ADS1213E/1K - 22-Bit 4-Channel Delta-Sigma ADC | Texas Instruments
MPN: ADS1213E/1K ✓ 啟用中ADS1213E/1K 概覽
A delta-sigma ADC is a type of analog-to-digital converter that uses a high-resolution internal modulator and digital filtering to convert continuous analog voltages into digital codes. The ADS1213 belongs to the ADC, data-converter IC, and signal-processing semiconductor hierarchies. It is intended for precision measurement systems requiring high resolution, integrated channel multiplexing, and flexible gain control.
Key features include 22-bit nominal resolution, four analog input channels, conversion throughput up to 6.25 kSPS, and a programmable gain amplifier. The device supports internal and external voltage references, which permits either an on-chip reference implementation or a more precise external source. Its serial interface reduces the number of external connections required in multi-channel measurement equipment.
Technically, the converter combines delta-sigma conversion, digital filtering, channel multiplexing, and programmable gain in one integrated circuit. The four-input architecture makes it suitable for bridge, sensor, voltage, and current measurements that require multiple analog channels. Because it is a single-supply device, the converter simplifies system-level power planning when the measured signals remain within the supported analog input range.
Typical applications include industrial pressure and temperature measurement, strain-gauge and bridge excitation systems, laboratory instrumentation, process monitoring, and precision data-acquisition modules. The integrated programmable gain amplifier can reduce the need for external analog conditioning when the source signal lies within a selectable gain range.
A critical layout consideration is that reference, supply, and analog-input traces should be routed away from high-current digital switching paths. Place input and reference capacitors close to their associated pins, use a quiet ground return, and maintain consistent grounding between the converter and the sensor interface. Confirm the absolute and differential input limits before applying bipolar signals.
This page combines manufacturer specifications, package details, engineering guidance, application fit, and verified drop-in information to support component selection and PCB implementation without reproducing the complete manufacturer datasheet.
直接替換替代品,適用於 ADS1213E/1K — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: ADS1213E/1K (相同外形與佔位) — 差異在於 Architecture, Programmable Gain Amplifier, RoHS Status, Supply Voltage.
ADS1213E/1KG4
✅ 直接替換📋 參考替代品(不在目錄中)
ADS1213E/1K 最大額定值與電氣特性
| ADC Resolution | 22 bit |
| Conversion Rate | 6.25 kSPS |
| Analog Input Channels | 4 channels |
| Device Channel Configuration | 8-channel device |
| Architecture | Delta-sigma |
| 供應電壓 | 5 V |
| Reference Type | Internal or external |
| Programmable Gain Amplifier | Integrated PGA |
| 介面類型 | Serial |
| 封裝 | 28-pin SSOP (DB) |
| Terminal Form | Gull wing |
| Package Shape | Rectangular |
| 安裝方式 | Surface mount |
| 工作溫度 | -40°C to +85°C |
| Temperature Grade | Industrial |
| Packaging | Tape and reel |
| RoHS 狀態 | Compliant |
| Lead-Free Status | Lead-free |
ADS1213E/1K rectangular 腳位配置指南
ADS1213E/1K(rectangular 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: ADS1213E/1K.
請參閱 資料表 以查看完整腳位配置。
典型應用
ADS1213E/1K 適用於 6 應用s: Industrial Pressure Transmitters, Strain-Gauge and Bridge Measurements, Precision Temperature Acquisition, Process-Control Instrumentation, Laboratory and Test Equipment, Data-Acquisition Modules.
Industrial Pressure Transmitters
ADS1213E/1K fits pressure-transmitter front ends that must digitize several low-level sensor signals accurately. Its 22-bit nominal resolution provides a high-resolution conversion stage, while the four-channel input multiplexer supports shared reference and diagnostic measurements. The 6.25-kSPS maximum rate is appropriate for many industrial pressure systems that favor filtering and stable readings over very high-speed sampling. The integrated PGA can reduce frontend gain requirements, although the selected gain must remain compatible with the bridge or transducer output common-mode range. A single 5 V supply also simplifies transducer-interface power planning. For reliable deployment, protect the inputs from industrial surges, route the sensor returns cleanly, and verify the converter’s settling behavior for the selected digital filter.
推薦
Strain-Gauge and Bridge Measurements
The ADS1213E/1K is well suited to strain-gauge and resistive-bridge instrumentation because it combines four analog inputs, programmable gain, and 22-bit nominal delta-sigma resolution. At up to 6.25 kSPS, it can acquire force, load, or displacement signals while applying the appropriate internal gain. The programmable gain amplifier helps match the converter input range to a small differential bridge output, but common-mode voltage and allowable gain must be checked carefully because both determine usable signal headroom. Supply excitation and analog grounds should be arranged so switching currents do not appear in the bridge return path. Place reference and input bypass components near the device, and use a stable excitation source when system accuracy must be dominated by the mechanical sensor rather than the ADC.
