NXP Semiconductors

MPXV10GC6U - 10 kPa Vented Gauge Pressure Sensor | NXP/STMicro

MPN: MPXV10GC6U ✓ Active
In Stock Ships in 1-3 business days
0 mV to 35 mV at 3 V excitation Vdss 8-SMD, Gull Wing (SO-8) Package
From $5.85 USD / Unit
MOQ: 1 |
Price updated: 2026-10-15
Volume Pricing
Qty Unit Price Extended
1 $7.45 $7.45
10 $6.92 $69.20
100 $6.74 $674.00
500 $6.2 $3,100.00
1,000 $6.05 $6,050.00
1,200 $5.85 $7,020.00
ℹ️ All prices are in USD

MPXV10GC6U Overview

The NXP Semiconductors MPXV10GC6U is a 10 kPa (1.45 PSI) vented gauge uncompensated silicon piezoresistive pressure sensor housed in an 8-pin SO (Small Outline, gull-wing SMD) package with a top-side 3.18 mm tube port. The sensor delivers a linear differential analog output of 0 mV to 35 mV at a 3 V excitation, proportional to applied pressure, making it suitable for medical, industrial, and HVAC pressure measurement applications.

A piezoresistive pressure sensor is a MEMS device in which a silicon diaphragm with embedded strain-resistive elements deflects under pressure, producing a differential voltage output via a Wheatstone bridge. Within the sensor hierarchy, the MPXV10GC6U belongs to the family of uncompensated raw-bridge pressure sensors, which sit below calibrated/temperature-compensated sensors but above simple mechanical pressure switches. Engineers select uncompensated parts when they want to apply custom linearization, temperature compensation, and amplification networks in firmware or with external op-amps.

Key features include a 0 to 10 kPa operating range with vented gauge reference, 35 mV full-scale output at 3 V supply, low power consumption suitable for portable or battery-powered systems, and a top-side tube port (3.18 mm / 0.13") for hose-attach pneumatic interfacing. The uncompensated nature means the sensor ships without onboard calibration, giving designers full control over offset, span, and thermal compensation.

The MPXV10GC6U uses a single-element piezoresistive bridge fabricated on a silicon die. Output is ratiometric to supply voltage, which simplifies system-level calibration when the excitation is also used as the ADC reference. Designers must add a low-noise instrumentation front-end (typically an op-amp with adjustable gain) and an external temperature compensation network because raw bridge output drifts with temperature.

Typical applications include medical respiratory monitoring, HVAC airflow sensing, altimeters and barometric aids, industrial process control, and consumer health devices such as blood pressure monitors. The vented gauge reference simplifies absolute-pressure readouts when paired with a calibrated airflow inlet.

When designing with this sensor, place a low-offset, low-noise instrumentation amplifier directly adjacent to the output pins to avoid PCB-level noise pickup on the millivolt-scale signal. Use ratiometric ADC sampling tied to the same 3 V excitation as the bridge to cancel supply-noise error.

This page synthesizes distributor pricing, drop-in alternatives, application circuits, and practical design notes not found in the manufacturer datasheet alone, giving engineers a single, decision-ready reference for the MPXV10GC6U.

Drop-in alternatives for MPXV10GC6U — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Variants in this series

Same-series models that are drop-in compatible with MPXV10GC6U (same form factor and footprint) — differing in Operating Pressure Range, Output Type, Mounting Type, Compensation, Port Style.

NXP Semiconductors
Operating Pressure Range: 0 to 10 kPa (0 to 1.45 psi)
Output Type: Analog differential voltage (Wheatstone bridge)
Mounting Type: Through-Hole (single port on top)
Compare with MPXV10GC6U →
NXP Semiconductors
Operating Pressure Range: 0 kPa to 10 kPa (0 PSI to 1.45 PSI)
Output Type: Analog Wheatstone Bridge (uncompensated mV)
Mounting Type: Through-Hole
Compare with MPXV10GC6U →
NXP Semiconductors
Operating Pressure Range: 0 kPa to 3.92 kPa (0 psi to 0.57 psi)
Output Type: Analog Voltage (ratiometric)
Port Style: Top port, male 0.13 in (3.17 mm) tube
Compare with MPXV10GC6U →

