存储芯片价格每日波动——网站价格可能滞后于市场行情。请提交询价单以获取最新报价。
获取最新价格 →
Rockwell Automation

1756-L72 - 4 MB ControlLogix 5572 Processor | Allen-Bradley

料号: 1756-L72 ✓ 量产中
有现货 1-3 个工作日内发货
4 MB Memory
联系我们 询价
最小起订量: 1 |
价格更新于: 2026-10-20
批量定价
数量 单价 小计
1 $0 $0.00
10 $0 $0.00
100 $0 $0.00
500 $0 $0.00
1,000 $0 $0.00
ℹ️ 所有价格均以 USD 计价

1756-L72 概述

The Allen-Bradley 1756-L72 is a ControlLogix 5572 programmable automation controller with 4 MB of user memory, designed for modular industrial PLC systems. It installs in a compatible ControlLogix chassis and communicates through backplane-compatible modules. The verified product material identifies a USB 2.0 port, 0.98 MB of I/O memory, backplane power requirements of 800 mA at 5.1 VDC and 5 mA at 1.2 VDC, and a 0°C to 60°C operating range. Its primary role is executing control logic, coordinating I/O modules, and supporting factory automation, process-control, batch, and machine-control architectures.

A programmable logic controller is an industrial control device that executes user-defined logic according to a stored program. In the broader hierarchy, this product is a PLC processor within the ControlLogix platform, which sits inside modular programmable automation systems. Unlike a standalone embedded controller, the 1756-L72 is designed around a multi-module chassis, where processor, communication, and I/O modules share a common backplane. This architecture lets engineers expand or reconfigure a control system while retaining a common Rockwell Automation programming environment.

The 1756-L72’s 4 MB user-memory figure is its headline capacity specification, while 0.98 MB of I/O memory supports controller-side I/O data handling. The processor includes USB 2.0 connectivity according to the verified distributor listing, and firmware downloads listed on the Rockwell product page include versions for both 1756-L72 and 1756-L72EROM. The available documentation also references the ControlLogix 1756 User Manual and technical-data publications, which should be consulted for complete electrical, environmental, compatibility, and replacement requirements.

Because this is a modular PLC processor rather than an electronic semiconductor, its enclosure package does not use a small IC package designation. The supplied data confirms a ControlLogix rack/chassis module format, but dimensions, terminal details, front-panel pinout, and exact connector mapping were not provided. For system design, select a compatible ControlLogix chassis and communication modules based on the required network protocols and I/O capacity. Confirm firmware revision, replacement status, module revisions, and application compatibility before replacing an existing processor.

Typical applications include high-end machine control, packaging and assembly lines, process plants, batch control, and factory systems with moderate-to-high program complexity. The 4 MB user-memory capacity is useful when the application exceeds the memory available in smaller ControlLogix processors. Network connectivity is provided through compatible ControlLogix communication modules rather than by treating the processor as a standalone Ethernet device.

For a new design, verify chassis size, power-supply capacity, module compatibility, firmware requirements, and network architecture against the manufacturer’s current technical documentation. Existing installations should preserve controller configuration and program files, document communication settings, and follow Rockwell Automation’s replacement and migration guidance. This page synthesizes the verified product specifications, source documents, compatibility references, and engineering cautions not presented as a substitute for the manufacturer’s complete manuals.

直接替换替代料: 1756-L72 ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。

本系列中的变体

可与以下型号直接替换的同系列型号: 1756-L72 (相同外形与封装尺寸) ——差异在于 User Memory.

Rockwell Automation
User Memory: 32 MB
对比 1756-L72 →

快速对比工具——选择替代料号进行并排对比:

1756-L72EROM

✅ 直接替换
📦 ControlLogix chassis module
Exact controller-family alternative; the supplied data identifies firmware compatibility for 1756-L72 and 1756-L72EROM, but does not quantify all electrical or memory differences.

📋 参考替代料(不在目录中)

1756-L71

✅ 直接替换
📦 ControlLogix chassis module
Same ControlLogix processor family and chassis format, but the supplied comparison identifies 2 MB user memory versus 4 MB for the 1756-L72.

📋 参考替代料(不在目录中)

1756-L73

✅ 直接替换
📦 ControlLogix chassis module
Same ControlLogix controller family and module format; the supplied sources do not quantify the L73 memory or performance differences, so replacement suitability requires verification.

📋 参考替代料(不在目录中)

1756-L55

✅ 直接替换
📦 ControlLogix chassis module
ControlLogix processor alternative discussed in the supplied upgrade search, but the verified data does not establish identical memory, firmware, or electrical ratings.

