LT1012IN8 - Picoamp Input Precision Op Amp | Analog Devices
部品番号: LT1012IN8 ✗ 生産終了LT1012IN8 概要
A precision operational amplifier is a voltage-feedback amplifier designed to minimize error contributions from input bias current, offset voltage, drift, noise, and power-supply variation. Within the broader hierarchy of semiconductor devices, the LT1012 is an analog integrated circuit, and within analog integrated circuits it belongs to the precision operational-amplifier family. Its internally compensated architecture allows it to operate as a closed-loop amplifier without an external compensation capacitor.
The principal benefits of the LT1012IN8 are picoampere-scale input bias current maintained across the full -55 °C to 125 °C temperature range, microvolt-scale input offset voltage, low offset drift, and low voltage and current noise. The manufacturer identifies the device as a universal precision amplifier for instrumentation buffers, low-level signal conditioning, sensor interfaces, battery-powered measurement systems, photodiode amplifiers, and high-impedance transducers. Its low-power operating characteristics are particularly useful when the amplifier must operate from small-cell or dual-cell sources.
Technically, the LT1012 combines low input bias current with low offset voltage and drift rather than optimizing only one parameter. This balance is important because high source impedance can convert input leakage into a substantial input-voltage error, while long-term measurement accuracy can be limited by offset drift. The common-mode and power-supply rejection characteristics also reduce errors caused by signal-source reference shifts and supply variation. Internally compensated operation simplifies closed-loop design while retaining stable operation in precision amplifier topologies.
Typical applications include pH and electrochemical sensor amplification, photodiode and optical-sensor signal chains, high-impedance instrumentation, low-current measurement, precision bridge amplifiers, and battery-operated test equipment. In these systems, the LT1012 can serve as a non-inverting buffer, inverting amplifier, transimpedance amplifier, or instrumentation-amplifier input stage. The 5 mA load-current capability supports the low-power signal paths associated with portable and industrial measurement systems.
Design should begin by checking input common-mode range, output swing, supply current, and stability for the intended feedback network. Input-bias-current error should be calculated using the source impedance, while offset and drift requirements should be evaluated over the actual temperature span. Because the LT1012IN8 is a legacy PDIP device, board layout, socket availability, thermal exposure, and obsolescence-risk management may influence lifecycle planning.
This product record combines manufacturer electrical characteristics, package and ordering information, source-document links, practical application guidance, and a structured comparison of confirmed same-package alternatives. It also highlights the engineering trade-offs that matter when selecting a picoamp-input precision amplifier for high-impedance, low-power measurement systems.
ドロップイン代替品: LT1012IN8 — 同一パッケージでピン互換。PCBの作り直しが必要な異なるパッケージの部品は除外されています。
このシリーズのバリエーション
同一シリーズでドロップイン互換のモデル: LT1012IN8 (同一形状・フットプリント) — 相違点: Compensation, Input Bias Current, Input Offset Voltage, Operating Temperature Range, Package.
LT1012IN8#PBF
✅ ドロップイン📋 参考代替品(カタログ未掲載)
LT1012AIN8
✅ ドロップイン📋 参考代替品(カタログ未掲載)
LT1012CN8
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
LT1012DIN8
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
LT1012BIN8
✅ ドロップイン ⚠️ 仕様未検証📋 参考代替品(カタログ未掲載)
LT1012IN8 最大定格&電気的特性
| Product Type | Single, internally compensated precision operational amplifier |
| Input Bias Current | Picoampere class |
| Input Offset Voltage | Microvolt class |
| Offset Drift | Low drift with time and temperature |
| Voltage Noise | Low noise |
| Current Noise | Low noise |
| Output Load Current | 5 mA |
| Battery Power Dissipation | 1 mW on two Ni-Cad batteries |
| Open-Loop Voltage Gain | 1,000,000 V/V |
| 動作温度範囲 | -55 °C to 125 °C |
| Common-Mode Rejection | Extremely high; numeric ratio not stated |
| Power-Supply Rejection | Extremely high; numeric ratio not stated |
| Compensation | Internal |
| Circuit Count | 1 amplifier |
| パッケージ | 8-pin PDIP |
| 実装タイプ | Through-hole |
LT1012IN8 ピン構成
| ピン 1 | OFFSET NULL — Offset-voltage null adjustment |
| ピン 2 | INVERTING INPUT — Inverting input terminal |
| ピン 3 | NON-INVERTING INPUT — Non-inverting input terminal |
| ピン 4 | V- — Negative power-supply terminal |
| ピン 5 | OFFSET NULL — Offset-voltage null adjustment |
| ピン 6 | OUTPUT — Amplifier output |
| ピン 7 | V+ — Positive power-supply terminal |
| ピン 8 | NC — Not connected |
主な用途
LT1012IN8 の用途: 6 件s: Electrochemical Sensor Signal Conditioning, Photodiode Amplification, Battery-Powered Measurement, Precision Bridge Amplifier, High-Impedance Instrumentation Buffer, Low-Current Sensor Interface.
Electrochemical Sensor Signal Conditioning
The LT1012IN8 fits electrochemical, pH, and ion-sensor interfaces because picoampere-class input bias current limits leakage-generated error at high source impedance. Its microvolt-class offset voltage and low offset drift support stable measurement when the sensor output is small and the input reference can vary. The amplifier can operate as a non-inverting preamplifier or transimpedance stage, while 5 mA output-current capability suits the low-power measurement paths commonly used in portable analyzers. A principal trade-off is its legacy 8-pin PDIP format, so new compact instrument designs must account for board area and long-term sourcing.
