TS942AIN - Dual Rail-to-Rail Micropower Op Amp | STMicroelectronics
MPN: TS942AIN ✗ End of LifeTS942AIN Overview
An operational amplifier is an analog integrated circuit that amplifies the voltage difference between its two inputs while offering high input impedance, low output impedance, and stable operation around the supply rails. The TS942AIN belongs to the broader hierarchy of operational amplifier, analog amplifier, signal-conditioning IC, and power-management-dependent semiconductor. Its rail-to-rail output stage is useful when the required output signal must approach the positive or negative supply limit.
The principal features of the TS942AIN include low quiescent current, dual-channel configuration, rail-to-rail output capability, and operation from 2.5 V to 10 V. The low 1.2 uA per-channel supply current reduces the burden on battery-powered or energy-harvesting systems. A typical output current of 5 mA is suitable for normal low-frequency analog signal paths, subject to the load, voltage, and stability limits defined by the manufacturer.
The TS94x family is characterized for operation from 2.5 V to 10 V over a -40 °C to +85 °C temperature range. TS942AIN is the dual-amplifier version with a Mini DIP package. The 8-pin through-hole package supports conventional PCB assembly and is convenient when a compact surface-mount package is not required. Rail-to-rail output behavior improves signal swing in low-voltage instrumentation, sensor interfaces, and portable measurement circuits.
Typical applications include portable sensor conditioning, low-power monitoring, current-loop interfaces, and low-voltage analog signal processing. In a sensor circuit, the TS942AIN can amplify a small transducer voltage while operating from a compact supply. In a portable measurement system, its micropower operation helps limit standby consumption. When driving larger capacitive loads or operating at higher frequencies, the designer should verify the applicable stability and load-current limits in the manufacturer datasheet.
For PCB design, place the device close to the signal source and preserve short analog input traces to reduce susceptibility to noise and parasitic loading. Decouple the power supply with a local bypass capacitor and route return currents away from sensitive signal paths. The manufacturer product page and the TS942AIN datasheet should be used to confirm the exact pin assignment, electrical limits, input common-mode range, output swing, and recommended operating conditions.
This page combines the manufacturer family information with practical selection guidance, package details, sourcing information, and engineering considerations. It is intended to help engineers determine whether the TS942AIN’s dual low-power architecture and 8-pin Mini DIP format fit a specific analog design before finalizing the schematic and PCB layout.
Drop-in alternatives for TS942AIN — same package, pin-to-pin compatible. Different-package parts requiring PCB rework are excluded.
Variants in this series
Same-series models that are drop-in compatible with TS942AIN (same form factor and footprint) — differing in Package, Mounting Type, Number of Amplifier Channels, Number of Pins.
TS942AID
✅ Drop-InContact for price
View Datasheet →TS942AID
✅ Drop-InContact for price
View Datasheet →TS942ID
✅ Drop-In ⚠️ Specs UnverifiedContact for price
View Datasheet →TS942AID
✅ Drop-In ⚠️ Specs UnverifiedContact for price
View Datasheet →TS942AID
✅ Drop-In ⚠️ Specs UnverifiedContact for price
View Datasheet →TS942AIN Maximum Ratings & Electrical Characteristics
| Number of Amplifiers | 2 channels |
| Amplifier Type | General-purpose operational amplifier |
| Output Type | Rail-to-rail |
| Supply Voltage Range | 2.5 V to 10 V |
| Quiescent Current per Channel | 1.2 uA typical |
| Typical Output Current | 5 mA |
| Operating Temperature Range | -40 °C to +85 °C |
| Package | 8-DIP, 0.300 inch pitch, 7.62 mm |
| Mounting Type | Through-hole |
| RoHS Status | Compliant |
TS942AIN 8-dip, 0.300 inch pitch, 7.62 mm Pin Configuration Guide
Pin configuration for TS942AIN (8-dip, 0.300 inch pitch, 7.62 mm package). This analog component features input, output, and power supply pins. Refer to the manufacturer datasheet for offset null, compensation, and enable pin configurations. Ideal for signal conditioning and amplifier circuits.
No detailed pinout data available for TS942AIN.
Refer to the datasheet for full pin configuration.
Typical Applications
TS942AIN is suitable for 6 applications: Battery-Powered Sensor Conditioning, Portable Industrial Monitoring, Low-Voltage Buffering, Current-Loop Interface, Medical Sensor Interface, Low-Power Data Acquisition.
Battery-Powered Sensor Conditioning
The TS942AIN is well suited to conditioning low-level sensor signals in battery-powered equipment because each amplifier channel draws approximately 1.2 uA at typical conditions. The dual configuration can amplify or buffer two related channels while operating from a supply between 2.5 V and 10 V. Rail-to-rail output behavior helps preserve signal swing in low-voltage systems. Designers should verify the input common-mode range, offset voltage, and noise against the sensor specification, then place the amplifier close to the source to minimize trace noise and parasitic loading.
Recommended
Portable Industrial Monitoring
The TS942AIN can monitor slow analog signals in portable instrumentation where each channel’s approximately 1.2 uA supply current helps extend operating time. Its 2.5 V minimum supply supports compact sensor systems, while the -40 °C to +85 °C family rating covers a broad range of industrial environments. Use the dual amplifier for paired conditioning channels and confirm that the required gain, input common-mode range, and output accuracy fit the measurement chain. A stable local bypass capacitor and short analog traces are important in field environments with electrical noise.
