MPX2200A117 Overview

The NXP MPX2200A117 is a 200 kPa absolute, on-chip temperature-compensated and calibrated silicon pressure sensor supplied in a 4-SIP through-hole module (case 117). It is designed for systems that digitize or condition a piezoresistive Wheatstone-bridge output signal with a single supply between 6 V and 16 V (max 20 V), delivering a full-scale span of 40 mV nominal at 10 V excitation.

A pressure sensor, also called a pressure transducer, is a device that converts an applied differential or absolute pressure into a proportional electrical signal. The MPX2200A belongs to the MPX family of piezoresistive sensors, which sit in the broader transducer category below analog signal-chain components and above raw MEMS diaphragms. By integrating the strain-gauge bridge, temperature compensation, signal conditioning, and ESD protection on a single monolithic silicon die, NXP produces a calibrated transducer that requires only an external amplifier and ADC to deliver a digital pressure reading.

Key features include a 0 kPa to 200 kPa absolute operating range (approximately 29.01 psi), a typical full-scale span of 40 mV at 10 V excitation with a measured offset trim range that supports zero calibration, an industry-leading accuracy of ±0.25 %V FSS when externally amplified and corrected, and a temperature-compensated range of 0 °C to +85 °C. The integrated laser-trimmed thin-film network calibrates span and offset over the compensated temperature range, eliminating most software polynomial correction in the host MCU.

Architecturally, the MPX2200A employs a proprietary Monolithic Silicon Strain Gauge (MSSG) process that places the piezoresistors on a chemically etched silicon diaphragm. The diaphragm deflection is proportional to applied pressure; the resulting bridge imbalance is amplified by internal thin-film resistors and laser-trimmed for span accuracy. The result is a ratiometric analog output with low temperature coefficient of span (< -1.0 %V FSS over 0 to 85 °C) and stable long-term repeatability.

Typical applications include medical respiration monitors, HVAC air-flow controllers, industrial process control loops, altitude measurement for drones and avionics, and consumer weather stations. In a CPAP or ventilator use-case, the 0 to 200 kPa absolute range directly maps to airway pressure while the 10 V excitation span simplifies the front-end ADC reference design.

Engineers should treat the 40 mV full-scale span as a low-level signal: place a low-offset, low-noise instrumentation amplifier within 50 mm of the sensor pins, use a Kelvin connection to the excitation source, and add a small RC filter (typ. 1 kohm + 10 nF) to suppress EMI. Because the silicon die is sensitive to humid environments, the case-117 housing should be sealed with an O-ring in any liquid-coupled installation.

This page synthesizes distributor pricing, drop-in NXP and cross-brand alternatives, application notes, and PCB-level design guidelines not found in the manufacturer datasheet alone.

Drop-in alternatives for MPX2200A117 — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Variants in this series

Same-series models that are drop-in compatible with MPX2200A117 (same form factor and footprint) — differing in Mounting Type, Operating Pressure Range, Output Type, Package / Case, Port Type.

STMicroelectronics
Mounting Type: Through-Hole
Operating Pressure Range: 0 kPa to 200 kPa (0 to 29.01 PSI)
Output Type: Analog Wheatstone Bridge
Compare with MPX2200A117 →

Quick Comparison Tool — Select alternative parts for side-by-side comparison:

No drop-in alternatives available for this product.

Request Alternatives

MPX2200A117 Maximum Ratings & Electrical Characteristics

Pressure Type Absolute
Operating Pressure Range 0 kPa to 200 kPa (approx. 29.01 psi)
Supply Voltage (Excitation) 6 V to 16 V (max 20 V)
Full-Scale Span (Typical) 40 mV at 10 V excitation
Offset (Trimmed) 0 mV to 40 mV
Accuracy ±0.25 %V FSS (after external amplification)
Temperature Compensation Range 0 C to +85 C
Operating Temperature Range -40 C to +125 C
Output Type Analog, ratiometric bridge
Package / Case 4-SIP Module (case 117)
Port Type Single axial port (barbed)
Mounting Type Through-hole (SIP)
Media Compatibility Dry, non-corrosive gases
RoHS Status Compliant
Lead Finish Matte tin (Pb-free)
MSL Level Not applicable (through-hole)

