mixed-signal equipment. The sample-and-hold output must remain stable during downstream processing, making holding-capacitor selection and board contamination control especially important. Validate acquisition timing against the modulation waveform and confirm that the signal bandwidth does not exceed the device's operating limits.
推薦
推薦產品摘要
工程參考資料,適用於 AD582KH — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | AD582KH/+ | AD582SH | AD582KD |
|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | TO-100-10 | TO-100-10 - same | TO-100-10 - same | TO-100-10 - same |
| Number of Pins | 10 pins | 10 pins | 10 pins | 10 pins |
| Number of Channels | 1 channel | 1 channel | 1 channel | 1 channel |
| Acquisition Time | 6 us | 25 us family designation | 25 us | 25 us |
| Primary Architecture | Operational amplifier, low-leakage analog switch, and JFET integrating amplifier | AD582 family sample-and-hold architecture | AD582 family sample-and-hold architecture | AD582 family sample-and-hold architecture |
主要差異化特點
- Catalogued fast acquisition specification (對比AD582SH)
- Closeest listed same-footprint family match (對比AD582SH)
- Separate analog and digital grounding (對比AD582KD)
設計說明
Assign the AD582KH pins strictly from the Analog Devices package drawing and pin-description table. The TO-100-10 package is not represented by a dedicated package-diagram asset on this page, so do not infer connections from physical pin order or another AD582 suffix. Before fabrication, verify every power, ground, analog-input, holding-capacitor, and logic-control connection against the manufacturer documentation and check the PCB pad pattern against the actual TO-100 outline.
Keep the external holding-capacitor connection extremely short and protect it from contamination, flux residue, and nearby high-impedance leakage paths. The low-leakage analog switch is intended to retain charge, but PCB leakage and capacitor dielectric characteristics can still determine practical accuracy. Route the held node away from switching nodes and digital return paths, and consider guarding where long traces or humid operating conditions increase leakage.
Use the separate analog and digital ground connections to prevent control or switching return currents from flowing through the sensitive analog-ground region. Connect each ground to the intended system reference point according to the Analog Devices application guidance. Place input and holding-capacitor components close to the device, minimize loop area, and keep switching-regulator and high-current traces spatially separated from the sample-and-hold signal path.
Do not treat the 6 us acquisition specification and the 25 us family designation as interchangeable without checking the exact datasheet timing conditions. Also validate input range, supply requirements, common-mode limits, and the external holding-capacitor recommendation before applying the circuit. These checks are especially important when substituting AD582KH/+, AD582SH, or AD582KD because a shared TO-100 footprint does not guarantee identical timing under every test condition.
合規資訊
Analog Devices states that MIL-STD-883-compliant versions are available within the AD582 family. The exact AD582KH suffix is not identified as a compliant ordering code, so its individual qualification and environmental declarations require confirmation.