MAX232AEUE+T 5V RS-232 Transceiver | Analog Devices
N.º de pieza: MAX232AEUE+T ✓ ActivoMAX232AEUE+T Descripción general
An RS-232 transceiver is an interface IC that bridges digital logic and a serial communications port. The transmitter converts TTL/CMOS signals into RS-232 levels, while the receiver converts RS-232 inputs into logic-compatible signals. In the broader device hierarchy, the MAX232AEUE+T belongs to the line-driver/receiver class, interface IC family, and semiconductor category used to connect a UART or other digital controller to an RS-232 port.
The MAX232AEUE+T is identified as a 2/2 full-RS-232 transceiver, meaning that it contains two driver outputs and two receiver inputs. Its +5 V supply operation allows implementation around conventional 5 V digital systems. The MAX232A family is listed in production, and the 16-pin TSSOP package is approximately 4.40 mm wide. Its dual-channel arrangement is useful where two serial ports must share a compact board footprint.
The manufacturer describes the MAX220 through MAX249 family as supporting EIA/TIA-232E and V.28/V.24 interfaces, especially where positive and negative 12 V rails are not available. The MAX232A therefore concentrates the RS-232 electrical layer beneath an existing UART or microprocessor serial interface. Exact slew rate, propagation delay, receiver thresholds, and charge-pump capacitor requirements should be confirmed in the MAX232A data sheet before a new circuit is released.
Typical uses include industrial serial adapters, laboratory instrument interfaces, configuration ports, embedded equipment links, and legacy computer peripherals. The two transmitters and two receivers permit full-duplex communication on each RS-232 channel. Board-level design must preserve the required charge-pump capacitors, logic-side supply decoupling, and clearances between logic and high-voltage RS-232 nets.
Keep input and output transceivers close to their associated connector or signal source, and route differential RS-232 traces away from sensitive clocks and analog signals. Confirm the package pin numbering against the MAX232A data sheet before assigning PCB nets. The narrow TSSOP body also requires careful assembly planning because its lead pitch and body width leave limited routing space.
This page organizes the verified MAX232A family information, exact MAX232AEUE+T package identification, sourcing details, interface standards, and replacement considerations into an engineering-focused reference. It also distinguishes the directly documented device from related family members whose package, channel count, or electrical details differ.
Alternativas directas para MAX232AEUE+T — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.
Variantes de esta serie
Modelos de la misma serie compatibles directamente con MAX232AEUE+T (mismo factor de forma y huella) — difiere en Interface Standard, Number of Receivers.
MAX232AEUP+T
✅ Sustitución directa ⚠️ Especificaciones sin verificar📋 Alternativa de referencia (no en el catálogo)
MAX232AEUA+T
✅ Sustitución directa ⚠️ Especificaciones sin verificar📋 Alternativa de referencia (no en el catálogo)
MAX232AEUE+T Especificaciones
| Product Type | RS-232 dual transmitter/receiver interface IC |
| Tensión de alimentación | +5 V |
| Number of Transmitters | 2 channels |
| Number of Receivers | 2 channels |
| Interface Standard | EIA/TIA-232E, V.28, and V.24 |
| Encapsulado | 16-pin TSSOP |
| Package Width | 4.40 mm |
| Package Width (Imperial) | 0.173 inch |
| Tipo de montaje | Surface mount |
| Production Status | Production |
| Driver Output Type | Full RS-232 |
Guía de configuración de pines de MAX232AEUE+T 0.173 inch
Configuración de pines para MAX232AEUE+T (encapsulado 0.173 inch). La numeración de pines, las funciones y los diagramas de conexión se definen en la hoja de datos del fabricante. Consúltela para conocer el footprint exacto y las directrices de soldadura.
No hay datos detallados de patillaje disponibles para MAX232AEUE+T.
Consulte la hoja de datos para ver la configuración completa de patillas.
Aplicaciones típicas
MAX232AEUE+T es adecuado para 6 aplicacións: Industrial Serial Adapter, Laboratory Instrument Control Port, Embedded Configuration Interface, Legacy Computer Peripheral, Point-to-Point Communication Link, Data Acquisition Equipment.
Industrial Serial Adapter
The MAX232AEUE+T is suitable for an industrial serial adapter that converts a 5 V controller UART into an EIA/TIA-232E-compatible port. Its two transmitters and two receivers allow two bidirectional RS-232 channels to share one compact 16-pin TSSOP. The device eliminates the need for positive and negative 12 V interface rails, although the charge-pump capacitors and bypass capacitor still require correct placement. For an enclosure-mounted adapter, keep the RS-232 traces away from switching supplies and route the driver outputs toward the connector with minimal loop area. The dual-channel arrangement is especially useful when equipment must expose both a primary control port and a secondary service or diagnostic port.
