An RS-232 transceiver is an interface IC that combines line drivers and line receivers on one die. The ADM213EARUZ is designed for EIA-232-E and V.28 links where a +12 V supply is unavailable. Its four-driver and five-receiver arrangement supports multi-channel equipment links, while the full-duplex architecture permits command responses and status data to travel concurrently over separate signal pairs.
Key features include operation from a single +5 V supply, a 200 kbps data rate, and integrated charge-pump support using 0.1 µF capacitors. The shutdown and enable controls support power management, and two receiver outputs remain active in shutdown mode for monitoring selected lines. The 28-pin TSSOP package also provides a compact surface-mount footprint for industrial control, instrumentation, and embedded serial-port equipment.
Technically, the ADM213EARUZ belongs to Analog Devices' ADM2xx family of robust RS-232 and V.28 interface devices. The manufacturer states that the family is intended for electrical environments where 12 V is unavailable and notes compliance with the EU EMC directive identified as 89/336/EEC. Its integrated drivers and receivers reduce the number of external components required for a multi-channel interface while centralizing polarity and signal-level conversion.
Typical uses include industrial control panels, test and measurement instruments, barcode and serial equipment, embedded controllers, and data-acquisition systems. A four-driver link can control four downstream channels, while five receivers can monitor remote equipment status, fault lines, and command acknowledgements. The 200 kbps rate is appropriate for legacy serial-console, point-to-point, and industrial instrumentation links that do not require modern high-speed differential buses.
Place the required charge-pump capacitors close to their associated device pins and maintain symmetric signal routing where possible. Confirm logic-level compatibility, connector pin assignment, and cable length before deployment, because the +5 V interface describes the transceiver supply rather than the RS-232 driver voltage amplitude. The shutdown function should not be used as a substitute for galvanic isolation or surge protection.
This page combines the manufacturer's functional description with practical interface-selection guidance, verified source links, a pin-compatible tape-and-reel option, and engineering notes covering power, layout, and signal integrity.
直接替換替代品,適用於 ADM213EARUZ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: ADM213EARUZ (相同外形與佔位) — 差異在於 Package.
ADM213EARUZ-REEL7
✅ 直接替換📋 參考替代品(不在目錄中)
ADM213EARUZ 規格
| Product Type | RS-232 transceiver |
| 供應電壓 | +5 V |
| 資料速率 | 200 kbps |
| Driver Count | 4 drivers |
| Receiver Count | 5 receivers |
| Duplex Mode | Full duplex |
| Charge-Pump Capacitor | 0.1 µF |
| 封裝 | 28-pin TSSOP |
| 安裝類型 | Surface mount |
| Shutdown Control | Yes |
| Enable Control | Yes |
| Receivers Active in Shutdown | 2 receivers |
| Communication Standard | EIA-232-E and V.28 |
| EMC Directive | EU EMC directive 89/336/EEC |
| RoHS 狀態 | RoHS3 compliant |
| REACH Status | REACH unaffected |
| Moisture Sensitivity Level | MSL 1 (unlimited) |
ADM213EARUZ 28-pin tssop 腳位配置指南
ADM213EARUZ(28-pin tssop 封裝)的腳位配置。 腳位編號、功能與連接圖定義於製造商資料手冊中。請參閱該手冊以取得確切的封裝尺寸與焊接指引。
無詳細腳位定義資料: ADM213EARUZ.
請參閱 資料表 以查看完整腳位配置。
典型應用
ADM213EARUZ 適用於 6 應用s: Industrial Control Panel Interface, Test and Measurement Instrument, Point-to-Point Serial Console, Data Acquisition Equipment, Embedded Equipment Controller, Serial Equipment Networking.
Industrial Control Panel Interface
The ADM213EARUZ suits an industrial control panel that must communicate with several remote actuators while monitoring additional feedback or fault signals. Its four drivers can support four command or control channels, while five receivers provide separate inputs for acknowledgements, interlocks, and status reporting. The full-duplex configuration lets the controller transmit and receive concurrently over independent pairs. Operating from a single +5 V supply simplifies the controller power architecture, while the 200 kbps rate is appropriate for conventional RS-232 equipment links. Designers should still include connector-level surge protection and verify the panel's ground strategy before connecting long external cables.
推薦
Test and Measurement Instrument
The ADM213EARUZ can simplify a laboratory instrument that must issue commands and retrieve data through multiple RS-232 ports. Four driver channels support separate control destinations, while the fifth receiver provides an additional monitoring path beyond the four-command architecture. At a 200 kbps data rate, the interface is well matched to legacy serial-port instruments and bench controllers that exchange moderate volumes of configuration or measurement data. Place the charge-pump capacitors close to the device and keep the ground reference consistent across the instrument, connector, and attached equipment. External protection remains appropriate when users connect the instrument to unknown or externally powered systems.