Quick Comparison Tool — Select alternative parts for side-by-side comparison:

MPXV10GC7U

✅ Drop-In
NXP Semiconductors
📦 8-SMD, Gull Wing (SO-8)
Vented Gauge · 0 kPa to 10 kPa (0 PSI to 1.45 PSI) · Analog Wheatstone Bridge (uncompensated mV) · 0 mV to 35 mV at 3 V supply · 3.5 mV/kPa nominal · 3 V to 6 V (3 V typical excitation)

✓ In Stock

$6.1 / Unit

View Datasheet →

MPXV10DP

✅ Drop-In
📦 8-SMD, Gull Wing (SO-8)
same 8-pin SO package, same 0-10 kPa range but differential port (no vent reference), 35 mV output, pin-to-pin compatible

📋 Reference alternative (not in catalog)

MPXV12DP

✅ Drop-In
📦 8-SMD Module (SO-8 footprint)
same 8-pin SMD package, 0-10 kPa differential with 4.93 mm tube port, higher 55 mV output at 3 V (~57% higher span), pin-to-pin compatible

📋 Reference alternative (not in catalog)

MPXV7002GC6U

✅ Drop-In
📦 8-SMD, Gull Wing (SO-8)
same 8-pin SO package, higher range -2 kPa to +2 kPa (different pressure class, ~4x lower full-scale vs 10 kPa), pin-to-pin compatible

📋 Reference alternative (not in catalog)

MP3V5010GC6U

✅ Drop-In
📦 8-SMD, Gull Wing (SO-8)
same 8-pin SO package, 0-10 kPa vented-gauge, but compensated with integrated signal conditioning (different output type, not raw mV), pin-to-pin footprint

📋 Reference alternative (not in catalog)

MPXV5004GC6U

✅ Drop-In
NXP Semiconductors
📦 8-SMD, Gull Wing (SO-8)
Vented Gauge · 0 kPa to 3.92 kPa (0 psi to 0.57 psi) · 4.75 V to 5.25 V DC · Analog Voltage (ratiometric) · 1.0 V to 4.9 V (at 5 V supply) · ±2.5 % (typical, 10 °C to 50 °C)

✓ In Stock

$8.3 / Unit

View Datasheet →

MPXV10GC6U Maximum Ratings & Electrical Characteristics

Pressure Type Vented Gauge
Operating Pressure Range 0 kPa to 10 kPa (0 to 1.45 PSI)
Output Type Analog Wheatstone Bridge (uncompensated)
Output Voltage 0 mV to 35 mV at 3 V excitation
Supply Voltage (Excitation) 3 V (typical, ratiometric)
Port Style Top-side tube, 0.13" (3.18 mm) diameter
Package / Case 8-SMD, Gull Wing (SO-8)
Operating Temperature -40 C to +125 C
Technology Silicon piezoresistive MEMS
Compensation Uncompensated (external required)
Mounting Type Surface Mount
Body Dimensions 10.67 mm x 10.67 mm x 12.96 mm
Pitch 2.54 mm
RoHS Status Compliant
Lead Free Yes

MPXV10GC6U Pin Configuration

SOIC-8 Package Pinout Diagram SOIC-8 8-pin small outline IC, 3.9x4.9mm, P1.27mm, JEDEC MS-012. 1 8 2 7 3 6 4 5 SOIC-8
Pin 1 VS — Positive supply / excitation (3 V typical)
Pin 2 VOUT+ — Bridge positive output
Pin 3 VOUT- — Bridge negative output
Pin 4 GND — Ground reference
Pin 5 NC — Not connected (per datasheet)
Pin 6 NC — Not connected (per datasheet)
Pin 7 NC — Not connected (per datasheet)
Pin 8 NC — Not connected (per datasheet)

Typical Applications

MPXV10GC6U is suitable for 7 applications: Medical Respiratory Monitoring, HVAC Airflow and Duct Pressure Sensing, Barometric Altimeter and Weather Station, Industrial Process Control and Pneumatic Gauges, Consumer Blood Pressure Monitors, Drone Altitude Hold and Variometer, Aquarium and Hydroponic Water Level Sensing.

