AS7050 Overview

The ams OSRAM AS7050 is a biosignal sensor analog front-end (AFE) that provides up to 8 LED driver outputs, samples up to 6 photodiode inputs, and supports external electrodes, all housed in a small Wafer-Level Chip-Scale Package (WLCSP) with I2C output. It enables synchronized PPG and ECG acquisition in a single vital-sign sensing IC.

A biosignal analog front-end is the mixed-signal circuit stage that converts weak physiological signals - optical photoplethysmogram (PPG) current from photodiodes, electrical electrocardiogram (ECG) potentials from skin electrodes, and galvanic skin resistance (GSR) - into digitized data for a host microcontroller. Within the signal-chain hierarchy, the AFE sits between the raw sensor elements (LEDs, photodiodes, electrodes) and the digital processing domain, making it the precision heart of any wearable health monitoring system.

Key differentiating features include up to 8 LED driver outputs and 6 photodiode input pins, giving exceptional flexibility for multi-wavelength, multi-site optical arrangements in reflective or transmissive PPG topologies. The embedded low-noise ECG analog front-end meets IEC 60601-2-47 requirements, a significant advantage for medical-grade designs. Synchronized PPG and ECG acquisition enables advanced parameters such as pulse transit time and blood-pressure trend estimation. The thin WLCSP profile suits height-constrained products such as true wireless earbuds, smart rings, and watch backplates.

Architecturally, the AS7050 is the next generation of the ams OSRAM vital-sign sensor family, integrating low-noise transimpedance paths, programmable LED current sources, an electrode-based ECG channel, and a GSR measurement stage under I2C control. Flexible time-slot scheduling allows PPG, ECG, and GSR acquisitions to be interleaved with low average power, critical for battery-operated wearables.

Typical applications include optical heart-rate and ECG monitoring platforms, smartwatch and fitness-band sensor stacks, hearable in-ear PPG for earbuds, and connected medical and health devices requiring multi-modal biosignal capture. The multi-LED/multi-PD arrangement supports SpO2-style dual-wavelength configurations without external analog circuitry.

Design consideration: the WLCSP package requires accurate pad-matched PCB land patterns and careful LED optical crosstalk management; keep photodiode input traces short and shielded to preserve the low-noise front-end performance.

This page synthesizes distributor sourcing data, drop-in variant options, and practical design guidance not found in the manufacturer short datasheet, with all key values verified against ams OSRAM and Mouser sources as of 2026-10-11.

Drop-in alternatives for AS7050 — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.

Variants in this series

Same-series models that are drop-in compatible with AS7050 (same form factor and footprint) — differing in Package, External Electrode Support, Product Type, RoHS Status.

ams OSRAM
Package: WLP (wafer-level package), lead-free
Product Type: Biosignal Sensor Analog Front End (AFE)
RoHS Status: Lead-free (LF) ordering option indicated
Compare with AS7050 →
ams OSRAM
Package: WLP
External Electrode Support: Yes
Product Type: Biosignal Sensor Analog Frontend (AFE)
Compare with AS7050 →

Quick Comparison Tool — Select alternative parts for side-by-side comparison:

AS7050-BWLM

✅ Drop-In
ams OSRAM
📦 WLCSP
Biosignal Sensor Analog Front End (AFE) · PPG, ECG, GSR · I2C · WLP (wafer-level package), lead-free · Tape & Reel · ams OSRAM · Vital Sign Monitoring / Biomonitoring · REV.C

✓ In Stock

Contact for price

View Datasheet →

AS7050-BWLT

✅ Drop-In
ams OSRAM
📦 WLCSP
Biosignal Sensor Analog Frontend (AFE) · PPG, ECG, GSR · up to 8 · up to 6 · Yes · I2C · WLP · WLP LF (lead-free)

✓ In Stock

$2.07 / Unit

View Datasheet →

AS7050-BWLM_REV.C

✅ Drop-In
📦 WLCSP
revision-marked AS7050-BWLM (REV.C die revision), identical pinout and function, I2C biomonitoring output

📋 Reference alternative (not in catalog)

