ADS1253EG4 - 24-Bit, 20-kSPS Delta-Sigma ADC | Texas Instruments
料号: ADS1253EG4 ✓ 量产中ADS1253EG4 概述
A delta-sigma ADC is a voltage-to-digital converter category that uses oversampling, noise shaping, and digital filtering to achieve high resolution and excellent low-frequency noise performance. The ADS1253EG4 belongs to the hierarchy of analog-to-digital converters, data-converter ICs, signal-chain semiconductors, and integrated circuits. Differential inputs help reject common-mode noise when a sensor is referenced to a local analog ground or connected through shielded, balanced wiring.
Key features include 24-bit resolution, an output data rate of 20 kSPS, four differential input channels, and a sigma-delta conversion architecture. The device operates from a single 5 V supply and exposes its data through a two-wire serial interface identified in the product information as SPI-compatible. A 20 kSPS maximum rate is appropriate for pressure, temperature, strain, load-cell, flow, and industrial process signals rather than high-bandwidth waveform acquisition.
The four-channel differential architecture supports simultaneous analog monitoring from multiple sensors while reducing the number of external converters required. Because the input stage and digital filter determine signal fidelity, grounding, reference selection, input protection, and clock implementation require careful PCB planning. A stable voltage reference and correctly placed bypass capacitors are particularly important when the converter must preserve its nominal 24-bit resolution.
Typical applications include precision pressure and temperature measurement, load-cell and strain-gauge instrumentation, battery-cell monitoring, laboratory data acquisition, process-control equipment, and portable industrial measurement systems. The 20-kSPS rate is especially suitable for slowly changing physical quantities that do not require high-frequency sampling.
Design the analog input path with short traces, solid ground-plane continuity, and protection networks selected not to distort the intended measurement bandwidth. Use the manufacturer pin-description and recommended-application information when assigning differential inputs, reference terminals, bypass connections, and serial-interface signals. This page consolidates the verified product characteristics, same-package alternatives, and application guidance for faster component selection.
直接替换替代料: ADS1253EG4 ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
本系列中的变体
可与以下型号直接替换的同系列型号: ADS1253EG4 (相同外形与封装尺寸) ——差异在于 Package, Input Configuration, Resolution, Integral Nonlinearity, Number of Input Channels.
ADS1254E
✅ 直接替换✓ 有现货
$11.4844 / 个
查看数据手册 →ADS1240E
✅ 直接替换联系询价
查看数据手册 →ADS1251UG4
✅ 直接替换📋 参考替代料(不在目录中)
ADS1256IDBR
✅ 直接替换联系询价
查看数据手册 →ADS1252E
✅ 直接替换 ⚠️ 规格未核验📋 参考替代料(不在目录中)
ADS1255E
✅ 直接替换 ⚠️ 规格未核验📋 参考替代料(不在目录中)
ADS1253EG4 最大额定值与电气特性
| ADC Resolution | 24 bit |
| Maximum Sampling Rate | 20 kSPS |
| Number of Input Channels | 4 channels |
| Input Configuration | 4 differential inputs |
| Conversion Architecture | 1 sigma-delta architecture |
| Analog Supply Voltage | 5 V |
| Digital Supply Voltage | 5 V |
| Minimum Operating Supply | 4.75 V |
| Supply Configuration | 1 single supply |
| Serial Interface | 2-wire SPI-compatible serial interface |
| 封装 | 16-SSOP |
| Package Type | SSOP |
| Terminal Form | Gull wing |
| Number of Terminals | 16 terminals |
| 安装类型 | Surface mount |
| Temperature Grade | Industrial |
ADS1253EG4 ssop 引脚配置指南
ADS1253EG4(ssop 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: ADS1253EG4.
请参阅 数据手册 以查看完整引脚配置。
典型应用
ADS1253EG4 适用于 6 应用s: Precision Load-Cell Measurement, Industrial Pressure and Flow Sensing, Temperature Measurement and Control, Battery-Cell Monitoring, Laboratory and Portable Instrumentation, Process-Control Data Acquisition.
Precision Load-Cell Measurement
The ADS1253EG4 fits load-cell and strain-gauge instrumentation because its four differential inputs can reject common-mode voltage while measuring low-level bridge signals. The 24-bit nominal resolution supports high-resolution digitization of slow force, weight, and pressure changes, and the 20-kSPS maximum rate is ample for typical mechanical response frequencies. Place the bridge excitation, analog input paths, and reference circuitry near the converter to minimize offsets and noise. Confirm differential range, common-mode limits, and recommended front-end gain using the manufacturer datasheet before finalizing the bridge amplifier network.