📋 参考替代料(不在目录中)

1756-L71EROM

✅ 直接替换
📦 ControlLogix chassis module
ControlLogix family processor variant; the supplied data does not provide enough verified specifications to quantify compatibility with the 1756-L72.

📋 参考替代料(不在目录中)

1756-L72 最大额定值与电气特性

Product Type ControlLogix 5572 processor module
User Memory 4 MB
I/O Memory 0.98 MB
Communication Port USB 2.0
Backplane Power at 5.1 VDC 800 mA
Backplane Power at 1.2 VDC 5 mA
工作温度范围 0°C to 60°C
Controller Platform ControlLogix
Processor Family Logix 5572
System Architecture Modular chassis-based programmable controller
Communication Support Compatible ControlLogix communication interface modules
Firmware Support Firmware versions listed for 1756-L72 and 1756-L72EROM
Data Retention and Programming Resources 1784-SD1 Secure Digital card referenced in supplied ControlLogix documentation

1756-L72 standard 引脚配置指南

1756-L72(standard 封装)的引脚配置。 该数字 IC 包含 GPIO、通信接口(UART、SPI、I2C)和电源引脚。请参阅制造商数据手册以了解复用引脚功能和配置选项。对嵌入式系统设计和 PCB 布局至关重要。

1756-L72 的 standard 封装引脚图

暂无详细引脚数据: 1756-L72.

请参阅 数据手册 以查看完整引脚配置。

典型应用

1756-L72 适用于 6 应用s: Packaging and Assembly Machine Control, Process-Control and Batch Automation, Conveyor and Material-Handling Systems, Factory Cell Network Integration, OEM Machine Builder Platforms, Control-System Retrofit and Replacement.

🏭

Packaging and Assembly Machine Control

The Allen-Bradley 1756-L72 fits packaging and assembly systems that need a ControlLogix processor with 4 MB of user memory. Its modular architecture allows machine designers to combine the processor with local I/O and communication modules for conveyors, sensors, actuators, safety interlocks, and station sequencing. The verified 4 MB memory figure provides more capacity than the 2 MB 1756-L71 comparison result, making the L72 more appropriate when the application includes extensive state logic, diagnostics, recipes, or multiple machine sections. Confirm chassis power, module revisions, network topology, and firmware before commissioning. The processor should be installed according to Rockwell installation instructions, with system grounding, cooling, and service access planned into the control cabinet.

⚡

Process-Control and Batch Automation

The 1756-L72 can serve as the central programmable controller for process and batch equipment when the control architecture is already based on ControlLogix. Its 4 MB user memory is relevant for recipe data, alarm handling, sequencing, and equipment logic, while the supplied 0.98 MB I/O-memory figure supports controller-side I/O data handling. A process system can add compatible communication modules for distributed networks and use the ControlLogix platform for coordinated control of valves, pumps, heaters, and interlocks. The verified data does not provide a complete analog-module recommendation or environmental certification, so the engineer must verify process ratings, module accuracy, hazardous-area requirements, and controller temperature limits separately. Firmware and program backups should be controlled before any replacement.

🔧

Conveyor and Material-Handling Systems

The Allen-Bradley 1756-L72 is appropriate for conveyor and material-handling control when the system requires distributed I/O and structured machine logic. A ControlLogix chassis can host digital input and output modules for photoeyes, encoders, zone sensors, drives, and solenoid outputs, while communication interface modules connect the controller to higher-level equipment. The 4 MB user-memory capacity gives the project room for tracking logic, alarms, counters, diagnostic data, and operating modes. The supplied specification identifies 0.98 MB of I/O memory and a 0°C to 60°C operating range, but the complete system rating depends on the selected modules and enclosure. During design, calculate backplane power, maintain service clearances, and use the manufacturer’s installation instructions for grounding and wiring.

🌐

Factory Cell Network Integration

The 1756-L72 can anchor a factory cell when the controls engineer wants a ControlLogix platform rather than a standalone PLC. Its modular backplane supports communication modules and distributed I/O, allowing the same controller platform to coordinate local machine functions with supervisory networks. The supplied documentation specifically states that appropriate communication interface modules provide controller communication, so the processor should not be treated as a standalone network device. Verify the required EtherNet/IP, ControlNet, or DeviceNet architecture, node limits, bandwidth, and firmware compatibility. Because the provided web data does not include full environmental or lifecycle details for every option, confirm current Rockwell product documentation before ordering. Back up the control program and verify module revisions during replacement or migration.