AS7050 Maximum Ratings & Electrical Characteristics

Function Biosignal Sensor Analog Front-End (PPG, ECG, GSR)
LED Driver Outputs Up to 8
Photodiode Inputs Up to 6
External Electrode Support Yes (ECG/GSR)
Synchronized PPG + ECG Acquisition Yes
Communication Interface I2C
Package WLCSP (Wafer-Level Chip-Scale Package)
ECG Standard Compliance Meets IEC 60601-2-47 requirements
Noise Performance (ECG AFE) Embedded low-noise analog front-end
Mounting Type Surface Mount
Typical Applications Heart-rate and ECG monitoring, smart devices, earbuds
Ordering Variants AS7050-BWLM, AS7050-BWLT, AS7050-BWLM_REV.C

AS7050 wlcsp (wafer-level chip-scale package) Pin Configuration Guide

Pin configuration for AS7050 (wlcsp (wafer-level chip-scale package) package). This power device features gate, drain, and source terminals. For non-polarized packages, refer to the manufacturer datasheet for exact pin 1 orientation and footprint details. Common applications include power supply design, motor driving, and load switching.

wlcsp (wafer-level chip-scale package) package pinout diagram for AS7050

No detailed pinout data available for AS7050.

Refer to the datasheet for full pin configuration.

Typical Applications

AS7050 is suitable for 6 applications: Optical Heart-Rate (PPG) Monitoring, ECG Monitoring for Wearables, True Wireless Earbuds In-Ear Sensing, Smartwatch Multi-Modal Sensor Platforms, Galvanic Skin Response (GSR) and Stress Sensing, Connected Medical and Telehealth Devices.

💊

Optical Heart-Rate (PPG) Monitoring

The AS7050 fits wrist-worn and ring-form heart-rate monitoring because its 8 LED drivers and 6 photodiode inputs let one IC drive multiple green/red/IR LED wavelengths and read multiple photodiode sites, improving signal quality across skin tones and motion conditions. In a typical reflective topology, scheduled time slots pulse each LED while the corresponding photodiode current is converted by the low-noise front-end and digitized for the host MCU over I2C. Because acquisition timing is synchronized, multi-wavelength ratios (the basis of SpO2-style estimation) can be computed without external analog circuitry, reducing BOM height and power compared with discrete TIA plus LED-driver designs.

💊

ECG Monitoring for Wearables

The embedded ECG analog front-end of the AS7050 accepts external electrodes and is specified to meet IEC 60601-2-47 requirements, per the Mouser product data, which materially shortens the compliance path for ambulatory ECG features in smartwatches, patches, and medical wearables. Electrode-derived ECG is acquired in the same synchronized schedule as PPG, enabling pulse-transit-time style computations that correlate optical and electrical cardiac events. Designers should keep electrode input traces guarded and high-impedance, place the AS7050 close to the electrode contacts, and budget for dry-electrode contact noise, which typically dominates over the AFE's own low-noise floor in real enclosures.

🎧

True Wireless Earbuds In-Ear Sensing

The thin WLCSP package of the AS7050-BWLM is explicitly called out by ams OSRAM as suitable for height-constrained earbud solutions, where every tenths-of-a-millimeter of sensor-stack height matters for acoustic fit and shell ergonomics. In-ear PPG benefits from the AFE's multiple photodiode inputs, which allow sampling of two sensor sites to reject motion artifacts from loose ear-tip contact. The I2C interface integrates naturally with the low-power MCU inside a BT SoC audio platform, and scheduled low-duty-cycle LED pulses keep average current in the microamp-to-milliamp range compatible with small hearing-aid-class cells. Optical crosstalk shielding inside the earbud shell is the dominant layout constraint.

📱

Smartwatch Multi-Modal Sensor Platforms

A smartwatch backplate typically combines optical windows and ECG electrodes; the AS7050 is purpose-built for exactly this combination, delivering PPG, ECG, and GSR channels in one IC so the sensor stack stays thin and the optical center-to-electrode geometry can be tightly controlled. With 8 LED drivers, designers can implement 4-wavelength optical arrays for advanced metrics while retaining headroom for proximity or ambient-light channels on the 6 photodiode inputs. Mouser lists smart devices among the primary applications. Firmware-side, time-slot scheduling in the AFE means the host only manages a single acquisition engine over I2C, simplifying power-state management during continuous background heart-rate monitoring.

🧩

Galvanic Skin Response (GSR) and Stress Sensing

The AS7050 supports galvanic skin resistance measurement through its external-electrode path, enabling stress and arousal tracking alongside cardiac metrics without a second dedicated AFE. In practice, two dry-contact electrodes on the wrist or ring inner surface drive a small excitation through the skin, and the AFE conditions and digitizes the resulting GSR response in scheduled slots between PPG and ECG acquisitions. Because GSR signals drift slowly with electrode-skin impedance, the shared synchronization of all three modalities lets algorithms cross-validate stress events against heart-rate and HRV trends. Keep electrode cables short and shielded; sweat-channel geometry strongly influences baseline drift and repeatability.

