MAX232MWE/PR - Dual RS-232 Transceiver | Analog Devices
MPN: MAX232MWE/PR ✓ AktifMAX232MWE/PR Genel Bakış
An RS-232 transceiver is an interface IC within the broader line-driver and line-receiver category. Its transmitter side adds the voltage swing and biasing required for RS-232 communication, while its receiver side detects the bipolar voltage levels presented on the cable. A complete dual transceiver is therefore useful where two serial data paths must be supported without using separate single-channel driver and receiver devices.
The MAX232MWE/PR provides two full RS-232 channels, operating from a 5 V supply and intended for multipoint or point-to-point RS-232 links. Its military-grade temperature designation makes it relevant to equipment that must tolerate extended environmental conditions. The 16-pin SOIC package supports conventional surface-mount PCB assembly, while its terminal finish is matte tin with an annealed finish and an e3 terminal classification.
Its interface architecture provides the required charge-pump and level-shifting functions for bidirectional RS-232 communication. The two transmitters are intended to drive external RS-232 lines, and the two receivers recover data from those lines for the host UART. Engineers should account for external line protection, connector pin assignment, and the power-supply bypass capacitors specified by the manufacturer datasheet when implementing the interface.
Typical applications include industrial serial controllers, legacy data-acquisition equipment, embedded service ports, telecom equipment, and RS-232 links between a microcontroller or host UART and an external connector. The same electrical interface can support control, monitoring, configuration, and diagnostic channels when the system already uses RS-232 and does not require a modern differential bus such as RS-485 or LVDS.
The main design tradeoff is that this device preserves compatibility with established RS-232 equipment rather than offering the longer reach, common-mode tolerance, and multi-drop capability associated with differential interfaces. Keep the MAX232 supply and ground connections compact, route the cable-side receive nodes away from fast digital signals, and place protection components where the external cable enters the assembly.
This page organizes the MAX232MWE/PR interface specifications, package characteristics, verified drop-in alternatives, comparison parameters, and practical PCB guidance. It also identifies commercial information through the page quotation workflow so engineers can evaluate availability without relying on static market pricing.
Drop-in alternatifler için MAX232MWE/PR — aynı paket, pin-başına uyumlu. PCB yeniden montajı gerektiren farklı paket bileşenleri dışlanmıştır.
Bu Serideki Variantlar
Yedek parça uyumlu olan aynı serideki modeller MAX232MWE/PR (aynı form faktörü ve ayağa oturma) — farklı olan Interface Standard, Product Type, Package, Supply Voltage, Logic Compatibility.
MAX232CWE+
✅ YerleştirmeFiyat için iletişime geçin
Veri Şablonunu Görüntüle →MAX232EWE+T
✅ YerleştirmeFiyat için iletişime geçin
Veri Şablonunu Görüntüle →MAX232ACWE+
✅ Yerleştirme ⚠️ Onaylanmamış ÖzelliklerFiyat için iletişime geçin
Veri Şablonunu Görüntüle →MAX232AEWE+
✅ Yerleştirme ⚠️ Onaylanmamış ÖzelliklerFiyat için iletişime geçin
Veri Şablonunu Görüntüle →MAX232MWE/PR+
✅ Yerleştirme📋 Katalogda Olmayan Referans Alternatifi
MAX232MWE/PR Özellikler
| Product Type | Dual RS-232 transceiver |
| Number of Transmitters | 2 |
| Number of Receivers | 2 |
| Interface Standard | RS-232 |
| Besleme Gerilimi | 5 V |
| Supply Voltage Range | 4.5 V to 5.5 V |
| Paket | 16-pin SOIC |
| Terminal Count | 16 |
| Terminal Form | Gull wing |
| Temperature Grade | Military |
| Terminal Finish | Matte tin (Sn), annealed |
| JESD-609 Code | e3 |
| Moisture Sensitivity Level | MSL 1 |
| Peak Reflow Temperature | 260 C |
| Maximum Time at Peak Reflow | 30 s |
| Montaj Stili | Surface mount |
MAX232MWE/PR 16-pin soic Pin Yapısı Kılavuzu
MAX232MWE/PR (16-pin soic paket) için pin yapısı. Pin numaralandırma, işlevleri ve bağlantı şemaları üretici veri kitapçığında tanımlanmıştır. Doğru ayak ve soldurma kılavuzları için onu referans alın.
Ayrıntılı pin çıkış verisi mevcut değil: MAX232MWE/PR.
Aşağıdaki veri sayfası tam pin konfigürasyonu için.
Tipik Uygulamalar
MAX232MWE/PR için uygundur 6 uygulamas: Industrial Serial Controller, Data-Acquisition Equipment, Embedded Diagnostic Port, Telecom Equipment Interface, Legacy Peripheral Adapter, Aerospace Support Electronics.
Industrial Serial Controller
The MAX232MWE/PR fits an industrial controller that must retain compatibility with RS-232 service equipment. Its two transmitters and two receivers provide two bidirectional RS-232 paths from a 5 V logic system, while the military temperature designation supports designs with wider environmental requirements. The device is used between the host UART and the external DB9 or equivalent connector, with the logic-side and cable-side nets kept separate by the manufacturer pinout. Because RS-232 is a single-ended, unbalanced interface, cable protection and grounding deserve attention in long or electrically noisy installations.
