AD624BDZ - 25 MHz Low-Noise Instrumentation Amplifier | Analog Devices
MPN: AD624BDZ ✗ 停產AD624BDZ 概覽
An instrumentation amplifier is a precision analog signal-conditioning device built to amplify small differential sensor signals while rejecting common-mode noise and interference. The AD624 family is commonly used with load cells, strain gauges, and pressure transducers because it combines differential input handling, high gain accuracy, low noise, and fast settling performance in one integrated circuit. In a typical measurement chain, the sensor converts a physical quantity into a small differential voltage, the AD624BDZ amplifies that voltage, and a downstream ADC or data-acquisition system performs digitization.
The AD624 offers several features suited to precision measurement systems. Its internal trimmed gain options eliminate the need for precision external feedback resistors for common gain settings, while its high bandwidth supports faster acquisition cycles than a conventional slow instrumentation amplifier. The 5 V/µs slew rate helps preserve signal fidelity during large transient responses, and the 15 µs settling time allows the amplifier output to stabilize rapidly between measurements. Low noise makes the device suitable for sensors whose useful signal amplitude is close to the measurement system’s noise floor.
The AD624BDZ uses a three-op-amp instrumentation-amplifier architecture to provide high input impedance and accurate differential gain. Its internal resistors and trim circuitry establish accurate gain without requiring external calibration resistors for the predefined gains. The device is intended for systems operating from dual positive and negative supplies, allowing bipolar sensor signals to remain centered around ground. The manufacturer identifies the AD624 as a precision, low-noise instrumentation amplifier with strong DC and AC performance.
Typical applications include industrial load-cell measurement, strain-gauge bridges, pressure-transducer interfaces, laboratory instrumentation, biomedical signal acquisition, and high-speed data-acquisition systems. The 16-lead ceramic-DIP package makes it suitable for equipment requiring a through-hole component and a conventional industrial or laboratory instrumentation architecture.
When using the AD624BDZ, confirm the supply voltage, gain configuration, input common-mode range, and output swing against the sensor and ADC interface. Place the device close to the transducer to minimize interference pickup on high-impedance sensor lines, and use suitable bypassing capacitors around the power pins. The ceramic DIP package also requires attention to socket or PCB through-hole alignment and thermal management during system assembly.
This page combines manufacturer specifications, package information, pricing references, and practical selection guidance for engineers evaluating the AD624BDZ in precision sensor-conditioning and data-acquisition designs.
直接替換替代品,適用於 AD624BDZ — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: AD624BDZ (相同外形與佔位) — 差異在於 Package, Mounting Type, Input Offset Voltage, Settling Time, Slew Rate.
AD624BD
✅ 直接替換聯絡詢價
查看資料表 →AD624CDZ
✅ 直接替換聯絡詢價
查看資料表 →AD624SD/883B
✅ 直接替換📋 參考替代品(不在目錄中)
AD624BDZ 最大額定值與電氣特性
| Product Type | Precision instrumentation amplifier |
| Number of Amplifiers | 1 circuit |
| Gain-Bandwidth Product | 25 MHz |
| Slew Rate | 5 V/µs |
| Settling Time | 15 µs |
| Input Offset Voltage | 75 µV |
| Supply Voltage Range | ±6 V to ±18 V |
| Trimmed Gain Settings | 1, 100, 200, 500, and 1000 |
| External Gain-Setting Components | Not required for trimmed gains |
| Input Signal Type | Differential |
| 封裝 | 16-lead ceramic DIP |
| 安裝類型 | Through-hole |
| RoHS 狀態 | unknown |
| REACH Status | unknown |
| Automotive Qualification | not_applicable |
AD624BDZ 16-lead ceramic dip 腳位配置指南
AD624BDZ(16-lead ceramic dip 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: AD624BDZ.
請參閱 資料表 以查看完整腳位配置。
典型應用
AD624BDZ 適用於 6 應用s: Load-Cell Measurement, Strain-Gauge Signal Conditioning, Pressure Transducer Interface, High-Speed Data Acquisition, Biomedical Sensor Signal, Laboratory Instrumentation.
Load-Cell Measurement
The AD624BDZ suits load-cell front ends that produce small differential voltages from a bridge sensor. Its precision instrumentation-amplifier architecture provides high common-mode rejection while the low-noise, 25 MHz gain-bandwidth product supports fast measurement acquisition. Internal trimmed gains of 1, 100, 200, 500, and 1000 simplify calibration for common bridge sensitivities. The 5 V/µs slew rate and 15 µs settling time help the system settle quickly between successive readings.