🏗️

OEM Machine Builder Platforms

The Allen-Bradley 1756-L72 is useful as the programmable controller in an OEM machine platform that standardizes on ControlLogix. The 4 MB user-memory capacity supports more complex control logic than the supplied 2 MB 1756-L71 comparison, which can help when the machine includes recipes, diagnostics, remote commands, and multiple operating modes. The processor is installed in a compatible chassis and populated with application-specific I/O modules, so the final bill of material must include network interfaces, power supplies, termination, and field wiring. Use the 800 mA at 5.1 VDC and 5 mA at 1.2 VDC values as part of the system power calculation, not as the total cabinet demand. Rockwell documentation should govern mechanical installation, firmware, program download, and service procedures.

♻️

Control-System Retrofit and Replacement

The 1756-L72 can be evaluated for a ControlLogix retrofit or processor replacement when the existing machine already uses the 1756 platform and the application needs more memory than the 1756-L71. The verified 4 MB user-memory specification is the principal sizing distinction identified in the supplied comparison material. However, a replacement should not be treated as automatically interchangeable: verify chassis compatibility, power-supply capacity, communication modules, I/O revision, firmware, program dependencies, and any safety or availability requirements. Preserve the existing project files and controller configuration before removal. Rockwell compatibility tools and the 1756 replacement guidance should be consulted for the exact machine revision. If a cross-manufacturer PLC is considered, engineering redesign and software migration are usually required.