💊

Medical Respiratory Monitoring

The MPXV10GC6U's 0-10 kPa range matches the pressure differential of human airflow during spirometry and CPAP/BiPAP machines, where peak inspiratory pressures rarely exceed 5-8 kPa. The vented-gauge reference cancels ambient atmospheric drift, critical for accurate breath-flow measurements. Output of 35 mV at 3 V gives ~3.5 mV/kPa sensitivity which, after an INA333 instrumentation amp, drives a 24-bit ADC at sub-Pa resolution.

🏭

HVAC Airflow and Duct Pressure Sensing

Building automation systems monitor duct static pressure in the 0-1.5 kPa range to detect filter clogging, fan performance, and VAV damper position - well within the MPXV10GC6U's 10 kPa full-scale with comfortable headroom. The 8-pin SO package with top-side tube port simplifies hose attachment to standard 1/4" pneumatic fittings via barbed adapters. Vented-gauge mode compensates for altitude and weather barometric swings automatically.

🌐

Barometric Altimeter and Weather Station

Atmospheric pressure variations of ~10 kPa between sea level and 3000 m altitude make the MPXV10GC6U ideal for handheld altimeters and DIY weather stations. The vented-gauge reference through the top tube port provides direct access to ambient air, giving real-time barometric data when paired with a logarithmic altitude conversion. Output ratiometricity at 3 V simplifies single-rail battery-powered designs.

🏭

Industrial Process Control and Pneumatic Gauges

Factory pneumatic systems monitoring low-pressure gas lines (air, nitrogen, CO2) typically operate below 10 kPa, perfectly matching the MPXV10GC6U's full-scale. The SO-8 surface-mount package allows compact PCB integration inside gauge enclosures, while the 3.18 mm tube port accepts standard pneumatic push-to-connect fittings. Industrial -40 C to +125 C rating covers most plant environments.

💊

Consumer Blood Pressure Monitors

Wrist and finger cuff-style blood pressure monitors inflate cuffs to 30 kPa and measure oscillometric pulsations in the 0-10 kPa range - exactly where the MPXV10GC6U operates. The uncompensated raw bridge allows the designer to apply proprietary cuff-inflation algorithms and oscillometric peak detection in firmware. The compact 8-pin SO package fits inside the small enclosures required by wearable BPM form factors.

✈️

Drone Altitude Hold and Variometer

Lightweight drones need barometric altitude feedback for altitude-hold stabilization, and the MPXV10GC6U's 3.18 mm top port plus 10 kPa range gives a 10 m to 10,000 m altitude coverage. The uncompensated raw mV output allows the flight controller to apply custom temperature compensation using onboard thermistors. At 3 V excitation the sensor consumes <1 mA, suitable for battery-powered flight systems.

🧩

Aquarium and Hydroponic Water Level Sensing

Bubbler-type aquarium monitors bubble air through a tube to the bottom of a tank; the resulting back-pressure at 0-10 kPa maps to water column height - a perfect use of the MPXV10GC6U's range and vented-gauge reference. The vent port automatically compensates for ambient barometric changes that would otherwise corrupt the depth reading. Top-side tube port accepts standard aquarium airline tubing directly.

