An RS-232 transceiver is a bidirectional interface IC that converts between single-ended logic-level signals and the bipolar signaling used by RS-232 equipment. Within the interface hierarchy, the MAX232E belongs to the RS-232 transceiver family, which is part of transceiver ICs, interface ICs, and broader semiconductor components. Two driver channels convert outgoing logic signals, while two receiver channels convert incoming RS-232 signals into CMOS-compatible levels. This makes the device suitable for equipment with two serial ports or for a single port requiring bidirectional communication.
The MAX232E family provides two transmitters and two receivers, supports operation at up to 120kbps, and meets EIA/TIA-232E and CCITT V.28 interface specifications according to the Analog Devices product page. Its integrated charge-pump circuitry permits single-supply operation, while ±15kV human-body-model ESD protection helps improve robustness at connector-facing pins. The wide 16-SOIC package is also available in common industrial assembly and inspection workflows.
Each channel uses the electrical behavior expected of a standard MAX232-family RS-232 interface. The charge pump develops the positive and negative voltages needed by the drivers, allowing the receiver side to recognize valid RS-232 levels while rejecting signals outside the specified transition region. Four active channels in one package reduce board area compared with separate single-channel transceiver packages. The device therefore balances functional integration, standard interface compatibility, and a widely supported package format.
Typical uses include industrial serial adapters, instrumentation links, point-of-sale equipment, data-acquisition systems, and control panels that connect a TTL or CMOS controller to an RS-232 port. It can also support legacy equipment migrations where the host interface still uses RS-232 and the new controller requires logic-level serial signaling. The 120kbps maximum data rate accommodates many legacy peripheral and instrumentation protocols without requiring a higher-bandwidth physical-layer transceiver.
Designers should preserve the charge-pump capacitor arrangement and place the required capacitors close to the appropriate device pins. RS-232 cable transients and ESD events occur at the connector, so the ground reference, cable routing, and interface protection arrangement also matter. Confirm the logic polarity, receiver threshold behavior, and shutdown state before substituting this device into a design with mixed RS-232 families.
This product page combines the manufacturer interface specifications, package details, verified cross-reference context, selection guidance, and practical application notes to support a faster engineering decision. It also highlights where same-package alternatives can be evaluated without changing the PCB footprint.
Аналоги без доработки для MAX232EEWE+T — тот же корпус, pin-to-pin совместимость. Компоненты в других корпусах, требующие переработки PCB, исключены.
Варианты в этой серии
Модели той же серии, совместимые без доработки с MAX232EEWE+T (тот же форм-фактор и посадочное место) — отличается по Product Type, Package, Maximum Data Rate, Interface Standard, ESD Protection.
MAX232ECWE+
✅ Прямая заменаУточнить цену
Открыть даташит →MAX232EWE+
✅ Прямая заменаУточнить цену
Открыть даташит →MAX232AEWE+
✅ Прямая замена ⚠️ Характеристики не провереныУточнить цену
Открыть даташит →MAX232ACWE+
✅ Прямая замена ⚠️ Характеристики не провереныУточнить цену
Открыть даташит →MAX232ECDWR
✅ Прямая замена ⚠️ Характеристики не провереныУточнить цену
Открыть даташит →MAX232EEWE+T Характеристики
| Product Type | RS-232 transceiver (2 drivers and 2 receivers) |
| Driver Count | 2 channels |
| Receiver Count | 2 channels |
| Duplex Mode | Full duplex |
| Напряжение питания | 5 V |
| Maximum Data Rate | 120 kbps |
| ESD Protection | ±15 kV HBM |
| RS-232 Compliance | EIA/TIA-232E |
| V.28 Compliance | CCITT V.28 |
| Voltage Generation | On-chip charge-pump circuitry |
| Корпус | 16-pin wide SOIC, 7.50 mm width |
| Число выводов | 16 pins |
| Тип монтажа | Surface-mount SMD |
| Shipping Format | Tape and reel |
Руководство по цоколевке MAX232EEWE+T в корпусе 16-pin wide soic, 7.50 mm width
Цоколевка для MAX232EEWE+T (корпус 16-pin wide soic, 7.50 mm width). Нумерация выводов, функции и схемы подключения определены в техническом описании производителя. Обратитесь к нему для точного посадочного места и рекомендаций по пайке.
Нет подробных данных о распиновке для MAX232EEWE+T.
Обратитесь к даташиту для полной конфигурации выводов.
Типичное применение
MAX232EEWE+T подходит для 6 применениеs: Industrial Serial Adapters, Data Acquisition Equipment, Point-of-Sale Terminals, Test and Measurement Instruments, Legacy Equipment Migration, Security and Access-Control Systems.
Industrial Serial Adapters
The MAX232EEWE+T fits industrial adapters that translate between a modern controller's logic-level UART and a legacy RS-232 port. Its two drivers and two receivers provide full-duplex conversion from one 5V supply, while the on-chip charge pump generates the bipolar levels required at the connector. Operation up to 120kbps supports numerous legacy instrumentation and control protocols. The ±15kV HBM ESD rating also makes the interface suitable for exposed equipment connections when the system grounding and cable arrangement are designed correctly.
Рекомендуется
Data Acquisition Equipment
Data-acquisition equipment can use the MAX232EEWE+T to connect a controller or test instrument to an RS-232-compatible peripheral. The 120kbps maximum data rate is suitable for many legacy measurement-control protocols, and the dual-driver, dual-receiver arrangement avoids separate converter packages for each direction. A single 5V rail simplifies system power design because the charge-pump circuitry generates the positive and negative driver voltages internally. Connector-side protection and ground continuity remain important when data is collected over long or noisy cables.