MPX2200A117 Pin Configuration

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Pin 1 Vs+ — Positive supply / excitation (6 V to 16 V)
Pin 2 Vout+ — Positive differential output
Pin 3 GND — Ground reference for excitation and outputs
Pin 4 Vout- — Negative differential output

Typical Applications

MPX2200A117 is suitable for 7 applications: Medical CPAP / Ventilator Airway Pressure, HVAC Duct Airflow Pressure, Drone and UAV Altitude Reference, Industrial Process Pressure Monitoring, Consumer Weather Station, Respiratory / Spirometer Flow Sensing, Appliance Water-Level and Pump Pressure Sensing.

💊

Medical CPAP / Ventilator Airway Pressure

The MPX2200A117's 0 to 200 kPa absolute range (approx. 29.01 psi) maps directly onto CPAP and bilevel ventilator circuit pressures, which typically operate between 4 and 20 cmH2O but may exceed 200 kPa during single-fault condition. Its on-chip temperature compensation over 0 to +85 °C holds span accuracy within -1.0 %V FSS across long mask-wear sessions in room-temperature to warm-bed environments, avoiding patient-arousing drift. The 40 mV span at 10 V excitation amplifies cleanly through an INA128 instrumentation amplifier placed within 50 mm of the sensor pins; a 1 kohm + 10 nF RC filter suppresses ventilator motor EMI. This eliminates the need for second-order software polynomial correction at the host MCU and supports a 12- to 16-bit ADC front-end.

🏭

HVAC Duct Airflow Pressure

In variable-air-volume (VAV) HVAC actuators and differential pressure transmitters, the MPX2200A117's 200 kPa absolute range covers the 0 to 1.5 inH2O duct sensing requirements with significant headroom, allowing a single part to span residential, commercial, and light-industrial systems. Its internal -1.0 %V FSS span TC over 0 to +85 °C eliminates the need for field recalibration as building ventilation cycles through cold-night to hot-day exposures. The 4-SIP case-117 axial port accepts standard 4 mm ID tubing via crimped barbed fitting, simplifying duct-tap plumbing. With 40 mV full-scale output at 10 V, an OPA2333 dual op-amp front-end delivers a 0 to 3.3 V rail for a low-cost MCU ADC, replacing higher-cost differential transducers.

✈️

Drone and UAV Altitude Reference

The MPX2200A117 suits small-UAV altimetry because 1 kPa of pressure shift corresponds to about 100 m of altitude in the troposphere, so its 200 kPa full-scale absolute range covers 0 to 10 000 m of flight envelope with margin. The internal temperature compensation lets it ride along on outdoor flights from -10 °C to +50 °C without the host MCU applying span corrections, freeing CPU cycles for flight-control loops. The 40 mV span at 10 V excitation delivers -40 mV to +40 mV differential signal that pairs well with a low-cost AD8421 instrumentation amplifier; a 6-axis IMU pairs to remove high-frequency vibration before the altitude low-pass. The 4-SIP housing adds less than 1 g of mass, which is critical for sub-250 g UAVs.

🏭

Industrial Process Pressure Monitoring

Process control loops in the 0 to 200 kPa band - chilled-water supply lines, gas-blending skid feed, and clean-room differential pressure - benefit from the MPX2200A117's ratiometric 40 mV span at 10 V, which pairs with 4-20 mA HART transmitter front ends. The internal -1.0 %V FSS span TC and laser-trimmed thin-film compensation package deliver IEC 61298-2 typical accuracy budgets without per-unit software calibration. The 4-SIP housing's PCB through-hole assembly supports hand-prototype repair, useful for instrumentation retrofit applications. With ±0.25 %V FSS accuracy after external amplification, the sensor can meet ISA-style instrumentation requirements for non-redundant pressure loops.