推荐产品汇总

1756-EN3TR EtherNet/IP communication module for the ControlLogix chassis 用于: Packaging and Assembly Machine Control, Process-Control and Batch Automation, Conveyor and Material-Handling Systems, Factory Cell Network Integration, OEM Machine Builder Platforms, Control-System Retrofit and Replacement 1756-IB16 ControlLogix digital input module for machine sensors 用于: Packaging and Assembly Machine Control, Conveyor and Material-Handling Systems, OEM Machine Builder Platforms, Control-System Retrofit and Replacement 1756-OB16 ControlLogix digital output module for actuators 用于: Packaging and Assembly Machine Control, Conveyor and Material-Handling Systems, OEM Machine Builder Platforms, Control-System Retrofit and Replacement 1756-IF4 Analog input module for process measurements 用于: Process-Control and Batch Automation 1756-OF4 Rockwell Automation 用于: Process-Control and Batch Automation 1756-CN2 ControlNet communication module 用于: Factory Cell Network Integration 1756-CNETR ControlNet adapter for compatible architectures 用于: Factory Cell Network Integration
What is the Allen-Bradley 1756-L72 used for?
The Allen-Bradley 1756-L72 is a ControlLogix 5572 processor module used to execute PLC logic in modular industrial automation systems. The verified Rockwell Automation product page identifies it as a ControlLogix 4 MB Controller, while the supplied distributor listing identifies 4 MB of user memory and 0.98 MB of I/O memory. It is intended for machine control, process automation, and factory systems that use compatible ControlLogix chassis, I/O modules, and communication interface modules.
How much memory does the 1756-L72 have?
The 1756-L72 has 4 MB of user memory and 0.98 MB of I/O memory. The 4 MB capacity is stated in the supplied Rockwell Automation product result and the 0.98 MB I/O-memory value appears in the verified distributor listing. Memory suitability should be checked against the application’s program size, data requirements, task structure, and the current ControlLogix technical documentation before installation.
Where can I download the 1756-L72 datasheet?
The 1756-L72 technical documentation is available through Rockwell Automation’s supplied ControlLogix technical-data PDF and product page. The verified sources include the ControlLogix Controllers Specifications Technical Data document and the official 1756-L72 product page. The document set also references the 1756 User Manual, publication 1756-UM001. Download the current document from Rockwell Automation and verify its publication revision before using it for design or maintenance.
What is the operating temperature of the 1756-L72?
The supplied distributor specification lists an operating temperature of 0°C to 60°C for the 1756-L72. The ControlLogix technical-data result also explains that system temperature can be derated when the processor, modules, and chassis have different temperature limits. Use the lowest applicable enclosure, chassis, or module rating rather than relying only on the processor specification.
Does the 1756-L72 have USB 2.0?
Yes. The verified distributor listing identifies a USB 2.0 port on the Allen-Bradley 1756-L72. This port is part of the controller’s service and programming connectivity, but the supplied data does not define the complete cable, operating-system, or security-support list. Confirm current compatibility and recommended procedures in Rockwell Automation documentation before using the port for programming or maintenance.
Is the 1756-L72 a drop-in replacement for another processor?
The supplied web data does not verify five or more pin-compatible drop-in replacements for the 1756-L72. Rockwell compatibility results mention 1756-L72 in product-comparison contexts, but they do not establish a universal drop-in replacement. A replacement must match the chassis, power budget, communication modules, I/O configuration, program environment, firmware, and application requirements. Do not treat a functionally similar PLC as a drop-in replacement without Rockwell compatibility confirmation.
What is the difference between 1756-L72 and 1756-L71?
The supplied comparison result describes the 1756-L71 as a Logix 5571 controller with 2 MB of user memory, while the 1756-L72 is identified as a 4 MB ControlLogix controller. That makes the L72 the higher-memory option for applications needing additional program or data capacity. Scan rate, communication options, motion capability, and exact compatibility must still be checked in the current ControlLogix comparison and technical data before migration.
Can the 1756-L72 replace a 1756-L55?
The supplied search results include a discussion about upgrading from a 1756-L55 to a 1756-L72, but they do not provide manufacturer confirmation of a direct drop-in replacement. The 1756-L72 is identified as a 4 MB ControlLogix processor, while the compatibility page lists 1756-L55 as another module in a replacement context. Verify catalog revisions, firmware, program size, network modules, I/O, and migration requirements before replacing the 1756-L55.
How much backplane power does the 1756-L72 require?
The verified distributor specification lists 800 mA at 5.1 VDC and 5 mA at 1.2 VDC for the 1756-L72 backplane power requirements. These values must be included in the chassis power-supply budget together with all installed I/O and communication modules. The system designer should also account for startup demand, module tolerance, and the complete ControlLogix technical-data requirements rather than sizing the supply from the processor value alone.
Where can I buy the 1756-L72 online?
The 1756-L72 is listed for purchase or quotation through industrial automation distributors and integrators, including the supplied Octopart, DO Supply, and Radwell sources. Price and availability are not provided as fixed values in the verified data, so the tiers on this page should not be interpreted as a quotation. When requesting a quote, provide the required quantity, firmware revision, warranty terms, delivery date, and certification or provenance requirements.
What is the price of the 1756-L72?
A verified numeric unit price for the Allen-Bradley 1756-L72 was not included in the supplied data. The verified Octopart result identifies a price-comparison page, while the distributor listings state that quotation or ordering is available. Obtain a current quote from an authorized distributor and confirm whether the price includes firmware, warranty, taxes, freight, and required ControlLogix accessories. The zero values in the price tiers indicate that price data was not provided.
What is the lead time for the 1756-L72?
The supplied verified data does not state a reliable manufacturer or distributor lead time for the 1756-L72. The DO Supply result says the product is available and invites a fast quote, but that is not a guaranteed lead-time commitment. Ask the supplier for a date tied to the exact catalog number, firmware revision, quantity, and delivery location. For a running machine, obtain a spare or replacement processor before the existing unit reaches its planned replacement point.
Is the 1756-L72 in stock?
The supplied distributor results indicate that the 1756-L72 may be available, including an Octopart availability-comparison page and distributor listings describing availability or in-stock status. However, no current stock quantity or timestamped distributor inventory was supplied. Treat availability as changeable and request confirmation before purchasing. A listing that says in stock does not guarantee same-day shipment, exact firmware, or allocation for your order.
What communications options are available for the 1756-L72?
The 1756-L72 supports communication through compatible ControlLogix communication interface modules. The supplied documentation states that appropriate communication modules should be installed in the chassis to provide controller communication. The processor itself is not a complete network interface specification, so EtherNet/IP, ControlNet, DeviceNet, or other network requirements depend on the selected modules. Select modules and verify node, bandwidth, and firmware compatibility.
What is the best use case for the 1756-L72?
The 1756-L72 is best suited to modular factory automation applications that need a ControlLogix processor with 4 MB of user memory. It can support machine-control, packaging, assembly, process-control, and batch-control logic when the system uses compatible chassis, I/O, and communication modules. Choose it when its memory and ControlLogix capabilities match the application and when the plant can support Rockwell’s programming, firmware, and maintenance ecosystem.
Can a 1756-L72 replace a ControlLogix processor from another manufacturer?
The supplied evidence does not establish a cross-manufacturer drop-in replacement for the 1756-L72. Cross-brand alternatives were not verified with a matching package, pin compatibility, electrical ratings, programming environment, and chassis architecture. A competing PLC may provide functional equivalence but would generally require different hardware, software, wiring, and integration work. Use Rockwell Automation compatibility documentation or a qualified controls integrator before approving any substitution.

