INA4180AIPWR - 26V Quad Current-Sense Amplifier 350kHz | TI
MPN: INA4180AIPWR ✓ 啟用中INA4180AIPWR 概覽
A current-sense amplifier is an analog IC that amplifies the small differential voltage across a sense resistor and translates it to a ground-referenced output. In the power-management hierarchy it sits between the power path and the monitoring stage, providing feedback for overcurrent protection, closed-loop current control, and load telemetry. The INA4180 integrates four such amplifiers in one IC, cutting BOM cost and board area versus single-channel INA180 or dual-channel INA2180 devices.
Key features include a 350 kHz bandwidth, a common-mode range of -0.2 V to +26 V, and four rail-to-rail output channels that drive ADCs, comparators, or microcontrollers directly. Gain options of 20, 50, 100, and 200 V/V are available across the family (suffix A1-A4), set by internal matched resistor networks with low gain error and good temperature stability. AEC-Q100 qualified Q1 variants such as INA4180A2QPWRQ1 serve automotive designs.
Because the common-mode range is independent of the supply, the amplifier can monitor high-side shunts on a 24 V rail while operating from a 3.3 V or 5 V supply, eliminating level-shifting circuitry. The architecture uses a precision differential front end with internal gain-setting resistors, so no external precision resistors are required.
Typical applications include industrial motor control, DC-DC converter output current monitoring, battery charging systems, telecom board power monitoring, LED lighting load sensing, and automotive load detection.
Design tip: use precision Kelvin connections to the shunt, place input filter resistors close to the IC, and never exceed the 26 V common-mode limit without transient protection. As of 2026-08-30, pricing data should be confirmed with distributors.
直接替換替代品,適用於 INA4180AIPWR — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: INA4180AIPWR (相同外形與佔位) — 差異在於 Output Type.
INA4180A1IPWR
✅ 直接替換📋 參考替代品(不在目錄中)
INA4180A2IPWR
✅ 直接替換📋 參考替代品(不在目錄中)
INA4180A4IPWR
✅ 直接替換📋 參考替代品(不在目錄中)
INA4180AIPWR-Q1
✅ 直接替換聯絡詢價
查看資料表 →INA4180AIPWR 最大額定值與電氣特性
| 通道數 | 4 |
| Amplifier Type | Current sense amplifier (current-shunt monitor) |
| Common-Mode Voltage Range | -0.2 V to +26 V |
| Common-Mode Independence | Independent of supply voltage |
| Bandwidth | 350 kHz |
| Gain Options (family) | 20, 50, 100, 200 V/V (A1, A2, A3, A4 suffixes) |
| 輸出類型 | Rail-to-rail voltage output |
| Accuracy Class | Cost-optimized (base accuracy version) |
| 封裝 | 14-TSSOP (PW) |
| 安裝類型 | Surface Mount |
| Applications | Low-side and high-side current sensing |
| Automotive Qualification | Q1 variants available (e.g., INA4180A2QPWRQ1, AEC-Q100) |
| RoHS 狀態 | Compliant |
INA4180AIPWR 腳位配置
| 腳位 1 | IN+1 — Channel 1 non-inverting input (to shunt high side) |
| 腳位 2 | IN-1 — Channel 1 inverting input (to shunt low side) |
| 腳位 3 | GND — Ground reference |
| 腳位 4 | IN+2 — Channel 2 non-inverting input |
| 腳位 5 | IN-2 — Channel 2 inverting input |
| 腳位 6 | OUT1 — Channel 1 rail-to-rail voltage output |
| 腳位 7 | OUT2 — Channel 2 voltage output |
| 腳位 8 | VREF1 — [DATA_NEEDED: pin 8 function per datasheet] |
| 腳位 9 | [DATA_NEEDED: pin 9] — [DATA_NEEDED: pin 9 description] |
| 腳位 10 | [DATA_NEEDED: pin 10] — [DATA_NEEDED: pin 10 description] |
| 腳位 11 | [DATA_NEEDED: pin 11] — [DATA_NEEDED: pin 11 description] |
| 腳位 12 | [DATA_NEEDED: pin 12] — [DATA_NEEDED: pin 12 description] |
| 腳位 13 | [DATA_NEEDED: pin 13] — [DATA_NEEDED: pin 13 description] |
| 腳位 14 | VS — Power supply |
典型應用
INA4180AIPWR 適用於 6 應用s: Industrial Motor Control, DC-DC Converter Output Monitoring, Battery Charging Systems, Telecom Board Power Monitoring, LED Lighting Load Sensing, Automotive Load Detection.
Industrial Motor Control
The INA4180AIPWR monitors phase and bus currents in industrial motor drives, where its 350 kHz bandwidth captures fast current transients and its -0.2 V to +26 V common-mode range covers 24 V bus rails independent of the controller supply. Each of the four channels can watch a different motor or rail, replacing four single-channel INA180 devices. Outputs drive the ADC inputs of MCUs such as the TMS320F28004x C2000 series for closed-loop torque control and overcurrent protection, with rail-to-rail outputs maximizing usable ADC range at 3.3 V.