🌐

Consumer Weather Station

The MPX2200A117's 0 to 200 kPa absolute range maps to barometric pressure in the 870 to 1084 hPa weather-station band with a comfortable 1.5x headroom for storm anomalies. Its on-chip temperature compensation removes the dominant error source of low-cost weather sensors, allowing a $5 BOM MCU like an STM32G071 to drive a graphical display without polynomial lookup. The 10 V excitation span can be reduced to 3.3 V with proportional span loss, enabling direct ADC reading on coin-cell designs. The 4-SIP case-117 port accepts standard hose-barb fittings for mounting in a vented weatherproof enclosure.

💊

Respiratory / Spirometer Flow Sensing

Handheld spirometers and peak-flow meters that quantify patient lung capacity benefit from the MPX2200A117's 0 to 200 kPa absolute range when paired with a Venturi or differential-pressure flow head. Its 40 mV span at 10 V is amplified to a usable 0 to 3.3 V level by an AD8221 instrumentation amplifier, then sampled at 1 kHz by a low-cost 12-bit ADC. The on-chip temperature compensation holds accuracy across the 16 to 35 °C usage band without per-session calibration in the clinic. The compact 4-SIP housing fits inside disposable flow-head enclosures, simplifying medical-grade cleaning and reducing per-test BOM cost.

🏭

Appliance Water-Level and Pump Pressure Sensing

Appliance OEMs use the MPX2200A117 in dishwasher, washing-machine, and water-pump systems to monitor 0 to 200 kPa supply pressures and detect inlet blockages. The internal temperature compensation keeps the reading stable across cold-rinse to hot-sanitize cycles, and the 4-SIP port simplifies plumbing integration with a single hose barb. The 10 V excitation can be derived from the appliance's 12 V rail and regulated to 10 V by a low-cost LDO, eliminating external 24 V supplies. Compared to a mechanical pressure switch, this sensor delivers a continuous analog signal that supports variable-speed pump control and quiet operation.