🖥️

Connected Medical and Telehealth Devices

For clinical-grade ambulatory monitors and telehealth patches, the AS7050 offers a compliant ECG front-end (targeting IEC 60601-2-47) plus synchronized PPG, allowing one sensor IC to feed pulse-oximetry-style optical data and diagnostic-quality ECG into the same capture stream. Mouser explicitly lists medical and health sensor applications for the AS7050 family. In battery-powered patch form factors, the WLCSP's minimal footprint and the AFE's scheduled acquisition reduce average current, extending wear time; the design team must still implement patient-isolation, defibrillation protection, and biocompatibility at system level, which the AFE does not replace. Full datasheet parameters should be pulled under NDA for regulatory documentation.

What is the AS7050 biosignal sensor and what does it measure?
The AS7050 is a biosignal sensor analog front-end (AFE) from ams OSRAM that detects photoplethysmogram (PPG), electrocardiogram (ECG), and galvanic skin resistance (GSR) signals. According to the ams OSRAM short datasheet (DS001051), it provides up to 8 LED driver outputs and samples up to 6 photodiode inputs, with synchronized PPG and ECG acquisition and an I2C interface, enabling multi-modal vital-sign monitoring in wearables such as smartwatches and earbuds.
What package does the AS7050 come in and is it suitable for earbuds?
Yes, the AS7050 is housed in a small Wafer-Level Chip-Scale Package (WLCSP) whose thin profile is explicitly designed for height-constrained solutions such as true wireless earbuds, according to the ams OSRAM AS7050-BWLM datasheet. The WLCSP format minimizes total sensor-stack height behind a watch backplate or earbud shell, though it requires pad-matched PCB land patterns and careful handling of photodiode trace routing to preserve the low-noise front-end performance.
Does the AS7050 ECG front-end meet medical requirements?
The embedded ECG analog front-end in the AS7050 meets IEC 60601-2-47 requirements, per the Mouser product listing for the ams OSRAM AS7050-BWLT. IEC 60601-2-47 is the particular standard for ambulatory electrocardiographic systems, so using this AFE significantly eases compliance work for medical-grade heart-rate and ECG monitoring products. Designers should still validate the complete system - electrodes, filtering, and patient-isolation circuits - against the applicable regulatory framework.
How many LEDs and photodiodes can the AS7050 drive?
The AS7050 provides up to 8 LED driver outputs and samples up to 6 photodiode inputs, and additionally supports external electrodes, according to the ams OSRAM datasheet. This flexibility allows several LED and photodiode arrangements across different applications - for example, dual-wavelength SpO2-style optical stacks, multi-site PPG, or reflective green-LED heart-rate sensing - without redesigning the front-end. Time-slot scheduling interleaves the acquisitions to manage average power consumption.
What is the price of AS7050-BWLM and where can I buy it?
AS7050 family pricing is quote-based at many authorized distributors; stock and pricing for variants such as AS7050-BWLM_REV.C can be compared on DigiKey, Mouser, TrustedParts.com, and Octopart, which lists 5 distributors for the part. As of 2026-10-11, XAIPART lists indicative tier pricing from 6.90 USD at qty 1 down to about 4.48 USD at qty 1000, but you should request a formal quote for volume commitments since biosensor allocation can vary.
What is the difference between AS7050-BWLM and AS7050-BWLT?
AS7050-BWLM and AS7050-BWLT are ordering variants of the same AS7050 die in the same WLCSP package; per ams OSRAM datasheets the suffixes denote different packaging/handling configurations, with the silicon and functional specification identical across both. Electrically and functionally they are interchangeable, and both expose 8 LED drivers, 6 photodiode inputs, ECG/GSR electrode support, and I2C. Confirm the preferred suffix with your distributor based on reel quantity and moisture-sensitivity-level handling requirements.
What is the best drop-in replacement for AS7050?
There is no verified cross-brand drop-in replacement for the AS7050; the closest drop-in options are same-family ams OSRAM ordering variants such as AS7050-BWLM, AS7050-BWLT, and AS7050-BWLM_REV.C, which share the identical WLCSP footprint and pinout. For a redesign rather than a drop-in swap, Maxim/ADI optical AFE parts (for example the MAX86140/MAX86141 PPG family) offer comparable PPG functionality but in different packages and pinouts, requiring PCB changes and requalification. Our web search found no pin-compatible competitor equivalent.
Is there a cross-brand equivalent for the AS7050 biosensor AFE?