工程参考数据: 1756-L72 ——对比、设计指导和合规信息。

选型指南

Choose the Allen-Bradley 1756-L72 when an existing or new system uses ControlLogix and needs a processor with 4 MB of user memory. It is a strong fit for complex machine logic, factory cells, packaging systems, process-control sequences, and applications with substantial diagnostics or configuration data. The 1756-L71 may be sufficient when 2 MB is adequate, but it provides less verified user memory. The 1756-L55 appears in the supplied upgrade discussion, but compatibility must be confirmed rather than assumed. Treat all listed same-brand alternatives as candidate ControlLogix modules only until Rockwell documentation verifies memory, firmware, power, network, and I/O compatibility. Do not select a competing manufacturer’s PLC when the existing cabinet, programming environment, wiring, and safety architecture require ControlLogix.

与替代料对比

参数 本产品 1756-L72EROM 1756-L71 1756-L73 1756-L55
Product Type ControlLogix 5572 processor module ControlLogix processor variant Logix 5571 processor ControlLogix controller variant ControlLogix processor discussed in upgrade results
Package ControlLogix chassis module ControlLogix chassis module ControlLogix chassis module ControlLogix chassis module ControlLogix chassis module
Brand Rockwell Automation Rockwell Automation Rockwell Automation Rockwell Automation Rockwell Automation

关键差异点

  • Higher verified user-memory capacity than the 1756-L71 comparison (对比 1756-L71)
  • ControlLogix 5572 processor positioning (对比 1756-L72EROM)
  • Established ControlLogix module ecosystem (对比 1756-L73)

设计说明

Include the processor in the complete ControlLogix chassis power calculation. The verified listing specifies 800 mA at 5.1 VDC and 5 mA at 1.2 VDC for the 1756-L72. Add the current draw of every installed I/O and communication module, then size the power supply and protection for worst-case operating conditions. Do not treat the processor’s backplane figures as the total system demand, and verify the current ratings against the manufacturer’s technical data.

Do not assume that a ControlLogix processor is a universal drop-in replacement. Confirm the chassis, power supply, I/O modules, communication modules, firmware revision, program dependencies, and required controller features. The supplied results discuss 1756-L71 and 1756-L55 comparisons, but they do not prove universal compatibility. Back up the project and controller configuration before removal, and follow Rockwell Automation replacement guidance for the specific machine.

Plan the chassis layout for service access, signal separation, grounding, and thermal performance. Keep high-current field wiring away from sensitive communication and signal wiring where practical, and follow the installation instructions for terminal wiring and cabinet clearances. The verified 0°C to 60°C processor rating does not establish the complete system rating; enclosure temperature, adjacent modules, and chassis configuration must also meet their respective limits.

Use the lowest applicable temperature limit in the installed system rather than the 0°C to 60°C processor specification alone. Control cabinets, chassis, and neighboring modules can reduce the allowable system temperature. The supplied Rockwell technical-data result explicitly describes derating when module and chassis temperature limits differ. Validate thermal conditions during commissioning and maintain airflow and cabinet temperature monitoring for process or continuous-duty installations.

合规信息

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
无铅
Unknown
无卤
Unknown
冲突矿物
Unknown

The supplied product and distributor results do not provide verified RoHS, REACH, lead-free, halogen-free, conflict-minerals, or automotive qualification statements. AEC-Q100 is not applicable to this industrial PLC processor based on the supplied data.

相关搜索

1756-L72 Allen-Bradley 1756-L72 datasheet 1756-L72 ControlLogix 5572 1756-L72 4 MB controller 1756-L72 replacement 1756-L72 vs 1756-L71 1756-L72 buy online 1756-L72 price 1756-L72 lead time ControlLogix 1756-L72 module 1756-L72 industrial PLC processor 1756-L72 pinout ControlLogix processor upgrade from 1756-L55 1756-L72 factory automation controller best replacement for Allen-Bradley 1756-L72

相关元器件 & 术语

Allen-Bradley Rockwell Automation 1756-L72 1756-L72EROM 1756-L71 1756-L73 1756-L55 ControlLogix Logix 5572 Logix 5571 programmable logic controller PLC processor modular programmable automation system 4 MB user memory 0.98 MB I/O memory USB 2.0 ControlLogix chassis ControlLogix communication interface module backplane power factory automation machine control process control batch control EtherNet/IP ControlNet DeviceNet
快速报价
填写完整信息——我们的销售团队将在 24 小时内回复
料号 制造商 封装 QTY 目标价 小计
合计: $0.00 USD
✓
报价已提交!

我们将在 24 小时内回复您的邮件

1
询价已提交
2
已收到报价
3
已下单
4
支付
5
已发货
6
已送达
查看询价详情