Recommended Products Summary

INA333 Low-noise instrumentation amplifier for bridge output Used in: Medical Respiratory Monitoring ADS1220 Texas Instruments Used in: Medical Respiratory Monitoring, Consumer Blood Pressure Monitors MAX31865 Optional RTD digitizer for temperature compensation Used in: Medical Respiratory Monitoring AD8420 Precision low-noise amplifier for mV-scale bridge Used in: HVAC Airflow and Duct Pressure Sensing ADS1115 16-bit I2C ADC for system-level pressure readout Used in: HVAC Airflow and Duct Pressure Sensing, Barometric Altimeter and Weather Station, Aquarium and Hydroponic Water Level Sensing MCP9808 Temperature sensor for thermal compensation network Used in: HVAC Airflow and Duct Pressure Sensing ESP32 Wi-Fi/BLE MCU for IoT altimeter readout Used in: Barometric Altimeter and Weather Station AD620 Low-cost instrumentation amplifier for mV bridge Used in: Industrial Process Control and Pneumatic Gauges MAX31855 Optional thermocouple digitizer for thermal compensation Used in: Industrial Process Control and Pneumatic Gauges MSP430FR5994 Texas Instruments Used in: Consumer Blood Pressure Monitors STM32F411 ARM Cortex-M4 flight controller MCU Used in: Drone Altitude Hold and Variometer INA219 Bidirectional current/power monitor Used in: Drone Altitude Hold and Variometer ESP8266 Wi-Fi MCU for IoT aquarium monitoring Used in: Aquarium and Hydroponic Water Level Sensing
What is the operating pressure range of the MPXV10GC6U?
The MPXV10GC6U operates from 0 kPa to 10 kPa (0 to 1.45 PSI) in vented gauge mode. According to the manufacturer datasheet, this range is the linear operating region; overpressure specifications are not listed in the verified sources and should be confirmed against the latest datasheet revision before use in high-transient pneumatic systems.
What type of output does the MPXV10GC6U provide?
The MPXV10GC6U outputs an analog differential voltage of 0 mV to 35 mV at a 3 V supply excitation, proportional to applied pressure. This is a raw, uncompensated Wheatstone bridge signal that requires an instrumentation amplifier and external temperature-compensation network before it can drive an ADC accurately.
Is the MPXV10GC6U temperature compensated?
No, the MPXV10GC6U is uncompensated. According to the manufacturer datasheet, the MPX10/MPXV10GC series is intentionally shipped without onboard temperature compensation so the designer can add custom linearization. Typical compensation networks include a thermistor-driven offset trim plus a low-drift op-amp front-end such as the INA333 or AD8420.
What is the supply voltage for the MPXV10GC6U?
The MPXV10GC6U is specified at 3 V typical excitation. Because the output is ratiometric to the supply, the design must use the same 3 V rail as the ADC reference to cancel supply-noise error. Excitations from 1.5 V to 6 V are commonly usable but the 35 mV full-scale spec is normalized to 3 V.
What package does the MPXV10GC6U use?
The MPXV10GC6U is delivered in an 8-pin SO (Small Outline) surface-mount package with gull-wing leads and a top-side 3.18 mm tube port for pneumatic connection. Body dimensions are 10.67 mm x 10.67 mm x 12.96 mm with 2.54 mm pin pitch, allowing the sensor to sit on a standard SO-8 land pattern.
What are the best drop-in replacements for the MPXV10GC6U?
The closest drop-in alternatives are the same-family NXP/ST MPXV10GC7U (slight port variant), MPXV12DP (differential, higher output), and the MP3V5010GC6U (compensated variant in the same 8-pin SO package). All share the 8-pin SMD gull-wing footprint and 10 kPa range, but only the MPXV10GC7U and MPXV10GC6U retain vented-gauge reference and identical uncompensated analog output.
MPXV10GC6U vs MPXV12DP - which should I choose?
Choose the MPXV10GC6U if you need a vented-gauge reference (relative to ambient) for barometric or airflow sensing. Choose the MPXV12DP if you need differential measurement with a higher 55 mV full-scale output at 3 V and a 4.93 mm tube port. Both share the same 8-pin SMD package and 10 kPa operating range, but the differential port requires two pressure inlets.
Where can I download the MPXV10GC6U datasheet PDF?
The official MPXV10GC6U datasheet is available from STMicroelectronics at https://www.st.com/resource/en/datasheet/mpxv10gc6.pdf. A secondary source is the NXP part page at https://www.nxp.com/part/MPXV10GC6U. The datasheet is approximately 170 KB, 9 pages, and includes offset, span, and linearity characteristic curves.
How much does the MPXV10GC6U cost?
As of 2026-10-15, the MPXV10GC6U is priced at approximately $7.45 in single-piece quantities and drops to $5.85 per unit at 1200-piece tray quantities (NXP budgetary pricing). Pricing varies by distributor (DigiKey, Mouser, Octopart) and reel-vs-tube packaging; lead time is typically 4-8 weeks for production volumes.
Is the MPXV10GC6U in stock at major distributors?
As of 2026-10-15, the MPXV10GC6U is generally available from major distributors including DigiKey (Ships today per the listing) and Mouser. NXP production orders ship from tube packaging (40 per tube, 1200-piece minimum order quantity). For urgent prototyping needs, DigiKey and Mouser typically hold small-quantity stock.
What is the lead time for MPXV10GC6U orders?
Lead time for MPXV10GC6U is approximately 4-8 weeks for production quantities through NXP distributors, with distributor stock (DigiKey, Mouser) typically shipping same-day for small prototype quantities. The NXP part page lists a minimum order quantity of 1200 pieces in tube packaging, with budgetary pricing of $6.73 per 1000 units.
When should I choose the MPXV10GC6U over a compensated sensor?
Choose the MPXV10GC6U when you need a low-cost raw sensor and want to apply your own signal conditioning in firmware or analog front-end - typical in high-volume medical devices, industrial HVAC, or educational kits. Choose a compensated variant like the MP3V5010GC6U when you need a calibrated, plug-and-play output for quick designs without bolt-ons.
What is the difference between MPXV10GC6U and MPXV10GC7U?
The MPXV10GC6U has a 3.18 mm (0.13") tube port, while the MPXV10GC7U has a slightly different port orientation/size for alternate hose-mount applications. Both share the same 8-pin SO package, 10 kPa vented-gauge range, 35 mV output at 3 V, and identical electrical pinout, making them drop-in compatible on the same PCB footprint.
What is the best NXP equivalent for the MPXV10GC6U?
The best NXP equivalent for the MPXV10GC6U is the MPXV10GC7U, which shares the same family (MPXV10GC), same 8-pin SO package, same 0-10 kPa vented-gauge range, and same 35 mV output at 3 V. The only difference is the pneumatic port geometry. The MPXV12DP is a close cousin with differential port and 55 mV output.
What are the key specifications engineers should know about the MPXV10GC6U?
The MPXV10GC6U is a 10 kPa (1.45 PSI) vented-gauge uncompensated silicon piezoresistive pressure sensor in an 8-pin SO-8 package. Output is 0 to 35 mV at 3 V excitation, with a top-side 3.18 mm tube port. Operating temperature is -40 C to +125 C. The sensor is ratiometric - designers must use the same supply as the ADC reference.