Önerilen
Data-Acquisition Equipment
The MAX232MWE/PR is appropriate for legacy data-acquisition systems that transfer commands and measurements over RS-232. Two complete transceiver channels can support a primary data channel and a separate status or control channel from the same 4.5 V to 5.5 V supply domain. It is placed between the acquisition controller and the external serial connector, where its integrated transmitters and receivers replace separate line-driver and receiver packages. The main design consideration is to follow the specified charge-pump capacitor connections and place connector-side protection close to the cable entry.
Önerilen
Embedded Diagnostic Port
A MAX232MWE/PR-based diagnostic port allows an embedded controller to communicate with service equipment, test fixtures, or a configuration terminal using established RS-232 equipment. The 16-SOIC package is convenient for compact industrial and aerospace-support electronics, while its two transmitters and two receivers permit bidirectional command traffic. Connect the UART logic signals to the receiver inputs and driver outputs as specified, then keep the RS-232 connector nets away from clocks and switching nodes. External protection should be selected for the cable voltage and grounding environment.
Önerilen
Telecom Equipment Interface
The MAX232MWE/PR can provide legacy RS-232 connectivity in telecom equipment that must interoperate with established test or network-management systems. Its dual-channel architecture reduces the component count compared with separate single-direction interface devices, and the 5 V supply operation fits systems that already include that rail. The military-grade designation is relevant where the equipment specifies elevated environmental requirements. Designers should still treat RS-232 as a point-to-point interface and use the manufacturer application circuit for supply bypass and charge-pump components.
Önerilen
Legacy Peripheral Adapter
The MAX232MWE/PR is useful in an adapter that lets a modern controller communicate with a legacy RS-232 printer, instrument, or service device. The adapter can present a conventional UART connector to the host and route the cable-side signals through one of the two transmitter and receiver pairs. Its 16-pin SOIC package permits placement close to the connector, which helps reduce susceptibility to radiated noise and ESD. Select the appropriate external protection network and maintain the interface ground arrangement recommended for the connected equipment.
Önerilen
Aerospace Support Electronics
The MAX232MWE/PR is appropriate for aerospace-support electronics where a 5 V controller must communicate with RS-232 test equipment and the equipment specification calls for the military-grade MAX232MWE configuration. The dual transceiver provides two directional interface channels without requiring separate driver and receiver ICs for each direction. The 16-SOIC package supports controlled surface-mount assembly, although the complete assembly process still determines the final thermal and workmanship assumptions. Confirm the exact ordering code, qualification requirements, and external line protection before production release.
Önerilen
Önerilen Ürünler Özeti
Mühendislik referans verileri: MAX232MWE/PR — karşılaştırma, tasarım rehberi ve uyumluluk bilgileri.
Seçim Kılavuzu
Alternatiflerle Karşılaştırma
| Parametre | Bu Ürün | MAX232CWE+ | MAX232EWE+T | MAX232ACWE+ | MAX232AEWE+ | MAX232MWE/PR+ |
|---|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | 16-SOIC | 16-SOIC | 16-SOIC | 16-SOIC | 16-SOIC | 16-SOIC |
| Interface | RS-232 | RS-232 | RS-232 | RS-232 | RS-232 | RS-232 |
| Number of Transmitters | 2 | 2 | 2 | 2 | 2 | 2 |
| Number of Receivers | 2 | 2 | 2 | 2 | 2 | 2 |
| Nominal Supply Voltage | 5 V | 5 V | 5 V | 5 V | 5 V | 5 V |
Ana Farklılayıcılar
- Military-grade ordering configuration (karşılaştırma:MAX232CWE+)
- Two complete bidirectional RS-232 channels (karşılaştırma:MAX232EWE+T)
- Exact same-family footprint reuse (karşılaştırma:MAX232MWE/PR+)
Tasarım Notları
Place the MAX232MWE/PR close to the RS-232 connector so the cable-side driver and receiver nets remain short. Keep the logic-side UART traces away from these nets, use a continuous ground reference, and avoid routing the interface through areas dominated by switching nodes. Place connector protection at the boundary of the PCB so surge or electrostatic discharge current is diverted before reaching the transceiver.
Use the manufacturer-recommended charge-pump capacitors and supply-bypass arrangement without changing their values or increasing their distance from the associated pins. The MAX232MWE/PR operates from 4.5 V to 5.5 V, so verify the supply range across tolerance, startup, and load transients. A stable 5 V rail is essential because the charge-pump and receiver thresholds support the bipolar RS-232 signaling scheme.
Do not interchange the logic-side UART pins with the cable-side RS-232 pins. Driver outputs connect to the external RS-232 line, while receiver inputs accept the external line; reversing them can prevent communication or expose the interface to incorrect signal levels. Also verify the exact temperature grade and package suffix during inspection, because MAX232 family members share a similar 16-pin interface but may use different environmental qualifications.
Treat the cable-side receiver nodes as sensitive, high-impedance nets and keep them away from clocks, relays, power inductors, and fast digital edges. Use the shortest practical route from the connector to the receiver pins and provide a direct chassis or signal-ground strategy appropriate to the connected equipment. External protection is still required because the PCB transceiver alone does not provide a complete industrial surge-protection solution.
Uyumluluk Bilgisi
The listed terminal finish is annealed matte tin with JESD-609 code e3. RoHS compliance is indicated by the product ordering information, while REACH, halogen-free, and conflict-minerals status are not established by the cited product information.