推薦
Strain-Gauge Signal Conditioning
The AD624BDZ is appropriate for strain-gauge bridge conditioning where the useful differential signal is small and susceptible to interference. The device combines a 75 µV input offset specification with low noise, helping preserve measurement integrity in precision strain systems. Its selectable internal gains reduce external resistor requirements for common gain values, while the 16-lead ceramic DIP package fits through-hole instrumentation and test equipment.
推薦
Pressure Transducer Interface
The AD624BDZ can condition the millivolt-level output of a bridge-based pressure transducer while rejecting common-mode voltage present on the sensor lines. Its 25 MHz gain-bandwidth product and 15 µs settling time support fast data-acquisition sequences, and the 5 V/µs slew rate improves response to transient events. Internal trimmed gains from 1 through 1000 provide several sensitivity ranges without requiring a full external gain network.
推薦
High-Speed Data Acquisition
The AD624BDZ fits high-speed acquisition channels that need more bandwidth than a slow precision instrumentation amplifier. Its 25 MHz gain-bandwidth product, 5 V/µs slew rate, and 15 µs settling time allow output settling between measurements. The part is useful where sensor signals must be amplified before ADC sampling while preserving low noise and accurate differential behavior.
推薦
Biomedical Sensor Signal
The AD624BDZ can amplify small differential biomedical sensor signals when the circuit requires accurate offset control and low-noise amplification. The 75 µV input offset specification and internal trimmed gains help establish repeatable measurement conditions, while the fast settling behavior supports rapid signal sampling. Designers should still verify patient-safety isolation requirements, input protection, and applicable medical standards before connecting the amplifier to a clinical system.
推薦
Laboratory Instrumentation
The AD624BDZ is well suited to precision laboratory instruments that combine selectable gain, low noise, and rapid settling. The internal gain choices support repeatable setup for different sensor sensitivities, and the 25 MHz bandwidth allows acquisition systems to sample transient or time-varying inputs. Its through-hole ceramic-DIP package is convenient for laboratory electronics, modular instruments, and serviceable measurement platforms.
推薦
推薦產品摘要
工程參考資料,適用於 AD624BDZ — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | AD624BD | AD624CDZ | AD624SD/883B |
|---|---|---|---|---|
| Package | 16-lead ceramic DIP | 16-lead ceramic DIP | 16-lead ceramic DIP | 16-lead ceramic DIP |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Product Type | Precision instrumentation amplifier | AD624-family instrumentation amplifier | AD624-family instrumentation amplifier | AD624-family instrumentation amplifier |
主要差異化特點
- Fast measurement settling (對比AD624BD)
- Internal gain programming without external resistors (對比AD624CDZ)
- Precision input offset specification (對比AD624SD/883B)
設計說明
Place the AD624BDZ close to the sensor input connector and route the differential input pair as a short, tightly coupled pair. High-impedance transducer lines should be kept away from switching nodes and digital timing signals. The manufacturer’s application guidance and pin-description table should be used to identify the input and supply pins on the 16-lead ceramic-DIP footprint.
The AD624BDZ requires positive and negative supplies in the ±6 V to ±18 V range. Confirm that both rails remain within limits under startup, load transients, and supply ripple. Use local decoupling close to the supply pins, with capacitor values and stability requirements selected from the manufacturer datasheet.
Do not assume that every AD624 suffix is an automatic drop-in replacement. Confirm the ceramic-DIP lead count, pin names, temperature grade, gain implementation, and required external components for AD624BD, AD624CDZ, or AD624SD/883B. For custom gains, follow the manufacturer’s resistor values and layout guidance rather than changing feedback components without stability checks.
The 25 MHz gain-bandwidth product, 5 V/µs slew rate, and 15 µs settling time make bandwidth and settling time important in acquisition systems. Account for the complete signal chain, including sensor capacitance, cable capacitance, output loading, and ADC acquisition time. Provide a defined settling interval before taking a measurement when the source changes rapidly.
合規資訊
Compliance attributes are not specified for the AD624BDZ in the available product information. The 16-lead ceramic-DIP package and ±6 V to ±18 V supply range are identified, while detailed package drawing and ordering-grade information should be checked in the manufacturer datasheet.