MCP3422A5-E/MC - 18-Bit Dual-Input Sigma-Delta ADC | Microchip
MPN: MCP3422A5-E/MC ✓ 啟用中MCP3422A5-E/MC 概覽
An analog-to-digital converter is an integrated circuit that converts an analog input voltage into a numeric value for processing, storage, display, or control. The MCP3422 belongs to the ADC hierarchy and uses a sigma-delta architecture, which is especially useful for low-frequency precision measurements where narrow bandwidth is more important than high-rate waveform capture. Its two analog input channels allow one converter to serve multiple sensors or measurement nodes.
The MCP3422A5-E/MC provides 18-bit resolution, dual analog inputs, and a 3.75 Hz conversion rate. These characteristics suit temperature, pressure, load-cell, chemical-sensor, and slow industrial process measurements where a stable input signal is sampled over time. Its operating supply range of 2.7 V to 5.5 V supports both 3.3 V and 5 V system architectures, while the I2C interface reduces the number of signal connections required on a compact circuit board.
Sigma-delta conversion uses continuous-time modulation and digital filtering to reduce quantization noise near the signal bandwidth. This makes the architecture appropriate for extracting relatively small changes from sensor outputs without requiring a high-speed successive-approximation ADC. The onboard reference supports a self-contained measurement chain, while external analog conditioning remains important for protecting the inputs and scaling signals into the converter’s measurement range.
Typical applications include battery-powered environmental sensors, industrial pressure transmitters, precision temperature instrumentation, laboratory data-acquisition modules, and low-rate weighing systems. The 2 mm by 3 mm DFN package supports compact sensor assemblies, and the dual-input arrangement can reduce component count when two related analog signals must be measured.
PCB design should prioritize a quiet reference return, short analog traces, and placement of input filtering close to the MCP3422A5-E/MC. Because this is a low-rate precision ADC, switching circuitry and high-current digital paths should be kept away from the analog pins to avoid degrading the measured signal.
This product page combines the exact MCP3422A5-E/MC electrical identity, package information, drop-in family alternatives, comparison data, and practical design guidance to support component selection, PCB planning, and sourcing decisions.
直接替換替代品,適用於 MCP3422A5-E/MC — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: MCP3422A5-E/MC (相同外形與佔位) — 差異在於 Package, Digital Interface, Conversion Rate, Differential Input Range, Resolution.
MCP3422A0-E/MC
✅ 直接替換聯絡詢價
查看資料表 →MCP3422A0T-E/MC
✅ 直接替換📋 參考替代品(不在目錄中)
MCP3422A2-E/MC
✅ 直接替換聯絡詢價
查看資料表 →MCP3422A3-E/MC
✅ 直接替換聯絡詢價
查看資料表 →MCP3422A5T-E/MC
✅ 直接替換📋 參考替代品(不在目錄中)
MCP3422A5-E/MC 最大額定值與電氣特性
| ADC Type | Sigma-delta analog-to-digital converter |
| 解析度 | 18 bit |
| Analog Input Channels | 2 inputs |
| Conversion Rate | 3.75 samples/s |
| Supply Voltage Range | 2.7 V to 5.5 V |
| Digital Interface | I2C |
| Internal Reference | Onboard voltage reference |
| 封裝 | 8-DFN, 2 mm x 3 mm |
| 腳位數 | 8 pins |
| 安裝類型 | Surface mount |
| RoHS 狀態 | RoHS |
MCP3422A5-E/MC 8-dfn, 2 mm x 3 mm 腳位配置指南
MCP3422A5-E/MC(8-dfn, 2 mm x 3 mm 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: MCP3422A5-E/MC.
請參閱 資料表 以查看完整腳位配置。
典型應用
MCP3422A5-E/MC 適用於 6 應用s: Precision Temperature Sensing, Industrial Pressure Monitoring, Load Cell and Weighing Systems, Chemical and Environmental Sensors, Battery-Powered Instrumentation, Laboratory Data Acquisition.
Precision Temperature Sensing
The MCP3422A5-E/MC fits low-rate temperature measurement because its 18-bit sigma-delta converter provides high numerical resolution while operating at 3.75 samples/s. Two analog inputs can monitor two temperature channels or one sensor plus a reference channel. The device is commonly placed behind an RTD, thermocouple, or resistive sensor front end, with filtering close to the analog pins. Its onboard reference and I2C interface simplify acquisition, although sensor excitation and input-scaling circuitry remain separate from the ADC.
推薦
Industrial Pressure Monitoring
The MCP3422A5-E/MC is appropriate for slow industrial pressure signals that require more numerical resolution than an 8-bit or 12-bit converter provides. At 3.75 samples/s, the ADC can continuously update a filtered pressure measurement while communicating over I2C to a controller. The dual inputs can serve a pressure sensor and a diagnostic channel. A ratiometric bridge, protection network, and analog filter should be designed to preserve the converter’s effective noise performance.