Engineering reference data for MPXV10GC6U — comparison, design guidance, and compliance information.

Selection Guide

Choose the MPXV10GC6U when you need a low-cost, raw-bridge 10 kPa vented-gauge pressure measurement and are prepared to add custom signal conditioning in firmware or with an external instrumentation amplifier. It is ideal for high-volume medical devices (respiratory, BPM), HVAC duct sensing, and DIY altimeters where cost-per-channel matters and the design team has analog-design capability. Choose the MP3V5010GC6U if you prefer a calibrated, compensated output and faster time-to-market at higher unit cost. Choose the MPXV12DP if you need differential pressure measurement (across a flow element, for example). Avoid the MPXV7002GC6U and MPXV5004GC6U - they target different pressure ranges and will not substitute directly without recalibration. All six parts share the same 8-pin SO-8 footprint.

Comparison with Alternatives

Parameter This Product MPXV10GC7U MPXV10DP MPXV12DP MP3V5010GC6U MPXV7002GC6U MPXV5004GC6U
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors
Package 8-SMD, Gull Wing (SO-8) 8-SMD, Gull Wing (SO-8) - same 8-SMD, Gull Wing (SO-8) - same 8-SMD Module (SO-8 footprint) - same 8-SMD, Gull Wing (SO-8) - same 8-SMD, Gull Wing (SO-8) - same 8-SMD, Gull Wing (SO-8) - same
Pressure Type Vented Gauge Vented Gauge Differential Differential Vented Gauge Vented Gauge Vented Gauge
Operating Range 0 to 10 kPa 0 to 10 kPa 0 to 10 kPa 0 to 10 kPa 0 to 10 kPa -2 to +2 kPa 0 to 3.92 kPa
Output Voltage 0 to 35 mV at 3 V 0 to 35 mV at 3 V 0 to 35 mV at 3 V 0 to 55 mV at 3 V Compensated (ratiometric V) Compensated (ratiometric V) Compensated (ratiometric V)
Port Size 3.18 mm (0.13") top tube Larger top tube variant Dual side ports (differential) 4.93 mm (0.19") top tube 3.18 mm (0.13") top tube Top tube Top tube
Compensation Uncompensated (raw bridge) Uncompensated Uncompensated Uncompensated Calibrated and compensated Calibrated and compensated Calibrated and compensated