No verified cross-brand pin-compatible equivalent exists for the AS7050 in the same WLCSP package, based on our cross-reference searches of DigiKey, Octopart, and manufacturer cross-reference tools as of 2026-10-11. Analog Devices MAX8614x PPG AFEs, TI AFE44x0 series, and Renesas/IDT optical AFEs are functional alternatives in the biosignal AFE category, but all differ in package, pinout, and channel count, so any cross-brand migration is a redesign-level change, not a drop-in replacement.
When should I choose the AS7050 over a PPG-only AFE like the MAX86141?
Choose the AS7050 when your product needs synchronized multi-modal biosignal capture - PPG plus electrode-based ECG plus GSR - in a single thin WLCSP part, especially for medical-leaning designs since its ECG front-end targets IEC 60601-2-47. Choose a PPG-only AFE such as the MAX86141 if you only need optical heart-rate/SpO2 and want a wider second-source market or different package options. The AS7050 trades ecosystem breadth for integration: fewer external components versus two separate PPG and ECG front-ends.
Where can I download the AS7050 datasheet PDF?
The official AS7050 short datasheet (document DS001051) is available from Mouser at mouser.com/datasheet/2/588/AS7050_ShortDatasheet_DS001051_1_00-2942360.pdf, and mirrored copies exist on alldatasheet.com and datasheet4u.com. The authoritative source is always the ams OSRAM product page at ams-osram.com, where registration may unlock the full datasheet and application notes. Beware that short datasheets may omit register maps that are released under NDA for volume customers.
Where can I find the AS7050 pinout and land pattern?
The AS7050 pinout is defined in the ams OSRAM datasheet DS001051 together with the recommended WLCSP land pattern; because this is a wafer-level chip-scale package, the pinout is a ball-map array rather than a leaded pin numbering, so consult the datasheet ball-map table directly rather than generic pin diagrams. XAIPART does not reproduce the full ball map here because we could not verify every ball assignment from the provided data; always cross-check against the current datasheet revision before routing the PCB.
Is AS7050 the same as AS7050-BWLM_REV.C?
AS7050-BWLM_REV.C is a revision-marked ordering code for the AS7050-BWLM variant, so it is the same AS7050 silicon and functionality with a formal die/package revision letter appended for traceability. DigiKey lists it as a biomonitoring sensor with I2C output from ams OSRAM, in WLCSP, tape-and-reel, LF (lead-free) packaging. When sourcing, match the exact ordering code including the REV suffix if your qualification and change-notification process depends on a specific silicon revision.
Is the AS7050 in stock and what is the lead time?
Availability varies by suffix: DigiKey shows the AS7050-BWLM_REV.C as buy-now/ships-today stock at times, while other AS7050 variants are often factory-order items with lead times that can extend to many weeks for ams OSRAM biosensor products, as reflected on TrustedParts.com. As of 2026-10-11 you should check live distributor stock at DigiKey, Mouser, and TrustedParts before committing a schedule. XAIPART marks this part as quote-based (BackOrder) pending confirmation of current allocation.
What are the key specifications of AS7050 that engineers should know?
Engineers evaluating the AS7050 should know: it is a biosignal AFE from ams OSRAM detecting PPG, ECG, and GSR; it provides up to 8 LED driver outputs and up to 6 photodiode inputs plus external electrode support; it performs synchronized PPG and ECG acquisition; the embedded ECG front-end targets IEC 60601-2-47 compliance; it communicates via I2C; and it is packaged in a thin WLCSP suited to earbuds and wearables. Supply voltage, LED current range, and ADC resolution require the full datasheet (DS001051) for exact values.

Engineering reference data for AS7050 — comparison, design guidance, and compliance information.

Selection Guide

Choose the AS7050 when your product needs synchronized PPG plus electrode-based ECG (and optionally GSR) in one thin WLCSP device - typical cases are smartwatch backplates, ECG-capable fitness bands, in-ear sensing for earbuds, and ambulatory medical patches targeting IEC 60601-2-47. Within the family, select the suffix (BWLM, BWLT, or BWLM_REV.C) by sourcing availability and your change-control requirements, since the silicon is identical. Choose a PPG-only alternative such as the ADI MAX8614x or TI AFE44x0 series if you need only optical sensing and want a broader multi-source market, accepting a redesign: those parts differ in package and pinout and lack the integrated ECG electrode front-end. For regulated medical products, request the full ams OSRAM datasheet and change notifications before qualification.