推薦
Load Cell and Weighing Systems
The 18-bit resolution of the MCP3422A5-E/MC is useful for weighing platforms and load-cell front ends where a small differential voltage represents a relatively small mechanical force. The low 3.75 samples/s conversion rate suits static or slowly changing loads rather than dynamic vibration analysis. An instrumentation-amplifier stage, excitation source, and differential filtering network should precede the ADC, while the I2C interface connects the converter to a display or system controller.
推薦
Chemical and Environmental Sensors
The MCP3422A5-E/MC can digitize slow outputs from electrochemical, gas, conductivity, and environmental sensors without the complexity of a high-rate acquisition system. Its dual inputs permit monitoring a sensing electrode and a reference or auxiliary channel, while 18-bit resolution supports fine-grained numerical measurement. Because these sensors can present high source impedance or millivolt-level signals, the design should use a low-noise amplifier and guarded, filtered routing before conversion.
推薦
Battery-Powered Instrumentation
The MCP3422A5-E/MC supports compact, battery-powered instrumentation because its primary function is low-rate precision acquisition rather than continuous high-speed conversion. The 2.7 V to 5.5 V supply range accommodates common low-voltage rails, and the I2C interface allows measured data to be transferred efficiently to a microcontroller or wireless controller. Duty-cycling the converter and peripheral circuitry can help control average system power when the measured quantity changes slowly.
推薦
Laboratory Data Acquisition
The MCP3422A5-E/MC is useful in laboratory measurement systems that monitor slowly varying voltages and value high-resolution readings over a narrow bandwidth. Two inputs allow simultaneous use for a DUT measurement and a calibration or monitor channel. The 18-bit resolution and onboard reference simplify the measurement chain, while I2C supports connection to embedded controllers. For faster transient capture, designers should select an ADC with a higher conversion rate rather than accelerating this sigma-delta device beyond its intended operating mode.
推薦
推薦產品摘要
工程參考資料,適用於 MCP3422A5-E/MC — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | MCP3422A0-E/MC | MCP3422A0T-E/MC | MCP3422A2-E/MC | MCP3422A3-E/MC | MCP3422A5T-E/MC |
|---|---|---|---|---|---|---|
| Package | 8-DFN (2x3) | 8-DFN (2x3) | 8-DFN (2x3) | 8-DFN (2x3) | 8-DFN (2x3) | 8-DFN (2x3) |
| Brand | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology | Microchip Technology |
| Resolution | 18 bit | 18 bit | 18 bit | 18 bit | 18 bit | 18 bit |
| Converter Architecture | Sigma-delta | Sigma-delta | Sigma-delta | Sigma-delta | Sigma-delta | Sigma-delta |
| Supply Voltage Range | 2.7 V to 5.5 V | 2.7 V to 5.5 V | 2.7 V to 5.5 V | 2.7 V to 5.5 V | 2.7 V to 5.5 V | 2.7 V to 5.5 V |
| Digital Interface | I2C | I2C | I2C | I2C | I2C | I2C |
主要差異化特點
- High numerical resolution in a compact dual-input converter (對比MCP3422A3-E/MC)
- Dual analog inputs reduce measurement-channel component count (對比MCP3422A0-E/MC)
- Compact 8-DFN footprint supports space-constrained sensor assemblies (對比MCP3422A2-E/MC)
- Onboard reference supports a compact measurement architecture (對比MCP3422A5T-E/MC)
設計說明
Place the MCP3422A5-E/MC close to the sensor front end and route both analog inputs as short, matched paths. Keep the exposed pad connection consistent with the manufacturer land-pattern guidance. Separate the analog input region from I2C clock and data routing where practical, and provide a quiet ground return for the converter and reference circuitry to minimize coupling from digital switching activity.
Use the input-network topology and capacitor values specified in the manufacturer datasheet for the selected source impedance. Sensor signals are often small and slow, making leakage, offset, and resistor mismatch more important than wideband timing. Verify the source impedance against the converter’s sampling network before adding large filter capacitors, because excessive capacitance can affect settling and conversion accuracy.
Do not treat the 18-bit resolution as a guarantee of 18 bits of useful accuracy. Overall error also depends on the reference, analog front end, noise, calibration, layout, and operating mode. Confirm the differential or single-ended input configuration, conversion mode, digital filter settling time, and output data format in the manufacturer datasheet before writing firmware or calculating scaling.
Decouple the 2.7 V to 5.5 V supply close to the device and connect the exposed pad as directed by the package drawing. Keep sensor excitation currents and regulator switching loops away from the analog return path. For battery-powered equipment, account for both the converter operating current and the external front end because analog amplifiers, references, and filters may dominate the total system demand.
合規資訊
The verified product listing identifies the MCP3422A5-E/MC as RoHS compliant. No explicit REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declaration was identified for this exact ordering code.