Рекомендуется
Point-of-Sale Terminals
Point-of-sale terminals and peripheral interfaces commonly retain RS-232 links for scales, printers, card readers, and service equipment. The MAX232EEWE+T offers two transmit and two receive channels, allowing one controller to manage multiple point-to-point serial links while retaining a compact 16-SOIC footprint. Its 5V operation and 120kbps capability align with many legacy peripherals, while ±15kV HBM protection adds interface margin for equipment that may be handled or connected frequently.
Рекомендуется
Test and Measurement Instruments
The MAX232EEWE+T can provide a compact logic-level-to-RS-232 interface in test and measurement instruments. Its 120kbps capability is appropriate for many service ports, calibration interfaces, and legacy instrument control protocols. Two drivers and two receivers allow bidirectional command and response traffic, while integrated charge-pump operation reduces the external power circuitry otherwise required for bipolar RS-232 levels. The wide SOIC package is widely supported by assembly and inspection processes, and the ESD rating is relevant to connector-accessible laboratory equipment.
Рекомендуется
Legacy Equipment Migration
Legacy equipment migrations often leave an RS-232 port in place while replacing the original controller with a modern processor or embedded module. The MAX232EEWE+T bridges that boundary by converting CMOS-level UART signals into RS-232 levels and returning received data to logic levels. Its 120kbps data-rate limit covers many established peripheral protocols, and the 5V supply simplifies connections with logic-level transceivers and microcontrollers. The same 16-SOIC footprint across several MAX232E variants can also ease mechanical reuse during qualification.
Рекомендуется
Security and Access-Control Systems
Access-control readers, controllers, and alarm interfaces may use RS-232 for short-distance command links. The MAX232EEWE+T can translate between the controller's UART logic levels and the reader's bipolar RS-232 interface, using only a single 5V supply. Two drivers and two receivers support bidirectional communication within one package, and 120kbps operation is more than adequate for many configuration and status protocols. The ±15kV HBM ESD rating is useful in access-control equipment where external cables and frequent servicing can expose connectors to electrostatic discharge.
Рекомендуется
Сводка рекомендуемых товаров
Справочные инженерные данные для MAX232EEWE+T — сравнение, рекомендации по проектированию и информация о соответствии.
Руководство по выбору
Сравнение с аналогами
| Параметр | Этот товар | MAX232ECWE+ | MAX232EWE+ | MAX232AEWE+ | MAX232ACWE+ | MAX232ECDWR |
|---|---|---|---|---|---|---|
| Package | 16-SOIC (wide SO, 7.50 mm width) | 16-SOIC (wide SO, 7.50 mm width) | 16-SOIC (wide SO, 7.50 mm width) | 16-SOIC (wide SO, 7.50 mm width) | 16-SOIC (wide SO, 7.50 mm width) | 16-SOIC (wide SO, 7.50 mm width) |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Transceiver Configuration | 2 drivers and 2 receivers | 2 drivers and 2 receivers | 2 drivers and 2 receivers | 2 drivers and 2 receivers | 2 drivers and 2 receivers | 2 drivers and 2 receivers |
| Supply Voltage | 5 V | 5 V | 5 V | 5 V | 5 V | 5 V |
| Maximum Data Rate | 120 kbps | 120 kbps | 120 kbps | 120 kbps | 120 kbps | 120 kbps |
| Voltage Generation | Integrated charge-pump circuitry | Integrated charge-pump circuitry | Integrated charge-pump circuitry | Integrated charge-pump circuitry | Integrated charge-pump circuitry | Integrated charge-pump circuitry |
Ключевые отличия
- Full 2/2 RS-232 channel integration (против MAX232ECWE+)
- Single +5V supply with integrated charge pump (против MAX232AEWE+)
- Wide 16-SOIC footprint reuse (против MAX232ACWE+)
Заметки по проектированию
Place the charge-pump capacitors and any decoupling capacitors directly beside their designated MAX232EEWE+T pins, following the layout and component values shown in the manufacturer datasheet. Keep the charge-pump traces short and away from sensitive receiver inputs. Because the device generates bipolar RS-232 voltages internally, long capacitor routes can increase radiated noise and reduce margin in low-noise or long-cable installations.
Do not treat every MAX232-family ordering code as electrically identical. Confirm the supply range, operating temperature, ESD rating, receiver thresholds, and package width before approving a substitute. A wide 16-SOIC footprint does not by itself establish pin compatibility, and the MAX3232 family adds fail-safe behavior that may alter system-level behavior even when the board outline can be reused.
Keep the logic-side UART traces away from the RS-232 driver outputs and charge-pump region to minimize coupling into the receiver path. Provide a low-impedance ground reference beneath the interface, use a suitable return path for the cable, and place any additional connector protection ahead of the transceiver. These steps are important because the MAX232EEWE+T supports 120kbps operation and ±15kV HBM ESD protection, but package-level ESD ratings do not replace correct system grounding.
Use a supply that meets the selected MAX232E variant's voltage and current limits, and verify startup behavior at the system's minimum rail condition. The MAX232EEWE+T generates bipolar driver levels from one 5V rail through its charge pump, which simplifies the power tree but does not remove the need for local bypassing. Check the manufacturer's capacitor recommendations and monitor supply droop when multiple driver channels switch simultaneously.
Информация о соответствии
The MAX232E is a conventional RS-232 interface IC rather than an automotive-qualified device. Explicit RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations were not identified in the referenced listings.