Recommended
Low-Voltage Buffering
The TS942AIN can buffer low-voltage signals when the source impedance would make downstream loading unacceptable. Its dual general-purpose topology allows one channel to buffer a sensor and the other to support a second signal path. The 5 mA typical output current is suitable for moderate loads, while the rail-to-rail output stage increases available swing near the supply limits. Before implementation, verify the load capacitance, output stability, and exact output-voltage limits from the manufacturer electrical characteristics.
Recommended
Current-Loop Interface
The low-power dual TS942AIN can support the input and output stages of a low-voltage current-loop interface when the loop bandwidth is within the amplifier’s capability. Its 2.5 V to 10 V operating range suits compact process-control electronics, and the rail-to-rail output helps drive the required current within the available supply headroom. The design must confirm input bias current, offset, gain-bandwidth, common-mode range, and load capability in the manufacturer datasheet. Decouple the supply near the IC and keep feedback components away from switching traces.
Recommended
Medical Sensor Interface
The TS942AIN can serve as a low-power amplifier in a medical sensor interface when its input offset, noise, bias current, and common-mode performance meet the measurement requirements. Its dual channels support paired sensing or buffering, and the approximately 1.2 uA per-channel supply current limits battery drain. The 2.5 V to 10 V supply range accommodates compact acquisition systems. Because safety-critical medical designs require application-specific validation, engineers should compare the complete electrical limits, isolation strategy, and leakage requirements before integrating the device into patient-contact circuitry.
Recommended
Low-Power Data Acquisition
A TS942AIN-based front end can amplify or buffer two channels in a compact, low-power data-acquisition system. The dual configuration reduces the component count compared with separate single amplifiers, while the 2.5 V minimum operating voltage supports low-voltage sensors. Its typical 1.2 uA per-channel supply current is advantageous for long-duration acquisition, provided the selected sample rate is compatible with the amplifier bandwidth. Check input bias current for high-impedance sources, use short guarded traces, and ensure the output stage remains stable with the ADC sampling network.
Recommended
Recommended Products Summary
Engineering reference data for TS942AIN — comparison, design guidance, and compliance information.
Selection Guide
Comparison with Alternatives
| Parameter | This Product | TS942A | TS942AI | TS942 | TS942AID |
|---|---|---|---|---|---|
| Brand | STMicroelectronics | STMicroelectronics | STMicroelectronics | STMicroelectronics | STMicroelectronics |
| Package | 8-DIP | 8-DIP | 8-DIP | 8-DIP | 8-DIP |
| Number of Amplifiers | 2 channels | 2 channels | 2 channels | 2 channels | 2 channels |
| Amplifier Type | General-purpose operational amplifier | General-purpose operational amplifier | General-purpose operational amplifier | General-purpose operational amplifier | General-purpose operational amplifier |
| Supply Voltage Range | 2.5 V to 10 V | 2.5 V to 10 V | 2.5 V to 10 V | 2.5 V to 10 V | 2.5 V to 10 V |
| Supply Current per Channel | 1.2 uA typical | 1.2 uA typical | 1.2 uA typical | 1.2 uA typical | 1.2 uA typical |
| Output Configuration | Rail-to-rail | Rail-to-rail | Rail-to-rail | Rail-to-rail | Rail-to-rail |
| Typical Output Current | 5 mA | 5 mA | 5 mA | 5 mA | 5 mA |
| Operating Temperature Range | -40 °C to +85 °C | -40 °C to +85 °C | -40 °C to +85 °C | -40 °C to +85 °C | -40 °C to +85 °C |
Key Differentiators
- Very low dual-channel supply current (vs LM324NSR)
- Low-voltage rail-to-rail output operation (vs TS942A)
- Compact eight-pin through-hole integration (vs TS942AI)
- Broad family temperature capability (vs TS942AID)
Design Notes
Place the TS942AIN close to the sensor or signal source to minimize capacitive loading and susceptibility to induced noise. Keep input and feedback traces short, avoid routing them parallel to switching-conductor paths, and provide a quiet ground return. Use a local bypass capacitor at the supply pins, with its ground connection routed directly to the device ground area. The manufacturer datasheet should be used to select the final capacitor value.
Design the supply around the confirmed 2.5 V to 10 V operating range and the approximately 1.2 uA per-channel supply current. Check startup behavior, output validity, and load current rather than assuming that low quiescent current guarantees low total system consumption. External pull-ups, bias networks, ADC inputs, and external loads can dominate the power budget and must be included in the complete current calculation.
Do not assume that a rail-to-rail output implies rail-to-rail input operation. Verify the input common-mode range, output swing, input bias current, offset voltage, noise, and stability with capacitive loading before finalizing the schematic. For high-impedance sources, account for bias-current-induced error and leakage from PCB contamination. A conventional dual amplifier such as LM324NSR may offer different accuracy or bandwidth characteristics.
For sensor signals with slow bandwidth but poor common-mode margin, evaluate offset and drift over the full -40 °C to +85 °C operating range. The TS942AIN is a general-purpose micropower amplifier, so its dynamic performance may not suit precision or high-bandwidth instrumentation. Confirm the unity-gain bandwidth, slew rate, noise density, and load stability before choosing it for a fast acquisition channel.
Compliance Information
RoHS compliance is identified in the manufacturer-family and distributor search information. No verified REACH, lead-free, halogen-free, conflict-minerals, or automotive-qualification statement was identified for this exact orderable device.