Recomendado
Laboratory Instrument Control Port
The MAX232AEUE+T can provide the physical RS-232 layer for a laboratory instrument controlled by a 5 V embedded controller. Two transmitters and two receivers support separate command and response channels or two instrument buses, while the single +5 V supply simplifies integration with digital logic. Maintain a clean separation between logic-side traces and the bipolar RS-232 side, and verify the data sheet's charge-pump capacitor values and receiver thresholds during schematic review. This arrangement reduces the number of external level-shifting rails compared with a discrete ±12 V driver implementation.
Recomendado
Embedded Configuration Interface
The MAX232AEUE+T fits an embedded configuration port where a service technician connects a computer or terminal to equipment that otherwise operates from +5 V. Its two full-duplex channels can carry a primary configuration link and an auxiliary diagnostic link, and the 16-pin TSSOP preserves board area in compact control systems. The UART or processor must be configured for the interface's electrical conventions, and the board should include the manufacturer-required charge-pump capacitors close to the device. Use a protected connector or enclosure arrangement when the port will be accessible in uncontrolled environments.
Recomendado
Legacy Computer Peripheral
The MAX232AEUE+T is appropriate for a legacy computer peripheral that exposes an RS-232 port from a +5 V controller. Because the MAX232A family supports EIA/TIA-232E, V.28, and V.24 communications interfaces, it can bridge a modern digital controller to established RS-232 equipment without separate positive and negative 12 V rails. The 2/2 channel count can serve two peripheral connections if the wiring plan allows it. Confirm connector pin assignment, ground continuity, and software flow control because the transceiver solves voltage translation, not protocol or cable-direction issues.
Recomendado
Point-to-Point Communication Link
The MAX232AEUE+T can establish two point-to-point RS-232 links between two +5 V systems. Each transmitter drives one receiver, creating full-duplex communication when the transmit and receive conductors are paired correctly. This is useful in equipment racks, test fixtures, and short industrial links where a multi-drop RS-485 bus would be inappropriate. The driver and receiver stages perform only the electrical interface, so cable length, ground reference, and protocol timing remain separate design constraints. Confirm the MAX232A electrical limits and connector protection requirements before deploying long or noisy interconnects.
Recomendado
Data Acquisition Equipment
The MAX232AEUE+T can serve as the RS-232 interface for data-acquisition equipment that uses a 5 V control plane while connecting to a host computer or service terminal. The two receiver channels can accept status or command information, and the two transmitter channels can carry responses or sampled data. Its narrow 16-pin TSSOP package is useful where connector placement and routing space are constrained. Place the interface away from high-current analog sections, observe the manufacturer's charge-pump capacitor layout, and use controlled grounding to prevent ground currents from coupling into measurement circuitry.
Recomendado
Resumen de productos recomendados
Datos de referencia de ingeniería para MAX232AEUE+T — comparación, orientación de diseño e información de cumplimiento.
Guía de selección
Comparación con alternativas
| Parámetro | Este producto | MAX232AEUP+T | MAX232AEUA+T |
|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Package | 16-pin TSSOP | 16-pin TSSOP | 16-pin TSSOP |
| Transmitter Count | 2 channels | 2 channels | 2 channels |
| Receiver Count | 2 channels | 2 channels | 2 channels |
| Supply Voltage | +5 V | +5 V | +5 V |
| Supported Interface Standards | EIA/TIA-232E, V.28, and V.24 | EIA/TIA-232E, V.28, and V.24 | EIA/TIA-232E, V.28, and V.24 |
| Driver Type | Full RS-232 | Full RS-232 | Full RS-232 |
| Package Width | 4.40 mm (0.173 inch) | 4.40 mm (0.173 inch) | 4.40 mm (0.173 inch) |
Diferenciadores clave
- Combines two transmit and two receive channels in one interface device (frente a MAX232AEUP+T)
- Uses a single +5 V supply architecture (frente a MAX232AEUA+T)
- Targets established point-to-point RS-232 standards (frente a MAX232AEUP+T)
Notas de diseño
Place the charge-pump capacitors directly beside their designated MAX232AEUE+T pins and keep their return paths short, as specified in the manufacturer application circuit. Place the logic-side bypass capacitor close to the +5 V supply pin. Keep the footprint orientation consistent with the package drawing, because the 16-pin TSSOP body is narrow and incorrect pad placement can create assembly or soldering problems.
Separate logic-side nets from RS-232 driver outputs on the PCB. Route driver outputs toward the connector with a short path and avoid routing them beneath sensitive analog sections. Connect the logic and interface grounds using the topology shown in the manufacturer reference circuit, and verify connector shield and chassis-ground treatment separately from the circuit ground.
Do not treat the MAX232AEUE+T as an RS-485 transceiver or as a replacement for a transceiver with a different channel arrangement. Confirm the complete 16-pin mapping, required capacitor values, receiver enable states, and supported temperature range against the manufacturer data sheet. Also distinguish MAX232AEUE+T from packaging-only ordering forms before releasing the BOM or placing a footprint.
Información de cumplimiento
The verified product information identifies MAX232A as a production RS-232 interface family but does not provide specific RoHS, REACH, lead-free, halogen-free, or conflict-minerals declarations for MAX232AEUE+T.