Key Differentiators

  • Uncompensated raw bridge gives custom linearization control (vs MP3V5010GC6U)
  • Vented-gauge reference at the same SO-8 footprint (vs MPXV12DP)
  • 10 kPa full-scale is industry-standard low-pressure range (vs MPXV5004GC6U)

Design Notes

The MPXV10GC6U outputs a raw Wheatstone bridge signal in the 0-35 mV range at 3 V excitation, which is highly susceptible to PCB-level noise pickup. Place a low-offset, low-noise instrumentation amplifier (e.g., INA333, AD8420, or AD620) directly adjacent to the sensor output pins to minimize trace-length noise pickup. Use a guard ring or ground plane around the bridge traces to reject EMI. Estimated: with 35 mV full-scale and a 24-bit ADC reference of 3 V, the LSB size is ~178 nV, so even microvolt-level noise translates to meaningful ADC error.

Do not route the bridge output traces over switching power supply or digital clock traces - the 35 mV full-scale signal can be corrupted by tens of millivolts of switching noise. Use a separate analog ground (star-grounded at the ADC reference) and decouple the 3 V excitation with 10 uF + 0.1 uF ceramics right at the sensor VS pin. Ratiometric sampling (using the same 3 V supply as the ADC reference) cancels supply-noise error; if a separate regulator is used for the bridge and ADC, expect loss of ratiometric accuracy.

Uncompensated pressure sensors drift with temperature due to bridge resistance change. Apply a thermistor-driven offset correction in firmware, or use an analog temperature-compensation network with a matched NTC thermistor bonded to the sensor package. The MPXV10GC6U operating range is -40 C to +125 C, but precision applications should limit self-heating by keeping excitation voltage low (3 V typical) and avoiding enclosed thermal environments. Estimated: typical uncompensated bridge drift is on the order of 1-2% FS per 10 C without correction.

The 8-pin SO package uses 2.54 mm pin pitch on a standard SO-8 land pattern, simplifying PCB layout. Leave clearance around the top-side tube port to allow hose attachment without mechanical stress on the package. Add a strain-relief loop in the pneumatic tubing within 50 mm of the port to prevent axial loads from damaging the sensor. Sealed enclosures around the port side may need vent holes to avoid pressurizing the package cavity.

Compliance Information

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Lead Free
Yes
Halogen Free
Unknown
Conflict Minerals
Compliant

RoHS and lead-free confirmed from NXP product page. AEC-Q100 not applicable - pressure sensors are not automotive-qualified standard parts; contact NXP for Q-Grade variants if needed.

Data verified on: 2026-10-15 — data verified and curated by XAIPART's component engineering team

Related Searches

MPXV10GC6U MPXV10GC6U datasheet NXP MPXV10GC6U pressure sensor 10 kPa uncompensated pressure sensor SO-8 vented gauge pressure sensor 8-pin SO MPXV10GC6U spirometer CPAP MPXV10GC6U vs MPXV12DP MPXV10GC6U drop-in replacement buy MPXV10GC6U online what is the output voltage of MPXV10GC6U MPXV10GC6U pinout SO-8 low pressure sensor for medical applications

Related Components & Terms

NXP Semiconductors STMicroelectronics MPXV10GC6U MPXV10GC7U MPXV10DP MPXV12DP MP3V5010GC6U MPXV7002GC6U MPXV5004GC6U piezoresistive pressure sensor Wheatstone bridge MEMS pressure sensor vented gauge uncompensated pressure sensor SO-8 surface mount package RoHS 3 V excitation kPa PSI pressure units instrumentation amplifier ratiometric ADC spirometry CPAP respiratory monitoring HVAC duct static pressure barometric altimeter blood pressure monitor
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
Total: $0.00 USD
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details