推薦
Precision Temperature Acquisition
ADS1213E/1K can serve precision temperature-measurement systems using RTDs, thermocouple conditioning, or resistive sensors. Its 22-bit nominal resolution is valuable when the final temperature resolution is limited by sensor accuracy rather than conversion speed, and the 6.25-kSPS rate is more than sufficient for many thermal-loop and laboratory channels. Four inputs allow measurement of active sensors alongside reference or diagnostic channels. The internal or external reference choice lets the design balance simplicity against stability, with an external reference potentially improving tracking performance when supported by the sensor and excitation architecture. Keep thermocouple and RTD wiring away from power converters and motor nodes, use appropriate input filtering, and validate the complete sensor-to-digital path for offset, drift, and settling.
推薦
Process-Control Instrumentation
ADS1213E/1K supports process-control modules that monitor several slow or medium-speed analog variables from sensors, transmitters, or laboratory fixtures. The 6.25-kSPS conversion rate accommodates many closed-loop measurement loops, while the four-channel multiplexer reduces the number of separate converter packages needed. Its integrated PGA and selectable reference architecture help standardize input conditioning across channels. For a process panel, filtering and selectable data rates can suppress 50/60-Hz-related interference when the required settling time permits, but the digital-filter configuration must be checked against update timing. Keep analog routing compact, provide a clean reference return, isolate motor and relay loads from the converter ground, and perform channel-by-channel calibration to account for gain, offset, and sensor variation.
推薦
Laboratory and Test Equipment
ADS1213E/1K is appropriate for laboratory instruments that digitize low-level analog measurements and need high nominal resolution rather than maximum sampling frequency. The four analog inputs can support multiplexed transducer channels, and the programmable gain amplifier allows a single converter to handle signals occupying different amplitude ranges. The 5 V analog supply and 6.25-kSPS maximum throughput simplify synchronization with embedded control hardware. In an instrument, the converter’s internal digital filter can reject noise outside the usable bandwidth, so selecting a slower data rate may improve measurement stability without requiring analog changes. Shield sensitive inputs, use a dedicated analog ground region, separate digital return currents from reference returns, and verify calibration behavior over temperature if measurement accuracy is critical.
推薦
Data-Acquisition Modules
ADS1213E/1K can form the measurement core of compact data-acquisition modules requiring several channels and consistent high-resolution conversion. Its multiplexed four-input architecture, programmable gain amplifier, and internal or external reference support different sensor types behind a common acquisition interface. At 6.25-kSPS, the converter is appropriate for environmental, vibration-envelope, laboratory, and industrial monitoring channels that do not require megahertz-class sampling. A practical design should preserve the selected reference and analog-input impedance by keeping traces short and placing bypass capacitors at the device. Include calibration words or system-level offset and gain correction where precision matters, and avoid sharing high-current return paths between the reference and sensor circuitry.
推薦
推薦產品摘要
工程參考資料,適用於 ADS1213E/1K — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | ADS1213E/1KG4 |
|---|---|---|
| Package | SSOP-28 (DB) | SSOP-28 (DB) |
| Brand | Texas Instruments | Texas Instruments |
| ADC Resolution | 22 bit | 22 bit |
| Conversion Rate | 6.25 kSPS | 6.25 kSPS |
| Analog Input Channels | 4 channels | 4 channels |
| Supply Voltage | 5 V | 5 V |
| Reference Type | Internal or external | Internal or external |
| Programmable Gain Amplifier | Integrated PGA | Integrated PGA |
主要差異化特點
- Closest verified ordering alternative retains identical conversion specifications (對比ADS1213E/1KG4)
- Combines multichannel conversion and programmable gain in one device (對比ADS1213E/1KG4)
- Supports precision conversion at a moderate 6.25-kSPS ceiling (對比ADS1213E/1KG4)
設計說明
Place the reference bypass capacitor and analog-input bypass components directly beside their associated ADS1213E/1K pins. Keep the analog-input traces short and route them away from the serial clock, data lines, inductors, and switching-regulator nodes. The exposed-pad or thermal arrangement and exact decoupling values should follow the manufacturer’s layout guidance. A quiet reference return is particularly important because reference and input ground currents can create conversion error if they share a noisy digital path.
Choose the serial-interface rate and data-filter settings as one system-level decision. The converter can reach 6.25 kSPS, but a lower data rate can reduce noise and improve settling for slow sensors. Check the required conversion sequence against the serial clock timing and microcontroller receive capability. For long traces between the ADC and controller, use a controlled-length interface, a ground reference beside the signal path, and series damping only if timing and edge-rate analysis support it.
Do not select PGA gain or excitation voltage without checking the absolute input and common-mode limits. Bridge outputs can exceed the converter’s permitted common-mode range even when their differential magnitude is small. Likewise, a sensor output that is valid for a 3.3 V system may exceed the ADS1213E/1K limits if paired with a 5 V excitation. Review the pin table, input-protection limits, operating temperature, and gain settings in the manufacturer datasheet before finalizing the analog front end.
合規資訊
The exact ADS1213E/1K listing identifies the component as RoHS-compliant, lead-free, and green. No automotive qualification or REACH statement was established for this ordering code.