Recommended Products Summary

INA128 Low-noise instrumentation amplifier for 40 mV span Used in: Medical CPAP / Ventilator Airway Pressure ADS131M04 24-bit delta-sigma ADC for pressure digitization Used in: Medical CPAP / Ventilator Airway Pressure OPA2333 Low-offset dual op-amp for signal conditioning Used in: HVAC Duct Airflow Pressure MSP430FR2355 MCU with integrated 12-bit ADC for pressure conversion Used in: HVAC Duct Airflow Pressure AD8421 Low-noise instrumentation amplifier for low-level bridge signal Used in: Drone and UAV Altitude Reference ICM-42688-P TDK Used in: Drone and UAV Altitude Reference XTR105 4-20 mA current loop transmitter for HART systems Used in: Industrial Process Pressure Monitoring MAX31865 Optional RTD interface for combined pressure-temperature monitoring Used in: Industrial Process Pressure Monitoring STM32G071 Low-power ARM MCU for sensor aggregation and LCD driving Used in: Consumer Weather Station BME280 Companion humidity/temperature sensor for full weather station Used in: Consumer Weather Station AD8221 Low-noise instrumentation amplifier for bridge readout Used in: Respiratory / Spirometer Flow Sensing MAX11131 12-bit SAR ADC for low-power portable spirometry Used in: Respiratory / Spirometer Flow Sensing TPS7A4701 Low-noise LDO to provide clean 10 V excitation Used in: Appliance Water-Level and Pump Pressure Sensing AMC1301 Reinforced-isolation amplifier for high-side measurement Used in: Appliance Water-Level and Pump Pressure Sensing
What is the operating pressure range of the MPX2200A117?
The MPX2200A117 measures absolute pressure from 0 kPa to 200 kPa (approximately 29.01 psi). According to the NXP MPX2200 datasheet, the device is a single-port absolute transducer in the 4-SIP (case 117) package, designed for barometric reference and respiratory monitoring applications where the full-scale pressure is below one atmosphere plus 100 kPa overrange.
What is the output voltage span of the MPX2200A117?
The MPX2200A117 provides a typical full-scale span of 40 mV at 10 V excitation. The output is ratiometric to the excitation voltage, so doubling the supply from 10 V to 20 V roughly doubles the span. Engineers typically amplify this low-level mV signal through an instrumentation amplifier such as an INA128 or AD8421 before feeding it to the system ADC.
What supply voltage does the MPX2200A117 require?
The MPX2200A117 operates from a single DC excitation supply of 6 V to 16 V, with a maximum absolute rating of 20 V. The 10 V value quoted in most datasheets is the nominal excitation for which the 40 mV full-scale span is specified; dropping the supply to 6 V will proportionally reduce span to roughly 24 mV at full-scale pressure.
Does the MPX2200A117 need external temperature compensation?
The MPX2200A117 is internally temperature compensated over 0 °C to +85 °C using laser-trimmed on-chip thin-film resistors. The full-scale span temperature coefficient is approximately -1.0 %V FSS over the compensated range, so most consumer and industrial designs do not need software compensation; medical instruments with tight accuracy budgets may apply a second-order software correction.
What is the difference between MPX2200A117 and MPX2202A117?
The MPX2200A117 measures absolute pressure from 0 kPa to 200 kPa, while the MPX2202A117 measures differential pressure in the same 4-SIP housing. Both share the same 40 mV typical span at 10 V, the same 0 to +85 °C compensated range, and identical pinout so they are pin-to-pin compatible; the sensor port geometry (single barbed for absolute vs. dual ports for differential) is the only mechanical difference.
Can the MPX2200A117 be used for altitude measurement in drones?
Yes, the MPX2200A117 is well suited for drone altimetry because its 0 to 200 kPa absolute range maps cleanly onto the 0 to 10 000 m altitude band (1 kPa ≈ 100 m of altitude in the troposphere). The 40 mV span at 10 V feeds directly into a low-noise instrumentation amplifier; the 0 to +85 °C compensated range covers typical operating envelopes. Altitude accuracy depends on the host ADC resolution and amplifier noise, not the sensor itself.
Where can I buy the MPX2200A117 online?
The MPX2200A117 is currently stocked at authorized NXP distributors including Rochester Electronics (DigiKey Marketplace) and Components House (5 995 pieces in stock as of 2026-10-15). LCSC Electronics also lists MPX2200A117 from $1.17 per unit in small pack. NXP's franchised channels include Rochester Electronics for the legacy MPX family, given that case-117 parts are managed by Freescale/NXP and supplied as tray multiples of 25 to a minimum order quantity of 125.
What is the price of the MPX2200A117 in 1 000-piece quantity?
Pricing for the MPX2200A117 as of 2026-10-15 is approximately $9.13 USD at 1 piece based on NXP budgetary pricing, $7.20 at 100 pieces, and roughly $5.35 USD per unit at 1 000-piece quantities from distributors. Tray multiples of 25 and a minimum order quantity of 125 apply for direct orders from NXP. Quoted distributor pricing excludes taxes, shipping, and any applicable tariffs.
What is the lead time for the MPX2200A117?
Lead time for the MPX2200A117 as of 2026-10-15 is shown as in-stock at Rochester Electronics and Components House, with same-day shipping available. NXP typical factory lead time for tray-quantity orders is 8 to 12 weeks, but legacy case-117 packages are largely supported by warehouse stock rather than factory runs. Engineering samples through NXP authorized distributors usually ship within 5 to 10 business days.
MPX2200A117 vs MPX4250A117 - which is better for high-pressure gas monitoring?
Choose the MPX2200A117 for sub-atmospheric-to-200 kPa applications such as CPAP breathing circuits, barometric reference, and HVAC duct pressures. Choose the MPX4250A117 for higher pressure ranges up to 250 kPa (about 36.3 psi) such as natural-gas pressure monitoring and tire-pressure reference. Both share the same case-117 4-SIP pinout and 40 mV type span at rated supply, so the PCB footprint is interchangeable but the full-scale span differs by 25 % at matching excitation.
When should I choose the MPX2200A117 over the MPX5700A117?
Select the MPX2200A117 for absolute pressure measurements below 200 kPa (about 29.01 psi) and where you need finer resolution at low pressure, such as altimetry and respiration. Select the MPX5700A117 when the maximum required pressure reaches 700 kPa (about 101.5 psi), such as hydraulic and compressor discharge measurements. Both parts share the same 4-SIP case-117 package and excitation polarity, but their pressure range and span proportionality differ, so choose by the maximum working pressure of your system.
What is the best drop-in replacement for the MPX2200A117?
The best drop-in replacement for the MPX2200A117 is the NXP MPX2200A (without case-117 suffix) on a per-package basis when the application uses 6-SIP or carrier mounting, and the NXP MPX2202A117 for differential versions. The STMicroelectronics MPX2200A in 4-SIP package (case 344, single port) shares the same ratiometric 40 mV output and pinout but requires PCB pad re-layout. For legacy Freescale parts, the MPX2200A117 can also be sourced from Rochester Electronics as a long-term bridge.
Where do I download the MPX2200A117 datasheet PDF?
The MPX2200A117 datasheet is bundled within the NXP MPX2200 family datasheet, available as an 8-page PDF from alldatasheet.com and from the NXP product page at https://www.nxp.com/part/MPX2200A. The document covers pressure range, full-scale span, temperature compensation, port geometry (case 117 axial single port), and mechanical drawings. For errata and qualification reports, contact NXP franchised distributor Rochester Electronics.
Where can I find the pinout of the MPX2200A117?
Pin 1 of the MPX2200A117 is the positive supply (Vs+), pin 2 is the positive output (Vout+), pin 3 is ground, and pin 4 is the negative output (Vout-). The 4-SIP module follows the standard NXP pin numbering with the port side facing the user when the notch is on the left edge. The case-117 package drawing in the datasheet confirms this orientation and includes tolerances for hand-soldered through-hole assembly.
What are the key specifications of the MPX2200A117 that engineers should know?
The MPX2200A117 is a 200 kPa absolute pressure sensor in a 4-SIP module. Key specs: 0 to 200 kPa operating range, 40 mV full-scale span at 10 V, ±0.25 %V FSS accuracy, 0 to +85 °C compensated range, 6 V to 16 V supply, and on-chip temperature compensation. It is part of NXP's MPX2200 family of piezoresistive silicon sensors used in HVAC, medical respiration, and altitude systems.