Comparison with Alternatives

Parameter This Product AS7050-BWLM AS7050-BWLT AS7050-BWLM_REV.C
Package WLCSP WLCSP - same WLCSP - same WLCSP - same
Brand ams OSRAM ams OSRAM ams OSRAM ams OSRAM
LED Driver Outputs Up to 8 Up to 8 Up to 8 Up to 8
Photodiode Inputs Up to 6 Up to 6 Up to 6 Up to 6
ECG Electrode Support Yes (IEC 60601-2-47) Yes (IEC 60601-2-47) Yes (IEC 60601-2-47) Yes (IEC 60601-2-47)
Interface I2C I2C I2C I2C
Synchronized PPG + ECG Yes Yes Yes Yes

Key Differentiators

  • Integrated multi-modal biosignal capture (PPG + ECG + GSR) (vs MAX86141)
  • Highest channel flexibility in its class (vs AFE4400)
  • Earbud-optimized package height (vs AS7050-BWLM_REV.C)

Design Notes

WLCSP assembly discipline is mandatory for the AS7050: the package requires a pad-matched land pattern per the ams OSRAM datasheet, NSMD pads, and a controlled reflow profile since there are no leads to absorb stress. Route photodiode input traces as short as possible and guard them with ground to preserve the low-noise front-end; any leakage or pickup at these high-impedance nodes appears directly as PPG noise. Keep LED driver return currents away from photodiode grounds to avoid injecting switching artifacts into the optical channel.

Optical crosstalk is the dominant error source in reflective PPG stacks: isolate each LED-photodiode pair with a light-blocking barrier (epoxy wall or molded frame) and specify low-fluorescence epoxy in the optical window. Because the AS7050 offers up to 8 LED drivers and 6 photodiode inputs, plan the mechanical stack so unused channels do not create parasitic reflection paths. Follow the LED scheduling recommended in the manufacturer datasheet so adjacent time slots do not share wavelengths that couple through the barrier.

Power the AS7050 analog domain from a dedicated low-noise LDO rather than a shared buck output; LED pulse currents create large transient loads that modulate a shared rail and appear as baseline wander in ECG and GSR channels. Add local decoupling at each supply pin per the datasheet recommendation, and sequence the AFE supply before the electrode front-end if separate rails are used. Estimated: scheduling PPG at 25 Hz with short LED pulses typically keeps average AFE power well within wearable battery budgets, but verify with the full datasheet current tables.

Compliance Information

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Lead Free
Unknown
Halogen Free
Unknown
Conflict Minerals
Unknown

ECG front-end specified to meet IEC 60601-2-47 per Mouser product data. DigiKey lists AS7050-BWLM_REV.C as WLP LF (lead-free) packaging; formal RoHS/REACH declarations must be obtained from ams OSRAM.

Data verified on: 2026-10-11 — data verified and curated by XAIPART's component engineering team

Related Searches

AS7050 datasheet ams OSRAM AS7050 biosignal sensor AS7050-BWLM WLCSP PPG ECG AFE AS7050 pinout I2C biomonitoring sensor AS7050 heart rate earbuds sensor AS7050 vs MAX86141 AS7050 drop-in replacement equivalent buy AS7050-BWLT price what is AS7050 biosignal sensor analog frontend wearable ECG AFE IEC 60601-2-47 AS7050 stock lead time distributor GSR galvanic skin response sensor IC

Related Components & Terms

ams OSRAM AS7050 AS7050-BWLM AS7050-BWLT AS7050-BWLM_REV.C analog front-end AFE biosignal sensor PPG photoplethysmogram ECG IEC 60601-2-47 GSR WLCSP wafer-level chip-scale package I2C surface mount heart-rate monitoring wearables earbuds RoHS transimpedance amplifier LED driver photodiode input biomonitoring
Quick Quote RFQ
Fill in complete details — our sales team will respond within 24 hours
Part Number Manufacturer Package QTY Target Price Extended
Total: $0.00 USD
✓
Quote submitted!

We will respond to your email within 24 hours

1
RFQ Submitted
2
Quote Received
3
Order Placed
4
Payment
5
Shipped
6
Delivered
View RFQ Details