推荐
Industrial Pressure and Flow Sensing
The ADS1253EG4 is appropriate for industrial pressure transmitters and slow flow-control loops where sensor outputs are small differential voltages rather than high-frequency waveforms. Its four channels allow a controller to monitor several pressure lines or process variables, while the single 5 V supply simplifies industrial power architecture. The 24-bit nominal resolution supports fine measurement resolution, and the 20-kSPS maximum output rate provides margin beyond typical process-control bandwidth. Use filtering appropriate to the sensor dynamics and protect each input against surge or out-of-range industrial transients.
推荐
Temperature Measurement and Control
The ADS1253EG4 can digitize several low-bandwidth temperature channels from resistive sensors, thermocouple front ends, or ratiometric bridges. Four differential inputs reduce the converter count in multizone thermal systems, while 24-bit nominal resolution preserves fine code resolution when the signal is properly amplified and referenced. The 20-kSPS maximum rate exceeds the needs of most thermal loops, allowing selectable digital filtering to suppress noise. A stable reference is critical because offset and reference drift can dominate low-level temperature measurements, so assess the complete analog signal chain rather than converter resolution alone.
推荐
Battery-Cell Monitoring
The ADS1253EG4 is suitable for multi-cell battery monitoring when each cell produces a differential voltage that must be measured against a controlled reference. Its four input channels reduce the number of separate converters in a compact battery-management assembly, and the 24-bit nominal resolution supports detailed cell-voltage characterization. The 20-kSPS maximum rate permits sampling during controlled charge and discharge cycles. The design must still provide a low-noise reference, cell-input isolation or multiplexing as required, and protection for high-energy battery nodes while keeping all converter signals within their specified limits.
推荐
Laboratory and Portable Instrumentation
The ADS1253EG4 supports laboratory and portable instruments that acquire low-level differential sensor signals with high resolution. Four channels enable simultaneous monitoring of transducers, while the 20-kSPS maximum rate suits temperature, strain, force, and slowly varying electrical measurements. Its 24-bit nominal resolution provides a high digital-code range, but usable accuracy still depends on analog front-end noise, reference stability, and digital-filter selection. In portable equipment, low-noise supply design and careful grounding are particularly important because battery variation and ground coupling can degrade the converter's effective measurement performance.
推荐
Process-Control Data Acquisition
The ADS1253EG4 is appropriate for process-control systems that monitor several slowly changing analog quantities and require more resolution than conventional low-resolution SAR converters. Four differential channels can represent pressure, flow, level, or temperature signals referenced to local analog ground, helping suppress noise picked up from industrial wiring. The 20-kSPS maximum rate exceeds the bandwidth of most chemical and thermal processes, while 24-bit nominal resolution allows calibration maps to preserve fine measurement detail. Place input filtering close to the pins, maintain a continuous ground plane, and isolate digital switching from the reference and analog input return paths.
推荐
推荐产品汇总
工程参考数据: ADS1253EG4 ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | ADS1254E | ADS1240E | ADS1251UG4 | ADS1256IDBR | ADS1252E | ADS1255E |
|---|---|---|---|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 16-SSOP | 16-SSOP | 16-SSOP | 16-SSOP | 16-SSOP | 16-SSOP | 16-SSOP |
关键差异点
- Four differential inputs in one converter (对比 ADS1252E)
- 20-kSPS maximum output rate (对比 ADS1254E)
- Single 5 V supply architecture (对比 ADS1240E)
设计说明
Route each differential input as a tightly coupled pair and keep the analog inputs away from SPI clock, chip-select, and switching-regulator nodes. Place the input bypass capacitors and the ADC grounding connection close to the device to minimize trace inductance and ground bounce. Maintain continuous ground-plane return paths beneath the analog section rather than splitting the plane, because a split can increase analog-to-digital coupling even when both sections appear logically separated.
Use separate low-impedance branches for analog and digital bypass capacitors, with the regulator or reference source feeding the analog branch through the layout recommended by the manufacturer datasheet. A 24-bit converter can have very high nominal code resolution, but reference noise and supply ripple can reduce usable accuracy. Check capacitor effective capacitance, voltage derating, dielectric behavior, and regulator output noise before treating the converter's nominal resolution as system accuracy.
Do not substitute an ADS125x-family device solely because it uses a 16-SSOP outline. Confirm pin names, analog input assignments, reference connections, digital-interface timing, supported data rates, channel behavior, reset requirements, and command sequencing. Firmware may also need different initialization or calibration settings for another member of the family. A footprint match is only the first step in establishing replacement compatibility.
合规信息
The manufacturer product information identifies an industrial-grade ADC but does not provide extractable RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declarations. Compliance fields remain unknown until confirmed from the manufacturer documentation.