おすすめ
Photodiode Amplification
The LT1012IN8 is suitable for low-current photodiode and optical-sensor amplification because picoampere input bias current reduces error current relative to many conventional precision amplifiers. Its low voltage and current noise preserve small-signal fidelity, while the 5 mA output-current rating supports the feedback network and following stages. The amplifier can implement a transimpedance configuration with a feedback resistor and compensation capacitor selected for the detector capacitance and required bandwidth. Designers should verify stability, input capacitance, and achievable bandwidth because low input current alone does not guarantee a usable transimpedance bandwidth.
おすすめ
Battery-Powered Measurement
The LT1012IN8 supports battery-powered measurement systems because Analog Devices reports approximately 1 mW power dissipation when operating from two Ni-Cad batteries, with output load capability of 5 mA. Low power reduces the thermal and battery-current burden of portable instrumentation, while picoampere input bias current is valuable when sensors present high source impedance. The internally compensated amplifier simplifies implementation as a voltage buffer or gain stage. The design should still include low-leakage PCB materials and clean assembly practices because board contamination can overwhelm the extremely small bias current in high-impedance nodes.
おすすめ
Precision Bridge Amplifier
The LT1012IN8 can serve as an input or gain stage in precision bridge measurements where offset voltage, drift, and common-mode errors directly affect accuracy. Its microvolt-class offset voltage and high common-mode rejection suit low-level sensor bridges, while the 5 mA output-current capability supports conventional resistive feedback networks. The device may be paired with matched resistors and a differential stage to improve rejection of excitation drift. Before committing to the design, calculate input-bias-current error from bridge output impedance and confirm that signal common-mode voltage remains within the amplifier’s operating limits.
おすすめ
High-Impedance Instrumentation Buffer
The LT1012IN8 fits instrumentation buffering when source impedance is high enough that input leakage becomes a material measurement error. Picoampere-class bias current, maintained over the full -55 °C to 125 °C range, helps preserve signal integrity in capacitive sensors, electrometers, and laboratory probes. The microvolt offset specification supports precision signal conditioning, and the low-noise characteristics improve the signal-to-noise ratio for small sensor outputs. Layout remains critical: minimize exposed PCB area around inputs, use guarding where appropriate, and prevent flux residue or humidity from creating leakage paths comparable to the specified bias current.
おすすめ
Low-Current Sensor Interface
The LT1012IN8 is appropriate for low-current sensors whose output impedance makes amplifier input leakage the dominant error term. Its picoampere bias current reduces the error voltage generated across that impedance, while microvolt offset and low drift preserve accuracy over time and temperature. The 5 mA output-current capability is sufficient for common resistive feedback networks and modest downstream loads. The internally compensated topology supports straightforward closed-loop implementation. Engineers should still validate the complete signal path against sensor leakage, PCB cleanliness, supply noise, temperature range, and the required settling time.
おすすめ
おすすめ製品の概要
エンジニアリング参考データ: LT1012IN8 — 比較、設計ガイダンス、コンプライアンス情報。
選定ガイド
代替品との比較
| パラメータ | この製品 | LT1012IN8#PBF | LT1012AIN8 | LT1012CN8 | LT1012DIN8 | LT1012BIN8 |
|---|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP | 8-pin assis PDIP | 8-pin PDIP |
| Product Type | Precision operational amplifier | Precision operational amplifier | Precision operational amplifier | Precision operational amplifier | Precision operational amplifier | Precision operational amplifier |
主な差別化要因
- Very low input bias current for precision high-impedance measurements (vs LT1012IN8#PBF)
- Full-temperature picoampere bias-current performance (vs LT1012CN8)
- Low-power operation with useful output-current capability (vs LT1012AIN8)
設計ノート
Keep the non-inverting input, inverting input, and feedback-resistor connections compact and isolated from high-impedance leakage paths. For picoampere-class operation, use a clean board surface, remove flux residues, avoid moisture traps, and consider guarding. The manufacturer rates the input bias current in picoamperes, so contamination currents comparable to that scale can dominate the measurement error.
Use the lowest supply voltage that still satisfies input common-mode range and output swing requirements. Analog Devices reports approximately 1 mW dissipation with two Ni-Cad batteries and a 5 mA load-current capability, making the LT1012IN8 suitable for low-power precision systems. Check supply-current behavior across temperature because bias-current and noise specifications do not by themselves characterize total power consumption.
Do not treat the IN8, AIN8, CN8, DIN8, or BIN8 suffixes as electrically interchangeable without checking the ordering table. The suffix may change temperature grade, qualification, or termination even though the device retains the 8-pin PDIP footprint. Confirm common-mode range, supply limits, offset limits, and lifecycle status for the exact production code before releasing a new PCB.
Calculate input-bias-current error as input bias current multiplied by total source impedance, and include PCB leakage, socket leakage, and protective-device leakage where relevant. Offset error and drift should be evaluated over the intended temperature span rather than at room temperature alone. These calculations help determine whether the LT1012IN8’s picoampere and microvolt characteristics materially improve the measurement.
コンプライアンス情報
The LT1012IN8#PBF ordering designation identifies a lead-free finish, but the compliance status of the original LT1012IN8 code cannot be inferred from that designation. RoHS, REACH, AEC-Q100, halogen-free, and conflict-minerals status require confirmation from the manufacturer or current material documentation.