推薦
Point-to-Point Serial Console
The ADM213EARUZ can be used for an embedded controller or service-console interface that includes receive-monitor lines in addition to its main command path. Although a simple console may need only one transmitter and one receiver, the ADM213EARUZ consolidates four drivers, five receivers, shutdown control, and enable control into one +5 V IC. The two receivers that remain active during shutdown allow a system to monitor selected remote conditions while reducing power to the rest of the interface. The 200 kbps operating rate supports conventional console traffic, but the board design must preserve the manufacturer's pin assignments and charge-pump capacitor placement.
推薦
Data Acquisition Equipment
The ADM213EARUZ fits data-acquisition equipment that exchanges commands and status information with several external sensors or instrument modules. The four-driver arrangement supports multiple outbound control paths, and the five-receiver arrangement permits more incoming measurements than a basic two-wire console interface. Full-duplex operation avoids forcing traffic onto a shared serial direction, while the 200 kbps rate is appropriate for supervisory and status traffic rather than continuous high-volume streaming. In a laboratory or factory installation, use the transceiver with a defined signal-ground reference and add external protection at exposed connectors so transient energy does not bypass the device's intended operating environment.
推薦
Embedded Equipment Controller
The ADM213EARUZ is useful in embedded equipment that retains legacy RS-232 ports while adding controlled power management. Its +5 V operation fits many controller boards, and the shutdown and enable inputs allow the interface to be managed during different system states. Two receivers can continue monitoring important lines while the main transceiver functions are shut down, supporting fault detection or an always-present status indication. This behavior can reduce system power without abandoning communication monitoring. Firmware and hardware should define the enable and shutdown states carefully so partially powered interfaces cannot contend with an external RS-232 driver on the same bus.
推薦
Serial Equipment Networking
The ADM213EARUZ can bridge a controller to a group of legacy RS-232 devices through dedicated driver and receiver channels. Four command outputs can reach separate instruments, and the additional receiver channels can collect independent acknowledgements or interlocks without forcing shared multiplexing. The 200 kbps rate accommodates supervisory commands, status updates, and configuration transfers typical of industrial networks. Because RS-232 is point-to-point rather than a multi-drop bus, keep each driver connected to its intended receiver and avoid connecting multiple outputs together. Maintain consistent reference grounding and include connector protection when equipment is connected or disconnected during field service.
推薦
推薦產品摘要
工程參考資料,適用於 ADM213EARUZ — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | ADM213EARUZ-REEL7 |
|---|---|---|
| Package | 28-pin TSSOP | 28-pin TSSOP |
| Brand | Analog Devices | Analog Devices |
| Product Type | RS-232 transceiver | RS-232 transceiver |
| Supply Voltage | +5 V | +5 V |
| Data Rate | 200 kbps | 200 kbps class device |
| Driver Count | 4 drivers | 4 drivers |
| Receiver Count | 5 receivers | 5 receivers |
| Duplex Mode | Full duplex | Full duplex |
| Shutdown and Enable | Shutdown and enable pins | Shutdown and enable pins |
| Charge-Pump Capacitor | 0.1 µF | 0.1 µF |
主要差異化特點
- Integrates four drivers and five receivers in one interface IC (對比MAX3221EIDBR)
- Supports monitoring while the main interface is shut down (對比ADM213EARUZ-REEL7)
- Uses a single +5 V supply for RS-232 interface operation (對比MAX3221EIDBR)
設計說明
Place the manufacturer's specified 0.1 µF charge-pump capacitors directly beside the corresponding ADM213EARUZ pins, with short, low-loop-area traces and a common ground return. Keep the RS-232 driver and receiver routes away from clocks, switching supplies, and high-slew-rate digital nets. The internal charge pump produces bipolar RS-232 voltage from +5 V, so bypassing and layout quality directly affect both output integrity and electromagnetic emissions.
Treat RS-232 as a point-to-point interface and route each driver output to the intended receiver input. Do not connect multiple driver outputs together, even when several channels appear unused. For long or noisy cables, use a consistent signal-ground reference, route the cable ground alongside the data conductors, and place external transient protection at the connector. The ADM213EARUZ's 200 kbps class operation does not remove the need for cable and grounding engineering.
Decouple the +5 V supply locally and ensure it can support both the logic load and the charge-pump current without excessive ripple. Use the Analog Devices recommended capacitor values and placement rather than adding arbitrary bulk capacitance that may destabilize the charge-pump node. Coordinate the enable and shutdown states in firmware so the active transmitters cannot be connected to another powered driver on the same RS-232 pair.
合規資訊
The component record identifies RoHS3 compliance, REACH unaffected status, and lead-free ordering. Analog Devices states that the ADM213E family complies with the EU EMC directive identified as 89/336/EEC.