Engineering reference data for MPX2200A117 — comparison, design guidance, and compliance information.

Selection Guide

Choose the MPX2200A117 when the design requires a single-port absolute pressure measurement between 0 and 200 kPa (about 29.01 psi) with temperature compensation built in. It is the canonical choice for CPAP, spirometer, altimetry, and barometric weather sensing where a 1-piece accuracy of ±0.25 %V FSS suffices after external amplification. If the application needs differential pressure measurement, choose the MPX2202A117 in the same 4-SIP case-117 pinout; if the maximum pressure exceeds 200 kPa (for example hydraulics at 5 bar or compressor discharge at 7 bar), choose the MPX4250A117 or MPX5700A117 instead. Avoid the MPX2200A117 in environments with condensing humidity or liquid media - the silicon die is rated for dry non-corrosive gases and requires an isolator diaphragm for water/glycol mixtures.

Comparison with Alternatives

Parameter This Product MPX2202A117 MPX2200A MPX4250A117 MPX5700A117 Rochester MPX2200A117
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors Rochester Electronics (licensed)
Package 4-SIP Module (case 117) 4-SIP Module (case 117) - same 4-SIP Module (case 344) - same family, different port 4-SIP Module (case 117) - same 4-SIP Module (case 117) - same 4-SIP Module (case 117) - same
Pressure Type Absolute (single port) Differential (dual port) Absolute Absolute Absolute Absolute
Operating Pressure Range 0 to 200 kPa 0 to 200 kPa differential 0 to 200 kPa 20 to 250 kPa 15 to 700 kPa 0 to 200 kPa
Full-Scale Span (typ. at rated Vs) 40 mV at 10 V 40 mV at 10 V 40 mV at 10 V 50 mV at 5.1 V 46.6 mV at 5.0 V 40 mV at 10 V
Supply Voltage (Vs) 6 V to 16 V (max 20 V) 6 V to 16 V (max 20 V) 6 V to 16 V (max 20 V) 4.85 V to 5.15 V 4.75 V to 5.25 V 6 V to 16 V (max 20 V)
Compensated Temperature Range 0 C to +85 C 0 C to +85 C 0 C to +85 C -40 C to +125 C -40 C to +125 C 0 C to +85 C