推薦
DC-DC Converter Output Monitoring
In point-of-load and telecom DC-DC converters, the INA4180AIPWR senses output shunt current for load telemetry and overcurrent flagging. Its common-mode range independent of supply lets one 3.3 V-supplied IC monitor multiple 5 V, 12 V, and 24 V output rails simultaneously via the four channels. The 350 kHz bandwidth is sufficient for average current loops and fault detection in converters like the TPS548B28, while internal matched gain resistors preserve accuracy without external precision parts, reducing BOM cost in cost-optimized power designs.
推薦
Battery Charging Systems
Battery chargers benefit from the INA4180AIPWR's ability to monitor charge current, discharge current, and pack voltage-derived loads across four channels with one device. The -0.2 V common-mode floor supports sensing near ground during deep-discharge conditions, while 26 V covers 12 V and 24 V battery stacks. Rail-to-rail outputs feed charger controller ADCs for coulomb counting and termination decisions. Gain variants (20-200 V/V) let designers optimize shunt power dissipation versus signal amplitude for low-power battery telemetry in charging systems using parts like the BQ24610.
推薦
Telecom Board Power Monitoring
Telecom line cards and baseband boards run on -48 V-derived or 24 V intermediate buses; the INA4180AIPWR provides per-rail current telemetry for power budgeting and hot-swap supervision. One quad device monitors four supply rails, cutting board area versus four single-channel monitors. Its ground-referenced rail-to-rail outputs interface directly with system-monitor MCUs or the INA226-class digital monitors for aggregation. The 350 kHz bandwidth enables detection of short-circuit current spikes faster than software polling, protecting expensive telecom silicon from sustained overloads.
推薦
LED Lighting Load Sensing
In high-brightness and smart LED drivers, the INA4180AIPWR senses LED string current for closed-loop regulation and fault detection (open/short string). Four channels allow multi-string luminaires to be monitored by a single IC. The 350 kHz bandwidth supports fast overcurrent response complementary to drivers like the LM3444 or TPS92691, while the 26 V common-mode rating covers typical LED supply rails. Rail-to-rail output near ground supports accurate dimming-level feedback into PWM controllers operating from 3.3 V or 5 V logic supplies.
推薦
Automotive Load Detection
AEC-Q100 qualified INA4180-Q1 variants bring the same quad-channel 26 V architecture into automotive 12 V battery-rail load detection: body control modules, zone controllers, and e-fuse supervision. The common-mode range independent of supply handles load-dump-adjacent transients within the 26 V rating when paired with upstream protection. Each channel monitors a different actuator or rail (lamps, pumps, fans), providing ground-referenced outputs to safety MCUs such as AM2634-Q1. Using one quad device instead of four singles reduces component count in high-channel-count automotive body electronics.
推薦
推薦產品摘要
工程參考資料,適用於 INA4180AIPWR — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | INA4180A1IPWR | INA4180A2IPWR | INA4180AIPWR-Q1 | INA2180A2IDR |
|---|---|---|---|---|---|
| Package | 14-TSSOP (PW) | 14-TSSOP (PW) - same | 14-TSSOP (PW) - same | 14-TSSOP (PW) - same | SOIC-8 - different package |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Channels | 4 | 4 | 4 | 4 | 2 |
| Common-Mode Range | -0.2 V to +26 V | -0.2 V to +26 V | -0.2 V to +26 V | -0.2 V to +26 V | -0.2 V to +26 V |
| Bandwidth | 350 kHz | 350 kHz | 350 kHz | 350 kHz | 350 kHz |
| Fixed Gain | Family gain (A1-A4: 20-200 V/V) | 20 V/V | 50 V/V | Family gain (A1-A4) | 50 V/V |
| Automotive Grade | No | No | No | Yes (AEC-Q100) | No |
主要差異化特點
- Four channels in one 14-TSSOP (對比INA180 (single-channel))
- Common-mode range independent of supply (對比Generic op-amp sense circuits)
- AEC-Q100 upgrade path (對比INA4180AIPWR-Q1)
設計說明
Use Kelvin connections at the shunt: route IN+ and IN- traces directly to the shunt resistor pads, not to shared current-carrying copper. Even milliohms of trace resistance creates gain error. Keep the input RC filter (if used) resistors small and placed close to the IC pins. This follows the typical application layout guidance in the TI INAx180 datasheet Rev. H.
Never exceed the 26 V common-mode limit. Automotive 12 V rails can see load-dump transients above this; add series resistance and clamping upstream. Also remember the common-mode range is independent of supply, but the output cannot exceed VS - verify shunt value and gain (20-200 V/V) so full-scale load current maps within the ADC input range without rail clipping.
The 350 kHz bandwidth passes fast switching edges from nearby MOSFETs. Ground the amplifier close to the shunt low-side node and add a small filter capacitor at the output if the ADC sampling introduces aliasing. For PWM-rejection-critical motor phase sensing, consider INA240 instead, which offers enhanced PWM common-mode rejection.
合規資訊
RoHS compliant per DigiKey listing. AEC-Q100 qualification applies only to Q1 variants (e.g., INA4180A2QPWRQ1). REACH and halogen status [DATA_NEEDED] from TI product page.