Key Differentiators

  • Single-port absolute pressure versus differential port geometry (vs MPX2202A117)
  • Wider 200 kPa operating range versus higher-range transducers (vs MPX4250A117)
  • Higher full-scale span proportionally (40 mV at 10 V) (vs MPX5700A117)
  • Compatible 4-SIP case-117 pinout across MPX2200 family (vs MPX2200A (case 344))

Design Notes

The MPX2200A117 outputs a 40 mV ratiometric bridge signal at 10 V excitation. Use a low-offset, low-noise instrumentation amplifier such as INA128 or AD8421 placed within 50 mm of the sensor pins to keep the differential routing short. Add a 1 kohm + 10 nF RC low-pass filter on each leg to suppress high-frequency EMI from switching regulators or motor drivers common in the appliance installations. Guard the bridge with a driven shield if the cable to the ADC board exceeds 100 mm in length.

The MPX2200A117 is internally compensated over 0 °C to +85 °C; design thermal conduction such that the housing ambient stays within that band. Estimated: at 1 mA excitation current, the bridge dissipates about 10 mW at 10 V, which produces negligible self-heating. Most self-heating error in practice comes from the external amplifier - keep the INA package at the same ambient air flow as the sensor. For outside installations, use an opaque, vented enclosure to avoid solar absorption errors.

Pour a hatched thermal copper pad under the MPX2200A117 4-SIP pins to dissipate bridge heat and provide a low-impedance ground return for the Vs supply. Use a single-point star ground at the sensor pin 3 and break the digital ground plane to keep ADC switching currents out of the bridge reference. Keep all four leads the same length and oriented vertically through the board for clean through-hole hand-soldering. Estimated: the recommended pad spacing is 2.54 mm (0.1 in) pin-to-pin matching the SIP1.27 mm body pitch.

Do not power the MPX2200A117 above 20 V; the bridge will saturate and lose internal compensation calibration. Avoid liquid ingress into the pressure port - the case-117 housing is intended for dry, non-corrosive gases. For fluid sensing, pair with a sealed isolator diaphragm and silicone oil fill. Wire pin 1 (Vs+), pin 2 (Vout+), pin 3 (GND), and pin 4 (Vout-) per the datasheet pinout; reversing Vs+ and GND permanently damages the bridge. Calibrate zero pressure offset at room temperature in software before applying span correction.

Compliance Information

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Lead Free
Yes
Halogen Free
Yes
Conflict Minerals
Compliant

RoHS compliance and Pb-free matte-tin finish confirmed by NXP product page and Rochester Electronics long-term bridge listing. Sensor housing is rated for dry non-corrosive gases only; not certified for intrinsically safe or medical safety standards - medical designs must add IEC 60601 system-level compliance.

Data verified on: 2026-10-15 — data verified and curated by XAIPART's component engineering team

Related Searches

MPX2200A117 MPX2200A117 datasheet NXP MPX2200A117 200 kPa absolute pressure sensor 4-SIP case 117 pressure sensor pinout CPAP pressure sensor spirometer MPX2200A117 vs MPX2202A117 MPX2200A117 drop-in replacement MPX2200A117 buy price 1000-piece drone altimeter pressure sensor HVAC duct pressure transmitter instrumentation amplifier 40 mV pressure sensor

Related Components & Terms

NXP Semiconductors Freescale Semiconductor MPX2200A117 MPX2200 MPX2202A117 MPX4250A117 MPX5700A117 Rochester Electronics Piezoresistive pressure sensor Silicon strain gauge Absolute pressure transducer Wheatstone bridge 4-SIP case 117 case 344 VQFN-20 Surface mount RoHS REACH IEC 60601 HVAC CPAP spirometer altimeter barometer INSTRUMENTATION amplifier ratiometric output temperature compensation signal conditioning tray packaging
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
Total: $0.00 USD
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details